| 1 | L1₹36.5 LAccepted-AOC 448 MUZAFFAR AHMED STREET KOLKATA 700 016 | KOLKATA | KOLKATA | WEST BENGAL | 700016 | L1 | Accepted-AOC Stands Lowest | |
| 2 | L2₹37.4 L+₹81,766 (2.24%)Rejected-AOC 49 1 ISWAR GUPTA ROAD KOLKATA 700 028 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700028 | L2 | Rejected-AOC Stands 2nd Lowest | |
| 3 | L3₹37.4 L+₹82,501 (2.26%)Rejected-Finance | L3 | Rejected-Finance Stands 3rd Lowest | |
| 4 | L4₹38.4 L+₹1.8 L (5.01%)Rejected-Finance | L4 | Rejected-Finance Stands 4th Lowest | |
| 5 | L5₹42.0 L+₹5.4 L (14.9%)Rejected-Finance 00 BALITIKURI BALITIKURI NASKARPARA HOWRAH WEST BENGAL 711113 | HOWRAH | WEST BENGAL | 711113 | L5 | Rejected-Finance Stands 5th Lowest |
Tender Value
Refer Docs
EMD Value
₹77,848
Closing Date
26 Jul 2021, 1:30 pmClosed
Executive Engineer
Office of the Executive Engineer, Purba Medinipur Electrical Division, P.W.Dte, Tamluk, Hospital More
Augmentation of the existing substation for the proposed PSA plant for supplying Oxygen to COVID-19 patients at DH, TAMLUK ,Purba Medinipur.
2021_WBPWD_336507_1
PWD/EE/PMED/eNIQ-08/21-22
Open Tender
ELECTRICAL WORKS ORG
Item Rate
7 days
Tamluk
Please refer Tender documents.
5 documents required · 5 mandatory
₹77,848
Tamluk
12 Aug 2021
19 Jul 2021
28 Jul 2021
19 Jul 2021
26 Jul 2021
19 Jul 2021
22 Jul 2021
SITC of 11KV/0 .415KV ,750 KVA indoor type CRT Dry tramsformer having the following specifiction as per : l.S. 11171-1985 and l.S. -- 2026 , IEC 60076-1) Rated Power (based on AN cooling) 750 kVA. 2) Rated No-Load Voltage Ratio (HV / LV) 11 / 0.415 KV. 3) Rated Frequency 50 Hz, 4) Number of Phases 3 Nos 5) Material of Winding (HV / LV) -- CU / CU 6) Vector Group -- Dyn11 7) Connection (HV / LV) -- Delta / Star 8) Tapping Off Circuit 9)Type of Tap Changer -- Manually operated Off Circuit Tap Link 10) Tapping Range/Tap step -- +5% to -5% @ 2.5% 11) No. of Steps Nos. +2 / - 2 steps 12) For HV Variation / LV Variation -- HV Variation 13) Class of Insulation Class F/F(155) 14) Method of Cooling -- AN 15) Avg. Temp. Rise of Winding (HV / LV) Deg.C 90 / 90 16) Ambient Temp. (Max. / Mini. / Year / Day) Deg.C 50 / -5 / 20 / 30 17) No-Load Loss at Rated Voltage & Frequency (+15% IS Tol.) 1.75 kW 18) Full-Load Loss at Rated Current, at 75 Deg. C & at Principal Tap (+ 15% IS Tol.) not more than 7.50kW. 19) Total Loss at Rated Voltage at Principal Tapping, Rated Frequency & at 75 Deg. C (+10% IS Tol.) not mor than 9,25 KW OR AS PER ECBC Guidlines. 20) % Impedance at Rated Current, at 75 Deg. C &at Principal Tap (+ / - 10% IS Tol.) %5.00 21) No-Load Current at Rated Voltage & Frequency (as % of F.L.R.C.) % 0.90 22) Efficiencies at 75 Deg. C at Unity Power Factor (Reference vaule) a) At Full Load % 98.78 b) At 3/4 Full Load % 98.95 c) At 1/2 Full Load % 98.04 23) Regulation at Full Load at 75 Deg. C a) At Unity Power Factor % 1.00 b) At 0.8 Power Factor (Lagging) % 3.80 24) BIL (Insulation Level) : a) Full Wave Lightning Impulse Withstand Voltage (HV / LV) kV peak 75 b)Separate Source Power-Frequency Voltage Withstand (HV / LV) kV rms 28 / 03 25) Degree of protection of Enclosure IP IP23 26) Termination Arrangements HV/ LV --Cable box 27)Orientation between HV & LV Deg. 180 28)Fittings / Accessories -- Rating & Diagram plate, Base Channel, Earthing terminals, Lifting lugs & 3 PT -100 Sensors 29)Noise Level when measured at 1 Meter Distance 62 dB As per NEMA TR-1. Make- ABB/ CGL/Energypack/ Voltamp(Baroda)
Supply and laying of following cables 11 KV grade 3 core 240 sqmm Al armoured XLPE cable through the existing under ground trench .Make-R R KABEL/Gloster/Havells
1.1 KV grade single core 300 sqmm Al armoured XLPE cable.Make-R R KABEL/Gloster/Havells (From Trafo LT side to LT Panel)
c) l.l KV grade 4 core 300 sqmm Al armoured XLPE cable.Make-R R KABEL/Gloster/Havells (From LT Panel New Panel Room)
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials incl. Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & frtoisture-proof entry of XLPE/PVC armoured cables 1.1 KV grade single core 300 sqmm Al armoured XLPE cable
1.1 KV grade 4 core 300 sqmm Al armoured XLPE cable .
Supply and fixing heal shrink type HT jointing kits for 11 KV grade 3core 300 sqmm XLPE cable. (Make- Raychem/ approved by EIC)
SITC of cubical type L.T. Distribution panel board of appropriate size, wall mounted compartmentalized with maple arrangement having rigid & self supporting structure fabricated from 2 mm thick CRCA sheet steel with 50mm*50mm*6mm M/S angle frame. The panel board consisting of the following switches.Panel should be fabricated at the CPRI certified manufacturers and test reports to be submitted. A) Incoming Arrangement. 4 Pole ,415V, 1250 A, 50 Hz, 50 Ka SCC capacity for l sec mechanically draw out type microprocessor based Air circuit breaker .Make-LT, Cat No- SL96064 /Siemens/ABB).-1 Nos B)Bus Section: 415 V 2000 A. electrolyte grade (99.96%)tinned copper bus bar with vertical section of size-2X75mmX10 mm, +/-5% for Each Phase & neautral Bars,. All bus bar shall be fixed with FRP chair & the entire bars are insulated with PVC heat Shrinkaable sleeve of suitable size & color as per direction of E.I.C C) Outgoing arrangement: 1) 4 Pole ,415V, 630 A, 50 Hz, 50 Ka SCC capacity for l sec mechanically draw out type microprocessor based Air circuit breaker .Make-LT, Cat No- SL96061 /Siemens/ABB).-1 Nos —1no's 2)Switch disconnector fuse (panel mounting cubical type) 50HZ, 415 Volt 4 Pole 400 Amp with 3 nos 400,Amp DIN type HBC fuse link, L & T make . Cat No SK90480/ Siemens/ ABB —2 no's e) Supply and fixing of Multifunction Electronic meter including S&F of 3 nos 1600/5A capacity CTs Make-Kappa.Make-LT,Cat NO-303FDNB1-1 No f) S&F Danger board Inter Connection: All interconnection of switches & bus bar Shall be made with multi strand PVC insulated copper wire to be kept for Cable connection for main switches & the end of all connections Of metering panel to be finish with Copper socket by crimping method having Marked ferrule for indication. Earthing. A separate earth bolts/Bars - 2 Nos will be provided in panel board in both sides as per drawing. Cable Alley: Cable entry arrangement will be provided in the cubical panel in vertical position of appropriate size with 200 Amp capacity 2 way AC/DC make connector indicating phase & neutral for each outgoing main switches & gland plate must be placed at the bottom of the panel with detachable type as per direction of E.I.C. Painting. The complete panel board shall be painted by 2 coats of powder coated paint over two coats of R.O. primer of Approved make & brand & color as per Direction of E.I.C. Constructural Details: All'incoming & outgoing panel mounted cubical Switch disconnector fuse shall be housed in Respective compartment with hinged & gasketted Door at front. All doors shall have Panel lock Arrangement. The panel'shall be properly Gasketted to prevent ingress of dust & moisture & Remain. Busbar will be properly arrange & all Switches shall be fixed by M.S. nuts & bolts On angle /flat iron frame base.as per direction of E.I.C.
Earthing with Copper plate (610x610x3mm size) having weight of 9.84 Kg and 1 No. 25x5mm Copper strip (3.20 mt long) & 1 no. 6 sqmm PVC insulated stranded Copper wire (4 Mt long) incl. S & F 15 mm dia GI pipe (ISI-Medium) protection (4 mt. long) to be fillied with bitumen, partly under the ground level & partly above ground level to an average depth of 3.65 Mts. below the ground level and restoring the surface duly rammed incl. providing 3.0 mt long, 25 mm dia GI pipe (ISI-Medium) for periodic treatment, incl. providing masonery enclosure on the top of the earth electrode of overall size 86.36x86.36x46cm deep (below Ground level) complete with cemented brick work (1:6) of 25 cm width, duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56x35.56cm with locking arrangement, GI reducer and treatment of soil by using salt & charcoal or coke for plate electrode [ FOR TRANSFORMER NEUTRAL EARTHING ]
Earthing with 80 mm dia Gl pipe (TATA-Medium)x 3.0 Mtslong and 1 No. 65 mm x 8 mm galvanized 85 to 90 micron with olive green passivation (Hot Dip) steel strip(4 Mts. long). 20 mm dia x 125 mm long galvanized bolt,double nuts, double washers including finishing both ends by making holes etc. and S S F 80 mm dia Gl pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts
Supplying & fixing COPPER earth busbar of size 25 mm x 5 mm, 85 to 90 micron with olive green passivation on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with Gl bolts, nuts, washers, spacing insulators etc. as required
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 65 mm x 8 mm 85 to 90 micron with olive green passivation on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with Gl bolts, nuts, washers, spacing insulators etc. as required
Supplying & laying of 2X95sqmm single coreXLPE, unarmoured and stranded copper cable for connecting neutral bushing of transformer to the neutral busbar incl. appropriate copper socket and nuts & bolts as per direction of EIC
Extra for providing masonery enclosure on the top of the earthelectrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6)of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, Gl reducer including drilling of 46 nos. 12 mm dia holes on the Gl pipe
S & F switch disconnector fuse unit with SS enclosure (panel mounting cubical type) 415 Volt 4 Pole 400 Amp with 3 nos 400,Amp DIN type HBC fuse link, ( Make: L & T/ Siemens/ ABB) —1no's
S & F 40mmX40mmX4mm thick GI Angle iron support as a cable tray support for holding of cable tray on parapet wall of the building with necessary grouting on wall of all supports.
Supply & Fixing of 300 X 50 X 1.25 perforated GI cable tray with perforation notmore than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support. with 25mmx25mmx3mm angle support.
Supply & Fixing of perforated GI cable tray cross member with perforation not more than 17.5% suspended from ceiling with two nos. suspenders & 25x25x3mm angle iron for supporting the cross member incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support.
Dismantling of the esixting 400 KVA dry type transformer from the existing place and trnasporting it from Tamluk DH to Haldia SDH.
Electromech Engineers Co-Operative Society Ltd.
M/S N. C. HORE
JAYBEECO
CHAKRABORTY ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .