Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.8 LAccepted-AOC BIR SARDALIA RESIDENCY AIR FORCE ROAD BARYAL UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | ₹28.8 L | L1 | Accepted-AOC Accepted being lowest |
| 2 | L2₹31.6 L+₹2.8 L (9.60%)Rejected-Finance NEAR JAMIA MASJID HOSPITAL ROAD UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | ₹31.6 L+₹2.8 L (9.60%) | L2 | Rejected-Finance Not lowest bidder |
| 3 | L3₹31.7 L+₹2.9 L (9.89%)Rejected-Finance DAYA BAGH SATTANI DHAR ROAD UDHAMPUR DISTT UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | ₹31.7 L+₹2.9 L (9.89%) | L3 | Rejected-Finance Not lowest bidder |
| 4 | L4₹36.4 L+₹7.5 L (26.1%)Rejected-Finance NEAR INDUSTRIAL ESTATE THANDA PADDAR UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | ₹36.4 L+₹7.5 L (26.1%) | L4 | Rejected-Finance Not lowest bidder |
| Sl No | Description | Qty | Unit | K S BUILDERS L4 | M/SHansrajbuilder L3 | SARDALIA CONST CO L1 | CITY TOP ELECTRICAL WORKS L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Taking out old existing unserviceable metal plug socket and supply and fix new metal plug and socket board complete enclosure with single pole & neutral and earth plug with MCB SP 32/40 Amps, 220 Volts complete suitable for window/ Split type complete all as specified and directed by Engr-in- charge. | 25 | Each | 350 ₹8,750 | 600 ₹15,000 | 200 ₹5,000 Lowest | 600 ₹15,000 |
| 2.00 | Taking out old existing unserviceable DB two Way and MCB SPN 40 Amps and Supply and fix Sheet Metal Enclosure with DBs single pole and neutral 2 Way, 240 volts by with one SPN MCB of capacity 40 Amps complete all as specified and directed by Engr-in- charge. | 15 | Each | 320 ₹4,800 | 300 ₹4,500 | 200 ₹3,000 Lowest | 400 ₹6,000 |
| 3.00 | Taking out old existing unserviceable front show grill and supply and fix new front show grill for any make of window type /Split AC 1.5 Ton complete all as specified and directed by Engr-in-charge. | 10 | Each | 1,050 ₹10,500 | 400 ₹4,000 | 200 ₹2,000 Lowest | 800 ₹8,000 |
| 4.00 | Taking out old existing unserviceable reversible type inner unit of split type AC of capacity 1.5/2.0 Ton and supply and fix new inner unit of split type AC of capacity 1.5 /2.0 Ton as existing shape, size and make complete all as specified and directed by Engr –in – charge. | 25 | Each | 12,500 ₹3,12,500 | 17,500 ₹4,37,500 | 18,000 ₹4,50,000 | 10,900 ₹2,72,500 Lowest |
| 5.00 | Taking out old existing unserviceable reversible type outer unit of split type AC of capacity 1.5/2.0 Ton and supply and fix new outer unit of split type AC of capacity 1.5 /2.0Ton existing shape and size without compressor complete all as specified and directed by Engr –in – charge. | 25 | Each | 16,500 ₹4,12,500 | 17,500 ₹4,37,500 | 18,000 ₹4,50,000 | 10,900 ₹2,72,500 Lowest |
| 6.00Disconnecting from electrical system carrying to workshop & back to store/site after repair dismantling the voltage stabilizer of capacity 5KVA,2KVA,1KVA,0.5KVA thoroughly checking,cleaning all parts by brushing and assembling after replacement of required burnt unserviceable parts / components, testing and comminssioning complete after necessary repair / replacement of components as below complete all as specified and directed by Engr-in- charge.:- | |||||||
| 7.00 | M&L rewinding of main coil (primary/secondary) with super enabled copper wire of existing size including varnishing and insulation material of capacity 5KVA complete all as specified and directed by Engr-in- charge. | 15 | Each Job | 750 ₹11,250 | 700 ₹10,500 | 300 ₹4,500 Lowest | 800 ₹12,000 |
| 8.00 | Description all as per ser item No.07 here - in-before but of capacity 2KVA complete all as specified and directed by Engr-in- charge. | 15 | Each Job | 686 ₹10,290 | 600 ₹9,000 | 300 ₹4,500 Lowest | 500 ₹7,500 |
| 9.00 | Description all as per ser item No.07 here - in-before but of capacity 1KVA complete all as specified and directed by Engr-in- charge. | 10 | Each Job | 486 ₹4,860 | 600 ₹6,000 | 300 ₹3,000 Lowest | 400 ₹4,000 |
| 10.00 | Description all as per ser item No.07 here - in-before but of capacity 0.5KVA complete all as specified and directed by Engr-in- charge. | 10 | Each Job | 396 ₹3,960 | 400 ₹4,000 | 300 ₹3,000 | 30 ₹300 Lowest |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
22 Aug 2026, 6:00 pmClosed
GE Army Dhar Road
GE Army Dhar Road
REPAIR MAINT OF COOLING APPLIANCES AND CONNECTED WORKS AT DHAR ROAD AND JINDRAH UNDER GE ARMY DHAR ROAD
2026_MES_780901_1
8072/NIT-44/2026-27
Open Tender
Civil Works
Item Rate
180 days
GE Army Dhar Road
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE Army Dhar Road
₹96,000
Yes
5 Sept 2026
25 Jul 2026
24 Aug 2026
26 Jul 2026
22 Aug 2026
8 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking out old existing unserviceable metal plug socket and supply and fix new metal plug and socket board complete enclosure with single pole & neutral and earth plug with MCB SP 32/40 Amps, 220 Volts complete suitable for window/ Split type complete all as specified and directed by Engr-in- charge. | 25 | Each | - | - |
| 2 | Taking out old existing unserviceable DB two Way and MCB SPN 40 Amps and Supply and fix Sheet Metal Enclosure with DBs single pole and neutral 2 Way, 240 volts by with one SPN MCB of capacity 40 Amps complete all as specified and directed by Engr-in- charge. | 15 | Each | - | - |
| 3 | Taking out old existing unserviceable front show grill and supply and fix new front show grill for any make of window type /Split AC 1.5 Ton complete all as specified and directed by Engr-in-charge. | 10 | Each | - | - |
| 4 | Taking out old existing unserviceable reversible type inner unit of split type AC of capacity 1.5/2.0 Ton and supply and fix new inner unit of split type AC of capacity 1.5 /2.0 Ton as existing shape, size and make complete all as specified and directed by Engr –in – charge. | 25 | Each | - | - |
| 5 | Taking out old existing unserviceable reversible type outer unit of split type AC of capacity 1.5/2.0 Ton and supply and fix new outer unit of split type AC of capacity 1.5 /2.0Ton existing shape and size without compressor complete all as specified and directed by Engr –in – charge. | 25 | Each | - | - |
| 6 | Disconnecting from electrical system carrying to workshop & back to store/site after repair dismantling the voltage stabilizer of capacity 5KVA,2KVA,1KVA,0.5KVA thoroughly checking,cleaning all parts by brushing and assembling after replacement of required burnt unserviceable parts / components, testing and comminssioning complete after necessary repair / replacement of components as below complete all as specified and directed by Engr-in- charge.:- | - | - | - | - |
| 7 | M&L rewinding of main coil (primary/secondary) with super enabled copper wire of existing size including varnishing and insulation material of capacity 5KVA complete all as specified and directed by Engr-in- charge. | 15 | Each Job | - | - |
| 8 | Description all as per ser item No.07 here - in-before but of capacity 2KVA complete all as specified and directed by Engr-in- charge. | 15 | Each Job | - | - |
| 9 | Description all as per ser item No.07 here - in-before but of capacity 1KVA complete all as specified and directed by Engr-in- charge. | 10 | Each Job | - | - |
| 10 | Description all as per ser item No.07 here - in-before but of capacity 0.5KVA complete all as specified and directed by Engr-in- charge. | 10 | Each Job | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.43 MB
BOQ_874770.xls
BOQ • 0.78 MB
Tender44.pdf
Tender Documents • 2.13 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .