Accessories Division, Lucknow
HINDUSTAN AERONAUTICS LIMITED Accessories Division, Lucknow Post Office, Lucknow - 226 016 Uttar Pradesh, India
Electrical works in extension of DGAQA office in Factory
8746
HAL-ADL/9995/DGAQA-EXT/196
Works
Accessories Complex - Lucknow Divn - Plant Maintenance
₹0
₹11,156
9 Aug 2024
20 Jul 2024
20 Jul 2024
9 Aug 2024
HINDUSTAN AERONAUTICS LIMITED ACCESSORIES DIVISION, LUCKNOW PQ FORM/ELIGIBILITY CRITERION-MATRIX
NAME OF THE WORK: "Electrical works in extension of DGAQA office in Factory "
Estimated Cost (in Rs.) 557,750.65
S# Intending bidders must meet the following eligibility criterion:
1 Name of the Individual / Firm / Company: * Mandatory
2 Type of ownership Pvt. Ltd./ Proprietorship/Partnership/ Public limited/ Govt. Agencies/ Trust If Other, please specify
3 Details of Constitution or Legal Status such as certificate of incorporation, shops and establishments, Contractor registration No etc.,
4 Address of Correspondence
5 Contact Details: Contact person name: Designation: Mobile No:. Ph. No. with STD code: Email Id :
6 Contractor must give his acceptance to provide services as per ‘Requirement, Scope of work, Drawings’ and ‘Terms & Conditions' contained in Technical Bid.
7 Self attested copy of PAN/GIR No. Registration certificate issued by income tax authority.
8 Self attested Copy of GST Registration Certificate.
9* Average annual turnover during the last 3 years, ending 31st March of previous financial year, should be at least 30% of the approximate estimated amount put to tender. Profit & loss statement duly certified by chartered accountant with UDIN shall be considered for evaluation of turnover for the respective financial Year i.e. Fin Year 2020-21,2021-22 & 2022-23 167,326.00
10* Valid “A” class Electrical contractor licence of appropriate voltage issued by any state Govt.
11* The Solvency required will be 40% of the approx. estimated amount put to tender. The solvency certificate shall be from a nationalized or scheduled bank and issued within a period of 12 months from the final date of Submission of tender.(in Rs.) 223,101.00
12* EMD amount (in Rs.) 11,156.00
13* Self attested Copy of PF Code Certificate(if applicable).
14* Self attested Copy of ESI Number certificate (if applicable).
15* Experience of having successfully completed similar works as indicated in the work details during last 7 years ending last day of month previous to the one in which applications are invited should be either of the following (in Rs.):-
i Three similar completed each work costing not less than 40% of estimated amount. OR 223,101.00 PO no.: Value : Completion Date: Customer:
223,101.00 PO no.: Value : Completion Date: Customer:
223,101.00 PO no.: Value : Completion Date: Customer:
ii Two similar completed work costing not less than the amount equal to 50% of the estimated cost. OR 278,876.00 PO no.: Value : Completion Date: Customer:
278,876.00 PO no.: Value : Completion Date: Customer:
iii One similar completed work costing not less than the amount equal to 80% of the estimated cost. 446,201.00 PO no.: Value : Completion Date: Customer:
25 DECLARATION I ACCEPTED/NOT ACCEPTED
The document being viewed / downloaded from the website and having read & understood all the contents of the tender document mentioned under terms and conditions including price bid do hereby accept all the terms and conditions laid down in the said Tender document and will abide by the same on acceptance and ward of work.
26 DECLARATION II ACCEPTED/NOT ACCEPTED
I/We declare and confirm that - 1. All information and attachments submitted along with this offer are true and correct. 2. I/We are aware that any false information provided herein will result in the rejection of my offer . 3. I/We shall not make refund claims of expenditure incurred in processing this offer. 4. I / We aware that document sought only be uploaded for evaluation of offer. 5.I/We are not debarred / blacklisted from any Govt agencies, if debars for specified period reason for debar and copy of resumption of same shall be provided. 6. I/We have not concealed any information which may adversely effect my qualification.
27 DECLARATION III COMPLIED/NOT COMPLIED
I/We declare and confirm that all the documents related to NIT mentioned at SI.No.2 and 3 have been attached with the technical bid.
Name of Bidder:
* 1. To be filled by Bidder essentially and carefully. Supporting documents must be attached as proof. Clarifications shall be sought w.r.t. information provided with tender documents. 2. Similar works implied that works related to HT/LT related new/repair/Maintenance Electrical Works in nature. Mere supply of electrical goods does not mean qulification in the tender. 3. Scanned copy of completed work orders and completion certificate issued by respective clients to be attached. If the completion certificate is from private organization the same shall be uploaded with TDS certificate. 4. The work shall be completed as a whole, Partial value/completion will not be considered. 5. The Bidders are requested to attach scan copies of all the relevant / desired / required proofs/ documents on e-portal, failing which tender shall be summarily rejected without assigning any reason to bidders.
HINDUSTAN AERONAUTICS LIMITED Accessories Division, Lucknow Price Bid
NAME OF THE WORK: “Electrical works in extension of DGAQA office in Factory”
Sl.No. DESCRIPTION OF WORK UNIT QTY RATE (INR) AMOUNT (INR)
1 (a) Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit including all accessories such as bends, J.B,tees, ceiling rose, modular or angle holder (for light points),modular stepped type regulator etc. (for fan points) required for point wiring work with modular switch, modular plate with frame, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. The pipe shall be laid concealed in wall; partially it may be flush to the wall as per site requirement. Wire Make: Havells/Finolex/Polycab/L&T Conduit Make (Heavy Duty): AKG/GM./CAP/Anchor Switch/Socket Make: GM/Honeywell(MK)/Schneider Electric/Legrand/L&T/ROMA (Blank plates shall be used as per site requirement) Nos. 30 1506.29 45,188.70
(b) Add to the above Item-1 for each addition on only light points on the same switch circuit including all materials required for such wiring work. Nos. 20 1506.29 30,125.80
2 Supply & making One (half point) with 5 pin, 6 Amps socket controlled by 6 Amps switch modular type on the same board with other switches with 1.5 sqmm, PVC. insulated,copper FRLS type conductor, multi stranded wire. Nos. 15 131.43 1,971.45
3 S & F of wiring for circuit/submains wiring alongwith earth wire with the following sizes of FRLS is PVC insulated copper conductor, single core cable in surface/ recessed as required. The pipe shall be laid concealed in wall; partially it may be flush to the wall as per site requirement. Make of Wire: Polycab/Finolex/L&T/Havells PVC Heavy duty Conduit: AKG/GM/CAP/Anchor
(a) 2 x 1.5 sq. mm (Red/Yellow/Blue) + 1x1.5 sq. mm earth wire (Green Color) Mtr. 150 239.24 35,886.00
(b) 2 x 4.0 sq. mm (Red/Yellow/Blue) + 1x4 sq. mm earth wire (Green Color) Mtr. 75 342.95 25,721.25
C) 1x1.5 Sq mm Inverter wire (White Color) Mtr. 150 46.21 6,931.50
4 Supply & making One independent domestic power point with 5 pin, 6/16A or 20A (for AC) modular socket controlled by 16/20 Amp or 25A (for AC) SP MCB modular type, with 4.0 sqmm P.V.C. insulated, copper FRLS conductor, multi stranded wire 1100/660 Volts grade in heavy duty P.V.C. pipe of including all accessories required for making power point/AC point such as modular cover plate with frame, P.V.C. pipe accessories, suitable size G.I. Box etc. The pipe shall be laid as per site requirement i.e. it may be concealed in floor/wall or flush to the wall. 2.5 sq.mm PVC insulated, single strand, copper FRLS wire shall be used in pipe with others wires for earthing of complete point wiring. Wire Make: Havells/Finolex/Polycab/L&T Conduit Make (Heavy Duty): AKG/GM./CAP/Anchor Switch/Socket Make: GM/Honeywell(MK)/Schneider Electric/Legrand/L&T/ROMA (Blank plates shall be used as per site requirement) Nos. 15 2727.14 40,907.10
5 Supply & installation of LED Light Fitting, 4 feet x 34-38 watt twin T-8 LED tube complete fitting to be installed on ceiling or hanging from ceiling by m.s pipe/suspension wire or fixed on wall with all necessary fixing materials and arrangement. The work also includes connection from ceiling rose to fitting with twin core, white color flat flexible cable 1100/660 Volts grade. All material required for the work shall be supplied by the contractor. The work shall be done as per direction of engineer incharge. Make: Crompton/Philips Nos. 10 2161.02 21,610.20
6 Supply and installation of indoor type LED mirror with warm white color light with clamps and integrated LED as per following specifications:- Finish- Chrome Material- Chrome plated MS with PC diffuser Color rendering index- not more than 80 Lumen- 1000 Lm IP44, Warranty- 1 Year Premium reputed make Sample to be provided for finalization Nos. 2 2110.17 4,220.34
7 Supply and installation of recess mounting 36 watt-40 watt LED luminaire of size 2 feet x 2 feet complete fitting. The work must be done as per direction of Engineer-In-Charge. The work also includes connection from ceiling rose to fitting with twin core cable, 1100/660 Volts grade make:- Polycab/Finolex /Havells. All material required for the work shall be supplied by the contractor. Warranty card of fitting duly filled and stamped by dealer is to be submitted to engineer incharge. The work shall be done as per direction of engineer incharge. Make: Crompton/Philips Nos. 40 2711.86 108,474.40
8 Supply and fixing of TP&N distribution board with Double Door 6 way per phase (LDB),make: Legrand/Havells/Crompton/L&T with supply and fixing of following MCBs C-Curve and Isolator Legrand/Havells/L&T make, making connection and testing as per direction of EIC . Make: Legrand/Havells/L&T/Siemens/Schneider Electric Set 1 11,672.50 11,672.50
Isolator TPN 63A - 01 No.
MCB SP 10A - 10 Nos.
MCB SP 16A - 8 Nos.
9 Supply and fixing of TP&N distribution board with Double Door 6 way per phase (PDB)with supply and fixing of following MCBs C-Curve and Isolator making connection and testing as per direction of EIC . Make: Legrand/Havells/L&T/Siemens/Schneider Electric Set 1 11,672.50 11,672.50
Isolator TPN 63A - 01 No.
MCB SP 16A - 10 Nos.
MCB SP 25A - 8 Nos.
10 Supply, laying(underground), connection and testing of under noted size of aluminium conductor, XLPE insulated, PVC sheathed, steel armoured 1100 volts grade power distribution cables conforming to IS7098 part I 1988, by digging earth 85+/- 5cm depth, 25 cm width and supply & laying adequate sand and new class 'II' bricks for protection of cable, filling earth, leveling etc as per standard code of practice as per direction of EIC. Make Havells/Finolex/Polycab/Gloster
11 Making End Termination of 1100 V grade XLPE insulated and PVC sheathed armoured Aluminium conductor cable of following sizes with Supply & Fixing of Lugs & Glands as per direction of EIC. (make: Raychem/3M)
12 Supply of UL listed CPRI tested maintenance free copper bonded earth rod of 3.048 m. having diameter of 17.2 mm with 254 micron copper bonding tested 45kA peak short-circuit current with clamp made of stainless steel for terminating cable/flat conductor. Earth enhancing material (PROCEM) compound (electrical resistivity 0.018 ohm metre) 25 kg tested for LEACHING and TCLP with NABL accredited LAB. The systems is conforming to IS3043, IS/IEC62305, IEC61643-5-54,UL467,the rod has to be tested for dimension, marking, tensile strength, salt mist, coating thickness, electrical resistivity test before and after corosion test etc. as per IEC 62561-2. Chamber inspection pit made up of PP material can bear 60kN load. Set consists of following BoM:- 1. Earth rod of 3 metre length having the dia of 17.2 mm 2. PROCEM 12.5 (25 Kg.) 3. Universal SS clamp 4. Pit Cover Make: CAPE/JEF/OBO Nos. 2 7080 14,160.00
13 Supply and laying of 6 SWG GI wire for earth connection to MCB DB. The work includes bending, cutting, connecting etc. as per site requirement. The wire shall be properly supported. Complete job. Work is to be done as per the direction of engineer in charge. Mtr. 50 52.37 2,618.50
14 Supply and laying of GI strip 25*5mm for earth pit connection to pedestal DB. The work includes bending, cutting, connecting etc. as per site requirement. The wire shall be properly supported. Complete job. Work is to be done as per the direction of engineer in charge. Mtr. 60 250.54 15,032.40
15 Supply and fixing LED flood light fitting 70W 230V AC outdoor type with high pressure die cast Aluminium housing and heat resistant complete with driver, rod for fitting, lamp brackets with impact and corrosion resistant including thermal resistant in multiple optics complete with IP67 protection complete. Make: Havells/OSRAM/Philips/Crompton/Wipro Nos. 5 5308.32 26,541.60
Sub-Total 472,669.76
TOTAL AMOUNT 557,750.32
% ABOVE/BELOW FROM TOTAL AMOUNT
NAME OF THE BIDDER:
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
raw.json
RAW_JSON
NIT.pdf
TENDER_DOCUMENT • 3.33 MB
ELIGIBILITYCRITERIONMATRIX.xlsm
TENDER_DOCUMENT • 0.01 MB
PRICEBID.xlsm
TENDER_DOCUMENT • 0.01 MB
TECHNICAL_BID.pdf
TENDER_DOCUMENT • 1.02 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .