| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹64.8 LAccepted-AOC | ₹64.8 L | L1 | Accepted-AOC L1 |
| 2 | L2₹67.6 LRejected-Finance PLOT NO 74 INDUSTRIAL AREA PHASE 1 CHANDIGARH | NA | NA | 160001 | ₹67.6 L | L2 | Rejected-Finance L2 |
| 3 | L3₹71.0 LRejected-Finance | ₹71.0 L | L3 | Rejected-Finance L3 |
| 4 | L4₹91.5 LRejected-Finance 12 BHARTI AARTIST COLONY VIKAS MARG NEW DELHI 110092 | EAST | DELHI | 110092 | ₹91.5 L | L4 | Rejected-Finance L4 |
| 5 | L5₹98.0 LRejected-Finance | ₹98.0 L | L5 | Rejected-Finance L5 |
Updated dates
Tender Value
₹76.4 L
EMD Value
₹1.5 L
Closing Date
3 Mar 2026, 12:00 pmClosed
Er. Dinesh Tandon
Executive Engineer, Electrical Division No. 2, 1st Floor Additional Deluxe Building Sector- 9/D, Chandigarh.
As per NIT
2026_CHD_90301_1
E2/25/182
Open Tender
Electrical Works
90 days
Chandigarh
As per NIT
3 documents required · 3 mandatory
₹0
₹1.5 L
Chandigarh
8 Jun 2026
29 Jan 2026
3 Mar 2026
29 Jan 2026
3 Mar 2026
3 Feb 2026
3 Feb 2026
Supply, installation, testing and commissioning of 11KV Outdoor Package Sub-Station consisting of 11/0.433 KV 3 phase, 50Hz, Dyn 11 vector group, Copper wound 800 KVA Oil type transformer, HT Switchgear (11kV 400 Amps 21KA for 3 sec. VCB), Low voltage switchgear, factory built ready for connection type with internal G.I earthing complete in all aspects. The CSS shall be fully internal arc tested for 20 KA/1 Sec IAC-A&B as per IEC62271-202. (Please refer DNIT for complete specification of item no.1)
DSR item No.2.22 Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enamelled white on both sides, and with inscription in single red colour on front side as required.
DSR 5.6 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
DSR item No.5.14 Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
DSR item No.23.4 Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:
DSR item No.15.16 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
120 mm dia (OD-120 mm & ID-103 mm nominal)
Labour charges for horizontal boring 1 Mtr. Below ground level for laying of DWC pipe including cost of 2 Nos. pit digging and refilling complete in all respects to entire satisfaction of the Engineer in Charge of the work.
S/E of 4 nos. sand buckets of 10 ltr. Capacity each made out of 24 Gauge G.I sheet. The buckets with sand shall be hanged on Suitable size of angle iron stand fabricated out of 1 ¼ x 1 ¼ x1/8” angle iron having hooks for hanging the buckets in two rows. The job includes the cost of painting with two coats of red paint of superior quality after one coat of primer on buckets and stands to complete the job up to the entire satisfaction of the Engineer–in–charge.
Supply of Erection of medium size first aid box made of 16 gauge MS sheet of size 14”x7”x5” with 6 wound dressings, 3 burn dressings, 13 gms absorbent cotton wool, one dressing scissors, one bottle of spirit of sal volatile, 1 tube of burn ointment (Burnol) tablets of aspiring, 1 No. artificial respirator.
Supply and Erection of Fire Extinguishers ISI marked duly erected/ hung on wall with hooks including the cost of hooks with all material & labour required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of work. Make: Atasee/Safex/Ceasefire/SafePro only.
CO2 type of 9 Kg capacity fire extinguishers conforming to IS.
Supply and erection of CT/PT operated tri-vector meter of accuracy class 0.5 suitable for voltage rating 11 KV/110 Volt, current rating 100/5Amp, or as decided by DISCOM for energy measurement and maximum demand etc. as per the specification of Chandigarh Electrical Department (CED). The three phase HTCT meter should be of Lauritz Knudsen / Secure / Genus make only. The meter is to be got tested from the M&P Sub Division laboratory of the CED at the stake of contractor. The meter is to be installed in the existing metering compartment of the CT&PT unit on a wooden plank (on S/E basis) of suitable size including. The job also includes the cost of supply erection of 11 KV test terminal block for connecting secondary connection of 11KV CT/PT unit &Trivector meter as per site requirement. The job includes labour, taxes and duties etc.
Supply, Fabrication and Erection of cubical type dust and vermin proof metering panel, free standing floor mounting, made out of 14 Gauge M.S. sheet with channel for base frame to accommodate 100/5A (As decided by DISCOM) ratio of CT & PT dry type unit and set of Trivector Meter including fixing of MS angle /flat where ever required.(Please refer DNIT for complete specification of item no.12)
Supply and erection of HT XLPE insulated armoured power cable stranded aluminum conductor sheathed with extruded semi-conducting compound cross linked polyethylene insulated laid up inner sheathed of extruded PVC single layer of galvanized steel flat strip armoured and PVC sheathed over all suitable for 11 KV (earthed) cable to IS: 7098 (Part-ii) 2011 with up to date amendments and laying in the existing cable trey/ RCC pipe cable duct. The XLPE cable shall be of Polycab / Havells / KEI / RR Kabel make only.
Size 50 sq. mm 3 Core (in pipe).
CIVIL WORK FOUNDATION FOR PACKAGE SUBSTATION [Note: - The foundation shall be 800mm(min.) below the ground level and 910mm(min.) above the ground level and having provision for cable trench, grouting of PSS etc and projected at least 500mm(min.) from the size of enclosure all around with provision of steps as required. The top of the plinth has to be properly levelled for proper alignment of the PSS doors. Further internal earthing will brought out on the earthing point on the PSS. The foundation shall be made as per the detailed design submitted by the OEM of the PSS for structural strength and proper installation of the PSS.]
DSR item No 4.1 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering–All work up to plinth level.1:2:4 (1 cement: 2 coarse sand (zone-III) derived from natural sources: 4 graded stone aggregate 20 mm nominal size derived from natural sources)
DSR 5.22 (Civil)Steel Reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete up to plinth level.Thermo-mechanically treated bars of grade Fe-500D or more.
DSR 2.6 (Civil) Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30cm in depth 1.5m in width as well as 10sqmm (on plan) including disposal of excavated earth, lead up to 50m and lift up to 1.5m disposal earth to be leveled and neatly dressed.
All kind of soil
DSR 5.1 (Civil) Providing and laying in position specified grade of reinforced cement concret, excluding the cost of centering, shuttering, finishing and reinforcement- All work upto plinth level:
1:2:4 (1 cement: 2 coarse sand (zone-III) derived from natural sources: 4 graded stone aggregate 20 mm nominal size derived from natural sources)
DSR item No. 13.2 (Civil) 15 mm plaster on the rough side of single or half brick wall of mix:
1:4 (1 cement: 4 fine sand)
DSR Item No. 5.9.1 (Civil) Centering and shuttering including strutting, propping etc. and removal of form for :
Foundations, footings, basis of columns, etc. for mass concrete.
DSR item No.2.27 (Civil) Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Supply, installation, testing & commissioning of 3 phase, 50Hz, 11KV, 800 Amp, 26.3KA/3Sec. incoming VCB panel with copper busbar for indoor substations. The VCB should be floor mounted trolley type horizontal isolation, horizontal draw out, type Breaker confirming to IEC-62271-100 & Panel as per IEC-6227I-200, & IEC-60694 as amended up to date. The panel shall be compartmentalized consisting of Bus bars compartment, Breaker compartment, Cable and CT compartment, LV compartment for Relays, indications and controls. Each compartment shall be segregated from other by metallic partition. The shutters shall also be metallic for safety of operation staff. Each of the VCB, Bus bar and Cable compartment shall have separate pressure relief device at top to exhaust arc energy in case of an arc in panel.(Please refer DNIT for complete specification of item no.20)
Supply, installation, testing & commissioning of 3 Phase, 50Hz, 11KV, 800 Amp, 26.3KA/3Sec. outgoing VCB panel with copper busbar for indoor sub stations. The VCB should be floor mounted trolley type horizontal isolation, horizontal draw out, type Breaker as per IEC-62271-100 & Panel as per IEC- 6227I-200, as amended up to date. The panel shall be compartmentalized consisting of Bus bars compartment, Breaker compartment, Cable and CT compartment, LV compartment for Relays, indications and controls. Each compartment shall be segregated from other by metallic partition. The shutters shall also be metallic for safety of operation staff.(Please refer DNIT for complete specification of item no.21)
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 32.07 MB
BOQ_110443.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid