Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) SIRSA
GE (AF) SIRSA
REPAIR/ MAINT/ IMPROVEMENT OF LT DISTRIBUTION SYSTEM ALONG WITH ALLIED WORKS AT AF STN SIRSA
2021_MES_464083_1
GE/SRA/T-35 OF 2021-2022
Open Tender
Miscellaneous Works
Item Rate
273 days
GE (AF) SIRSA
As per Tender documents/NIT
3 documents required · 3 mandatory
₹500
GE (AF) SIRSA
₹40,000
Yes
4 Sept 2021
31 Jul 2021
1 Sept 2021
31 Jul 2021
30 Aug 2021
16 Aug 2021
31 Jul 2021 - 13 Aug 2021
60 days
Amount
Disconnecting & Taking down/out Serviceable/ unserviceable LT Cable of any size and any description and from Panels, Bus Bars, Load Line, Distribution Box,Trenches, Floors, Walls, GI Pipes etc. including Serviceable Pipes, Bricks, etc. for repair/ replacement of lugs, checking of fault in the cable, complete all as specified and as directed. NOTE : (i). Necessary Earth Work will be Measured and Paid under appropriate Items. (ii). Old cable will be property of department and depositing to MES store yard.
Excavation in trenches not exc. 1.50 Metre wide and not exc. 1.50 Metre in depth for laying of Cable/Pole/Stays, etc., getting out including forming bottom surface to required level and gradient in Soft/ loose Soil and getting out, complete all as specified and as directed.
Demolition Cement Concrete (un-reinforced) of in Ground & Pavings. not exc. 150mm thickness (below or above Ground Level) and removing debris, etc. to Outside MD/AF Land, complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 Cm in Soft/ Loose Soil, complete all as specified and as directed.
Removing excavated materials not exc. 50.00 metre and depositing where directed at a level not exc. 1.50 metre above the starting point, complete all as specified and as directed.
Making Hole under Road/ Hardstanding including cutting, etc. with manual anger or bookie not exc. 100mm dia, complete all as specified and as directed.
M&L Sand Cushioning (dry) in trenches/Ducts for protection of UG Cables (below, above and around the UG Cable laid) of 23 Cm Spread thickness (15 Cm in depth before laying the Cable and 8 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. NOTE : (i). For the purpose of Payment, punned thickness of Sand Cushioning only will be Measured.
Supply & laying in Trenches Sub-class ‘B’ Bricks, kiln burnt, for Cable Protection, complete all as specified and as directed.
Laying in Trenches Bricks (Serviceable Bricks obtained from Item No. 01.00 above), for Cable Protection, complete all as specified and as directed.
S & F for replacement of XLPE insulated, armoured heavy duty Electric Cable with Aluminium Conductor, 1100 Volt grade, Cross sectional area 400 Sqmm 3½ Core with suitable size Aluminium Thimbles including jointing and testing, complete all as specified and as directed.
All as per item No. 10 above but of size 300 Sqmm 3.5 Core.
All as per item No. 10 above but of size 185 Sqmm 3.5 Core.
All as per item No. 10 above but of size 120 Sqmm 3.5 Core.
All as per item No. 10 above but of size 95 Sqmm 3.5 Core.
All as per item No. 10 above but of size 70 Sqmm 3.5 Core.
All as per item No. 10 above but of size 50 Sqmm 3.5 Core.
All as per item No. 10 above but of size 35 Sqmm 3.5 Core.
All as per item No. 10 above but of size 25 Sqmm 4 Core.
M&L for Laying only XLPE Under Ground Cable of any description (Serviceable Portion of old Cable obtained from Item No. 01.00 above) 1100 Volt grade, cross sectional area 150 Sqmm to 400 Sqmm, 3½/4 Core, jointing and Testing, complete all as specified and as directed.
All as per item No. 19 above but of size 35 Sqmm to 120 Sqmm, 3½/4 Core.
All as per item No. 19 above but of size 06 Sqmm to 25 Sqmm, 2/3½/4 Core.
S & F in repairs Heat Shrinkable LT 1100 Volt Straight Through Joint suitable for XLPE Aluminium Conductor Cable, cross sectional area 25 Sqmm to 35 Sqmm, 3½/4 Core, complete all as specified and directed.
All as per item No. 22 above but of size 50 Sqmm 3.5 Core.
All as per item No. 22 above but of size 70 Sqmm 3.5 Core.
All as per item No. 22 above but of size 95 Sqmm 3.5 Core.
All as per item No. 22 above but of size 120 Sqmm to 150 Sqmm 3.5 Core.
All as per item No. 22 above but of size 185 Sqmm 3.5 Core.
All as per item No. 22 above but of size 240 Sqmm 3.5 Core.
All as per item No. 22 above but of size 300 Sqmm 3.5 Core.
All as per item No. 22 above but of size 400 Sqmm 3.5 Core.
S&F in replacement of Heat Shrinkable LT 1100 Volt Outdoor/ Indoor termination kit with lugs suitable for XLPE Aluminium Conductor Cable, cross sectional area 25 Sqmm to 35 Sqmm, 3½/4 Core, complete all as specified and directed.
All as per item No. 31 above but of size 50 Sqmm 3.5 Core.
All as per item No. 31 above but of size 70 Sqmm 3.5 Core.
All as per item No. 31 above but of size 95 Sqmm 3.5 Core.
All as per item No. 31 above but of size 120 Sqmm 3.5 Core.
All as per item No. 31 above but of size 150 Sqmm 3.5 Core.
All as per item No. 31 above but of size 185 Sqmm 3.5 Core.
All as per item No. 31 above but of size 240 Sqmm 3.5 Core.
All as per item No. 31 above but of size 300 Sqmm 3.5 Core.
All as per item No. 31 above but of size 400 Sqmm 3.5 Core.
S&F in replacement of Aluminium Cable Lugs suitable for XLPE Aluminium Conductor Cable, cross sectional area 25 Sqmm 4 Core, complete all as specified and directed.
All as per item No. 41 above but of size 35 Sqmm 3.5 Core.
All as per item No. 41 above but of size 50 Sqmm 3.5 Core.
All as per item No. 41 above but of size 70 Sqmm 3.5 Core.
All as per item No. 41 above but of size 95 Sqmm 3.5 Core.
All as per item No. 41 above but of size 120 Sqmm 3.5 Core.
All as per item No. 41 above but of size 150 Sqmm 3.5 Core.
All as per item No. 41 above but of size 185 Sqmm 3.5 Core.
All as per item No. 41 above but of size 240 Sqmm 3.5 Core.
All as per item No. 41 above but of size 300 Sqmm 3.5 Core.
All as per item No. 41 above but of size 400 Sqmm 3.5 Core.
S&F in replacement of Heat Shrinkable Cable Sleeves suitable for XLPE Aluminium Conductor Cable, cross sectional area 25 Sqmm to 50 Sqmm, 3½ Core, complete all as specified and directed.
All as per item No. 52 above but of size 70 Sqmm to 120 Sqmm 3.5 Core.
All as per item No. 53 above but of size 150 Sqmm to 185 Sqmm 3.5 Core.
All as per item No. 54 above but of size 240 Sqmm to 300 Sqmm 3.5 Core.
All as per item No. 55 above but of size 400 Sqmm to 500 Sqmm 3.5 Core.
S&F in replacement of Aluminium Bus Bar with heat shrinkable sleeves of any size and any description with insulators, complete all as specified and directed.
S&F in replacement of Galvanised Steel tubing Pipe 50mm bore (dia), light grade with Bend, laid in trenches or under Roads/ Walls/ Flooring/ Culverts and/or fixing to Electric Poles including repair work required as per existing with suitable size Mild Steel Flat Iron Clamps, Bolts, Nuts, Washers, etc., complete all as specified and as directed.
All as per item No. 18 above but of size 80mm.
S&F in repairs of Feeder Pillar Box of size 60x60x45 Cm, made out of CRCA Sheet 3.0mm thick, Outdoor, Pedestal type, Weather Proof, Epoxy based Powder Coated Paint, Self-Closing Door having with Locking Arrangement, mounted on brick work Platform of size 100x100x60 Cm with plastering, comprising with 4 No. Aluminium Bus-bar of current rating 600 Amp with and including 1 no. MCCB 320 Amp 25 kA, 4 Pole, complete all as specified and as directed.
All as per item No. 60 above but of bus bar current rating 400 Amp with 1 no. MCCB 200 Amp 25 kA, 4 Pole.
All as per item No. 60 above but of bus bar current rating 200 Amp with 1 no. MCCB 100 Amp 25 kA, 4 Pole.
M&L for replacement of Earthing with Galvanised Earth Plate Electrode 600x600x6.3mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc. 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded crushed stone aggregate) with Cast iron cover 10mm thick hinged, Cast Iron Frame, MS Rod 6mm, Funnel, GI Pipe 20mm medium grade all as shown in Electrical Plate No. 3 of MES Schedule Part-I, with GI Strip 25 x 4mm protected by GI Pipe 40mm dia upto 7.5 Meter including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and and Testing on Completion ,including takingout old earth plate and connected accessories, complete all as per specified and as directed.
S&F in replacement of SMC Chequered Plate 2.5mm thick for Duct, square cut or notched, Durable and resistant to decay, Maintenance-free, High dielectric strength, High life expectancy, Anti-corrosive complete all as specified and as directed.
S&F in replacement of 'Shock Treatment Chart' duly printed with Hindi & English, fitted with Wooden Card Board of size 100x60 Cm with hanging arrangement for Installations complete all as specified and as directed.
S&F in replacement of 'Prevention from Fire Chart' duly printed with Hindi & English, fitted with Wooden Card Board of size 100x60 Cm with hanging arrangement for Installations complete all as specified and as directed.
Taking out old serviceable Pre-stressed Concrete/Steel tubular pole 9.0/ 11.0 metre long and shifting to other location in the permises of Air Force Station including cast iron base plate, finial taper plug, cap, mild steel bolts, nuts, screws, etc. complete all as specified and as directed. NOTE: Earthwork, Cement Concrete, etc. will be Measured and Paid separately under approprite Items.
M&L for cement concrete 1:4:8 (40mm graded curushed stone aggregate) as lean concrete in foundation of poles, etc. including formwork (as/ if required) complete all as specified and as directed.
M&L for cement concrete 1:3:6 (40mm graded stone crushed aggregate) as in foundation of poles, stays, etc. including formwork (as/ if required) complete all as specified and as directed.
S&F in replacement of Glow Sign Board made of Polycarbonated sheet (PVC) of size 120x75 Cm with writting Installation Name with self- reflective adhesive tape of size as directed including frame Work complete with fitting arrangment with internally pre-wired with copper conductor cable 1.5 Sqmm including LED Lamp 09 Watt - 02 No. with copper conducting cable 1.5 Sqmm 3 Core upto 7.5 m , complete all as specified and as directed by engineer-in-charge.
Preparing of existing surfaces of Wall/ Pole/ VCB/ RMU/ Transformer, etc and preparing the surface smooth applying Two Coats of Synthetic Enamel Paint over a coat of Red Oxide Zinc Chrome Primer for Writing/Painting of single line diagram of Instructions, distribution system and other complete all as specified and as directed. NOTE : (i). Instructions and Colour of Paint for Writing Letters will be decided by the Engineer-in-Charge.
M&L for Cement Concrete 1:2:4 typr B-1(20mm graded crushed stone aggregate) 1:2:4 around the LT/HT Pole/Bus Bar/LT Panel/Path, 15 Cm thick, complete all as specified and as directed.
S & F in replacement of PVC Insulated Multi Stranded Aluminium Conductor Cable, 1100 Volt grade, heavy duty of size 16 Sqmm 2 Core complete all as specified and as directed. NOTE : (i). Old cable will be property of department and depositing to MES store yard.
AMBIKA ENTERPRISES
shiv shanker enterprises
VIVEK CONSTRUCTION CO
BS BUILDERS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .