| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.7 CrAdmitted-Finance | ₹6.7 Cr | L1 | Admitted-Finance |
| 2 | L2₹7.0 Cr+₹37.2 L (5.57%)Admitted-Finance | ₹7.0 Cr+₹37.2 L (5.57%) | L2 | Admitted-Finance |
| 3 | L3₹7.3 Cr+₹61.9 L (9.28%)Admitted-Finance | ₹7.3 Cr+₹61.9 L (9.28%) | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M Gunananda Sharma L2 | Andy Pamei L1 | Irom Khogen Singh L3 |
|---|---|---|---|---|---|---|
| 1.00(A) MAIN BUILDING | ||||||
| 2.00EARTH WORK | ||||||
| 3.00 | Earthwork in excavation foundation trenches or drains including dressing of sides and ramming of bottoms and including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m. (a) Lift upto 1.5 m | 128.02 | m3 | 191 ₹24,451.82 | 164 ₹20,995.28 Lowest | 209 ₹26,756.18 |
| 4.00 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm.in depth, consolidating each deposited layer by ramming and watering lead upto 50 metres lift upto 1.5 metre. | 42.67 | m3 | 157 ₹6,699.19 | 130 ₹5,547.1 Lowest | 175 ₹7,467.25 |
| 5.00 | Filling in plinth with sandy soil under floors including watering ramming,consolidating and dressing complete with a lead of 15 Km | 300.52 | m3 | 1,027 ₹3,08,634.04 | 1,000 ₹3,00,520 Lowest | 1,045 ₹3,14,043.4 |
| 6.00CONCRETE WORK | ||||||
| 7.00 | Providing and laying cement concrete works in foundation and plinth excluding the cost of centering & shuttering in (a) C.C. 1:5:10 (1 cement :5 Kanaighat coarse sand :10 graded stone aggrt. 40mm nominal size). | 75.4 | m3 | 7,927 ₹5,97,695.8 | 7,900 ₹5,95,660 Lowest | 7,945 ₹5,99,053 |
| 8.00REINFORCED CEMENT CONCRETE WORK | ||||||
| 9.00 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1.5:3 (1 cement :1.5 Kanaighat coarse sand:3 graded stone aggregate 20 mm nominal size.) | 183.5 | m3 | 11,830 ₹21,70,805 | 11,803 ₹21,65,850.5 Lowest | 11,848 ₹21,74,108 |
| 10.00 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5 Kanaighat coarse sand:3 graded stone aggregate 20 mm nominal size.) | 275.66 | m3 | 13,779 ₹37,98,319.14 | 13,752 ₹37,90,876.32 Lowest | 13,797 ₹38,03,281.02 |
Tender Value
₹5.6 Cr
EMD Value
₹11.2 L
Closing Date
4 Oct 2021, 1:00 pmClosed
Executive Engineer (I/E)
MPHC office Complex
Construction of Hill Tribal Chiefs Guest House at Palace Compound, Imphal East under Schemes of North Eastern Council.
2021_MPHCL_1540_1
02/EE(I/E)/MPHC/2021-22
Open Tender
Civil Works
Works
548 days
as per tender document
As per tender documents
11 documents required · 11 mandatory
₹25,000
MD MPHC Ltd.
₹11.2 L
Yes
27 Jul 2023
17 Sept 2021
4 Oct 2021
18 Sept 2021
4 Oct 2021
22 Sept 2021
19 Sept 2021 - 29 Sept 2021
Amount
(A) MAIN BUILDING
EARTH WORK
Earthwork in excavation foundation trenches or drains including dressing of sides and ramming of bottoms and including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m. (a) Lift upto 1.5 m
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm.in depth, consolidating each deposited layer by ramming and watering lead upto 50 metres lift upto 1.5 metre.
Filling in plinth with sandy soil under floors including watering ramming,consolidating and dressing complete with a lead of 15 Km
CONCRETE WORK
Providing and laying cement concrete works in foundation and plinth excluding the cost of centering & shuttering in (a) C.C. 1:5:10 (1 cement :5 Kanaighat coarse sand :10 graded stone aggrt. 40mm nominal size).
REINFORCED CEMENT CONCRETE WORK
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1.5:3 (1 cement :1.5 Kanaighat coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5 Kanaighat coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1.5:3 (1 cement :1.5 Kanaighat coarse sand:3 graded stone aggregate 20 mm nominal size.)
Providing R.C.C. eave board 40 mm thick and 15 cm to 30 cm wide in 1:1.5:3 (1 Cement: 1.5 Kanaighat coarse sand: 3 graded stone aggregate 10 mm nominal size) upto floor five level i/c finishing and plastering of thickness not exceeding 6 mm on exposed surface to give a smooth and even surface, centering and shuttering but excluding cost of reinforcement.
Providing Cast-in-situ reinforced cement concrete under reamed piles of 1:1.5:3 (1 cem:1.5 Kanaighat coarse sand c/sand:3 gr.st.aggrt 20 mm n/size) of 45 cm bore dia with two under reamer ( two and half time the bore dia) and of length 19.00m from existing G.L i/c reinforcement complete as per drawing and technical specifications
Providing Cast-in-situ reinforced cement concrete under reamed piles of 1:1.5:3 (1 cem:1.5 Kanaighat coarse sand c/sand:3 gr.st.aggrt 20 mm n/size) of 45 cm bore dia with single under reamer ( two and half time the bore dia) and of length 19.00m from existing G.L i/c reinforcement complete as per drawing and technical specifications
Conducting Pile load test as per IS 2911 Pt-IV for calculation of safe load capacity of pile i/c mobilisation and demobilisation of all requisite machineries and equipments along with submission of reports etc. complete as per direction of the Engineer - in-charge
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete.(a) Mild steel and Medium Tensile steel bars.
(b) Thermo-Mechanically Treated bars.
FORMWORK
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain concrete work in.(using 12mm shuttering ply)(a) Foundation footings, bases of columns etc. and mass concrete.
(b)Columns, pillars, posts and struts (square, rectangular or polygon in plan
(c) Sides and soffits of beams, beam haunchings, cantilivers, girders, bressumers and lintels not exceeding 1m in depth.
(d)Flat surface such as suspended flloor,roofs, landing & the like (i) floor etc upto 200mm in thickness
(e)Edges of slab and breaks in floor not exceeding 1m in depth
(f) Staircase (e/c landing) slopping or stepped soffits i/c riser and strings etc.
(g) Columns, pillars, posts and struts (Circular or curved in plan)
(h)Vertical surface such as walls (any thickness), partition and the like i/c attached pilasters, buttresses, plinth and the string courses and the like
BRICK WORK
Half brick masonry 2nd class (local first class) in cement mortar 1:4 (1 cement : 4 Kanaighat coarse sand) in superstructure.(i) Above plinth level upto 1st floor level.
(ii) Above 1st floor level upto 2nd floor level
(iii) Above 2nd floor level upto 3rd floor level
(iv) Above 3rd floor level upto 4th floor level
2nd class (local first class) brick work in foundation and plinth in cement mortar 1:4 (1 cement : 4 Kanaighat coarse sand)
WOOD WORK
Providing wood work in frames of doors, windows, c/windows & other frame and fixed in position.(a)Local best quality Teak wood.
Extra for additional labour for circular works such as in frames of fan light. (a) Local best quality Teak wood.
Providing and fixing 38mm thick panelled and glazed or panelled and glazed shutters for doors, windows, c/windows ect. Including bright finished brass hinges with necessary screws-(a) Local best quality Teak wood.
Providing 40x3mm flat iron hold fast 40cm long i/c fixing to frames with 10mm dia bolts, nuts and wooden plugs and embedding to cement concrete block 30x10 x15cm 1:3:6 (1 cement : 3 Kanaighat coarse sand : 6 stone aggrt. 20mm nominal guage).
Providing and fixing 25mm thick block board with commercial ply shelves/racks, partitions etc. for cup-board as per design , drawing and direction of Engineer-in-charge.
Providing & fixing M.S. grills of required pattern to wooden frames vertically and horizontally with M.S. flats at required spacing & frames based on Architectural drawing .. i/c priming,painting etc. Complete as per direction of Engineer-in-Charge.
Providing and fixing Brass sliding bolts bright finished or black enamelled with nuts & screws etc. complete. (a) 300 x 16 mm
P/F Brass Tower bolts with screws & nuts complete,(a) 250x10 mm
P/F Brass Handles with screws & nuts complete,(a) 125mm
STEEL WORKS
Providing & fixing M.S. round holding down or anchor bolts with nuts & washer plates complete.
Providing & fixing in position collapsible steel shutters with vertical channels 20 mm X 10 mm X 2 mm & braced with flat iron diagonals 20 mm X 5 mm sizes with top & bottom rails of T iron 40 mm X 40 mm X 6 mm with 38 mm dia steel pullets complete with bolts & nuts, looking arrangement, stoppers, handles i/c applying a priming coat of red lead paint.
FLOORING
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4(1 cement: 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm (Branded Double charged )
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.(a) Size of Tile 600x600 mm (Double Charged) (i) Branded.
Granite stone slab flooring over 20 mm (average) thick base of cement mortar 1 : 6 (1 Cement: 6 Kanaighat coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with -(a) Granite slab 20 mm slab thick (i)Jade Black 60 x 120 cm
ROOFING & CEILING
Trepezoidal pre- painted profile sheet roofing of approved brand dyna roof or equivalent with selt driling srews of 68 mm long xylon coats screws with pvc washer and caps complete excluding the coat of purlin and truss. A) pre painted galvalume sheet (PPGL) (i) profile sheet 0.50 mm 4.2 kgs per SQM
Trepezoidal pre- painted profile sheet roofing for ridges /gutter or valley 610 mm wide approved brand dyna roof or equivalent fixed with selt driling srews of 68 mm long xylon coats screws with pvc washer and caps complete excluding the coat of purlin and truss. A) pre painted galvalume sheet (PPG) (i) profile sheet 0.50 mm 4.2 kgs per SQM
Providing and fixing 12 mm thick gypsum board false ceiling at all height with GI channel and GI wire at every junction ,recommended jointing compound, jointing tapes on both side of joint and two coat of primer suitable for board i/c the cost of making openings for light fitting etc all complete as per drawing, specification but excluding the cost of painting and as per direction of the Engineer-in-charge
TUBULAR TRUSSES /STEEL /ALUMINIUM WINDOWS
Steel work in built up tubular trusses including cutting, hoisting, fixing in position and applying a coat of approved steel primer red oxide chrome primer conforming to IS 2079, welded and bolted incluiding special shape washer etc. complete. (a) Electric resistant welded tube 9 Conforming to IS : 1611 - 1979).
Providing and fixing stainless steel railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge.
Providing and fixing Stainless steel railing made of Hollow tubes, rounded mitred ends to top of newels.
FINISHING
12mm cement plaster 1:4 (1 cement : 4 Kanaighat coarse sand).
15mm cement plaster 1:4 (1 cement : 4 Kanaighat coarse sand).
Painting on wall with (two coats) of Dulux Acrylic emulsion(Supreme 3 in 1) paint or equivalent of approved quality in all shades on new work to give an even shade.
Providing and applying plaster of paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete.
Applying one coat of cement primer of approved quality on wall surface.
Finishing wall weather shield paint of approved quality on new work (three or more coats) to give an even shade.
Applying ready mixed priming coat (genuine red lead of appd. Quality) on steel work.
Applying ready mixed priming coat pink primer of approved quality on wood work.
Painting (two or more coats excluding priming coat) with superior ready mixed paint for steel work of approved quality in all shades on new steel work to give an even shade.
Painting (two or more coats excluding priming coat) with superior ready mixed paint for wood work of approved quality in all shades on new wood work to give an even shade.
MISCELLANEOUS
Providing under layer for plinth protection of 75 mm thick (unconsolidated) of stone aggrt. 40 mm nominal size wall rammed & consolidated & grouted with fine sand i/c finishing the top of concrete smooth.
Providing plinth protection 50 mm thick in cement concrete 1: 3 : 6 (1 cement : 3 Kanaighat coarse sand : 6 graded stone aggrt. of 20 mm nominal size) i/c finishing the top surface of concrete smooth.
2nd class brick masonary 15x15cm open surface drain in c.m. 1: 5(1cem : 5 c/sand) i/c earth excavation 10cm bed c.c.1: 5 : 10 1cem : 5 c/sand (Kanaighat) :10gr.st.aggrt.40mm n/size i/c 12mm thick cement plaster 1: 3 (1cem : 3 c/sand) with a floating coat of neat cement inside & outside as per standard design.
(B) WATER SUPPLY AND SANITARY INSTALLATION
Earth work in excavation in foundation trenches or drains i/c dressing of sides and ramming of bottoms,including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead to 50 m.in Hard dense soil. (a) Lift above 1.5 m
Filling available excavated earth (excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming & watering lead upto 50m and lift upto 1.5m.
P/L cement concrete in foundation and plinth excluding the cost of centering and shuttering : - (a) 1:5:10 (1 cem :5 kanhaighat Coarse sand: 10 graded stone aggrt. 40mm nominal size).
(b) 1:2:4 (1 cem :2 kanhaighat Coarse sand:4 graded stone aggrt.20mm n/size).
2nd class (local first class) brick work in foundation and plinth in cement mortar 1: 4 (1 Cem:4 kanhaighat C/Sand)
Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering,finishing and reinforcement- All work upto plinth level(a) 1:1.5:3 (1 cement : 1.5 kanhaighat coarse sand : 3 graded stone aggrt. 20mm nominal size).
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1:2 (1 cement :1 Kanhaighat coarse sand:2 graded stone aggregate 20 mm nominal size.)
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain concrete work in. (a) Foundation footings, bases of columns etc. and mass concrete.
(b) Flat surfaces such as suspended floor, roofs landings and the like (i) floors etc. upto 200mm in thickness.
(c ) Edges of slab and breaks in floors and walls (i) Under 20cm wide
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.(a) Thermo-Mechanically Treated bars.
15 mm cement plaster 1:3(1 cement:3 coarse sand)finished with a floating coat of neat cement.
Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge.
Providing and fixing wash basin with C.I. brackets, 15mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- (i) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer
Providing and fixing 600 X 20 mm C.P. brass towel rail complete with C.P. brass brackets fixed to wooden cleats with C.P.brass screws(Hook type).
Providing and fixing 600 x 450 mm bevelled edge mirror with frame of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete
Providing and fixing liquid soap container of glass with C.P. lid and brackets fixed to wooden cleats with C.P. brass screws.
Providing and fixing MS holder bat clamps of approved design to 100 mm HCI pipe socket i/c cost of cutting holes and making good the walls etc.
Providing and fixing UPVC soil, waste, rain water and vent pipes including all requisite fittings, jointing of pipes & fittings with solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in charge(i)110mm dia.
(ii) 75mm dia.
Providing and fixing PVC traps with 100 mm inlet and 75 mm outlet of self cleaning design with screwed down of hinged grating with or without vent arm complete i/c cost of cutting and making good the walls and floors.
Providing and fixing 100 mm HCI terminal guard.
Providing and fixing C.I. cover with frame for (manhole and chamber). (a) 600 X 450 mm (Heavy duty) ( 38 kg).
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc.(a)15 mm nominal outer dia Pipes
(b) 25 mm nominal outer dia Pipes
(c ) 32 mm nominal outer dia Pipes
Providing and fixing brass bib cock of superior quality.(a) 15 mm diameter (Ordinary)
Providing and fixing brass stop cock of superior quality (a) 15 mm diameter
P/F Brass full way G.M valve with C.I wheel of superior quality (a) 32mm diameter
Providing and fixing WATER STORAGE TANKS (Sintex) with 400 mm diameter nominal base G.I. overflow tube 25 mm nominal G.I. inlet and 15 mm nominal G.I. outlet tube including hoisting a height of 10 m above ground level.(a) 2000 litres net capacity storage tanks.
(C) Ground Sump 20000 litre Capacity
Earth work in excavation in foundation trenches or drains i/c dressing of sides and ramming of bottoms,including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead to 50 m.in Hard dense soil. (a) Lift above 1.5 m
Filling available excavated earth (excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming & watering lead upto 50m and lift upto 1.5m.
P/L cement concrete in foundation and plinth excluding the cost of centering and shuttering : - (a) 1:5:10 (1 cem :5 kanhaighat Coarse sand: 10 graded stone aggrt. 40mm nominal size).
Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering,finishing and reinforcement- All work upto plinth level(a) 1:1.5:3 (1 cement : 1.5 kanhaighat coarse sand : 3 graded stone aggrt. 20mm nominal size).
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1:2 (1 cement :1 Kanhaighat coarse sand:2 graded stone aggregate 20 mm nominal size.)
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain concrete work in. (a) Foundation footings, bases of columns etc. and mass concrete.
(b) Flat surfaces such as suspended floor, roofs landings and the like (i) floors etc. upto 200mm in thickness.
(c ) Edges of slab and breaks in floors and walls (i) Under 20cm wide
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.(a) Thermo-Mechanically Treated bars.
15 mm cement plaster 1:3(1 cement:3 coarse sand)finished with a floating coat of neat cement.
(D) Development works i/c Approach Road
Banking excavated earth in layers not exceeding 20 cm in depth, breaking clods, watering, rolling each layer with 1/2 tonne roller or wooden or steel rammer and rolling every third and topmost layer with power roller of minimum 8 tonne and dressing up in embankment for roads marginal banks flood banks and guide bank lead upto 50 metres and lift upto 1.5 metre
Providing laying & compacting granular base/sub-base according to lines, grades& cross-sections by using naturally occurring sand gravel/ conforming to IRC Grade 2 of M.O.S.T. specification free from organic or other deleterious constituents compact by rolling with power roller of 8 to10 tonnes capacity in layers not exceeding 150 mm (spread thickness) including rolling of the road surface to proper level & grade 30 cm width edging on both sides etc. complete as directed by the Engineer-in-charge. ( with carriage charge of all materials)
Providing and laying one layer W.B.M. 7.5 cm consolidated thickness using 1 cum of stone aggregate conforming to IRC Grades per 10 sqm of road surface & 0.23cum of binder materials of approved quantity per 10 sqm of road surface including consolidating of the same, rolling of the surface to camber, superelevation & grade by using template straight edges & spirit level in layers not exceeding 100 mm to 130 mm thick (spread thickness), dry & wet rolling with 8 to10 tonne roller including earth edging 30 cm width on both sides & applying binding materials as specified (with carriage charge of all materials). (i) I.R.C. Grade -II
(ii) I.R.C. Grade - III
Preparing surface by brushing with wire brushes for remaining caked mud etc. sweeping with brooms and finally fanning the cleared surface with gunny bags to removed all loose dirt etc.(a) Water bound macadam surface new
Providing & applying evenly a priming/tack coat with bitumen (80/100).(a) 10 kg/10sqm
Providing and laying bituminous macadam of 50 mm as per clause 504.1 of "MOST" specification for base course with binder content @ 4% by weight of total mix including preparation of bases including filling of pot holes, cleaning the surface with wire brushes etc. and providing suitable edge supports heating of binder and aggregate handling of materials, screening, mixing, in hot mix plant conforming and transporting laying and finishing with paver finisher to the required level, grade and camber, rolling by power roller etc. complete including running expenses of all plants.
2 cm consolidated thick single coat pre-mix carpet surfacing with 0.27 cum stone chipping 12.5 mm size 0.18 cum and 10 mm size 0.09 cum mix with 14.6 kg of binder per 10.00 sqm of road surface and rolling complete including a seal coat IRC type "A" with 0.09 cum of stone chipping 6.3 mm nominal size and 9.8 kg of bitumen 80/100 per 10.00 sqm of road surface.
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with modular type switch phenolic laminated sheet suitable size MS-box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
(a) Group A
(b) Group B
(c ) Group C
Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in surface/recessed PVC conduit etc.as reqd.
(a) 2X1.5mm2+1X1.5mm2 earth wire
(b) 2X2.5mm2+1X2.5mm2 earth wire
(c ) 2X4mm2+1X4mm2 earth wire
(d) 2X10mm2+1X10mm2 earth wire
(e) 4X16mm2+2X16mm2 earth wire
Supply and fixing (following modular type switch/socket) on the existing modular plate and switch box i/c connection but excluding modular plate etc as reqd.
(a) 5/6 amps switch
(b) 15/16 amps switch
(c ) 3 pin 5/6 amps socket outlet
(d) 6 pin 15/16 amps socket outlet
Supply and drawing (following pair) 0.5mm2 FR PVC insulated copper conductor unarmoured telephone cable in the existing surface/ recessed steel/ PVC conduit as reqd.
Supply and drawing Co-Axial TV cable RG-6 grade 0.7mm solid copper conductor PE insulated shielded with file tinned copper braid and protected in PVC sheath in existing surface/recessed steel/PVC conduit as reqd.
S/F I.O Outlet Box for RJ 45
S/F brass batten/angle holder i/c connection etc.as reqd.
S/F 12W LED bulb.
SITC surface mounted LED downlighter with white powder coated Al.housing with intrgrated electronic driver 15 W 840 LHEAAGPIA2W012 complete with connection etc as reqd.(Havell's)
S/F call bell/buzzer suitable foe DC/AC single phase 230V complete as reqd.
S/F bell push modular type complete as reqd.
Installation of exhaust fan upto 450mm sweep in the existing opening i/c making the hole to suit the size of the above fan,making good the damaged, connection testing commissioning etc.as reqd.
S/F 12"(305mm) dia light duty exhaust fan complete with all accessories.
S/F fan hook i/c bolt & nuts.
S/F 48" sweep AC ceiling fan complete with down rod, blade, canopy & regulator i/c connection etc.as reqd.(Havell's Pacer) white/Brown/Ivory
S/F stepped type electronic fan regulator on the existing modular plate switch box i/c connection but excluding modular plate etc.
S/F Puro Plus water heater (Geyser) AC 2KW vertical type with accessories GHWAPFTIVO15/GHWAPFTW025 (Havells) i/c connection etc. as reqd. (Ivory)
S/F50 W LED 5000K energy saving IP 65 Flood Light luminaries with high power COB LED as light source Havell's LHEPBFUEIN6W050
S/F 25 amp Air-Conditioner power plug point i/c 4 modules metal box on surface or in recess 4 - modules plate and cover in front, 25 amp modular starter 25 amp modular socket outlet and 25 amp plug i/c connection etc. as reqd.
S/F 1.5 tone capacity split type air conditioner (Diamond, 3 Star, 5G 29, G-SC 18 FD 3 WJH) complete with Indo voltage Stabilizer, Automatic 4 KVA (140-280 for 1.5 ton)
Design, supply, installation testing and commissioning of L.T.Panel board of dust and vermin proof mounted with thickness of 16 SWG metal clad sheet with suitable for use at 3- Phase, 4 pole,50 Hz 415V fitted with the following switch gears of six way outgoing conforming to IS/IEC:60947-2, HSN Code 8537 :-
1. 400 amp. TPN on load changeover switch - 1 No.
2. 400 amp. TPN bus bar chamber - 1 No.
3. 125 amp. TPN thermal adjustable MCCB - 6 Nos.
P/F (following rating and breaking capacity) MCCB in existing cubicle panel board including driling holes in cubicle panel & making connection as reqd.
(a) 4 pole MCCB 100 amp 16 KA
P/F following RCCB in existing cubical panel board i/c drilling holes in cubical panel making connection etc. as reqd.
(a) 63 amp. Four pole RCCB 100mA/300mA.
S/F bus bar chamber with 4 strips copper bus bar length 600mm suitable for 200 amp capacity complete with all accessories i/c connection earthing the body etc.as reqd.
S/F wall/floor mounted metal board of welded constn.fabricated with minimum 50mm X 50mm X6mm angle iron frame work with horizontal and vertical intermediate members of suitable angle/flat iron for mounting of switch gear i/c painting etc.
S/F (4+18 way) double door TPN prewired, sheet steel MCCB distribution board 240V on surface/recessed complete with loose wire box, terminal blocks, tinned copper bus bar, neutral link, earth bar, dinbar, detachable gland plate, interconnection, phosphatized powder painted i/c earthing etc. as reqd. (but without MCB/RCCB/Isolator).
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 63 amp
P/F of lightning conductor finial made of 25mm dia. 900mm long copper tube having 5-prong at top with 85mm dia. 3mm thich copper plate including holes etc. complete as required.
Fixing of lightning conductor finial 25mm dia. 900mm long copper/GI tube having 5-prong at top with 85mm dia. 3mm thick base plate i/c holes etc. as reqd.
P/F copper tape 20mmx3mm thick on parapet or surface of wall for lightning conductor as reqd.(for vertical)
P/F copper tape 20mmx3mm thick on parapet or surface of wall for lightning conductor as reqd.(for horizontal)
Earthing with copper plate 600x600xmm thick i/c accessories and providing masonary enclosure with copper plate having locking arrangement and watering pipes etc.(but without charcoal and salt complete as reqd.)
Extra for using salt and charcoal for G.I.plates or copper plate earth electrode as reqd.
P/F 4.00 mm dia copper wire on surface or in recess for loop earthing as reqd.
50mm2 3.5 core PVC ins.(heavy duty) Al.cond.armoured cable of 1.1KV grade of size not exceeding 25mm2 but not exceeding 125mm2 direct in ground i/c excavation sand, cushioning protective covering & refilling etc.as reqd.
Supply & Fixing swaged type steel tubular pole 8 mtr. Long as per 410 SP 14.conforming to IS 2713 (Pt.II) 1980 with bracket in cement concrete 1:3:6 (1:cement:3c/sand:6 gr. st. 40 mm n/size) foundation i/c excavation and refilling etc. as requred.
Supply and drawing of AB Cable of size (3x50 + 1x35) mm2
Fire Fighting.
Supplying & installation of dry powder(Stored Pressure) fire extinguisher suitable for fires involving combustible lide wood, paper, cloth etc. capacity: 4 kg (ISI marked).
Supplying & installation of carbon dioxide type fire extinguisher suitable for fires involving materials like oil, electric & delicate machineries) capacity: 4.5 kg (ISI marked).
Installation of PA System.
SITC of Power Amplifier 2000 watt AHUJA LXA200 i/c all accessoeies as reqd.
SITC Wireless Microphone Black AHUJA AWM-520V2 i/c all accessoeies as reqd.
SITC of Wire Microphone i/c all accessoeies as reqd.
SITC of 8.om, 250 watt Speaker (AHUJA) i/c all accessoeies as reqd.
Supply and drawing (following pair) 0.5mm2 FR PVC insulated copper conductor unarmoured telephone cable in the existing surface/ recessed steel/ PVC conduit as reqd.
M Gunananda Sharma
Irom Khogen Singh
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.44 MB
Documents.pdf
Tender Documents • 1.18 MB
Drawing.pdf
Additional Documents • 0.61 MB
Scheduleofmaterials.pdf
Additional Documents • 0.28 MB
BOQ_1707.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .