Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.1 LAccepted-AOC WARD NO 02 LAKHUWALI PO THE PILIBANGAN DISTT HANUMANGARH RAJASTHAN 335803 | HANUMANGARH | RAJASTHAN | 335803 | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹15.8 L+₹3.9 L (33.1%)Rejected-Finance RZ H 5 NANDA BLOCK MAHAVIR ENCLAVE PART 1 PAL AM SOUTH WEST DELHI DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹20.7 L+₹8.9 L (74.8%)Rejected-Finance BHAGAT SINGH CHOWK SURATGARH 335804 DISTT SRIGANGANAGAR RAJ | GANGANAGAR | RAJASTHAN | 335804 | L3 | Rejected-Finance Other than lowest bidder |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
12 Nov 2020, 6:00 pmClosed
GE (N) Bikaner
GE (N) Bikaner Mil Stn Bikaner
REPAIRS TO EXTERAL WATER SUPPLY PIPE LINE AND CONNECTED ITEMS OF VARIOUS LOCATIONS AT MFFR UNDER GE (N) BIKANER
2020_MES_385242_1
GE (N) BKN-Token/44/2020-21
Open Tender
Civil Works
Item Rate
330 days
GE (N) Bikaner
Class E Category a (ii)
8 documents required · 8 mandatory
₹500
GE (N) BIkaner
₹40,000
Yes
20 Apr 2021
10 Oct 2020
14 Nov 2020
10 Oct 2020
12 Nov 2020
28 Oct 2020
Amount
Excavation in trenches in soft/loose soil not exc 1.5mtr wide and not exc 1.5mtr in depth for taking out old pipe and laying new pipe line etc. not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out complete all as specified and as directed.
Returning and filling including spreading, levelling, watering and well ramming in layers not exc 25 cm thick in any type of soil complete all as specified and as directed.
Removing surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 meter above the starting point complete all as specified and as directed.
Supplying, laying, jointing and testing ductile iron pipe spigot & socketed size 150mm dia, class K-9 suitable for rubber tyton joints duly ISI marked complete all as specified and directed by Engr-in-Charge. Note:- Excavation and earth work and joints shall be measured and paid separately.
M&L for rubber tyton push on gasket joints in spigot and socketed DI pipes and fittings of 150 mm dia bore complete all as specified and directed.
Supply and fixing in replacement of existing pipe any type and size in any condition at various location including GI pipe medium grade 150 mm bore (ISI marked) laid in trenches/ road crossings/along walls/ path /drain/floors with and including clamps, nuts, bolts, washers,sockets,elbow etc and all necessary arrangement to connect existing branch pipe of any type and size including all necessary fittings required at site and testing complete all as specified and as directed by the Engineer-in-Charge. (Note:- Earth work shall be measured and paid for separately.)
All as per item No 6 above but size 100 mm dia.
All as per item No 6 above but size 80 mm dia.
All as per item No 6 above but size 50 mm dia.
All as per item No 6 above but size 20 mm dia.
M & L Taking up or down the existing rusted/damage GI pipe of 150/160 mm dia including all fittings and removing from site complete all as specified and directed by Engineer-in-Charge.
M & L Taking out u/s rusted corroded GI / PVC pipe of size 100/ mm dia after cutting/unscrewing including all fittings from trenches /along walls/under road etc complete all as specified and directed.
M & L Taking up or down the existing rusted/damage GI/PVC pipe of 75/80 /90 MMmm dia including all fittings and removing from site complete all as specified and directed by Engineer-in-Charge.
M & L Taking out u/s rusted corroded GI/ PVC pipe of size 50 mm dia after cutting/unscrewing including all fittings from trenches /along walls/under roar etc complete all as specified and directed.
Laying only, jointing and testing old serviceable GI Medium grade of 100/80 mm bore obtained serviceable vide serial item No. 13.00 here-in-before including cleaning the pipe from inside & outside properly including rust & mud removal, with & including new fittings laid in trenchs in new or old position complete all as specified and as directed. Note : The quoted rate shall deemed to include new GI fittings (ISI marked). Old fittings shall not be used.
Ditto all as per serial item No. 15 here in before but retrived from Sl item No.14.00 and suitable for 50 mm bore.
Supply and fixing in replacement of cast iron sluice valve 80 mm, heavy duty class PN 1:6 ISI marked (IS-14846-2000), long body, both ends flanged, complete with high tensile stainless steel spindle, cast iron hand operated wheel and cap top, nuts, bolts, washers including 3mm thick rubber gasket joints, suitable for 80 mm bore GI/PVC pipe any type any size and also including testing and commissioning complete all as specified and as directed. Make - Leader/Sant/Kirlosker
Ditto all as per serial item No. 17 here in before but suitable for 100mm bore.Make - Leader/Sant/Kirlosker
Ditto all as per serial item No. 17 here in before but suitable for 150mm bore.Make - Leader/Sant/Kirlosker
Supply and Fixing in replacement of Reflex Valve/NRV/Dual plate check valve, PN 1.6 rating of size 100 mm dia with all necessary accessories and testing complete all as specified & directed. Make - Leader/Sant/Kirlosker
Supply and Fixing in repair foot valve of any type & in any condition CI Foot Valve size 80 mm dia conforming to IS suitable for 80mm bore pipe any type i.e thread/flanged type complete all as required at site. Make - Leader/Sant/Kirlosker
S&F in replacement of cast iron ditechable joints suitable for 200mm dia DI/GI pipe line including clamps, nuts, bolts, washers,sockets,elbow etc and all necessary arrangement and testing complete all as required at site and as directed.(Note:- Excavation shall be measured and paid for separately)
All as per item No22 above but size 150mm suitable for 150mm dia GI/DI pipe line
All as per item No 22 above but size 100mm suitable for 100mm dia GI/DI pipe line
S&F in replacement of PVC ditechable joints suitable for 200mm dia HDPE/PVC pipe line including clamps, nuts, bolts, washers,sockets,elbow etc and all necessary arrangement and testing complete all as required at site and as directed.(Note:- Excavation shall be measured and paid for separately)
All as per item No 25above but size 150/160mm suitable for 160/150mm dia HDPE/PVC pipe line
All as per item No 25 above but size 100mm suitable for 100mm dia HDPE/PVC pipe line
Rotational moulded polyethylene water storage tanks of capacity 10000 litres, (cylindrical vertical tanks with closed top) hoisted and fixed in position including making necessary arrangements for fixing inlet, outlet and over flow pipe and provision of wash out pipe etc complete all as specified and as directed by Engineer-in-Charge. (Notes : (i) The water storage tanks shall be 3 layers, HDPE tanks moulded to seem-less perfection of rotational moulding process. The tanks shall be manufactured only from FDA approved special grade of polyethylene and shall be certified fit for potable water. (ii) The tanks shall be white coloured with three layered wall and shall be ISI marked. Also refer paras 18.60 and 18.60 A of MES Schedule Part-I. (iii) Payment for inlet, outlet and over flow pipes and ball valve shall be made separately. However cost of providing necessary GI fittings such as nipples with check nuts for inlet and outlet pipes, GI plug with check nut for over flow pipe and 30 cm long wash out pipe, GI 20mm nominal bore, medium grade and check nut for wash out pipes of size as per actual requirements and as directed by the Engineer-in-Charge shall be deemed to be included in the unit rate of this item.(iv) HDPE storage tanks shall be procured from the manufacturers as per Appendix “D”.)
Ditto all as per serial item No. 28 here in before but suitable for 5000 ltr capacity PVC tank.
S&F 50mm bore Gun metal gate valve (ISI marked) with iron wheel head, screwed both ends for iron pipe, including dismantling & taking out old unserviceable gate valve of 50 mm bore, complete, all as specified & directed.
Ditto all as per serial item No. 30here in before but suitable for 20mm bore.
Repairing the leakage of DI/ GI pipe line 150 mm dia incl necessary excavationand bailing out of stagnent water and removing wild bushes/grass 3 mtr away from both sides of pipe line and removing u/s lead from the joint by burning and making new run lead joint all as directed by Eng-in-Charge.
Repairing the leakage of GI/ pvc pipe line 80 mm dia incl necessary excavationand bailing out of stagnent water and removing wild bushes/grass 3 mtr away from both sides of pipe line and removing u/s fittings from the joint/ leakage point and making new joint/repair with neccessary GI/PVC fiitins and testing or all as directed by Eng-in-Charge. Note : The quoted rate shall deemed to include new GI fittings (ISI marked). Old fittings shall not be used.
Ditto all as per serial item No. 33here in before but suitable for 50mm bore.
Ditto all as per serial item No. 33 here in before but suitable for 25mm bore.
Ditto all as per serial item No. 33 here in before but suitable for 20mm bore.
Supply and fixing in replacement of motor/pump protection relay model SPGD2 for phase failure,phase sequence,overloading etc, 380 to 440VAC complete with internal wiring connection in panel including all necessory arrangement and testing Make - Minilec/L&T/Siemens
Supply and fixing MCCB 4 pole 415 volt cap 200 Amp with rupturing capacity 35 KA Cat conf to IS 13947 Part-II Make L&T/LEGRAND/BCH -
Supply and fixing MCCB 4 pole 415 volt cap 100 Amp with rupturing capacity 35 KA Cat conf to IS 13947 Part-II Make L&T/LEGRAND/BCH -
Supply and fixing MCCB 4 pole 415 volt cap 63 Amp with rupturing capacity 35 KA Cat conf to IS 13947 Part-II Make L&T/LEGRAND/BCH -
Supplied and fixed in replacement of three phase terminal box suitable for three phase motor as per sample, any type any size with all necessary arrangement (i.e. cable lugs, nut bolts etc) complete all as required at site.
Supply and Fixing in replacement of Electronic contactor Mnx-18 or equilant suitable for 5 to 10 HP Pump set starter, 415 volt, 50 Hz, 3 phase, Make-L&T/Scneider/siemens
Supply and Fixing in replacement of Electronic relay suitable for 5 to 10HP Pump set starter, 415 volt, 50 Hz, 3 phase, Make-L&T/Scneider/siemens
Supply and Fixing in replacement of Electronic contactor Mnx-22 or equilant suitable suitable for 15HP Pump set starter, 415 volt, 50 Hz, 3 phase, Make-L&T/Scneider/siemens
Supply and Fixing in replacement of Electronic relay suitable for 20HP Pump set starter, 415 volt, 50 Hz, 3 phase, Make-L&T/Scneider/siemens
Supply and Fixing in replacement of Electronic contactor Mnx-25 or equilant suitable suitable for 20 HP Pump set starter, 415 volt, 50 Hz, 3 phase, Make-L&T/Scneider/siemens
Supply and Fixing in replacement of Electronic relay suitable for 20 HP Pump set starter, 415 volt, 50 Hz, 3 phase, Make-L&T/Scneider/siemens
Supply and fixing in replacement of star coupling of rubber for motor pumpset of capacity 03 to 40 HP complete all as specified & as directed by Engr-in-charge.
Supply, laying, jointing, testing and commissioning LT XLPE insulated, PVC sheathed armoured heavy duty electric cables LT 1100 volt grades with aluminium stranded conductor passing through pipes, in duct, on poles,in trenches, under road etc complete all as specified and directed of 10 Sqmm 4 core
All as sl item No.49 above but 25Sqmm 4 core
All as sl item No.49 above but 50 Sqmm 3.5 core
M & L Taking out u/s rusted corroded GI / PVC pipe of size 20 mm dia after cutting/unscrewing including all fittings from trenches /along walls/under road etc complete all as specified and directed.
SM CONSTRUCTION COMPANY
M/S Shree Ram Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .