| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.9 LAccepted-AOC | L1 | Accepted-AOC LOWEST AND ACCEPTED | |
| 2 | L2₹55.0 L+₹6.1 L (12.5%)Rejected-AOC HOUSE NO 93 WARD NO 8 NEAR ISKON TEMPLE UDHAMPUR J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L2 | Rejected-AOC NOT LOWEST |
Tender Value
₹48.2 L
EMD Value
₹96,420
Closing Date
16 Sept 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (SOUTH) UDHAMPUR
GE (SOUTH) UDHAMPUR
PROVN OF TWO ADDITIONAL ROOMS IN IBEX COMPLEX AT HQ NORTHERN COMD AND CERTAIN REVENUE WORKS AND MINOR WORK UNDER GE (SOUTH) UDHAMPUR
2021_MES_468995_1
GE/S(U)-37/2021-22
Open Tender
Civil Works
Works
180 days
GE (SOUTH) UDHAMPUR
Refer as per tender documents
9 documents required · 9 mandatory
₹500
GE (SOUTH) UDHAMPUR
₹96,420
17 Dec 2021
18 Aug 2021
17 Sept 2021
18 Aug 2021
16 Sept 2021
2 Sept 2021
18 Aug 2021 - 28 Aug 2021
60 days
Amount
Demolition of cement concrete in ground floor and paving not exceeding 15 cm thickness below and above ground level complete all as specified and directed.
Demolition of reinforced cement work as in roof slabs (other than ground floors) beams staircases, landing chajjas, drop facia and similar suspended work complete all as specified and directed.
Dismantling wall and ceiling boards (Fiber, pulp, insulation, blankets) any thickness including covered fillets and supporting members at roof blankets complete all as specified and directed.
Demolition of brick work or stone masonry built in cement mortar, or cement line mortar including all quoins, arches pillars etc. complete all as specified and directed.
Surface dressing not exceeding 30 cm deep and averaging 15 cm in soft loose soil in road side berms including all necessary cutting/ filling and finished to reqd size/shape complete all as specified and directed.
Excavation in trenches not exceeding 2 M wide and not exceeding 2.5 M in depth for foundation complete all as specified and directed.
Anti-termite treatment of bottom and sides of excavation at the rate of 5 ltr of emulsion per square metre of surface area complete all as specified and directed by Engr-in-Charge.
Anti-termite treatment of the top surface of filled earth at the rate of 5 ltr of emulsion per square metre of surface complete all as specified and directed by Engr-in-Charge.
Anti-termite treatment of the soil under plinth protection at the rate of 5 ltr of emulsion per square metre of surface complete all as specified and directed by Engr-in-Charge.
Providing and injecting Along the external wall below concrete or masonry apron using Antitermite Treatment chemical emulsion @ 2.25 litres per running metre including drilling and plugging holes etc. in apron complete all as specified and directed by Engr-in-Charge.
Providing and injecting Antitermite Treatment of soil under existing floors using emulsion @ 1 litre per hole, 300 mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement:2 coarse sand to match the existing floors complete all as specified and directed by Engr-in-Charge.
Providing and injecting Antitermite Treatment at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150 mm centre to centre and sealing the same complete all as specified and directed by Engr-in-Charge. Note : Refer BOQ item No.7,8,9,10 & 11. The treatment work shall be carried through authorised agency only, and certificate for the same for warranty shall have to be furnished before submitting payment.
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Removing excavated soil to a distance exceeding 50 m and not exceeding 1.50 km out side defence land complete all as specified and directed by Engr-in-Charge.
PCC 1:4:8 type D-2 (using 40 mm graded aggregate) in foundation filling and mass concrete complete all as specified and directed.
Use & waste of form work sides of concrete foundations footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work, vertical or to batter complete all as specified and directed for fair finished surfaces.
Reinforced cement concrete Design Mix M-25 as in foundation including rafts, footing, plinth beams, bases for columns etc complete all as specified and directed.
Form work to sides of columns rough ,Pillars, postsm struts suare or rectangular finished surfaces of concrete complete all as specified and directed.
Reinforced cement concrete Design Mix M-25 as in columns, pillar, pier, posts etc complete all as specified and directed.
Formwork to soffits of suspended slabs such as roof slabs, landing and similar work not exceeding 200 mm thick complete all as specified and directed.
Reinforced cement concrete M-25 nominal mix as in slab supported on walls, beam and columns in floors, roofs landings, balconies etc. complete all as specified and directed.
Reinforced cement concrete (design mix) M-25 (using 20 mm graded aggregates) fins, fascias, louvres, parapets, and railings exceeding 60 cm in height, Is, balustrade and retaining structures complete all as specified and directed.
Flat form work to fins, louvers, facia and parapet wall for rough finished surfaces of concrete complete all as specified and directed.
Form work to sides and soffits of floor roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including supports, over hangers etc also splays between floor and beam etc complete all as specified and directed for rough finished surfaces of concrete flat.
TMT steel bars 10 mm dia and over cut to length bent to shape reqd including cranking bending spirally for hooping for columns hooking ends and binding with m.s wire annealed not less than 0.9 mm dia complete all as specified and directed. Note : Site for brick work may involve head load, contractor shallhave no claim on extra labour incurred in this account.
All as per ser item No 25 but 6 mm to 8 mm dia complete all as specified and directed.
All as per ser item No 25 but 5 mm dia and over up to and including 10 mm dia as in stirrups complete all as specified and directed.
Taking down cement plaster and raking out joints, hacking for key, scrubbing down with water built in cement mortar any description complete all as specified and directed.
Brick work with sub class "B" bricks straight or curved on plan exceeding 6 Metre mean radius in cement mortar 1:4 complete all as specified and directed.
Rendering 15 mm thick in CM 1:6 on brick work and finished even and smooth without using extra cement complete all as specified and directed.
Rendering 15 mm thick in CM 1:4 on brick work and finished even and smooth without using extra cement complete all as specified and directed.
Rendering 5 mm thick in CM 1:3 on ceiling and exposed surface of concrete finsihed even and smooth without using extra cement complete all as specified and directed.
New plaster surface of walls surface and applying two coat of plastic emulsion paint (Shed approved by GE) over two coat of wall care putty with one coat of primer complete all as specified and directed.
Preparation of new plaster surfaces of wall and applying two coats of weather proof exterior emulsion paint (APEX or equivalent) over a two coat of wall care putty with over a coat of primer up to G+3 floor height etc. complete all as specified and directed.
Preparing new ceiling surface and apply two coat of oil bound distemper over a coat of wall care putty with one coat of primer complete all as specified and directed.
Complete removal of existing treatment of wall surface and applying two coat of plastic emulsion paint (Shed approved by GE) over two coat of wall care putty and one coat of primer complete all as specified and directed.
Complete removal of existing treatment (using removal machine) including preparing surfaces of wall and applying two coats of weather proof exterior emulsion paint (APEX or equivalent) over a two coat of wall care putty with a coat of Primer up to G+3 floor height etc complete all as specified and directed.
Complete removal of existing treatment of wall two coat of wall care putty and applying two coats of plastic emulsion over a coat primers with complete all as specified and directed by Engr-in-Charge.
Hard core of guage not exceeding 63 mm deposited spread and levelled in layers not exceeding 15 cm thick watered and rammed to a true surface complete all as specified and directed.
Sand cushioning/filling under gloors or laying as per site requirement complete all as specified and directed.
75 mm thick PCC 1:4:8 type D-2 (using 40 mm graded aggregate) as in sub base of floor etc complete all as specified and directed.
50 mm thick PCC type B-2 1:2:4 (using 40 mm graded crushed stone aggregate) as in floors finish even and smooth without using extra cement complete all as specified and directed.
15 mm thick screed bed in cement mortar 1:6 for laying floor finishes under floor complete all as specified and directed.
Marble 20 mm thick machine cut, marble slab, (Makrana white), as in flooring, bedded jointed with grey cement slurry and pointed with white cement including cutting and polishing complete all as specified and directed.
Marble/granite 20 mm thick machine cut, marble/granite slab, (makrana/granite black/green), as in flooring, bedded jointed with grey cement slurry and pointed with white cement including cutting and polishing complete all as specified and directed.
Granite 20 mm thick machine cut, marble/granite slab, as in flooring, bedded jointed with grey cement slurry and pointed with white cement including cutting and polishing with matte finish complete all as specified and directed.
Griding and polishing (of any type) including pointing old marble surface, kota stone surface of any description with match colour of cement with admixture of pigmant to match with marble shad complete all as specified and directed by Engr-in-Charge.
Cement concrete 1:3:6 type C-2, 75 mm thick (using 20 mm graded stone aggregates) as in plinth protection finished fair and even with using extra cement complete all as specified and directed.
Framed work such as grill, gratings etc with ends of bars shouldered and/or riveted or forged in to spikes, framed guard bars, barred iron doors ladders framed, water tank stagging balusters and similar work confirming to Fe 290 Gde E-165 complete all as specified and directed.
First class hard wood plain solid straight chowkhats and frames and Design main doors Pannel shutter with wrought frmed on the solid rounded or chanbered put together with glue and pinned at joints including preservative treatment approved and complete all as specified and directed by GE.
150 mm brass barrel tower bolts, with cast or sheet and rolled or cast bolts complete all as specified and directed.
Brass, sliding door bolt with sand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts 300 mm complete all as specified and directed.
125 Butt hinges, extruded brass, with mild steel hinge pin, bright polished and fixed, type C-12 complete all as specified and directed.
150 mm length Brass handles, cast type, polished bright Extruded brass handles, fabricated type polished complete all as specified and directed.
French polishing on surfaces of any description width or girth including cleaning and prepairing the surface including a coat of wood filler on new works with two or more coats complete all as specified and directed.
Preparing new/old wooden surface & applying two coats of synthetic enamel paint over a coat of pink primer over 10 cm width or girth complete all as specified and directed.
18/19 mm thick plywood, grade 1 (with BWR resistance/termite proof) with screws to timber frame work as in cup boards/cabinets etc complete all as specified and directed. Make : Century/kitply or equivalent.
12 mm thick plywood, grade 1 (with BWR resistance/termite proof) with screws to timber frame work as in cup boards/cabinets etc complete all as specified and directed. Make : Century/kitply or equivalent.
0.9 mm thick decorative choice of lamination type-1 of surface finish white stuck with imported adhesive on sides of board complete all as specified and directed. Make : Corby/ Euro
Description all as per ser item No 59 here-in-above but designer type with matic finish 1.5 mm thick complete all as specified and directed. Make : Corby/Euro
5.5 mm thick bevelled edge mirror glass/tintal glass of area not exceeding 0.20 Sqm each as in shelves of size and shape as required at site complete all as specified and directed.
Stainless steel clamps capable of supporting glass shelves of max width 100 mm complete all as specified and directed.
Continuous (piano) hinges, mild steel, bright finish or elecrogalvanised width of flaps when open in 30 mm and fixed complete all as specified and directed.
100 mm long extruded brass handle Polished bright complete all as specified and directed.
Designer brass barrel tower bots of size 150 mm (ISI Marked) including screws and fixed complete all as specified and directed.
Brass mortice lock 30 mm long for 4 leaver cup boards complete all as specified and directed.
Brass hasp and staple size 100 mm powder coated with hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed.
Brass 40 mm dia, cupboard knob fixed with nut, screw and washer of mild steel, brass polished bright bright finished complete all as specified and directed.
Roughening surfaces of concrete floor by picking sweeping cleaning & washingg down with water to remove dust etc including removal of Old/New treatment of any description and applying one coat of neat cement slurry @ 3.00 kg/Sqm complete all as specified and directed by Engr-in-Charge.
Cutting grooves to a depth 75 mm and 100 mm height in columns of water tanh base and after tucking in of roof treatment sealed with PCC 1:2:4 type B-0 (using 12.5 mm graded aggregate) and making curve complete all as specified and directed.
PCC 1:2:4 type B-0 (using 12.5 mm graded aggregate) as in level course on roof surface 25 mm thick etc complete all as specified and directed.
Rendering 10 mm thick in CM 1:3 mixed with integral water proofing compound as per manufacture's instructions as in roof and chajjas and drop facia finished the surface fair and even with out using extra cement complete all as specified and directed. Note : Supply of water proofing compound will be measured and paid separately.
Applying bituminous primer on roof surfaces @ 0.40 ltr/sqm and applying one coat of hot blown bitumen of grade 85/25 @ 1.20 kg/sqm and provide modified polymeric five layered APP (Atactic Polypropylene) Modified Polymeric Membrane with 100 micron high molecular high density polythylene film. Min wt of memebrane will be 3.5 kg/sqm and bonded completely to the surfaces with min end overlap of 15 cms and side lap 75 mm (overlaps to be bounded with thermo fused by flame) and over APP applying one coat of hot blown bitumen 85/25 @ 1.2 kg/sqm blinded with fine sand in dry condition @ 0.5 kg/sqm including two coats of bituminious alluminium paint complete all as specified and directed by Engr-in-Charge.
Supply only integral water proofing compound complete all as specified and directed.
PCC 1:2:4 type B-0 (using 12.50 graded aggregate) for coping, benching and hauching corner of roof and similar work complete all as sepcified and directed.
110 mm PVC (SWR) pipes single socket in any length with rubber ring joints fixed to wall complete all as specified and directed.
110 mm PVC (SWR) bends any radius with access door complete all as specified and directed.
110 mm PVC (SWR) couplers for PVC pipe and similar work complete all as specified and directed.
Aluminum door closer (aluminum extruded section) hydraullically regulated, designation No 3, universal type, suitable for door shutters of 851 mm to 1000 in width and of weight 61 to 80 kg complete all as specified and directed.
Wooden finishes drapery rod powdered coated including double brackets with necessary fitting complete all as specified and directed by Engr-in-Charge.
25 mm thick PCC 1:2:4 type B-1 (using 20 mm graded aggregate) as in level course on floor etc complete all as specified and directed.
15 mm thick screed bed in cement mortar 1:6 for laying floor finishes under floor complete all as specified and directed.
Non skid coloured tiles 7 to 8 mm thick area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding but not backing complete all as specified and directed.
Rendering 10 mm thick on fair faces of brick work or concrete surface in CM 1:4 on vertical surfaces/backing coat complete all as specified and directed.
Glazed ceramic coloured tiles of size 300 x 600 x 7 mm wall tiles set and jointed in neat cement and in white/coloured cement to match with the colour of tile etc. complete all as specified and directed.
Water closet wall mounted pattern pattern colour in repair (as approved by Engineer-in-charge) Make SOMANY Cat Part No (EWC 120305) cistern 120714 Seat cover 121311 Twin flush cistern 120627) UNIEK complete all as specified and directed.
WHB coloured 615 mm x 510 mm with pedestal complete all as specified and directed. Make : CERA CARNIVAL Cat Part No : WHB 1009, PEDESTAL 1108.
CP waste coupling 32 mm dia PTMT (half or full threaded) minimum weight 450 gms complete all as specified and directed.
PVC waste pipe 32 mm bore with cup and washers complete all as specified and directed.
15 mm bore centre hole basin mixer with round spout with 450 mm long copper pipes and brass nuts with out Pop up complete all as specified and directed. Make: Jaquar, Cat Part No : CON 167KNB.
15 mm bore Bib tap complete all as specified and directed. Make : Jaquar, Cat Part No : CON-107KN
15 mm bore angular stop cock with wall flange complete all as specified and directed. Make: Jaquar, Cat Part No : CON- 059KN
PVC connection 15 mm bore 450 mm long Braided Hose with M10X1 Nipple, 15 mm Nut, O-Ring & Rubber washer (Suitable for Basin Mixers) complete all as specified and directed. Make : Jaquar, Cat Part No - ALD-803AB
PVC connection 15 mm bore 450 mm long Braided Hose with two 15 mm Nut & Rubber washer without nipple complete all as specified and directed. Make: Jaquar, Cat Part No - ALD-805B.
Chromium plated toilet paper holder complete all as specified and directed. Make : Jaquar, Cat Part No : ACN 1153N.
Glass shelf with chromium plated guard rails complete all as specified and directed. Make : Jaquar, Cat Part No : ACN-1171N.
600 mm long brass chromium plated towel rail /foldable fancy type complete all as specified and directed. Make : Jaquar, Cat Part No : ACN-1111NM.
Soap dish complete all as specified and directed. Make : Jaquar, Cat Part No : ACN 1131N.
Double Coat hook complete all as specified and directed. Cat Part No : ACN 1161N
Powder coated Aluminium frames for doors, windows, ventilators with one or more rebates and aluminium window and ventilator shuttter frames jointing cleats for fixing and partation wall frame etc complete all as specified and directed thickness of powder coating not less than 50 micron and including 5mm thick tinted glass complete all as specified and directed. Note : Powder coated aluminium coating colour is approved by GE.
Taking down frames with shutters (without taking off shutters from the frame) area not exceeding 4.0 Sqm Each including iron mongery complete all as specified and directed.
Complete removal of existing treatment and applying two coats of oil bound distemper over a coat primers with two coat of wall care putty complete all as specified and directed by Engr-in-Charge.
All as per ser item No 104 but on ceiling complete all as specified and directed.
Supply only for 5.5 mm thick tinted glass pane for glazed fixing for UPVC Windows complete all as specified and directed by Engr-in-Charge.
SWG drain pipe grade 'A' of 150 mm internal dia laid in trenches and jointed in cement mortar (1:1) complete all as specified and directed.
Concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete type D-2 (1:4:8) for 150 mm dia pipe complete all as specified and directed.
Precast reinforced cement concrete (1:2:4) type B-1 (using 20 mm graded stone aggregate) for manhole cover septic tank, drain, culvert covers slabs etc. including necessary form work and set in CM (1:4) complete all as specified and directed. Note:- reinforcement will be measured and paid seperately.
PVC (SWR) junction single (single T) equal or unequal 110 mm dia with access door complete all as specified and directed.
110 mm bore (SWR) vent cowl complete all as specified and directed.
PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) as in surface channel and drains including necessary formwork and extra forming fair finsished drain or channels for inner girth in cement concrete etc complete all as specified and directed.
Bore of pipe 150 mm reinforced concrete pipes, class NP-3 laid and jointed complete with collars as in repair complete all as specified and directed.
PCC type C-1 1:3:6 (using 20 mm graded crushed stone aggregate) as in plinth protection laid in alternate pannels, finished even and smooth without using extra cement complete all as specified and directed.
Plain cement concrete 1:2:4 type B-2 (using 40 mm graded stone aggregate) as in channels and drains, foundation and similar work etc complete all as specified and directed.
300 mm dia reinforced concrete pipes, class NP-3 laid and jointed complete with collars complete all as specified and directed.
Cement concrete type C-2 1:3:6 for concrete bed to 300 mm dia RCC drain pipe including packing under and haunching against the sides of pipes after they are laid & testing complete all as specified and directed.
Cabinet/cupboard in required size at site made out 18mm thick one side decorative lamination sheet consisting of carcass 18 mm thick PVC sheet & provn of shutters made out of 18 mm thick one side decoartive laminated PVC sheet all reqrired brackets 5.5 screws etc. the panels shall be fabricated using adhesive and screws where ever required. All the edbes shall be covered with 2 mm thick edge bonding tape or 90 degree edge bent finish, necessary drawer, openable shelve with frame work complete as per make and specification mention as per drawing and drawer channel, locking system arragement deem to included approved and complete all as specified and directed by Engr-in-Charge. Colour as approved by GE. Make: Rajshree/ Sintex or equivalent
PVC steel catcher of superior quality complete all as specified and directed by Engr-in-Charge.
100 mm long stainless steel alloy handles, decorative type all as approved and complete all as specified and directed by Engr-in-Charge.
Rolled Mild steel sections as in frame work for framed work to cup board, hold fast, fasting bolt fixing of cup board and similar work, water stanging cage, main and cross beams hip and jack rafters, purlines fixed independently and similar work including welding & demolition of wall for fixing of hold fast as per requirement complete all as specified and directed by Engr-in-Charge.
Preparation of new steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified and directed.
PCC 1:2:4 type B-1 (using 20 mm graded aggregate) as in PCC filling in hold fast and similar work complete all as specified and directed.
Reinforced cement concrete 1:2:4 type B-1, (using 20 mm graded crushed stone aggregate) as in slab supported on walls, beams and columns, in floors, roofs and shelves and the like complete all as specified and directed.
Form work to edges of concrete flats, breaks, concrete railing not exceeding 200 mm wide finished rough complete all as specified and directed.
Cutting chases in brick wall, pinning in, making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landing, steps, cills, sunshades, shelves, lintels etc. and cutting chases for concealed water tubing or concealed conduit wiring etc. and making good, cutting not exceeding 10cm girth complete all as specified and directed.
Granite (of any type) tiles 20 mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including griding and polisheing types complete all as specified and directed.
Taking up or down of 15/20mm bore pipes steel tubing and connections complete all as specified and directed.
GI pipe medium grade 15 mm bore in wall and ceiling or laying in floors, including new fittings as required at site complete all as specified and directed.
Sinks with drainage board made of stainless steel 1 mm thick kitchen or loboratory with plugs, washers and wastes, including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm fixed as in repair compplete all as specified and directed
15 mm bore bib taps, long body with wall flange with arreator fency type chromium plated cast copper alloy with crutch or butter fly handle, screwed down, screwed for iron pipe or for brass ferrule fixed in repair complete all as specified and directed.
Screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:4 laying floor finishes complete all as specified and directed.
10 mm thick rendering on fair faces of brick/ concrete surfaces in cement mortar 1:3 and finished even and fair for receiving tiles on vertical surface complete all as specified and directed.
Double charge vitrified ceramic tiles, area of each tile exceeding 0.26 sqm but not exceeding 0.40 Sqm, 10 mm thick (square or rectangular) of superior quality as in floor and walls surfaces set and jointed in neat cement slurry and pointed in white or coloured cement to match the light shade of tiles complete all as specified and directed.
Brick work with sub class B bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed.
New plaster surface of walls and applying two coat of oil bound distempers over one coat of primer and two coat of wall care putty complete all as specified and directed by Engr-in-Charge.
Preparation of new plastered or un-plastered surfaces and walls including cornices, pilasters etc and applying two coats of cement base paint over a coat of primer complete all as specified and directed.
Applying two coat birla wall care putty on old/ New plastered wall surfaces including preparation of surface by brooming down or steel wire brushing, scrapping down vegetation growth, efflorscent salts and trading oil and greasy spot complete all as specified and directed.
Powder coated aluminium frames for Supporting to Cantilever cup board, partitoin, doors, window, ventilators with one or more rebates and aluminium structire made frames jointing Heavy cleats for fixing etc complete all as specified and directed thickness of powder coating not less than 50 micron complete all as specified and directed.
10 mm thick toughened glassand glazing complete including sand blasting/film, glazing clis, rubber acking, powder coated aluminium snap beading, serews complete all as specified and directed.
Complete removal of existing treatment applying two coat of cement base paint over a coat of primer paint on two coat of wall putty (G+3) complete all as specified and directed by Engr-in-Charge.
PVC wall panelling lining consisting of 5 mm thick plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per site requirement complete all as specified and directed by Engr-in-Charge.
5 mm thick PVC sheet fillets of width 35 mm for wall paneling inclusive of fixing to wall to make PVC frame as per site requirement complete all as specified and directed by Engr-in-Charge.
Double charge vitrified ceramic tiles, area of each tile exceeding 0.18 sqm but not exceeding 0.36 Sqm, 10 mm thick (square or rectangular) of superior quality as in floor and walls surfaces set and jointed in neat cement slurry and pointed in white or coloured cement to match the light shade of tiles complete all as specified and directed.
75 mm bore cast iron floor trap with grating including jointing to waste pipe fixed cement concrete type B-1 (1:2:4) complete all as specified and directed.
75 mm bore sand cast iron pipes in any length with or with out ears with cement joints laid in trenches or in floors complete all as specified and directed.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in hard and dense soil complete all as specified and directed.
75 mm thick PCC 1:3:6, type C-1 (using 20 mm graded stone aggregate) as in sub base floor complete all as specified and directed.
Sand cushion 20 to 30 mm thick for laying and fixing interlocking tiles complete all as specified and directed.
Machine pressed precast concrete interlocking paver block (glossy finish) any shape and size (sample approved by GE) confirming to IS 15658-2006 of 60 mm thickness M-35 grade with grey cement and pigment complete all as specified and directed by Engr-in-Charge.
Concrete bed to drain pipes 300 mm dia type 1:3:6 C-2 including paking under and haunching against the sides of pipes after they are laid and tested complete all as specified and directed.
Machine pressed (factory made) precast plain cement concrete 1:2:4 type B-1 (20mm graded crushed stone aggregate), kerb stone & the like of size 300mm x 300mm x 100mm thick or of size as approved by GE, with plain fair faces including chamfers, weathering etc, embedding in position/laid in trenches on edges of roads, including excavation in any type of soil, setting in cement mortar (1:4) returning filling and removal of surplus soil/ debris to a distance not exceeding 50m from the starting point complete all as specified and directed.
Point wiring for one light/fan/bell point controlled by one switch using 1.5 Sqmm FRLS copper conductor cables (multistranded) PVC insulated and unseathed in and including PVC concealed conduit (thickness not less than 1.5 mm and 20 mm dia), medium grade with Modular metal flush boxes thickness (1.25 mm) & PVC back plate for mounting modular type in adequate module of switches, sockets & regulators etc with front plate modular type including supplying and laying PVC insulated unsheathed 1100 volts copper conductor cable 1.5 Sqmm as earth wire stranded and conected to earth dolly complete all as specified and directed. Make: Havells/ Finolex/Polycab.
All as per ser item No 154 but for 3 pin 6 Amps socket outlet independent including copper PVC insulated PVC unsheathed 1.5 sqmm earth wire and connected to earth dolly complete all as specified and directed.
All as per ser item No 154 but for 3 pin 6 Amps socket outlet on the same board including copper PVC insulated PVC unsheathed 1.5 sqmm earth wire and connected to earth dolly complete all as specified and directed.
All as per ser item No 154 but for 3 Pin 16 Amps socket outlet independent with cable 2.5 Sq mm including copper PVC insulated PVC unsheathed 1.5 sqmm earth wire standard and connected to earth dolly complete all as specified and directed.
All as per ser item No 154 here-in-before but for one 3 Pin 15 Amps socket outlet independent with cable 4.0 Sqmm including copper PVC insulated PVC unsheathed 2.5 sq mm earth wire standard and connected to earth dolly complete all as specified and directed.
Switch Piano flush type 6 Amps single pole one way (Modular Type) with outer strip complete all as specified and directed. Make: Havells (Crabtree)/Legrand/Philips/Polycab.
Switch Piano flush type 16 Amps single pole one way (Modular Type) with outer strip complete all as specified and directed. Make: Havells (Crabtree)/Legrand/Philips/Polycab.
Socket 2-in-1, 3 Pin 6 Amps (Modular Type) with outer strip complete all as specified and directed. Make: Havells (Crabtree)/Legrand/ Philips/Polycab.
Socket 2-in-1, 3 Pin 6 & 16 Amps (Modular Type) with outer strip complete all as specified and directed. Make: Havells (Crabtree)/ Legrand/Philips/Polycab.
Electronic step type fan regulator 120 watt 230 volts 50 C/S deluxe modular type complete all as spcified and directed. Make: Havells (Crabtree)/Legrand/ Philips/ Polycab.
Ceiling rose surface bakelite 3 terminals complete all as specified and directed. Make: Havells (Crabtree)/Legrand/Philips/Polycab.
Supply & Hanging Ceiling fan 1200 mm sweep complete set without regulator including connecting to ceiling rose with twin twisted flexible cooper cable and provisioning of suitable fan hook/down rod including all accessories as per site requirement complete all as specified and directed. Make :- Havells Model: ES-50 or equivalent to Bajaj/Philips /Crompton.
Single pole and neutral enclosure surface mounted 240 volts with 2 pin and earth plug and socket with one single pole MCB 20 Amps with indicator of make wipro/equivallent in Havells/Bajaj complete all as specified and directed.
New E-Lite LED Curve, high lumen batten with efficacy of 100 lumens in 20 W Make-Havells Cat Part No LHEXBXPNIN1W020 or equivalent to Philips/Wipro/Seimens/Polycab complete all as specified and directed by Engr-in-Charge.
Replacement 2 X 40W Mini GLS E14 wall mounting, chrome finish fixture with frosted glass suitable for 40W mini GLS Lamp with LED bulb complete all as specified and directed. Make : Havells Cat Part No - LHFOFCC2TZ1C040 or equivalent to Philips/ Wipro/Seimens/Polycab.
Replacement Bed Side Lamp, 7W with LED Bulb complete all as specified and directed. Make : Havells or equivalent to Philips/Wipro/ Seimens/Polycab.
Replacement of LED bulk head luminaire, 10 W (ENDURA RUGBY) Cat Part No LHEOAOP7UZ6W010 Make : Havells 230 Volts wall/surface mounted complete with with LED lamp 10 watt, with all accessories, pre-wired, including providing flexible copper wire, twin core cable complete all as specified and directed by Engr-in-Charge. Make: Philips/ Wipro/Seimens/Polycab.
Sheet metal enclosures for DBs when MCBs to be used double door DB SPN 12 way 240 volts with 200 amps rated bus bar and neutral link in cluding chases wall for dixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed. Make : Havells/ Schneider/Legrand/Siemens.
Replacement sheet metal enclosures for DBs when MCBs to be used double door DB VTPN 100A 4way IP43 Protection complete all as specified and directed. Make: C&S, Cat Part No - CSDBMCCB100DD04IP43 with 100A MCCB 10kA Make: C&S, Cat Part No - CS2A4 or equivalent to Make : Havells/Schneider/ Seimens.
Replacement MCB Single Pole, 230 Volt, Raiting 6 to 32 Amps Product Code: CSMBS1B32 complete all as specified and directed. Make : C&S or equivalent to Havells/ Schneider/Legrand/Siemens
Replacement MCB Single Pole and Neutral , 230 Volt, Raiting 63 Amps, Product Code: CSMBS1B63N complete all as specified and directed. Make : C&S or equivalent to Havells/ Schneider/Legrand/Siemens
Sub main wiring with two single core PVC insulated with copper conductor cable stranded of size 6.0 Sqmm in PVC concealed conduit 25 mm dia including PVC insulated copper conductor cable 4 Sqmm as earth lead complete all as specified and directed. Including taking down old sub main wire.
Sub main wiring with two single core PVC insulated with copper conductor cable stranded of size 10 Sqmm in PVC concealed conduit 25 mm dia including PVC insulated copper conductor cable 6 Sqmm as earth lead complete all as specified and directed. Including taking down old sub main wire. Make: Havells/Finolex/Polycab.
Sub main wiring with two single core PVC insulated with copper conductor cable stranded of size 4.0 Sqmm in PVC concealed conduit 25 mm dia including PVC insulated copper conductor cable 2.5 Sqmm as earth lead complete all as specified and directed. Including taking down old sub main wire. Make: Havells/Finolex/Polycab.
Earthing complete with galvanised steel earth plate electode 600mm x 600mm x 6.00mm thick burried directly in ground (earth pit not less than 2.25 meter deep below normal ground level connected to and including galvanised steel earth lead wire 4 mm dia by means of bolts, nuts, chock, nuts and washers of galvanised iron or steel including PCC Pit in 1:2:4 type B-1 angle iron frame with RCC cover and handle, excavation and earth work in any type of soil medium grade GI watering pipe 20 mm bore with funnel and wire mash and light grade GI protection pipe 15 mm bore upto main board complete all as shown in electrical plate No 3 of MES Sch 2009 (Part I) connected to main control board as specified and testing completion.
Supply and install AC in hi wall split unit air conditioner reversible type indoor and outdoor unit complete with cordless remote control unit and wi airioniser and plasma filter for better indoor air quality of capacity 1.5 ton with standard assessories including MS frame work for installation of outer with wall side complete all as specified and directed. Make : Voltas or equivalent to CARRIER / DAIKEN and making required hole in wall for passing of cooling pipes/cable and repair work tone damaged portion of wall in CM 1:4.
Supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and designed for input voltage 110V to 250V with accuaracy of +2.5% and capacity 5 KVA. Make : AE/Blue Bird/Voltas.
Supply and fix copper tubing including brazing and lead testing alongwith insulation of any size as required for fixing of split AC of capacity 2.0/1.5 ton complete all as specified and directed by Engr-in-Charge. Make : GODREJ/ATLAS/DEVIDYAL size 5/8 and 1/4.
Supply and fix sub main wiring with two single core PVC insulated FRLS unsheathed copper conductor cable 1100 volts grade 6 sqmm size in PVC conduit heavy duty ISI marked with 6 sqmm PVC insulated FRLS copper conductor cable as earth lead to connecting to earth dolly complete all as specified and directed by Engr-in-Charge.
Supply and fix wiring for connection between outer and inner unit of split AC with four singlecore PVC insulated FRLS unsheathed copper conductor cable 1100 volts grade 2.5 sqmm size in PVC conduit heavy duty ISI marked with 2.5 sqmm PVC insulated FRLS copper conductor cable as earth lead/single to connecting to earth dolly complete all as specified and directed by Engr-in-Charge.
Replacement of New E-Lite LED Curve, high lumen batten with efficacy of 100 lumens in 10 W complete all as specified and directed by Engr-in-Charge. Make - Havells Cat Part No LHEXBXPNIN1W010 or equivalent to Asco/ Philips.
Sheet metal enclosure MCB distribution board single pole & neutral 240 volts 8 way with IP-43 IK-09 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed. Note -MCBs will be measured separately. Make: Asco/Havells/Legrand
Taking down carefully, copper/aluminum point wiring (light, fan, socket or power/LED Light fittings) complete fitting such as switch, sockets, ceiling rose, pendants socket any type, rectangular board terminal boxes etc and making good disturbed surfaces of walls floors and ceiling complete all as specified and directed. Keeping the LED lights in safe custody.
M&L for XLPE insulated, armoured, aluminium conductor cable, 1100 volts grade, heavy duty, cross sectional area 35 Sq mm, 3.5 core, laid in trenches/ducts/through pipe complete all as specified and directed. Make:- Havells/Gloster/Polycab.
All as per Srl item No.187, here in before but cross sectional area 10 Sqmm, 2 core.Make:- Havells/Gloster/Polycab.
M&L for providing earthing with GI earth plate elctrode 600 x 600x 6.3mm buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the earth plate not less than 1.5m below ground level connected to GI strip 32 x 6mm thick for earthing lead fixed by means of nuts, bolt, washers etc connected to earth test point complete all as specified in electrical plate No 3 of SSR 1996 part 1, including necessary excavation and earth work in any strata of soil, comman salt, charcoal dus, 40 mm dia light grade GI pipe for protection to earh lead, GI water pipe 20mm dia with funnel & wire mesh, PCC pit with CI cover and frame etc all as specifed and directed by Engineer-in-Charge. Note :- All the joints shall be made with welding to get proper conductivity.
Removing of excavated materials to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as specified and direced.
Supply and fix DWC (Double wall corrogated) pipe with out side diameter 50mm and inside dia 38mm to hold 3.5 core 35 sqmm LT cable. Necessary couplers and spacers and any additional attachments required shall be inclusive of rate quoted by the contractor. Make :- Rex poly extrusion/Tirupati.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundation etc for laying cables, for shafts, wells, cesspits, manholes, pier holes, for cables/ pipes, etc.n.exc 10 Sqm on plan and n. exc 1.5m in depth and getting out in any type of soil, complete all as specified and as directed.
khajuria builders
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .