Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹9.2 LQualified Make: CUMMINS
Model: (Cummins - Jakson - Powered with Cummins make engine and Stamford alternator) (JSPF 125B) Without Installation 626 6TH FLOOR DLF TOWER A DLF TOWER 626 6TH FLOOR DLF TOWER A JASOLA JASOLA SOUTH DELHI DELHI 110076 | SOUTH DELHI | DELHI | 110076 | Make: CUMMINS
Model: (Cummins - Jakson - Powered with Cummins make engine and Stamford alternator) (JSPF 125B) Without Installation | L1 | Qualified | |
| 2 | L2₹9.3 L+₹9,960 (1.08%)Qualified Make: Koel Green Elmech
Model: KOEL GREEN KG1-125WS WITH PART NO. 318125-3002 NO 25-B 1402 1402 CHIRANJIV TOWER 43 NEHRU PLACE NEW DELHI 110019 NEHRU PLACE NEW DELHI UTTAR PRADESH 110019 | SOUTH EAST DELHI | DELHI | 110019 | Make: Koel Green Elmech
Model: KOEL GREEN KG1-125WS WITH PART NO. 318125-3002 NO 25-B | L2 | Qualified | |
| 3 | Disqualified Make: Koel Green Electro
Model: KOEL GREEN KG1-125WS3 With Part No. 318073-3102 20 23 BHAGWANPUR RAIPUR SAHKARI AUDYOGIC KSHETRA HARIDWAR UTTARAKHAND 247661 | HARIDWAR | UTTARAKHAND | 247661 | Make: Koel Green Electro
Model: KOEL GREEN KG1-125WS3 With Part No. 318073-3102 | - | Disqualified | |
| 4 | Disqualified Make: MAHINDRA - GSP
Model: GSP/125/TP/C2-F4 B 2 16 MOHAN COOPERATIVE INDUSTRIAL ESTATE BADARPUR BORDER NEW DELHI SOUTH DELHI DELHI 110044 | SOUTH EAST DELHI | DELHI | 110044 | Make: MAHINDRA - GSP
Model: GSP/125/TP/C2-F4 | - | Disqualified | |
| 5 | Disqualified Make: MAHINDRA GSP RETAIL
Model: MAHINDRA 125KVA MECH CPCB2 22 IIIRD FLOOR MAIN MARKET MOTI NAGAR DELHI DELHI 110015 | WEST DELHI | DELHI | 110015 | Make: MAHINDRA GSP RETAIL
Model: MAHINDRA 125KVA MECH CPCB2 | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
16 Aug 2018, 9:00 amClosed
diesel generators- DG Sets Diesel Generators- DG Sets ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values OUTPUT CAPACITY RATING/PHASE Nominal Rated Capacity (KVA) 125 As per GeM Catalogue. (or higher) No of Phase - Single phase
Three Phase ENGINE Make of Engine - - Model Number of Engine - - Capacity of Engine (cc) - - Engine Power (kWm) - - ISI Marking to IS :10001 for engine false - BIS license No
if applicable - - Type of Engine cooling Liquid Cooled Air Cooled
Liquid Cooled Type of governer Mechanical Mechanical
Electronic (or higher) Class of governer A2 A0
A1
A2 (or higher) Number of cylinders (nos) 4 - No of Strokes (nos) 4 - 1/4 Rated RPM of Engine (RPM) - 1500
3000 Overload capacity for one hour for every 11 hours continuous running at full load (%) 10 - Specific Fuel Consumption (gm/kWh) - - Starting voltage (volt) 12 - ALTERNATOR AC GENERATOR(ALTER NATOR) Make - - AC GENERATOR(ALTER NATOR) model Number - - Rating of AC Generator (KVA) 125 - Power Factor of AC generator 0.8 - Efficiency at rated Power factor at 75% of full Load 93.16 - Compliance of Alternator to IS:13364(part-1) Yes - Type of alternator Brushless - Voltage Regulation Grade VG 3 - Alternator IP Rating IP 23 - Class of Insulation H - CONTROL PANEL Control Panel Manual Manual
AMF IP Rating of Control Panel IP 53 - ACOUSTIC ENCLOSURE Sheet Thickness 2 1.6
1.8
2
1.2 Higher is better Thickness of Foam 40 - Density of Foam for sound insulation 20 - Noise level at 1 meter (dB) 75 - BATTERY Battery Type & Specification Low Maintenance free to IS: 14257 for high cranking performance - Battery capacity (Ah) - - No of batteries 1 - TEST REPORTS Availability of Type test report for Engine from Yes - 2/4 Central govt/NABL/ILAC accredited laboratory Test Report number and date(Engine) - - Name and address of laboratory(Engine) - - Availability of Type test report for Alternator from Central government/NABL/ILAC accredited laboratory Yes - Test Report number and date(Alternator) - - Name and address of laboratory(Alternator) - - DG set meet requirements of Enviro nmental(Protection) Rules 1986
in respect of noise and emission norms
as described in STC Yes - WARRANTY INSTALLATION & COMMISSIONING Warranty 2 Installation & Commissioning Without Installation Without Installation Agreed to STC of the Product Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Madan Goyal 796025
shq bsf azl durtlang north aizawl mizoram 796025 1 30
403617
GEM/2018/B/57120
diesel generators- DG Sets
30 days
Mizoram
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| diesel generators- DG Sets Diesel Generators- DG Sets ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values OUTPUT CAPACITY RATING/PHASE Nominal Rated Capacity (KVA) 125 As per GeM Catalogue. (or higher) No of Phase - Single phase | - | - | - |
| Three Phase ENGINE Make of Engine - - Model Number of Engine - - Capacity of Engine (cc) - - Engine Power (kWm) - - ISI Marking to IS :10001 for engine false - BIS license No | - | - | - |
| if applicable - - Type of Engine cooling Liquid Cooled Air Cooled | - | - | - |
| Liquid Cooled Type of governer Mechanical Mechanical | - | - | - |
| Electronic (or higher) Class of governer A2 A0 | - | - | - |
| A1 | - | - | - |
| A2 (or higher) Number of cylinders (nos) 4 - No of Strokes (nos) 4 - 1/4 Rated RPM of Engine (RPM) - 1500 | - | - | - |
| 3000 Overload capacity for one hour for every 11 hours continuous running at full load (%) 10 - Specific Fuel Consumption (gm/kWh) - - Starting voltage (volt) 12 - ALTERNATOR AC GENERATOR(ALTER NATOR) Make - - AC GENERATOR(ALTER NATOR) model Number - - Rating of AC Generator (KVA) 125 - Power Factor of AC generator 0.8 - Efficiency at rated Power factor at 75% of full Load 93.16 - Compliance of Alternator to IS:13364(part-1) Yes - Type of alternator Brushless - Voltage Regulation Grade VG 3 - Alternator IP Rating IP 23 - Class of Insulation H - CONTROL PANEL Control Panel Manual Manual | - | - | - |
| AMF IP Rating of Control Panel IP 53 - ACOUSTIC ENCLOSURE Sheet Thickness 2 1.6 | - | - | - |
| 1.8 | - | - | - |
| 2 | - | - | - |
| 1.2 Higher is better Thickness of Foam 40 - Density of Foam for sound insulation 20 - Noise level at 1 meter (dB) 75 - BATTERY Battery Type & Specification Low Maintenance free to IS: 14257 for high cranking performance - Battery capacity (Ah) - - No of batteries 1 - TEST REPORTS Availability of Type test report for Engine from Yes - 2/4 Central govt/NABL/ILAC accredited laboratory Test Report number and date(Engine) - - Name and address of laboratory(Engine) - - Availability of Type test report for Alternator from Central government/NABL/ILAC accredited laboratory Yes - Test Report number and date(Alternator) - - Name and address of laboratory(Alternator) - - DG set meet requirements of Enviro nmental(Protection) Rules 1986 | - | - | - |
| in respect of noise and emission norms | - | - | - |
| as described in STC Yes - WARRANTY INSTALLATION & COMMISSIONING Warranty 2 Installation & Commissioning Without Installation Without Installation Agreed to STC of the Product Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Madan Goyal 796025 | - | - | - |
| shq bsf azl durtlang north aizawl mizoram 796025 1 30 | - | - | - |
Exempted
16 Aug 2018
30 Jul 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_403617.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .