Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹12.0 LAccepted-AOC H NO 2049 HANUMAN COLONY NEAR TCP 3 HISAR CANTT PIN 125006 HARYANA | HISAR | HARYANA | 125006 | 1 | Accepted-AOC L1 | |
| 2 | 2₹13.8 L+₹1.2 L (9.79%)Rejected-AOC NOT FOUND | 2 | Rejected-AOC L2 | |
| 3 | 3₹14.0 L+₹1.4 L (11.3%)Rejected-AOC NAGAR PANCHAYAT PATHARDEVA DEORIA | 3 | Rejected-AOC L3 | |
| 4 | 4₹15.4 L+₹2.8 L (22.5%)Rejected-AOC | 4 | Rejected-AOC L4 |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
19 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) SIRSA
GE (AF) SIRSA
REPAIRS AND CLEANING OF SEWAGE LINES IN DOMESTIC AREA AT AF STN SIRSA
2022_MES_530180_1
GE/SRA/T-11 OF 2022-2023
Open Tender
Miscellaneous Works
Item Rate
333 days
GE (AF) SIRSA
As per NIT and Tender documents
3 documents required · 3 mandatory
₹500
GE (AF) SIRSA
₹40,000
Yes
14 Sept 2022
11 Jun 2022
21 Jul 2022
11 Jun 2022
19 Jul 2022
25 Jun 2022
11 Jun 2022 - 20 Jun 2022
60 days
Amount
M&L Removing Complaint of Blockage (viz Blockage in Bath, Kitchen, WC & Drainage in Traps/Line from Trap to 1st Manhole, Blockage in Sewage Line from 1st Manhole to Septic Tank, Cleaning of Manhole) by deploying Trades Men as per Stipulated Time Frame from 9.00 AM to 5.00 PM and maintaining proper Records of COMPLETED and PENDING Complaints including Updating Status of Complaints through SMS/Manually for DOMESTIC AREA at AF STATION SIRSA, complete all as specified and as directed.
M&L Removing Complaint of Blockage (viz Blockage in Bath, Kitchen, WC & Drainage in Traps/Line from Trap to 1st Manhole, Blockage in Sewage Line from 1st Manhole to Septic Tank, Cleaning of Manhole) by deploying Trades Men as per Stipulated Time Frame from 9.00 AM to 5.00 PM and maintaining proper Records of COMPLETED and PENDING Complaints including Updating Status of Complaints through SMS/Manually for ZHOPRA COMPLEX at AF STATION SIRSA, complete all as specified and as directed. NOTE : FOR BOQ ITEM No. 1 TO 2 (a) If the Complaint is not attended/removed within a Day the Recovery will be levied on the Contractor for non-complelion of the Complaint at the Rate of Recovery included in Tender Document here-in-after. (b) It is mandatory on the Part of Contractor to deploy minimum 2 No. of Safaiwala/Mazdoor with requisite T&P throughout the Entire Contract Period. However required manpower and T & P, if required more to meet the requirement as mentioned in BOQ Item No. 1 to 3 is also to be arranged by the Contractor at his own Arrangements and Cost. Quoted Rates shall be deemed to include this factor and nothing Extra will be admissible on this account other than Quoted Rates for BOQ Item No. 1 to 3. In case of any dispute on this factor, the decision of Accepting Officer shall be final, conclusive and binding.
Desilting/Taking out Brick Bats, Pebbles, Silts, Muds, Clay, etc. from bottom of Drains including Cleaning Grasses, Vegitations, etc., depth upto 3.00 Metre including removing Excavated Materials from the Sides of Drain inluding removing RCC drain cover and refixing after cleanining of drain and removing debris to outside MD/AF Land where directed, complete all as specified and as directed.
M&L Cleaning Choked Sewer Lines of 100mm dia of any depth, Manually or thorough Mechanical Appliances and Making Sewer Line Functional complete including Working Under Foul Condition and depositing the sludge, rubbish, etc. off the Premises outside the MOD/AF Land or Sewage Treatment Plant, complete all as specified and as directed.
M&L Clearning Choked Sewer Lines of 150mm dia of any depth, Manually or thorough Mechanical Appliances and Making Sewer Line Functional complete including Working Under Foul Condition and depositing the sludge, rubbish, etc. off the Premises outside the MOD/AF Land or Sewage Treatment Plant, complete all as specified and as directed. NOTE : FOR BOQ ITEM No. 4 & 5 (a) If the Complaint is not attended/removed within a Day the Recovery will be levied on the Contractor for non-complelion of the Complaint at the Rate of Recovery included in Tender Document here-in-after. (b) It is mandatory on the Part of Contractor to deploy minimum 6 No. of Safaiwala/Mazdoor with requisite T&P throughout the Entire Contract Period. However required manpower and T & P, if required more to meet the requirement as mentioned in BOQ Item No. 4 & 5 is also to be arranged by the Contractor at his own Arrangements and Cost. Quoted Rates shall be deemed to include this factor and nothing Extra will be admissible on this account other than Quoted Rates for BOQ Item No. 4 & 5. In case of any dispute on this factor, the decision of Accepting Officer shall be final, conclusive and binding.
M&L Dewatering Sludge from Soakage Wells by Pumping out as required to keep the Complete Sewage System in order and as to avoid any Over flowing of Sewage Water including removing of Soak Well water pumped out as such Outside of Defence Land by means of Pumps and Tankers (Capacity of Water Tanker shall be 5000 Litres) as required including Operating and Supervisory Staff(s) so as to keep the whole Station area Pollution Free, complete all as specified and as directed. NOTE : Each Trip of Tanker to be taken Out side of MOD/AF Land in presence of JE in-Charge. This includes deployment of necessary T&P and nothing shall be Paid Extra.
M&L Desilting/Cleaning of Septic Tank and the like including Sludge Water and Solids Mechanically by HCV Mounted Suction Discharge Machine having Blow Back Facility with Sludge Tank and disposal of the same to Outside of MD/AF Land, complete all as specified and as directed. NOTE : Disilting/Cleaning of Septic Tanks shall be done for TWICE in the entire Contract Period.
M&L Removing Manhole Cover and Desludging/Desilting/Cleaning of existing Manholes of depth upto 1.50 Metre filled with Sludge by means of Manually or through Mechanical Appliances complete, Working Under Foul Condition and resetting the Manholes Cover in Position and depositing and removal of Sludge, Rubbish, etc. off the Premises Outside Defence Land, complete all as specified and as directed.
M&L Removing Manhole Cover and Desludging/Desilting/Cleaning of existing Manholes of depth exc. 1.50 Metre and not exc. 3.00 Metre filled with Sludge by means of Manually or through Mechanical Appliances complete, Working Under Foul Condition and resetting the Manholes Cover in Position and depositing and removal of Sludge, Rubbish, etc. off the Premises Outside of Defence Land, complete all as specified and as directed.
Demolition Cement Concrete (Unreinforced) of any description in Ground Floors, Pavings, etc. not exc. 150mm thickness (above or below Ground Level) and removing debris, etc. to Outside of MD/AF Land, complete all as specified and as directed.
Demolition Cement Concrete (Reinforced) of any description (above or below Ground Level) and removing debris, etc. to Outside of MD/AF Land, complete all as specified and as directed.
Demolition Brick work built in Cement Mortar and in any Position including all Quoins, Arches and Pillars, etc., complete all as specified and as directed.
Demolition & breaking up Drain Pipe 150mm dia (Salt Glazed Ware, AC or Reinforced Concrete) set in Cement Mortar, complete all as specified and as directed.
Dismantling Floor, Hearth or Wall Tiling including Cement Mortar Bedding (but not backing) and removing debris, etc. to Outside of MD/AF Land, complete all as specified and as directed.
Dismantling Pre-Cast Concrete Blocks of any description or thickness in Floors, Aprons, etc. and removing debris, etc. to Outside MD/AF Land, complete all as specified and as directed.
Taking down Cement Plaster including Raking out Joints, Hacking for Key, Scrubbing down with Water and removing debris, etc. to Outside of MD/AF Land, complete all as specified and as directed.
M&L Reinforced Concrete Pipes 150mm (internal dia), Class NP-3, laid in Trenches on Concrete Bed, to required Slope, jointed complete with Collers and tested, complete all as specified and as directed.
Excavating Over Areas not exc. 1.50 Metre deep and getting out in Soft/Loose Soil, complete all as specified and as directed.
Excavating Over Areas exc. 1.50 Metre but not exc. 3.00 Metre deep and getting out in Soft/Loose Soil, complete all as specified and as directed.
Excavating Over Areas exc. 3.00 Metre but not exc. 4.50 Metre deep and getting out in Soft/Loose Soil, complete all as specified and as directed.
Excavating in Trenches, not exc. 1.50 Metre wide and not exc. 1.50 Metre in depth; for Foundation, etc. or for Shafts, Wells, Cesspits, Manholes, Pier Holes, etc. not exc. 10 Sqm on Plan and not exc. 1.50 Metre in depth and getting out in Soft/Loose Soil, complete all as specified and as directed.
Excavating in Trenches, not exc. 1.50 Metre wide and not exc. 1.50 Metre in depth; for Foundation, etc. or for Shafts, Wells, Cesspits, Manholes, Pier Holes, etc. not exc. 10 Sqm on Plan and not exc. 1.50 Metre in depth and getting out in Hard/Dense Soil, complete all as specified and as directed.
Returning, filling in approved Soft/Loose Soil including spreading leveling, watering and well ramming in layers not exc. 25 Cm thick, complete all as specified and as directed.
Removing Excavated Materials (Soils) not exc. 50.00 Metre and depositing where directed at a level not exc. 1.50 Metre above the Starting Point including spreading over ground, complete all as specified and as directed.
M&L Cutting into existing Manholes for Connecting New Drain Pipes of 150mm (Internal dia), Making Good to Pipe and rendering, cutting out existing Benching for and forming Branch Channel (½ Round or ¾ Section) in Cement Concrete 1:2:4 (20mm crushed stone aggregate), Smooth Finished and Reforming Benching as required, complete all as specified and as directed.
M&L Loose Filling with Aggregates of gauge 80mm to 150mm (Broken Bricks) in Soakage Pits, Soakage Wells, etc., complete all as specified and as directed.
M&L Cement Concrete 1:4:8 type D2 (40mm crushed stone aggregate) in Foundation, Filling and Mass Concrete complete all as specified and as directed.
M&L Cement Concrete 1:3:6 (20mm crushed stone aggregate) in Surface Channels and Drains, etc. including use and waste Formwork as ordered, complete all as specified and as directed.
M&L Extra for Forming Fair finished Drain or Channel 30 Cm Inner Girth in Cement Concrete, using Extra Cement including Forms, Moulds, Stopped Ends, etc., complete all as specified and as directed.
Add to or Deduct from BOQ Item No. 29 here-in-above for Each 25mm Girth or Part thereof over or under 30 Cm in Cement Concrete, Using Extra Cement including Forms, Moulds, Stopped Ends, etc., complete all as specified and as directed.
M&L Cement Concrete 1:2:4 (20mm crushed stone aggregate) in Benching to Manhole including Forming Channel, laid to shape and Slope Coping, Plates including necessary Formwork and Fair Finished to Exposed Concrete Surfaces and Weathering, Slightly Rounded or Chamfered Angles and Throating, complete all as specified and as directed.
M&L Reinforced Cement Concrete 1:2:4 (20mm crushed stone aggregate) in Bands, etc., finished Even and Smooth without using Extra Cement, complete all as specified and as directed. NOTE : Formwork & Reinforcement will be Measured and Paid separately under relevant Items.
M&L Reinforced Cement Concrete 1:2:4 (20mm crushed stone aggregate) in Slabs supported on Walls, etc., finished Even and Smooth without using Extra Cement, complete all as specified and as directed. NOTE : Formwork & Reinforcement will be Measured and Paid separately under relevant Items.
M&L Pre-cast Reinforced Cement Concrete 1:2:4 (20mm crushed stone aggregate) in Slabs, Manhole Cover Slabs, etc., set in Cement Mortar 1:4, complete all as specified and as directed. NOTE : Reinforcement will be Measured and Paid separately under relevant Item.
M&L Brick Work with Sub-Class ‘B’ Bricks (Old Size Bricks), Straight or Curved on Plan exc. 6.0 Metre mean Radius, built in Cement Mortar 1:4, complete all as specified and as directed.
M&L Brick Work with Sub-Class ‘B’ Bricks (Old Size Bricks) in One Brick thick Walls Honey Comb Walling, built in Cement Mortar 1:4, complete all as specified and as directed.
M&L Use and Waste of Formwork in Curve to edges of Concrete, Sides of RCC/PCC Bands in Walls, horizontal or sloping, and similar work, complete all as specified and as directed.
M&L Use and Waste of Formwork to Soffits of Suspended Slab and similar work not exc. 200mm thick, Fair Finished surfaces, complete all as specified and as directed.
M&L TMT Bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for Columns, hooking Ends and binding with and including Mild Steel Wire (annealed) not less than 0.90 mm dia, complete all as specified and as directed.
M&L TMT Bars 6.0mm to 8.0mm dia, cut to length, bent to shape required including cranking, bending spirally for hooping for Columns, hooking Ends and binding with and including Mild Steel Wire (annealed) not less than 0.90 mm dia, complete all as specified and as directed.
S&F in repairs PVC (SWR) 75mm bore (dia), Branch Piece, Single (Single Y) Equal or Unequal with Access Door, etc., jointing with Solvent Cement, complete all as specified and as directed.
S&F in repairs PVC (SWR) 110mm bore (dia), Branch Piece, Single (Single Y) Equal or Unequal with Access Door, etc., jointing with Solvent Cement, complete all as specified and as directed.
M&L Cement Concrete 1:3:6 (40mm crushed stone aggregate) as in Concrete Bed to Drain Pipes of 150mm bore (dia), Including packing under, and haunching against the sides of pipes after they are laid and tested, complete all as specified and as directed.
M&L Cement Concrete 1:3:6 (40mm crushed stone aggregate) as in Bed to Drain Pipes of 150mm bore (dia), including Packing Under and Completely Surrounding Pipes with Concrete after they are laid and tested; complete all as specified and as directed.
S&F in repairs Angle Valve 15mm bore (dia), Cast Copper Alloy, Chromium Plated, screwed down, high pressure, screwed both Ends for Iron Pipe with Wall Flange, complete all as specified and as directed.
M&L Cement Concrete 1:2:4 (20mm crushed stone aggregate) 40mm thick in Floor, finishing Concrete Surfaces Even and Smooth with using Extra Cement, complete all as specified and as directed.
M&L Plastic Dividing Strips 38x1.5mm thick, inserted in Floor to confirm design, complete all as specified and as directed.
M&L Cement Concrete 1:2:4 (12.5mm crushed stone aggregate) 25mm thick in Levelling Course for laying Floor Tiles, finishing Concrete Surfaces Fair and Even, complete all as specified and as directed.
M&L for Non-skid Coloured Ceramic joint free tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceedig 0.11 Sqm but not exceeding 0.18 Sqm in Flooring, set and jointed in Neat Cement Slurry and pointed in White or Colour Cement to match the Tiles, laid over and including Screed or Screed Bed 15mm thick in Cement Mortar 1:6, complete all as specified and as directed. NOTE : Cost of Cement Screed Bed shall deem to be include in the Quoted Unit Rate.
M&L Coloured/Printed Glazed Ceramic Tiles 450x350x7mm thick in Vertical Surfaces i.e. Dado, Skirting, etc., set and jointed in Neat Cement Slurry and pointed in White or Colour Cement to match the Tiles, laid over and including Screed or Screed Bed 10mm thick in Cement Mortar 1:4, complete all as specified and as directed. NOTE : Cost of Cement Screed Bed shall deem to be include in the Quoted Unit Rate.
M&L Floor (Paver) Tiles 300x300x9.0 to 10mm, highly abrasive, Anti-skid, Impact Resistance, laid over and including 20mm thick Screed or Screed Bed in Cement Mortar 1:6, complete all as specified and as directed. NOTE : Cost of Cement Screed Bed shall deem to be include in the Quoted Unit Rate.
M&L Cement Concrete 1:4:8 (40mm crushed stone aggregate) 75mm thick in Sub-base under Pavements, etc., complete all as specified and as directed.
M&L Factory Made Machine Pressed Pre-cast Concrete Coloured 60mm thick of M-40 Grade Rubber Moulded with Rubber Polished Coating, Vibratory complacted Interlocking Paver Blocks with Spikes Marks on Top Surface, of any Shape and Size, conforming to IS:15658-2006 with Grey Cement and Pigment (as approved), laid dry over and including 25mm thick Sand Cushioning and Joints filled with Fine Sand, in Floor, complete all as specified and as directed. NOTE : Cost of Clean dry Sand shall deem to be include in the Quoted Unit Rate.
M&L Pre-cast Concrete Coloured Interlocking Paver Blocks (Serviceable Paver Blocks obtained from BOQ Item No. 53 here-in-before) laid dry over and including 25mm thick Sand Cushioning and Joints filled with Fine Sand, in Floor, complete all as specified and as directed. NOTE : Cost of Clean dry Sand shall deem to be include in the Quoted Unit Rate.
M&L Rendering 15mm thick in Cement Mortar 1:4 (Externally) on Fair Faces of Brick Walls or on Concrete Surfaces, mixing with WPC as per manufacturer's instructions, Plastered Surfaces finished Even and Smooth without using Extra Cement, complete all as specified and as directed. NOTE : WPC will be Measured and Paid separately as ‘Supply only’ under relevant Item.
Supply only Integral Water Proofing compound, conforming to IS and as approved, complete all as specified.
S&F in repairs PVC (SWR) Bend 75mm bore (dia), any radius with Access Door, etc. jointing with Solvent Cement, complete all as specified and as directed.
S&F in repairs PVC (SWR) Bend 110mm bore (dia), any radius with Access Door, etc. jointing with Solvent Cement, complete all as specified and as directed.
S&F in repairs Vitreous China White Squatting Pan of size 580x440mm, Orissa Pattern with Integral Foot Rests, ‘P’ or ‘S’ Trap, providing Joints between Flush Pipe and Socket of WC Pan, Cones, India Rubber (nozzles of WC Pan) incluiding provision of Lime Concrete Bedding and Making Good to Floor/distrubed surfaces, complete all as specified and as directed.
S&F in repairs Vitreous China White Wash Down Water Closet Pan (Pedestal Pattern) with Trap and Fixing Bolts (excluding Flushing Cistern and Flush Pipe) including connection to Outgoing Pipe and to Flushing Pipe, Anti-syphonage Pipe, etc. and Making Good to Floor /distrubed surfaces, complete all as specified and as directed.
S&F in repairs White Plastic Seat and Cover for Water Closet Pan (Pedestal Pattern), Closed Pattern with Flat bottom and Cover and Mild Steel Chromium plated or Aluminised Hinging Device, complete all as specified and as directed.
S&F in repairs PVC Flushing Cistern 10 Litre capacity White, Low Level, Valve less, Syphonic action type with Inlet, Ball Valve, Float and handle, a pair of Cast Iron Brackets Erecting Stand duly painted including cutting and pinning in Ends, Making Good Disturbed Surfaces in Cement Mortar 1:3, complete all as specified and as directed.
S&F in repairs PVC (SWR) Floor Trap 75mm bore (dia) with Grating including jointing to Waste Pipe fixed in Cement Concrete 1:2:4 (20mm crushed stone aggregate), complete all as specified and as directed.
S&F in repairs Salt-Glazed Stoneware Gully Traps of size 150x150mm, type P, Square or Round Mouthed, complete all as specified and as directed.
S&F in repairs PVC (SWR) 75mm bore (dia) Soil, Waste and Ventilating Pipe, single socketed, in any length with PVC Joints, with or without Ears, laid in Floors, complete all as specified and as directed.
S&F in repairs PVC (SWR) 110mm bore (dia) Soil, Waste and Ventilating Pipe, single socketed, in any length with PVC Joints, with or without Ears, laid in Floors, complete all as specified and as directed.
S&F in repairs PVC (SWR) 75mm bore (dia) Soil, Waste and Ventilating Pipe, single socketed, in any length with PVC Joints, with or without Ears, fixed to Walls, complete all as specified and as directed.
S&F in repairs PVC (SWR) 110mm bore (dia) Soil, Waste and Ventilating Pipe, single socketed, in any length with PVC Joints, with or without Ears, fixed to Walls, complete all as specified and as directed.
S&F in repairs PVC (SWR) Bends (any radius), Diminishing Pieces or Tapers (larger bore measured) Fittings for PVC (SWR) Pipe 75mm bore (dia), jointing with Solvent Cement, complete all as specified and as directed.
S&F in repairs PVC (SWR) Bends (any radius), Diminishing Pieces or Tapers (larger bore measured) Fittings for PVC (SWR) Pipe 110mm bore (dia), jointing with Solvent Cement, complete all as specified and as directed.
M&L in repairs Stack Clamps for PVC (SWR) Pipe 75mm/110mm bore (dia), made out of Flat Iron 50x5mm and 16mm dia Round Iron Stay including Bolts and Nuts and securing Ends of Stays to Wall or Roof, complete all as specified and as directed.
S&F in repairs PVC Connection Pipe 15mm size and 60 Cm in length with Adopter Nuts of PVC , complete all as specified and as directed.
S&F in repairs Jet Spray with Connection Pipe 15mm bore (dia), Brass Chromium Plated and suitable for Wash Down Water Closet Pan (Pedestal Pattern), complete all as specified and as directed.
M&L Mild Steel Framed Works such as Grills, Gratings, etc. with Ends of Bars shouldered and/or riveted or forged into Spikes; Framed Guard Bars; Barred Iron Doors; Ladders; Framed Balusters; Walkways; Railings; Framework of Water Tanks and similar Work, conforming to Fe-290, Gde-E-165, complete all as specified and as directed.
M&L Rough Cast Plaster on Brick Walls consisting Under Coat of Cement and Sand Mortar 1:3 not less than 10mm thick and while it is still in Plastic state the Rough Cast Mixture consisting of Crushed Stone or Fine Gravel mixed with Coarse Sand and Cement in the ratio 1:1:1 shall be applied and finish Even, complete all as specified and as directed.
Dismantling plain or corrugated steel/fibre sheeting of any gauge or thickness including nanital or similar pattern roof covering complete all as specified and as directed.
M & L 2mm thick fibre glass reinforced transulcent corugated sheeting with two corrugations side lap fixed fixed with coach screw and washer in roof wall complete all as specified.
Dismantiling structural steel or mild steel work of any description not otherwise provided for complete all as specified and as directed.
M&L for renewing of wall, floor, foot path, tiles in patches, area n exc 5 sqm including removing and cleaning old tiles, preparing beds and laying or setting jointing and pointing new or old tiles complete all as specified and as directed.
shiv shanker enterprises
M/s Shree Bala Ji Construction Company
royal associates
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .