| 1 | L1₹45.3 LAccepted-AOC GALI NO 5 6 H NO 6 275 JHARODA MAARA EXTN PART III BURARI NEW DELHI 110084 | NEW DELHI | CENTRAL DELHI | DELHI | 110084 | L1 | Accepted-AOC L1 | |
| 2 | L2₹52.7 L+₹7.4 L (16.3%)Rejected-Finance FLAT NO 330 PKT 1 SECTOR 1 DWARKA NEW DELHI 110075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | L2 | Rejected-Finance Other than lowest |
Tender Value
₹48.4 L
EMD Value
₹96,800
Closing Date
30 Nov 2021, 6:00 pmClosed
GE NORTH DELHI CANTT-10
GE NORTH DELHI CANTT-10
PROVN OF WAITING SHED FOR TROOPS AT COD AND ADDN AND ALTRN TO KITCHEN CUPBOARD AND REPAIR TO FLOOR OF HALL IN BLDG NO P 1 AT KIRBY PLACE AND PROVN OF ELECTRIC ITEMS FOR INSTALLATION OF 15 KVA GEN SET IN 339 I SUP PL ASC TMARPUR AND PROVN OF 20x ELE
2021_MES_486230_1
GE/NORTH-42/2021-22
Open Tender
Civil Works
Item Rate
180 days
GE NORTH DELHI CANTT-10
As per NIT
8 documents required · 8 mandatory
₹500
Yes
GE NORTH DELHI CANTT-10
₹96,800
Yes
14 Dec 2021
3 Nov 2021
2 Dec 2021
3 Nov 2021
30 Nov 2021
17 Nov 2021
Amount
B/R Portion :- Excavation in post holes (or similar holes) each n.exc 0.5 cum and getting out in soft/loose soil complete all as spd.
M/L PCC 1:4:8, type D2 using 40mm grade stone agg as in foundation fillingand mass concrete all as specified and directed.
M/L PCC 1:3:6, type C2 using 40mm grade stone agg as in foundation/fancing post fixing all as specified and directed.
S & F for providing & fixing of roof with multilayer standing seam polycarbonate panels system of 16mm thickness (minimum) including all standard fixing accessories on top of the supporting structure (Paid extra in another item) complete & as per the direction of the engineer in charge. The panel should work on angular daylight concept with translucent and opaque combination of louver inside, for better thermal insulations and diffusion of lightespecially with white and clear combination designed for tropical regions & shdind through the day for better ambient temprature below the roof. Panels shall have minimum seven layers with all fixing accessories to ensure best performance for wind uplift , vibration, oil canning and visual appearance. The entire panel system shall be with a width from min. 1200mm. Bigger width and minimal junctions should be preferred for better performance. Panels shall be manufactured with vertical offset standing seam at both side of the panel. Panels have to be fixed on Purlin with snap on connector with grip ock double tooth locking mechanism and will be secured on MS structure/purlins (will be paid seprately) with HDSS Fastner and double tooth polycarbonate connector for best stability and having a pull out load of min. 7000N (7KN) tested as per ISO 6892:1998 and IS 1608:2005. Penals cell structure be in truss bridge design or commonly called caed X structure for better strength and stability. Penals must satisfy dart drop impact test as per IS 14443-97 shall show no sign of breakage on Polycabonate Penal which have been exposed to UV for a min of 500 Hours as per ASTM G 155. Panels shall not have yellowness Index as per ASTM D 1925 of 15 units when tested on a sample exposed to UV for 500 Hours as per ASTM G 55. U value shall not be more than 2.0 W/m2K as per EN ISO 10077-2:2018. Panel shall be with additional End cap/Aluminium U/F profile/Glazing bar (all mill finish) for ends as required. Trained and factory authorised labour with supervision to complete the entire panel instalation as per drawing and direction of the engineer in charge. COlor : A Combination of Clear/White or any colour in a single panel and as per approved sample.
Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc, including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement.
M&L rendering 15mm thick in cement mortar (1:4)on brickwork/concrete surfaces complete all as specified and directed.
M&L preparation of newly plastered surface of walls and applying two coats of cement base paint complete all as specified and directed.
M & L for 100mm thick PCC 1:4:8 type D2 all as specified and directed.
M & L for 600mm x600mmx12mm thick glazed exterior tiles fix with neat cement slury over 20mm thick screeding in cement mortar 1:4 and pointing with epoxy mortar all as specified and directed.
M&L for 18 mm thick one side decorative lamination and other side balancing white sheet consisting of carcass 18 mm thick PVC sheet fixed with approved adhesive and self tapping screws all as specified and directed.
M&L for 6 mm thick one side decorative lamination and other side balancing white sheet consisting of carcass fixed with approved adhesive and self tapping screws all as specified and directed.
S&F for 20 mm wide & 1mm thick PVC EDGE Bening pasted to Edges of PVC furniture with suitable adhesive complete all as specified and directed.
S&F soft close Telescopic drawer channel for fixing of baskets model No RHS - 4503-20 . Make Peacock, Revera, Glen as specified and directed.
S&F 75 mm SS Butt hinges, with mild steel hinge pin, bright and fixed, type B-11 complete all as specified and directed.
S&F continuous (paino) hinges (width 30 mm ) mild steel, bright finish or electrogalvanised.
S&F 100 mm size extruded brass handles fabricated type polished complete all as specified.
S&F mild steel magnatic catches and striking plate of 50 mm size for kitchen cup board or wardrobe fixed with screw including letting in and fixed complete all as specified and directed.
S&F perforated cutlary (475 x 485x 350 mm) stainless steel of grade 304 complete all specified and directed.makePeacock, Revera, Glen
S&F three tier trolley bottle pull out bottle size 485 x 530 x 150 mm of stainless steel of grade 304 complete all specified and directed. Make - Peacock, Revera & Gian
S&F plate basket (475x535x200 ) mm of stainless steel of grade 304 complete all specified and directed. Make - Peacock, Revera & Gian
S&F MP basket (475x485x350) mm of stainless steel of grade 304 complete all specified and directed. Make - Peacock, Revera & Gian
S&F C&S Basket (475x485x350) mm Stainless steel of grade 304 complete all specified and directed. Make - Peacock, Revera & Gian
S&F VEG Basket (475x485x350) mm Stainless steel of grade 304 complete all specified and directed. Make - Peacock, Revera & Gian
S&F Thal Basket (475x485x350) mm Stainless steel of grade 304 complete all specified and directed. Make - Peacock, Revera & Gian
S&F Grain Basket (475x485x350) mm Stainless steel of grade 304 complete all specified and directed. Make - Peacock, Revera & Gian
Roughening old concrete floor by picking, seweeping clean and washing down with water to remove dust etc and brushing near cement slurry with 3 Kgs of cement per sqm
Taking down cement plaster on bnrick/stone wall etc including raking out joints, hacking for key, scrubbing down with water etc.
M&L Screed bed or bedding layer of mortar 15 mm thick for laying floor tiles in CM 1:4.
M&L for 15 mm thick rendering on fair faces of brick works in cement mortar 1:4 finished rough for receiving tiles as in dado.
S&F Vitrified ceramic tiles 10 mm thick of Dark shade (Square/rectangular) polished area of each tiles exceeding 0.36 Sqm but not exc 0.42 Sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified by GE.
Refixing shutter of any description in the same opening after easing area exc 1 Sqm and not exc 2 Sqm each
M&L for machine cut polished granite stone slab 18-20mm thick fixed over screed bed 15 mm thick CM 1:4 including cutting. Jointing pointing with white / coloured cement to match existing complete all as specified and directed by GE.
Moulding of Granite.marble stone full round complete all as specified.
EM Porttion: - Supply and fixing of Water heater storage type, electric, capacity 25 Ltrs BEE 5 star rated, wattage 2KW, ABS plastic body, temparature indicating dial, enamel coated heating element, glass line coated inner tank, magnesium anode type, adjustable thermostat, inlet (cold water) and out let(Hot water) pipes incl fixing with fasteners at wall and making good, finishing to disturbed surface to match the existing surface incl connection complete. (Make-Bajaj calenta/ Havells/ Racold)
M&L for XLPE insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 vollts grade, incl making connection using glands/ thimbles complete all specified and directed for cross sectional area of following sizes :-
16 Sqmm 4 core
10 sqmm 2 core
Excavation in trenches not exceeding 1.5 mtr depth width and not exceeding 1.5m depth for laying under ground cable in loose/soft soil all as specified and directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm all as specified and directed
Removal of surplus soil obtained from excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point all as specified and directed
M&L for sand cushioning for protection of PVC cable with screen wash river sand and punning to proper required cover all as specified and directed
M&L for bricks of sub class ‘B’ bricks, for cable protection in trenches laid dry and flat all as specified and directed.
Supply and fix ON LOAD change over switch 63 amps 4 pole, 415 V, with sheet metal enclosure including connection completed all as specified & directed
S&F of GI tubing light grade of 40mm bore dia for cable protection on pole/wall/floor or in trenches and drain etc complete with necessary clamp, nut, bolts and washers and socket and making good the disturbed surface of wall, floor or roof etc all as specified and directed
Supply, installation and connecting to electrical system, LT distribution switch board panel cubical type for out door use, double door, with rigid hinges, door handles locking arrangement back side openable, compartmentalized design, mounted on suitable PCC blocks including PCC & earth work, fabricated out of CRCA sheet 3.00mm thick, suitably spaced, totally enclosed in chamber for reception of 3 phase, 440 V, 50 Hz, AC supply, including all connection with aluminum lugs, internal wiring with suitable size (minimum 1.5 sqmm) of PVC copper conductor wire with lugs, panel shall be effectively PVC gasketed and sealed, glands to be provided at cable entries, powder coated painted and sign writing for in/out going connections complete and comprising of following as under :-
(a) 4 Nos bus bars of high conductivity aluminium alloy, 3 Nos for phase (R,Y,B) rating 200 amp rating and 1 No for neutral rating 100 amp, mounted on DMC support with heat shrink sleeve - 01 set.
(b) MCCB 4 pole, 100 amp, 415 volts, 25 KA - 01 No ( Incoming)
(c) MCCB 4 pole 40 amp, 415 volts, 25 KA - 04 Nos. (outgoing)
(d) Voltmeter (0-500V) three phase, digital type -01 No
(e) Ammeter (0-200Amps) three phase, digital type with CT's - 01 No
(f) Indication lamp (R,Y,B), LED type - one set of three
M&L for two single core (submain) PVC insulated cable with 6 sqmm nominal cross sectional area stranded copper conductor and one single core green PVC insulated 6 sqmm stranded copper conductor earth continuity cable drawn through non metallic rigid PVC conduit 20 mm dia concealed in wall including all conduit and fixing accessories including cutting chases & making disturbed surfaces complete all as specified & directed
M&L For Sub main wiring with 4 sqmm (Nominal area) with two runs of single core cable PVC insulated FRLS multistrand unsheathed copper conductor cable including 1100 V grade, drawn through pvc conduit including 4 sqmm (nominal area) single core PVC insulated multistrand unsheathed copper conductor as earth wire and duly connected to all common earth point all as specified and directed.
Supply and fixing of Industrial type SPN enclousre with a two pin and earth plug and socket complete with and including MCB SP AC 240 Volts of 20 Amps C series 10KA breaking capacity and flush to wall including all cuttings & chases etc in wall and making good to the disturbed surfaces to match the existing complete.
S&F MCB SP 240 Volts AC 6 - 40 Amps of breaking capacity 10 KA C curve in existing DBs complete all as specified.
Supply and laying galvanised steel water tubing 15mm bore medium grade ISI marked, clamping with necessary hooks on above wall/tiles surfaces complete screwed socketed joints and making good, finishing to disturbed surface to match the existing surface incl connection with all tube fittings complete all as specified and dirtected.
M&L for stop valves/angular stop cock, screwed down, high pressure fancy type, chromium plated 15mm bore for iron pipe with all fittings complete all as specified and directed.
M&L for earthing with Galvanised Steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanised Iron strip of size 32 X 6 mm as earthing lead (upto the body of the equipment) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 40mm dia GI pipe connected to main switch board or main control board and GI pipe medium grade 20mm bore for watering and including funnel , wire mesh, RCC pit cover and PCC chamber pit with PCC (1:3:6) type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 5 of SSR 1991(Part-I) complete all as specified and directed
Sch of Credit- Total contract sum shall be calculated after deduction of Sch of Credit amount Credit amount - Nil
The new hut furnitures
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .