Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.5 CrAccepted-AOC 379 B FIRST FLOOR CHIRAG DELHI NEW DELHI 110017 | NEW DELHI | SOUTH DELHI | DELHI | 110017 | ₹1.5 Cr | 1 | Accepted-AOC Found as the lowest bidder |
| 2 | 2₹1.7 Cr+₹28.5 L (19.5%)Rejected-Finance | ₹1.7 Cr+₹28.5 L (19.5%) | 2 | Rejected-Finance Not Found the lowest bidder |
| 3 | 3₹1.8 Cr+₹32.2 L (22.0%)Rejected-Finance | ₹1.8 Cr+₹32.2 L (22.0%) | 3 | Rejected-Finance Not Found the lowest bidder |
| 4 | 4₹1.9 Cr+₹44.2 L (30.3%)Rejected-Finance | ₹1.9 Cr+₹44.2 L (30.3%) | 4 | Rejected-Finance Not Found the lowest bidder |
| Sl No | Description | Qty | Unit | Superior Aircon Pvt. Ltd. L3 | BRITE INDUSTRIES L2 | aircon engineers L4 | AIR DESIGN SOLUTIONS L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Supply Installation Testing and Commissiong of 160 HP Hot & Cool VRF/VRV System comprises of outdoor VRF units (Minimum capacity of each unit 20 HP) and floor mounted high static tower type indoor units each of capacity not less than 8 TR, complete with interconnecting copper piping, electrical cabling, drain piping, (excluding cost of copper piping, drain piping and electrical cabling and same shall be measeured and paid as per separate BOQ item) mounting stand, centralized remote control unit etc. complete as required as per site requirement. (The VRF/VRV units shall have the ISEER values as defined in ECSBC 2024) | 1 | Job | 55,80,000 ₹55,80,000 | 69,84,000 ₹69,84,000 | 52,80,000 ₹52,80,000 Lowest | 59,60,795 ₹59,60,795 |
| 2.00 | Supply & Installation of copper refrigerent piping of sizes as per OEM design requirement alongwith accessories like bend, coupler, Y connection etc insulated with 19mm thick closed cell elastomeric nitrile tubular insulation between each set of indoor & outdoor units as per specifications properly supported and fixed on floor/ wall/ cable tray with hangers/clamps etc. complete as required (Cost of cable tray not included in this item). | 538 | Mtr | 1,500 ₹8,07,000 | 1,200 ₹6,45,600 Lowest | 1,750 ₹9,41,500 | 1,500 ₹8,07,000 |
| 3.00 | Supply & Installation of PVC Drain Piping of minimum dia 50mm complete with fittings like, bend, tee, etc. supports as per specifications and duly insulated with 9 mm thick closed cell nitrile rubber insulation etc. complete as required. | 210 | Mtr | 200 ₹42,000 | 370 ₹77,700 | 250 ₹52,500 | 150 ₹31,500 Lowest |
| 4.00 | Supply & Installation of control cum Interconnecting copper cable between indoor & outdoor units and from AC unit to the centralised remote control unit laid through suitable size of PVC conduit etc. complete as required. (3Cx2.5 Sq mm) | 538 | Mtr | 200 ₹1,07,600 | 120 ₹64,560 Lowest | 180 ₹96,840 | 187 ₹1,00,606 |
| 5.00 | Dismantling, Shifting and Reinstalltion of Existing 26 HP VRF unit alongwith 3 nos. Floor mounted Indoor Unit of LG Make VRF system including Pumpdown, vaccumising and leak testing, toping of refrigerent, testing & commissiong as per direction of EIC . [Complete VRF unit consists of 1 No 26 HP Outdoor unit and 3 Nos Indoor units ( 8 TR Floor mounted unit -2 Nos and 4 TR Floor mounted unit -1 Nos)] | 1 | Job | 1,50,000 ₹1,50,000 | 1,95,000 ₹1,95,000 | 1,80,000 ₹1,80,000 | 77,800 ₹77,800 Lowest |
| 6.00 | SITC of 4.0 TR Hot & Cool, 5 Star Rating Inverter type Floor mounted Tower Type Air-Conditioner with stabliser free operation suitable for 415 V+/(-)10% AC, 3 phase supply complete with refrigerant, interconnection between indoor & outdoor unit with suitable size copper flexible wire, refrigerant and drain piping up to 4 Mtrs etc. with copper condenser & evaporator coils, mounting stand for indoor and outdoor units etc. complete as required. | 3 | Job | 2,00,000 ₹6,00,000 | 2,60,000 ₹7,80,000 | 1,75,000 ₹5,25,000 | 1,20,816 ₹3,62,448 Lowest |
| 7.00Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders/mounted on wall/structure with MS angle (35x35x5 mm) including G.I. bolts & nuts, etc. as required. | |||||||
| 7.10 | 300 mm width X 50 mm depth X 1.6 mm thickness | 411 | Mtr. | 800 ₹3,28,800 | 650 ₹2,67,150 | 1,250 ₹5,13,750 | 618 ₹2,53,998 Lowest |
| 7.20 | 600 mm width X 50 mm depth X 2.0 mm thickness | 150 | Mtr. | 1,500 ₹2,25,000 | 1,375 ₹2,06,250 | 1,470 ₹2,20,500 | 1,118 ₹1,67,700 Lowest |
| 8.00Supplying and installing following size of Ladder Type Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns), in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders/mounted on wall/structure with MS angle (35x35x5 mm) including G.I. bolts & nuts, etc. as required. | |||||||
Tender Value
₹2.1 Cr
EMD Value
₹6.2 L
Closing Date
13 Oct 2025, 6:00 pmClosed
AGM (Engg-E) AAI Hindon Airport
Hindon Airport Ghaziabad Uttar Pradesh 201005
Augmentation of Airconditioning System in Terminal Building at CE Hindon
2025_AAI_248744_1
AAI/HINDON/ENGG(E)/VRF/2025-26
Open Tender
Electrical Works
Item Rate
120 days
Hindon Airport Ghaziabad
Please refer Tender documents.
17 documents required · 17 mandatory
₹1,180
₹6.2 L
Hindon Airport Ghaziabad
16 Mar 2026
22 Sept 2025
15 Oct 2025
22 Sept 2025
13 Oct 2025
22 Sept 2025
22 Sept 2025 - 29 Sept 2025
25 Sept 2025
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.81 MB
BOQ_286384.xls
BOQ • 0.39 MB
TenderDocumentVRV.pdf
Tender Documents • 14.15 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .