Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Not Admitted-Finance | Not Admitted-Finance Others-Does not fulfill NIT Condition |
| 4 | Not Admitted-Finance | Not Admitted-Finance Others-Does not fulfill NIT condition |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
8 Jun 2023, 11:15 amClosed
EE ENM M6
DELHI JAL BOARD MU BLOCK PITAMPUR DELHI-110034
Repair Renovation of delivery line and other allied E and M works at 1040 Shivaji Enclave BPS in AC 26
2023_DJB_242160_2
NIT NO. 3(M-6)
Open Tender
Miscellaneous Works
Item Rate
30 days
EE ENM M6
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Account No 50448339804
₹20,000
Yes
15 Jun 2023
1 Jun 2023
8 Jun 2023
1 Jun 2023
8 Jun 2023
1 Jun 2023
Repair/Renovation of 40 HP pump sets foundation at 1040 Shivaji Enclave BPS by carrying following works:-Dismantling of p/set i.e. pump and motor from foundation by disconnecting electric connection, removing of coupling etc. by cutting of rusted nut & bolts with the help of gas cutter and manual labour etc. as required.
Removing the existing damaged M.S. base frame from the foundation by cutting of nut & bolts with the help of gas cutter and man power etc. as required and old material shifted to the store as per direction of site incharge.
Breaking of C.C.foundation with the help of pneumatic hammer i/c manual & heavy labour taking out the existing damaged foundation bolt etc.
Making of new C.C. foundation with suitable ratio of gravels, sand and cement as per standard size suitable for above p/set i/c complete finishing etc. as required.
Providing of MS base frame 1.5 mtrX0.5 mtr made out of heavy duty ISMC as per site requirement.
Supply and fixing of M.S. coupling guards suitable for above p/set. Jali includes drilling holes in M.S. base frame & fixing the same with the help of necessary nut bolts & washers etc. as required at site.
Fitting of M.S. base frame on C.C. foundation after proper alignment/level, Fitting of p/set on the base frame with the help of necessary material as required.
Installation of above 40HP motor on the MS base frame job i/c coupled pump and motor with proper alignment, taking all safety precautions arranging all tools & tackles etc. and connection the motor from panel to starter.
Renovation of Delivery line of size 150 mm by carrying following works:-Dismantling of 150 mm dia sluice valve and NRV from existing system with the help of gas cutter for cutting of nut & bolt and taken out from existing line with the help of heavy labour and old material shifted to the store as per direction of site incharge.
Supply of M.S. black pipe 150mm dia C class heavy duty. Make: Jindal/TATA
Supply of 150mm dia flange thickness size 12mm as per site requirement.
Supply of CI,double flanged spindle sluice valve PN 1.0 IS 14846 CI body/wedge/bronze ring/SS 410 shaft construction and SS IS 6603 Gr 12,Cr12 of 150mm size Make:-Kirloskar/IVC/DJB approved make.
Supply of CI swing type non return valve as per IS 5312 PN 1.0 CI body ,door/bronze to rubber rings/SS 410 hinge pin of 150 mm size.Make:-Kirloskar/IVC/DJB approved make.
S/o different size of nut & bolts of good quality.
S/o rubber insertion jointing sheet conforming IS 638/79 with ISI mark 3 mm thick Make:- Jyoti or any other make approved by DJB
Making the complete line with the above material with the help of cutting, welding and grinding etc. as per site requirement.
Painting the above job with two coats of anti-corrosive paint after fittings all valves, bends etc in original position with complete civil works and testing/commissioning on full load i/c cartage etc.
Renovation of LT panel by carrying following works:-Dismantling of all damaged switchgears, measurement instrument, indicating lights, cleaning of dust, spider web, foreign particles etc. and removing of complete wiring and connection at site.
S/o MCCB (Adjustable thermal & Fixed magnetic) four pole 415 V,50 Hz breaking capacity 36 KA of size 250 Amp. Make:- Havells/Standard/C&S/L&T
S/o MCCB (Adjustable thermal & Fixed magnetic) four pole 415 V,50 Hz breaking capacity 36 KA of size 100 Amp. Make:- Havells/Standard/C&S/L&T
S/o changeover switch four pole 415V,50 Hz of size 200 Amp. Make:- Havells/Standard/C&S/L&T
S/o manually operated oil immersed sheet steel clad wall mounting star delta starter complete with contact and necessary protection of suitable for50 HP capacity heavy duty single contact and over load coil. Make:- Advance/MEI/Capital
Transformer Oil. Make:- Savita/Power
S/o single core copper conductor PVC insulated,1100 volts of size 70 sq.mm.Make:-Gloster/Havells/Grandlay/Universal/CCI/ICL/ICC
S/o copper tube terminal heavy duty thimbles of size 70 sq.mm. Make:-Dowells/DJB approved
Providing of bus bar lengths in aluminium construction of suitable cross section as complete panel duly sleeved with heat shrinkable PVC sleeve, support insulator of bus bar as per site requirement and fixing of new bus bar lengths for making the joints of the incoming and outgoing cable connection, supply arrangement including bending/cutting/ shaping of the bus bars as required. The job includes providing of nut bolts, insulators and other consumable as per site requirement.
S/o LED street light 60W, pressure die cast aluminum housing with heat resistant, toughened glass and IP66 protection. Make:-CG/Havells/Bajaj
S/o ceiling fan 240 V 1200 mm sweep size. Make:-Crompton/Havells/Orient
Fitting of the above components in panel with terminal blocks, channels, ferrules, thimble, support insulator on bus bar, required hardwares and painting of complete panel board as required at site.
Raj Engineering Co.
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .