Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.3 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹36.2 L+₹4.8 L (15.2%)Rejected-Finance | L2 | Rejected-Finance Being higher bid value | |
| 3 | L3₹38.1 L+₹6.7 L (21.4%)Rejected-Finance 89A UPEN BANERJEE ROAD PARNASREE BEHALA KOLATA 700060 WEST BENGAL | KOLKATA | WEST BENGAL | 700060 | L3 | Rejected-Finance Being higher bid value | |
| 4 | L4₹39.4 L+₹8.1 L (25.7%)Rejected-Finance 24B JYOTISH ROY ROAD KOLKATA 700053 | KOLKATA | WEST BENGAL | 700053 | L4 | Rejected-Finance Being higher bid value |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
21 Dec 2022, 6:00 pmClosed
GE ALIPORE KOLKATA
NO 1 NATIONAL LIBRARY AVENUE, ALIPORE, KOLKATA 700027
PROVN OF SOUND PROOFING IN ENT OPD AT CH (EC), PROVN OF CLOTH DRYING T-ROD FOR SINGLE ACCN NEAR BLDG NO P-04, P-08, P-09 AND P-10 OF EMB HQ AND ADDN /ALTN TO MEDICINE STORAGE SHED OF CH (EC), PROVN OF 30 X 25 LTRS GEYSER FOR NURSING CADET MESS (P-29)
2022_MES_551936_3
GE/ALP (8085B) OF KOLKATA 2022-23
Open Tender
Civil Works
Item Rate
120 days
GE ALIPORE KOLKATA
Class D and category a (i)
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER ALIPORE
₹60,000
Yes
13 Jan 2023
30 Nov 2022
23 Dec 2022
30 Nov 2022
21 Dec 2022
7 Dec 2022
Amount
Taking down cement plaster including tiles on brick or stone wall surfaces including glazed tiles wherever exists including raking out joints, hacking for key and scrubbing down with water complete all as specified and as directed.
Demolition of brick or strone / boulder work built in cement mortar including all quoins, arches, pillars etc complete all as specified and as directed
Material and labour for brick work with subclass B brick straight or curved on plan exc. 6m mean radius , built in cement mortar (1:6) complete all as specified and as directed by Engineer-in-Charge.
Material and labour for brick work with sub-class `B' bricks old size, straight or curved on plan to any radius in half brick thick walls built in cement mortar (1:4) complete all as specified and as directed.
Material and labour for 15 mm thick rendering on fair faces of brick work or concrete surfaces in cement mortar (1:4) surface finished even and smooth without using extra cement with water proofing compound complete all as specified and as directed.
Material and labour for 15 mm thick rendering on other than fair faces of brick work or concrete surfaces in cement mortar (1:6) surface finished even and smooth without using extra cement with water proofing compound complete all as specified and as directed.
Supply and fixing Elegant tile made of perfocated cement fibre composite 595x595x9mm(any colour/pattern) covered with absorptive microfibre coating on the front side and accoustics fibre on the back side ,water resitance ,fire absorption coefficient upto .89 at 160HZ tested as per ISO 354 . The tiles are anti sag and installed on50mm x50mm wooden scantling grid system with a backing of 50mm 1000GSM thxik absorb wool tested as fire retardent IS 15061-2002 for excellent results. complete all as specified and as directed.
Supply and fixing Elegant tile made of perfocated cement fibre composite 595mmx595mmx9mm(any colour/pattern) covered with absorptive microfibre coating on the front side and accoustics fibre on the back side ,water resitance ,fire absorption coefficient upto .89 at 160HZ tested as per ISO 354 . The tiles are anti sag and installed on T 24 grid system of .6mm thick main 'T' length minimum 3000mm ,web minimum 35 mm to be placed at 600mm centre to centre and secondary cross ''T'' of length 600 web min 35 mm inter locked ,wire supporter for main T to be taken at every 1200 mm lengh wise and 600mm width wise with a backing of 50mm 1000GSM thxik absorb wool tested as fire retardent IS 15061-2002 for excellent results.
Supply and fixing in repair 30 mm thick flush door/Window including necessary builder hardware with Elegant tile made of perfocated cement fibre composite 595x595x9mm (any colour/pattern) covered with absorptive microfibre coating on the front side and accoustics fibre on the back side ,water resitance ,fire absorption coefficient upto .89 at 160HZ tested as per ISO 354 . The tiles are anti sag and installed on50mm x50mm wooden scantling grid system with a backing of 50mm 1000GSM thxik absorb wool tested as fire retardent IS 15061-2002 for excellent results. complete all as specified and as directed.
Supply and fixing 12mm thick Plywood grade BWR, type BB fixed to walls with necessary fittings and fixtrures etc complete all as specified and as directed.
Supply and fixing 25mm thick Bonded mineral wool blanket/ slab made from glass, density 24 kg/cu m fixed to walls/ceilings with necessary fittings and fixtrures etc complete all as specified and as directed.
Supply and fixing second class hard wood (sal) plain, solid, straight chowkhats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed.
Material and labour for RCC(Nominal Mix) in type-B1 (1:2:4) (Using 20mm graded stone aggregate) slabs supported on walls for cup board and Kitchen slabs including necessary form work complete all as specified and as directed.
Material and labour for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required including cranking, bending, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming complete and all as specified and as directed.
Supply and fixing 20 mm bore brass elbow/Tee/fta/mta CPVC complete all as specified and as directed.
Supply and fixing 20 mm bore (Outer dia) CPVC pipes of SDR 11and plain CPVC SDR 11 fitting fixed on wall or floor (concealed ), ceiling or laying in floors complete all as specified and as directed.
Supply and fixing 50 mm bore (Outer dia) UPVC pipes of SCH-40 and plain UPVC SDR 11 fitting fixed on wall or floor, ceiling or laying in floors complete all as specified and as directed.
Supply and fixing 15mm bore CP angular valve,with crutch handle, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed.
Supply and fixing 600 mm long PVC connection 15 mm size with PTMT nut complete all as specified and as directed.
Supply and fixing 5 mm thick beveled edge best quality fancy looking mirror fixed in wall with screws complete all as specified and as directed.
Supply and fixing vitreous china counter wash hand basin Ivory colour, white, flat back, size 550mm x 400mm, including cutting for and pinning in ends of and including brackets, waste pipe & CP brass waste coupling of 32mm dia complete all as specified and as directed. (Make :- Cera (Cat no-S2030103) or equivalant as approved by the GE)
Supply and fixing CP Towel rail 600 mm long 20mm dia fixed with and including chromium plated brass screws & wooden/plastic cleats. complete all as specified and as directed.
Supply and fixing 15 mm bore pillar cock swan neck spout and aerator, Chromium Plated, with capstan heads, chromium plated, Fancy type screwed down for pipe, high pressure with long screwed shanks and fly-nuts complete all as specified and as directed. (Make :- Cera (Cat No- F 2008105) or equivalent as approved by the GE)
Supply and fixing as 15 mm bore Brass CP Surgical Elbow operated tap for wall/pillar, screwed down for iron pipe and fixed complete all as specified and as directed by the Engr in Charge. (Make: Jaquar Cat No FLR-CHR 5166 or equivalent as approved by the GE)
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
Material and labour for Granite(of any type) tiles 18 mm thick for slab machine cut, bedded & jointed with grey cement slurry & pointed with white cement with admixture of pigment to match the shade of granite stone over and including 15 mm thick screed bed in cement mortar (1:4) including grinding & polishing fixed in floor,window cills, shleves,counters complete all as specified and as directed.
Material and labour for light shade Vitrified ceramic tiles 9-10 mm thick (Sqr/ rectangular) Polished, area of each tiles n.exc. 0.36sqm, in floors etc. set and jointed in neat cement slurry over and including a bedding layer of screed bed 15 mm thick in cement mortar (1:4) and pointed in white/colour cement to match. complete all as specified and as directed.
Material and labour for coloured, glazed ceramic tiles size 450x300x 6-7mm thick, in dado/skirting etc, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match, laid with and including over10 mm thick rendering in cement mortar (1:3) complete all as specified and as directed.
Material and labour for preparing surfaces new decorated plastered or unplastered surfaces of wall, pillasters, cornices etc and applying two coat of acrylic distemper etc complete all as specified and as directed.
Material and labour for preparing new plastered surfaces and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm etc complete all as specified and as directed.
Material and labour for applying 3mm thick wall care putty on newly plastered surfaces to make smooth and even to receive wall finishes etc complete all as specified and as directed.
Material and labour for preparing old decorated plastered or unplastered surfaces of wall, pillasters, cornices etc and applying two coat of acrylic distemper and 2mm thick wall care putty complete all as specified and as directed.
Excavating in post holes (or similar holes) each n.exc 0.5cu m, getting 0ut,returning,filling in & ramming earth or broken rubble mixed with earth around, in layers not exceeding, 25cm watering & removing surplus soil to a distance n exc 50m and making good surface in soft/loose soil complete all as specified and as directed.
Material and labour for Surface excavation n.exc. 30 cm deep and averaging 15 cm deep and getting out in in Soft loose soil complete all as specified and as directed.
Material and labour for broken stone boulders Hard core, broken to gauge n exc 63 mm,deposited,spread and levelled in layered n.exc. 15cm thick, watered and rammed to a true surfaces complete all as specified and as directed.
Material and labour for 75 mm thick PCC(1:4:8) type D-2 (using 40mm graded stone aggregate) as in sub base complete all as specified and as directed.
Material and Labour for Cement concrete (1:3:6) type C-2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed.
Material and labour for coloured cement concrete chequered tiles 20-25 mm thick and area of each tile exc .07 sqm but not exc 0.16 sqm set, jointed and pointed in neat cement slurry in floors complete all as specified and as directed.
Material and labour for 20mm thick screed bed or bedding in cement mortatr (1:6) for laying of floor fishes complete all as specified and as directed.
Removing excavated material exc. 1.50 km but n exc. 5 km and depositing where directed complete all as specified and as directed.
Supply and fixing for joist, channel, angle, or tee section, fixed independantly, without connecting plates, etc. as in fencing post conforming to Fe 410 W (gde E-250 quality B) complete all as specified and as directed.
Material and labour for two coat of synthetic enamel paint over a coat of red oxide zinc chrome primer including preparation on new steel surfaces of any description over 10 cm width or girth complete all as specified and as directed.
Supply and fixing Galvanised wire 5mm dia fixed to pole complete all and as directed by the Engr in charge.
Material and labour for 100mm thick cement concrete (1:4:8) type D2 (using 40 mm graded stone aggregate) as in sub base complete all as specified and as directed by the Engr-in-Charge.
Material and labour for 40mm thick PCC (1:2:4) type 'B-0' (using 12.5 mm graded crushed stone aggregate) as in flooring complete all as specified and as directed.
Material and labour for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and inlcuding 15mm thick screed bed in cement morter (1:4) complete all as specified and as directed by the Engr-in-Charge.
Supply and fixing powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed.
Supply and fixing powder coated aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and as directed.
Supply and fixing powder coated aluminium partition, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and as directed.
Supply and fixing for Powder coated aluminium sliding windows for three track with rubber gasket, stopper powder coated aluminium standard beads/glazing clips ,locking arrangement etc and aluminium frame of size 80mmX25mmX1.55mm and shutter of section 20mm X20mm X1.55mm incl ( two shutter of 4.8mm thick glass and one shutter of wiremesh 0.36 mm dia of wire and average width of aperture 1.40 mm) with necessary all fittings complete all as per manufacturer's instructions and all as specified and as directed by the Engr-in-Charge.
Supply and fixing 4.8 mm thick sheet glass, ordinary quality and glazing with oil putty in squares exceeding 0.5 Sqm in each pane complete all as specified and as directed.
Material and labour for backing coat/Screed bed or bedding layer of mortar 10 mm thick in cement mortar (1:4) as in dado/skirting complete all as specified and as directed.
Material and labour for Glazed ceramic coloured wall tiles of size 450X300X7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles. complete all as specified and as directed. (Note:- Screed bed shall be measured and paid Seperately under respective items of Sch)
Supply and fixing in repair PVC (SWR)110mm pipes single socketed in any length with rubber ring joints and laid in trenches or in floor complete all as specified and as directed :-
Material and labour for point wiring surface type for one geyser point Independent, with cables 4 sq. mm size PVC (FR-LSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade controlled by one one way switch socket combination on independent board including 4.0 sqmm PVC(FR-LSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade for continuity earth wire connected to common earth dolly drawn through and including PVC casing capping with all accessories and sunk cast pressed steel terminal box made out of MS sheet 1.25mm thick for mounting of fittings like switch, socket and fan regulator with 3mm thick bakalite sheet cover for fixing of switch socket as per site requirement complete all as specified and as directed.
Supply and fixing vertical storage type water heater (Geyser) of capacity 25 Ltrs with copper tank, 230 volts BEE 5 star rated, including all accessories such as PVC inlet connector pipe 450mm long, 450mm long brass CP conector with 2 nuts without nipple fixing the geyser with four Nos of rag bolts and making the electrical/water supply connection including testing after installation complete all as specified and as directed. (Make : Recold /Havells/Crompton/Bajaj.)
Supply and fixing for single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCBs 20 Amps 230 volts flush type with fuse & neon incator complete all as specified and as directed. (Make: Legrand/L&T Havells.)
Supply and fixing of GI pipe 20 mm dia medium grade with all fitting and fixed complete wall and ceilings etc for incoming cold water and outgoing hot water complete all as specified and as directed by Engr-in- cahrge .
Supply and fixing stop valves , cast copper alloy chromium plated scerwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or union complete of size 15 mm dia.
Supply and fixing bib taps, cast copper alloy fancy type chromium plated scerwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or union complete of size 15 mm dia.
Material and labour for point wiring (modular fittings) complete with 1.5 sq mm single core multi stranded copper conductor PVC (FRLSH) insulated unsheathed cable confirming to IS-694,1100 Volts grade ISI Marked in and including PVC rigid conduit MMS ISI marked with accessories concealed in wall / roof / ceiling etc and including sunken pressed steel terminal boxes for modular in wall but including modular white cover with frame and 1.50 sq mm PVC insulated unsheathed stranded copper conductor for common earth and connecting to earth dolly for one light/fan/Bell point controlled by one way switch. complete all as specified and as directed.
All as per item No. 61 here-in-before but for 3 pin 6 Amps same board with other switches with cable 1.5 Sqmm size.complete all as specified and as directed.
All as per serial item No. 61 above, but for one 3 pin, 5 Amp socket, independent board, complete all as specified and as directed.
All as per serial item No. 61 above, but for one 3 pin, 5 Amp socket, adjacent/just below, complete all as specified and as directed.
All as per item 61 above but for 3 pin 15 Amp socket outlet independent with PVC unsheathed, multistrand copper conductor of 2.5 Sqmm and continuous PVC insulated and unsheathed 2.5 Sqmm copper conductor cable multistrand as earth wire. complete all as specified and as directed.
All as per item 61 above but for 3 pin 15 Amp socket outlet independent with PVC unsheathed, multistrand copper conductor of 4.0 Sqmm and continuous PVC insulated and unsheathed 4.0 Sqmm copper conductor cable multistrand as earth wire for Air conditioner. complete all as specified and as directed.
Material and labour for Sub main wiring with two single core PVC insulated unsheated FRLS copper conductor cable of size 6 sqmm and one single core PVC insulated unsheathed (FRLS) copper conductor cable of size 6 Sqmm as earth lead in and indlucing concealed PVC conduit, ISI marked and making good the disturbed, surface complete all as specified and as directed. (Note: Two runs of 6 Sqmm cable, one run of 6 Sqmm earth wire and one run PVC conduit shall be measured as one unit of one Running Metre.)
Supply and fixing of Modular switch single pole, one way, 6 Amp, 1 module, complete all as specified and as directed.
Supply and fixing of Modular switch single pole, one way, 16 Amp, 1 module, complete all as specified and as directed.
Supply and fixing of Modular Socket, 6 Amp, 2/3 pin combined 2 module, complete all as specified and as directed.
Supply and fixing of Modular Socket, 6/16 Amp, 2/3 pin combined 2 module, complete all as specified and as directed.
Supply and fixing of Modular Bell push 6 Amp, single pole, 1 module, complete all as specified and as directed.
Supply and fixing of Bell Buzzer/ding dong type, complete all as specified and as directed.
Supply and fixing of Ceiling rose 3 terminal PVC/ polycarbonate, isolated body fixed on PVC round block, complete all as specified and as directed.
Supply and fixing of Modular step type fan regulator, 120W, 2 module, complete all as specified and as directed.
Supply and fixing of Sheet metal enclosure for DB's (Double door), IP-43 IK-09 proctection suitable for MCB single pole and neutral, 4 way, 240 Volts with 200 Amp rated busbar, fixed flush in wall, complete all as specified and as directed. (Note : MCBs shall be measured and paid for seperately).
Material and labour for power supply unit consisting of starter with 20 Amps over load protection, MCB-20 Amps, 2 pin & earth plug socket including MS/PVC box & top cover for AC. complete all as specified and as directed. Make :Legrand/Crabtree/Cona
Supply and fixing in repair 2'x2' energy efficient recess mounting 24 watt LED lumanaries fixing for POP ceiling housing including LED lamps other accessories and necessary electric connection after and including taking down old unserviceable fittings complete all as specified and as directed. Make : Havells, Model No. Octane+ LED Panel Square, Cat No.LHEBAEP7IZ1W024 or equivalent in Phillips/CG.
Material and labour for MCB SP of rating 6 to 32 Amps 240 V of capacity 10 KA, "C" Series ISI Marked. complete all as specified and as directed.
Material and labour for MCB SPN of rating 40 to 63 Amps Amps 240 V,of capacity 10 KA, "C" Series ISI Marked. complete all as specified and as directed.
Supply and installation, commissioning Air conditioner split units indoor and outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality electric driven, single phase of capacity 2.0 TR, BEE 5 star rated complete with all accessories. complete all as specified and as directed. (Make :- Blue star/Voltas/Carrier/LG)
Supply and installation Air conditioner hi wall split units indoor and outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 1.5 Ton. complete all as specified and as directed. (Make : Bluestar / Voltas/Carier/LG)
All as per item No 61 here-in-before but for 3 pin 6 Amps switch socket combination on the independent board with 1.5 sqmm cable complete as specified and as directed.
All as per item No 61 here-in-before but for switch socket combination 2 in 1,3 pin 5/15 Amp on independent board with single core 2.5 Sqmm PVC unsheathed copper cable and single core 2.5 sqmm copper conductor cable as earth continuity conductor complete all as specified and as directed.
Supply and fixing of modular socket outlet 2 in 1, 5 pin 5 Amp,230 Volts complete all as specified and as directed.
Supply and fixing of modular switch socket combination 2 in 1, 5 pin 5/6 Amps, 240 V including boxes , cover plate etc , complete all as specified and as directed.
Supply and fixing of modular switch socket combination 2 in 1,5/15 Amps, 230 Volts, including boxes , cover plate etc universal complete all as specified and as directed by the Engr-in-Charge.
Supply and fixing of modular Fan regulator upto 100 watt ,230 volt complete all as specified and as directed.
Supply and fixing of Modular White cover plate with frame, 4 module complete all as specified and as directed.
Supply and fixing of Modular White cover plate with frame, 6 module complete all as specified and as directed.
Supply and fixing of Modular White cover plate with frame, 8/12 module complete all as specified and as directed.
Supply and fixing of Modular Metal flush box 4 module complete all as specified and as directed.
Supply and fixing of Modular Metal flush box 6 module complete all as specified and as directed.
Supply and fixing of Modular Metal flush box 12 module complete all as specified and as directed.
Supply and fixing LED Square Light 36 W of size 2 feet x 2 feet lP54, lumen output 100lm/w, 50 Hz, color temp 5700-6500K, CRI>80, THD<10%, PF>0.9, operating voltage 120-300V, surge protection >3KV, lumen 1800, dust free & zero maintenance LED clean room bottom opening luminaire with CRCA powder coating housing, anti glare diffuser with potentiometric integrated energy electronic driver, with all accessories prewired and connecting electrically, after dismenteling of existing light, complete all as specified and as directed. Make: Panasonic Cat Part No. PCRM03368 or equivalent in Crompton /Havells /Bajaj
Supply and fixing ceiling fans, complete with three blade, down rod, accessories 230V, 1200mm sweep, with Squirrel cage induction motor with their all accessories fixed properly on roof surfaces including making hole to fasterning 'S" hook including cutting of roof/ceiling finishing with cement plaster and making good to the distuberd surface of roof internal sides and two coats of distemper to match with the existing colour including connecting/testing complete all as specified and as directed. (Make : Crompton Greaves/Havells/Bajaj).
Supply and fixing sub-main wiring (concealed type) for main DB's to sub DB's with PVC (FR-LSH) insulated & unsheathed two runs of 6 sq mm single core multi stranded copper conductor cable, 1100 Volt grade alongwith one run of 6 sq mm PVC FR-LSH insulated & unsheathed copper conductor cable, 1100 Volt grade, connected to common earth dolly as earth continuity conductor, drawn through and including PVC rigid conduit with all accesseries carefully complete all as specified and as directed by the Engr-in-Charge. Make :- Anchor/Havells/Polycab. Note : Three runs of 6 sqmm cable and one run of PVC Conduit shall constitute one unit.
Supply and fixing sub-main wiring (concealed) for main DB's to sub DB's with PVC (FR-LSH) insulated & unsheathed two runs of 4 sq mm single core multi stranded copper conductor cable, 1100 Volt grade alongwith one run of 4 sq mm PVC FR-LSH insulated & unsheathed copper conductor cable, 1100 Volt grade, connected to common earth dolly as earth continuity conductor, drawn through and including PVC rigid conduit with all accesseries carefullycomplete all as specified and as directed by the Engr-in-Charge. Make :- Anchor/Havells/Polycab. Note : Three runs of 4 sqmm cable and one run of PVC Conduit shall constitute one unit.
Supply and fixing of MCB DB SPN (double door) 8 Ways including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall complete all as specified and as directed by the Engr-in-Charge. (Make :- Havells /Legrand /L&T.)
Supply and fixing of MCB DB SPN (double door) 12 Ways including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall complete all as specified and as directed by the Engr-in-Charge. (Make :- Havells /Legrand /L&T).
Supply and fixing standard size of Down Rod 60 cm with suitable arrangment for cealing fan hanging to hook complete all as specified and as directed.
KAMAKHYA TRADERS
M/S AVIJEET INTERNATIONAL
SINHA ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .