Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC | ₹1.2 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹1.6 CrRejected-Finance A 3 257 JANAKPURI NEW DELHI 110058 | WEST DELHI | DELHI | 110058 | ₹1.6 Cr | L2 | Rejected-Finance Being other than L1 |
| 3 | L3₹1.8 CrRejected-Finance 23 A MORAR ENCLAVE GOLA KA MANDIR MORAR GWALIOR MP 474005 | GWALIOR | GWALIOR | MP | 474005 | ₹1.8 Cr | L3 | Rejected-Finance Being other than L1 |
| 4 | L4₹1.9 CrRejected-Finance 12 BHARTI AARTIST COLONY VIKAS MARG NEW DELHI 110092 | EAST | DELHI | 110092 | ₹1.9 Cr | L4 | Rejected-Finance Being other than L1 |
| 5 | L5₹2.2 CrRejected-Finance 84 A VIJAY NAGAR COLONY LALGHATI PO NAYAPURA BHOPAL 462032 | 462032 | ₹2.2 Cr | L5 | Rejected-Finance Being other than L1 |
| Sl No | Description | Qty | Unit | M/S Rajeev Construction L3 | Vijaypower Generators Limited L4 | POONAM ELECTRIC INDUSTRY L5 | Maa Durga Electricals L1 | M/S ADHIKARI CONSTRUCTION CO. L2 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply, installation, commissioning and testing of 100 KVA, 11/0.433 KV, 3 phase, 50 Hz, ONAN cooled oil immersed Copper wound outdoor type step down transformer, Level III type confirming to IS 2026 complete with first filling of IS: 335 ISI Marked filtered & dehydrated transformer oil and other standard fittings/ accessories and 7 position off circuit tap changer (tapping range +7.5% in steps of 2.5% each) with vector Group dyn-11. It shall be oil immersed, naturally cooled, copper wound, winding core type MS radiator cooled tank with first fill of transformer oil plus spare oil (five percentage) capacity) as per IS 335 of 1980 with cooling system. The temperature of oil shall not be raised more than 50 degree centigrade to ambient temp and 55 degree centigrade of winding. Transformer shall be painted with two coat of epoxy paint as per IS- 632.
The Transformer shall be provided with the following: -
(a) Rating and diagram (terminal marking) plate
(b) Two earthing terminals for body earthing and two for neutral earthing
(c) Cover lifting eye and transformer lifting lugs.
(d) Thermometer pocket
(e) Air release hole with plug
(f) Tap changer with locking provision
(g) Plain withdrawal type oil level gauge
(h) Dehydrating breathing device which could not permit ingress of rain water and insects.
(j) Filter valve with threaded adaptor at top & bottom
(k) Oil conservator with filling hole and cap, drain valve magnetic oil level gauge oil level indicator.
(l) Silica gel breather with connecting pipe with fill of dehydrating agent and oil seal | 1 | Each | 7,70,000 ₹7.7 L | 7,17,000 ₹7.2 L | 8,10,000 ₹8.1 L | 4,50,000 ₹4.5 L | 5,99,999 ₹6.0 L |
| 1.01Contd..../- (m) Shut off valve between conservator tank and main tank. (n) Explosion relief vent mounted on tank with double diaphragm and equaliser pipe conservator of space (Pressure release valve) (o) Hand hole of sufficient size for access to the interior of tank. (p) Inspection Cover (q) Jockey pads (r) Skids. (s) Extra busing for neutral on LV side (t) Clamping device for clamping the transformer with foundation channel. (u) HV bushing with arcing horn on HV side. (v) Cable end box on secondary side LV side. (w) Winding temperature indication with alarm and trip contacts. | ||||||||
| 2.00 | Supply, installation, commissioning and testing of 100 KVA, 11/0.433 KV, 3 phase, 50 Hz, ONAN cooled oil immersed Copper wound indoor type step down transformer, Level III type confirming to IS 2026 complete with first filling of IS: 335 ISI Marked filtered & dehydrated transformer oil and other standard fittings/ accessories and 7 position off circuit tap changer (tapping range +7.5% in steps of 2.5% each) with vector Group dyn-11. It shall be oil immersed, naturally cooled, copper wound, winding core type MS radiator cooled tank with first fill of transformer oil plus spare oil (five percentage) capacity) as per IS 335 of 1980 with cooling system. The temperature of oil shall not be raised more than 50 degree centigrade to ambient temp and 55 degree centigrade of winding. Transformer shall be painted with two coat of epoxy paint as per IS- 632.
The Transformer shall be provided with the following: -
(a) Rating and diagram (terminal marking) plate
(b) Two earthing terminals for body earthing and two for neutral earthing
(c) Cover lifting eye and transformer lifting lugs.
(d) Thermometer pocket
(e) Air release hole with plug
(f) Tap changer with locking provision
(g) Plain withdrawal type oil level gauge
(h) Dehydrating breathing device which could not permit ingress of rain water and insects.
(j) Filter valve with threaded adaptor at top & bottom
(k) Oil conservator with filling hole and cap, drain valve magnetic oil level gauge oil level indicator.
(l) Silica gel breather with connecting pipe with fill of dehydrating agent and oil seal | 2 | Each | 7,70,000 ₹15.4 L | 7,17,000 ₹14.3 L | 8,10,000 ₹16.2 L | 4,65,000 ₹9.3 L | 5,99,999 ₹12.0 L |
| 2.01Contd..../- (m) Shut off valve between conservator tank and main tank. (n) Explosion relief vent mounted on tank with double diaphragm and equaliser pipe conservator of space (Pressure release valve) (o) Hand hole of sufficient size for access to the interior of tank. (p) Inspection Cover (q) Jockey pads (r) Skids. (s) Extra busing for neutral on LV side (t) Clamping device for clamping the transformer with foundation channel. (u) HV bushing with arcing horn on HV side. (v) Cable end box on secondary side LV side. (w) Winding temperature indication with alarm and trip contacts. | ||||||||
| 3.00 | Supply, installation, commissioning and testing of 160 KVA, 11/0.433 KV, 3 phase, 50 Hz, ONAN cooled oil immersed Copper wound outdoor type step down transformer, Level III type confirming to IS 2026 complete with first filling of IS: 335 ISI Marked filtered & dehydrated transformer oil and other standard fittings/ accessories and 7 position off circuit tap changer (tapping range +7.5% in steps of 2.5% each) with vector Group dyn-11. It shall be oil immersed, naturally cooled, copper wound, winding core type MS radiator cooled tank with first fill of transformer oil plus spare oil (five percentage) capacity) as per IS 335 of 1980 with cooling system. The temperature of oil shall not be raised more than 50 degree centigrade to ambient temp and 55 degree centigrade of winding. Transformer shall be painted with two coat of epoxy paint as per IS- 632.
The Transformer shall be provided with the following: -
(a) Rating and diagram (terminal marking) plate
(b) Two earthing terminals for body earthing and two for neutral earthing
(c) Cover lifting eye and transformer lifting lugs.
(d) Thermometer pocket
(e) Air release hole with plug
(f) Tap changer with locking provision
(g) Plain withdrawal type oil level gauge
(h) Dehydrating breathing device which could not permit ingress of rain water and insects.
(j) Filter valve with threaded adaptor at top & bottom
(k) Oil conservator with filling hole and cap, drain valve magnetic oil level gauge oil level indicator.
(l) Silica gel breather with connecting pipe with fill of dehydrating agent and oil seal | 1 | Each | 9,10,000 ₹9.1 L | 8,50,002 ₹8.5 L | 13,50,000 ₹13.5 L | 4,85,000 ₹4.8 L | 7,99,999 ₹8.0 L |
| 3.01Contd..../- (m) Shut off valve between conservator tank and main tank. (n) Explosion relief vent mounted on tank with double diaphragm and equaliser pipe conservator of space (Pressure release valve) (o) Hand hole of sufficient size for access to the interior of tank. (p) Inspection Cover (q) Jockey pads (r) Skids. (s) Extra busing for neutral on LV side (t) Clamping device for clamping the transformer with foundation channel. (u) HV bushing with arcing horn on HV side. (v) Cable end box on secondary side LV side. (w) Winding temperature indication with alarm and trip contacts. | ||||||||
| 4.00 | Supply, installation, commissioning and testing of 160 KVA, 11/0.433 KV, 3 phase, 50 Hz, ONAN cooled oil immersed Copper wound indoor type step down transformer, Level III type confirming to IS 2026 complete with first filling of IS: 335 ISI Marked filtered & dehydrated transformer oil and other standard fittings/ accessories and 7 position off circuit tap changer (tapping range +7.5% in steps of 2.5% each) with vector Group dyn-11. It shall be oil immersed, naturally cooled, copper wound, winding core type MS radiator cooled tank with first fill of transformer oil plus spare oil (five percentage) capacity) as per IS 335 of 1980 with cooling system. The temperature of oil shall not be raised more than 50 degree centigrade to ambient temp and 55 degree centigrade of winding. Transformer shall be painted with two coat of epoxy paint as per IS- 632.
The Transformer shall be provided with the following: -
(a) Rating and diagram (terminal marking) plate
(b) Two earthing terminals for body earthing and two for neutral earthing
(c) Cover lifting eye and transformer lifting lugs.
(d) Thermometer pocket
(e) Air release hole with plug
(f) Tap changer with locking provision
(g) Plain withdrawal type oil level gauge
(h) Dehydrating breathing device which could not permit ingress of rain water and insects.
(j) Filter valve with threaded adaptor at top & bottom
(k) Oil conservator with filling hole and cap, drain valve magnetic oil level gauge oil level indicator.
(l) Silica gel breather with connecting pipe with fill of dehydrating agent and oil seal | 1 | Each | 9,10,000 ₹9.1 L | 8,50,002 ₹8.5 L | 13,50,000 ₹13.5 L | 5,25,000 ₹5.3 L | 7,99,999 ₹8.0 L |
| 4.01Contd..../- (m) Shut off valve between conservator tank and main tank. (n) Explosion relief vent mounted on tank with double diaphragm and equaliser pipe conservator of space (Pressure release valve) (o) Hand hole of sufficient size for access to the interior of tank. (p) Inspection Cover (q) Jockey pads (r) Skids. (s) Extra busing for neutral on LV side (t) Clamping device for clamping the transformer with foundation channel. (u) HV bushing with arcing horn on HV side. (v) Cable end box on secondary side LV side. (w) Winding temperature indication with alarm and trip contacts. | ||||||||
| 5.00 | Supply, installation, commissioning and testing of 200 KVA, 11/0.433 KV, 3 phase, 50 Hz, ONAN cooled oil immersed Copper wound outdoor type step down transformer, Level III type confirming to IS 2026 complete with first filling of IS: 335 ISI Marked filtered & dehydrated transformer oil and other standard fittings/ accessories and 7 position off circuit tap changer (tapping range +7.5% in steps of 2.5% each) with vector Group dyn-11. It shall be oil immersed, naturally cooled, copper wound, winding core type MS radiator cooled tank with first fill of transformer oil plus spare oil (five percentage) capacity) as per IS 335 of 1980 with cooling system. The temperature of oil shall not be raised more than 50 degree centigrade to ambient temp and 55 degree centigrade of winding. Transformer shall be painted with two coat of epoxy paint as per IS- 632.
The Transformer shall be provided with the following: -
(a) Rating and diagram (terminal marking) plate
(b) Two earthing terminals for body earthing and two for neutral earthing
(c) Cover lifting eye and transformer lifting lugs.
(d) Thermometer pocket
(e) Air release hole with plug
(f) Tap changer with locking provision
(g) Plain withdrawal type oil level gauge
(h) Dehydrating breathing device which could not permit ingress of rain water and insects.
(j) Filter valve with threaded adaptor at top & bottom
(k) Oil conservator with filling hole and cap, drain valve magnetic oil level gauge oil level indicator.
(l) Silica gel breather with connecting pipe with fill of dehydrating agent and oil seal | 2 | Each | 10,75,000 ₹21.5 L | 9,86,001 ₹19.7 L | 14,40,000 ₹28.8 L | 7,50,000 ₹15 L | 9,99,999 ₹20.0 L |
| 5.01Contd..../- (m) Shut off valve between conservator tank and main tank. (n) Explosion relief vent mounted on tank with double diaphragm and equaliser pipe conservator of space (Pressure release valve) (o) Hand hole of sufficient size for access to the interior of tank. (p) Inspection Cover (q) Jockey pads (r) Skids. (s) Extra busing for neutral on LV side (t) Clamping device for clamping the transformer with foundation channel. (u) HV bushing with arcing horn on HV side. (v) Cable end box on secondary side LV side. (w) Winding temperature indication with alarm and trip contacts. | ||||||||
Updated dates
Tender Value
₹1.3 Cr
EMD Value
₹2.1 L
Closing Date
25 Dec 2025, 6:00 pmClosed
CWE AF Gwalior
HQ CWE AF Gwalior 474020
SPECIAL REPAIR FOR REPLACEMENT FOR TRANSFORMER AGINEST BER AT AF STN GWALIOR.
2025_MES_738938_1
86041
Open Tender
Electrical and Maintenance Works
270 days
GE AF Adm Area
As per tender document
9 documents required · 9 mandatory
₹1,000
GE AF ADM Area
₹2.1 L
Yes
5 Feb 2026
8 Nov 2025
1 Jan 2026
8 Nov 2025
25 Dec 2025
8 Dec 2025
Amount
Supply, installation, commissioning and testing of 100 KVA, 11/0.433 KV, 3 phase, 50 Hz, ONAN cooled oil immersed Copper wound outdoor type step down transformer, Level III type confirming to IS 2026 complete with first filling of IS: 335 ISI Marked filtered & dehydrated transformer oil and other standard fittings/ accessories and 7 position off circuit tap changer (tapping range +7.5% in steps of 2.5% each) with vector Group dyn-11. It shall be oil immersed, naturally cooled, copper wound, winding core type MS radiator cooled tank with first fill of transformer oil plus spare oil (five percentage) capacity) as per IS 335 of 1980 with cooling system. The temperature of oil shall not be raised more than 50 degree centigrade to ambient temp and 55 degree centigrade of winding. Transformer shall be painted with two coat of epoxy paint as per IS- 632. The Transformer shall be provided with the following: - (a) Rating and diagram (terminal marking) plate (b) Two earthing terminals for body earthing and two for neutral earthing (c) Cover lifting eye and transformer lifting lugs. (d) Thermometer pocket (e) Air release hole with plug (f) Tap changer with locking provision (g) Plain withdrawal type oil level gauge (h) Dehydrating breathing device which could not permit ingress of rain water and insects. (j) Filter valve with threaded adaptor at top & bottom (k) Oil conservator with filling hole and cap, drain valve magnetic oil level gauge oil level indicator. (l) Silica gel breather with connecting pipe with fill of dehydrating agent and oil seal
Contd..../- (m) Shut off valve between conservator tank and main tank. (n) Explosion relief vent mounted on tank with double diaphragm and equaliser pipe conservator of space (Pressure release valve) (o) Hand hole of sufficient size for access to the interior of tank. (p) Inspection Cover (q) Jockey pads (r) Skids. (s) Extra busing for neutral on LV side (t) Clamping device for clamping the transformer with foundation channel. (u) HV bushing with arcing horn on HV side. (v) Cable end box on secondary side LV side. (w) Winding temperature indication with alarm and trip contacts.
Supply, installation, commissioning and testing of 100 KVA, 11/0.433 KV, 3 phase, 50 Hz, ONAN cooled oil immersed Copper wound indoor type step down transformer, Level III type confirming to IS 2026 complete with first filling of IS: 335 ISI Marked filtered & dehydrated transformer oil and other standard fittings/ accessories and 7 position off circuit tap changer (tapping range +7.5% in steps of 2.5% each) with vector Group dyn-11. It shall be oil immersed, naturally cooled, copper wound, winding core type MS radiator cooled tank with first fill of transformer oil plus spare oil (five percentage) capacity) as per IS 335 of 1980 with cooling system. The temperature of oil shall not be raised more than 50 degree centigrade to ambient temp and 55 degree centigrade of winding. Transformer shall be painted with two coat of epoxy paint as per IS- 632. The Transformer shall be provided with the following: - (a) Rating and diagram (terminal marking) plate (b) Two earthing terminals for body earthing and two for neutral earthing (c) Cover lifting eye and transformer lifting lugs. (d) Thermometer pocket (e) Air release hole with plug (f) Tap changer with locking provision (g) Plain withdrawal type oil level gauge (h) Dehydrating breathing device which could not permit ingress of rain water and insects. (j) Filter valve with threaded adaptor at top & bottom (k) Oil conservator with filling hole and cap, drain valve magnetic oil level gauge oil level indicator. (l) Silica gel breather with connecting pipe with fill of dehydrating agent and oil seal
Contd..../- (m) Shut off valve between conservator tank and main tank. (n) Explosion relief vent mounted on tank with double diaphragm and equaliser pipe conservator of space (Pressure release valve) (o) Hand hole of sufficient size for access to the interior of tank. (p) Inspection Cover (q) Jockey pads (r) Skids. (s) Extra busing for neutral on LV side (t) Clamping device for clamping the transformer with foundation channel. (u) HV bushing with arcing horn on HV side. (v) Cable end box on secondary side LV side. (w) Winding temperature indication with alarm and trip contacts.
Supply, installation, commissioning and testing of 160 KVA, 11/0.433 KV, 3 phase, 50 Hz, ONAN cooled oil immersed Copper wound outdoor type step down transformer, Level III type confirming to IS 2026 complete with first filling of IS: 335 ISI Marked filtered & dehydrated transformer oil and other standard fittings/ accessories and 7 position off circuit tap changer (tapping range +7.5% in steps of 2.5% each) with vector Group dyn-11. It shall be oil immersed, naturally cooled, copper wound, winding core type MS radiator cooled tank with first fill of transformer oil plus spare oil (five percentage) capacity) as per IS 335 of 1980 with cooling system. The temperature of oil shall not be raised more than 50 degree centigrade to ambient temp and 55 degree centigrade of winding. Transformer shall be painted with two coat of epoxy paint as per IS- 632. The Transformer shall be provided with the following: - (a) Rating and diagram (terminal marking) plate (b) Two earthing terminals for body earthing and two for neutral earthing (c) Cover lifting eye and transformer lifting lugs. (d) Thermometer pocket (e) Air release hole with plug (f) Tap changer with locking provision (g) Plain withdrawal type oil level gauge (h) Dehydrating breathing device which could not permit ingress of rain water and insects. (j) Filter valve with threaded adaptor at top & bottom (k) Oil conservator with filling hole and cap, drain valve magnetic oil level gauge oil level indicator. (l) Silica gel breather with connecting pipe with fill of dehydrating agent and oil seal
Contd..../- (m) Shut off valve between conservator tank and main tank. (n) Explosion relief vent mounted on tank with double diaphragm and equaliser pipe conservator of space (Pressure release valve) (o) Hand hole of sufficient size for access to the interior of tank. (p) Inspection Cover (q) Jockey pads (r) Skids. (s) Extra busing for neutral on LV side (t) Clamping device for clamping the transformer with foundation channel. (u) HV bushing with arcing horn on HV side. (v) Cable end box on secondary side LV side. (w) Winding temperature indication with alarm and trip contacts.
Supply, installation, commissioning and testing of 160 KVA, 11/0.433 KV, 3 phase, 50 Hz, ONAN cooled oil immersed Copper wound indoor type step down transformer, Level III type confirming to IS 2026 complete with first filling of IS: 335 ISI Marked filtered & dehydrated transformer oil and other standard fittings/ accessories and 7 position off circuit tap changer (tapping range +7.5% in steps of 2.5% each) with vector Group dyn-11. It shall be oil immersed, naturally cooled, copper wound, winding core type MS radiator cooled tank with first fill of transformer oil plus spare oil (five percentage) capacity) as per IS 335 of 1980 with cooling system. The temperature of oil shall not be raised more than 50 degree centigrade to ambient temp and 55 degree centigrade of winding. Transformer shall be painted with two coat of epoxy paint as per IS- 632. The Transformer shall be provided with the following: - (a) Rating and diagram (terminal marking) plate (b) Two earthing terminals for body earthing and two for neutral earthing (c) Cover lifting eye and transformer lifting lugs. (d) Thermometer pocket (e) Air release hole with plug (f) Tap changer with locking provision (g) Plain withdrawal type oil level gauge (h) Dehydrating breathing device which could not permit ingress of rain water and insects. (j) Filter valve with threaded adaptor at top & bottom (k) Oil conservator with filling hole and cap, drain valve magnetic oil level gauge oil level indicator. (l) Silica gel breather with connecting pipe with fill of dehydrating agent and oil seal
Contd..../- (m) Shut off valve between conservator tank and main tank. (n) Explosion relief vent mounted on tank with double diaphragm and equaliser pipe conservator of space (Pressure release valve) (o) Hand hole of sufficient size for access to the interior of tank. (p) Inspection Cover (q) Jockey pads (r) Skids. (s) Extra busing for neutral on LV side (t) Clamping device for clamping the transformer with foundation channel. (u) HV bushing with arcing horn on HV side. (v) Cable end box on secondary side LV side. (w) Winding temperature indication with alarm and trip contacts.
Supply, installation, commissioning and testing of 200 KVA, 11/0.433 KV, 3 phase, 50 Hz, ONAN cooled oil immersed Copper wound outdoor type step down transformer, Level III type confirming to IS 2026 complete with first filling of IS: 335 ISI Marked filtered & dehydrated transformer oil and other standard fittings/ accessories and 7 position off circuit tap changer (tapping range +7.5% in steps of 2.5% each) with vector Group dyn-11. It shall be oil immersed, naturally cooled, copper wound, winding core type MS radiator cooled tank with first fill of transformer oil plus spare oil (five percentage) capacity) as per IS 335 of 1980 with cooling system. The temperature of oil shall not be raised more than 50 degree centigrade to ambient temp and 55 degree centigrade of winding. Transformer shall be painted with two coat of epoxy paint as per IS- 632. The Transformer shall be provided with the following: - (a) Rating and diagram (terminal marking) plate (b) Two earthing terminals for body earthing and two for neutral earthing (c) Cover lifting eye and transformer lifting lugs. (d) Thermometer pocket (e) Air release hole with plug (f) Tap changer with locking provision (g) Plain withdrawal type oil level gauge (h) Dehydrating breathing device which could not permit ingress of rain water and insects. (j) Filter valve with threaded adaptor at top & bottom (k) Oil conservator with filling hole and cap, drain valve magnetic oil level gauge oil level indicator. (l) Silica gel breather with connecting pipe with fill of dehydrating agent and oil seal
Contd..../- (m) Shut off valve between conservator tank and main tank. (n) Explosion relief vent mounted on tank with double diaphragm and equaliser pipe conservator of space (Pressure release valve) (o) Hand hole of sufficient size for access to the interior of tank. (p) Inspection Cover (q) Jockey pads (r) Skids. (s) Extra busing for neutral on LV side (t) Clamping device for clamping the transformer with foundation channel. (u) HV bushing with arcing horn on HV side. (v) Cable end box on secondary side LV side. (w) Winding temperature indication with alarm and trip contacts.
Supply, installation, commissioning and testing of 315 KVA, 11/0.433 KV, 3 phase, 50 Hz, ONAN cooled oil immersed Copper wound outdoor type step down transformer, Level III type confirming to IS 2026 complete with first filling of IS: 335 ISI Marked filtered & dehydrated transformer oil and other standard fittings/ accessories and 7 position off circuit tap changer (tapping range +7.5% in steps of 2.5% each) with vector Group dyn-11. It shall be oil immersed, naturally cooled, copper wound, winding core type MS radiator cooled tank with first fill of transformer oil plus spare oil (five percentage) capacity) as per IS 335 of 1980 with cooling system. The temperature of oil shall not be raised more than 50 degree centigrade to ambient temp and 55 degree centigrade of winding. Transformer shall be painted with two coat of epoxy paint as per IS- 632. The Transformer shall be provided with the following: - (a) Rating and diagram (terminal marking) plate (b) Two earthing terminals for body earthing and two for neutral earthing (c) Cover lifting eye and transformer lifting lugs. (d) Thermometer pocket (e) Air release hole with plug (f) Tap changer with locking provision (g) Plain withdrawal type oil level gauge (h) Dehydrating breathing device which could not permit ingress of rain water and insects. (j) Filter valve with threaded adaptor at top & bottom (k) Oil conservator with filling hole and cap, drain valve magnetic oil level gauge oil level indicator. (l) Silica gel breather with connecting pipe with fill of dehydrating agent and oil seal
Contd..../- (m) Shut off valve between conservator tank and main tank. (n) Explosion relief vent mounted on tank with double diaphragm and equaliser pipe conservator of space (Pressure release valve) (o) Hand hole of sufficient size for access to the interior of tank. (p) Inspection Cover (q) Jockey pads (r) Skids. (s) Extra busing for neutral on LV side (t) Clamping device for clamping the transformer with foundation channel. (u) HV bushing with arcing horn on HV side. (v) Cable end box on secondary side LV side. (w) Winding temperature indication with alarm and trip contacts.
Supply, installation, commissioning and testing of 315 KVA, 11/0.433 KV, 3 phase, 50 Hz, ONAN cooled oil immersed Copper wound indoor type step down transformer, Level III type confirming to IS 2026 complete with first filling of IS: 335 ISI Marked filtered & dehydrated transformer oil and other standard fittings/ accessories and 7 position off circuit tap changer (tapping range +7.5% in steps of 2.5% each) with vector Group dyn-11. It shall be oil immersed, naturally cooled, copper wound, winding core type MS radiator cooled tank with first fill of transformer oil plus spare oil (five percentage) capacity) as per IS 335 of 1980 with cooling system. The temperature of oil shall not be raised more than 50 degree centigrade to ambient temp and 55 degree centigrade of winding. Transformer shall be painted with two coat of epoxy paint as per IS- 632. The Transformer shall be provided with the following: - (a) Rating and diagram (terminal marking) plate (b) Two earthing terminals for body earthing and two for neutral earthing (c) Cover lifting eye and transformer lifting lugs. (d) Thermometer pocket (e) Air release hole with plug (f) Tap changer with locking provision (g) Plain withdrawal type oil level gauge (h) Dehydrating breathing device which could not permit ingress of rain water and insects. (j) Filter valve with threaded adaptor at top & bottom (k) Oil conservator with filling hole and cap, drain valve magnetic oil level gauge oil level indicator. (l) Silica gel breather with connecting pipe with fill of dehydrating agent and oil seal
Contd..../- (m) Shut off valve between conservator tank and main tank. (n) Explosion relief vent mounted on tank with double diaphragm and equaliser pipe conservator of space (Pressure release valve) (o) Hand hole of sufficient size for access to the interior of tank. (p) Inspection Cover (q) Jockey pads (r) Skids. (s) Extra busing for neutral on LV side (t) Clamping device for clamping the transformer with foundation channel. (u) HV bushing with arcing horn on HV side. (v) Cable end box on secondary side LV side. (w) Winding temperature indication with alarm and trip contacts.
Supply, installation, commissioning and testing of 400 KVA, 11/0.433 KV, 3 phase, 50 Hz, ONAN cooled oil immersed Copper wound outdoor type step down transformer, Level III type confirming to IS 2026 complete with first filling of IS: 335 ISI Marked filtered & dehydrated transformer oil and other standard fittings/ accessories and 7 position off circuit tap changer (tapping range +7.5% in steps of 2.5% each) with vector Group dyn-11. It shall be oil immersed, naturally cooled, copper wound, winding core type MS radiator cooled tank with first fill of transformer oil plus spare oil (five percentage) capacity) as per IS 335 of 1980 with cooling system. The temperature of oil shall not be raised more than 50 degree centigrade to ambient temp and 55 degree centigrade of winding. Transformer shall be painted with two coat of epoxy paint as per IS- 632. The Transformer shall be provided with the following: - (a) Rating and diagram (terminal marking) plate (b) Two earthing terminals for body earthing and two for neutral earthing (c) Cover lifting eye and transformer lifting lugs. (d) Thermometer pocket (e) Air release hole with plug (f) Tap changer with locking provision (g) Plain withdrawal type oil level gauge (h) Dehydrating breathing device which could not permit ingress of rain water and insects. (j) Filter valve with threaded adaptor at top & bottom (k) Oil conservator with filling hole and cap, drain valve magnetic oil level gauge oil level indicator. (l) Silica gel breather with connecting pipe with fill of dehydrating agent and oil seal
Contd..../- (m) Shut off valve between conservator tank and main tank. (n) Explosion relief vent mounted on tank with double diaphragm and equaliser pipe conservator of space (Pressure release valve) (o) Hand hole of sufficient size for access to the interior of tank. (p) Inspection Cover (q) Jockey pads (r) Skids. (s) Extra busing for neutral on LV side (t) Clamping device for clamping the transformer with foundation channel. (u) HV bushing with arcing horn on HV side. (v) Cable end box on secondary side LV side. (w) Winding temperature indication with alarm and trip contacts.
Supply, installation, commissioning and testing of 500 KVA, 11/0.433 KV, 3 phase, 50 Hz, Onan cooled oil immersed Copper wound outdoor type step down transformer, Level III type confirming to IS 2026 complete with first filling of IS: 335 ISI Marked filtered & dehydrated transformer oil and other standard fittings / accessories and 7 position off circuit tap changer (tapping range +7.5% in steps of 2.5% each) with vector Group dyn-11. It shall be oil immersed, naturally cooled, copper wound, winding core type MS radiator cooled tank with first fill of transformer oil plus spare oil (five percentage) capacity) as per IS 335 of 1980 with cooling system. The temperature of oil shall not be raised more than 50 degree centigrade to ambient temp and 55 degree centigrade of winding. Transformer shall be painted with two coat of epoxy paint as per IS- 632. The Transformer shall be provided with the following: - (a) Rating and diagram (terminal marking) plate (b) Two earthing terminals for body earthing and two for neutral earthing (c) Cover lifting eye and transformer lifting lugs. (d) Thermometer pocket (e) Air release hole with plug (f) Tap changer with locking provision (g) Plain withdrawal type oil level gauge (h) Dehydrating breathing device which could not permit ingress of rain water and insects. (j) Filter valve with threaded adaptor at top & bottom (k) Oil conservator with filling hole and cap, drain valve magnetic oil level gauge oil level indicator. (l) Silica gel breather with connecting pipe with fill of dehydrating agent and oil seal
Contd..../- (m) Shut off valve between conservator tank and main tank. (n) Explosion relief vent mounted on tank with double diaphragm and equaliser pipe conservator of space (Pressure release valve) (o) Hand hole of sufficient size for access to the interior of tank. (p) Inspection Cover (q) Jockey pads (r) Skids. (s) Extra busing for neutral on LV side (t) Clamping device for clamping the transformer with foundation channel. (u) HV bushing with arcing horn on HV side. (v) Cable end box on secondary side LV side. (w) Winding temperature indication with alarm and trip contacts.
Excavation in trenches in soft/loose soil not exceeding 1.5 m deep and not exceeding 1.5 mtr wide and getting out including forming bottom surface to required levels/gradients/slopes for foundations/laying of cable etc. all as specified and directed including taking out existing cable protection brick cover etc.
Returning, filling in, including spreading leveling, watering and well ramming the excavated soil in layers not exceeding 25 cm thick complete all as specified and directed
Removal of surplus excavated soil to a distance not exceeding 50 Mtr distance and depositing as directed at a level not exceeding 1.5 mtr above starting point complete all as specified and directed
M & L for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed.
M&L bricks for cover underground cable with one layer of bricks using sub class 'B' bricks (Old size) laid flat across the cable complete all as specified. (Excavation and earth work will be measured separately).
Disconnecting, taking out and removing old existing unserviceable underground, LT cable of any type and in any position complete including taking down protection pipe and seviceable bricks/ cable covers and stack up at the site properly all as specified and directed by the Engineer-in-Charge for the following sizes:
Supply , laying , connecting and testing LT 1100 volt grade electric cable XLPE insulated, screened, PVC bedded, galvanised steel strip armoured (heavy duty) ISI marked with aluminium stranded conductor gross sectional area 185 Sqmm , 3.5 core laid in trenches / duct / pipe etc complete all as specified and directed . (Note:- Earthwork & excavation shall be measured & paid separetely under respective items)
Supply , laying , connecting and testing LT 1100 volt grade electric cable XLPE insulated, screened, PVC bedded, galvanised steel strip armoured (heavy duty) ISI marked with aluminium stranded conductor gross sectional area 240 Sqmm , 3.5 core laid in trenches / duct / pipe etc complete all as specified and directed . (Note:- Earthwork & excavation shall be measured & paid separetely under respective items)
Supply , laying , connecting and testing LT 1100 volt grade electric cable XLPE insulated, screened, PVC bedded, galvanised steel strip armoured (heavy duty) ISI marked with aluminium stranded conductor gross sectional area 150 Sqmm , 3.5 core laid in trenches / duct / pipe etc complete all as specified and directed . (Note:- Earthwork & excavation shall be measured & paid separetely under respective items)
Supply & Fix 100 mm bore light grade galvanized iron tubing ISI marked including all fittings etc laid in trenches or fixed on wall protection pipe complete all as specified and directed
Disconnecting HT Electric Supply and taking down old existing Transformer of any capacity of any description and in any position from the existing indoor/outdoor substation, shifting the Transformer to AGE Em Store Yard of GE (AF) Tech AREA complete all as specified and directed by EIC.
Disconnecting, taking out and removing old existing unserviceable underground, HT cable of any type and in any position complete including taking down protection pipe and seviceable bricks/ cable covers and stack up at the site properly all as specified and directed by the Engineer-in-Charge for the following sizes:
Supply, laying & testing earthed cable XLPE insulated screened PVC bedded,galvanized steel strip or wire armored,electric power cables (heavy duty ) with stranded aluminum conductor, 11000 volts grade,of size 3 core 120 Sq mm all as specified and directed.
Supply and Fixing and testing of Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete (end joint) with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sqmm all as specified and direcetd.
Supply and Fixing and testing of Cable jointing kit for 11 KV (Earthed) grade cable for outoor termination heat shrink type joint complete (end joint) with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sqmm all as specified and direcetd.
S&F for cable jointing kit in repairs for 1.1 KV grade cable for end termination heat shrinkable type joints with jointing material and accessories suitable for 3.5 core120 sqmm XLPE insulated armoured aluminium conductor cable complete all as specified directed by Engr-in-Charge.
S&F for cable jointing kit in repairs for 1.1 KV grade cable for end termination heat shrinkable type joints with jointing material and accessories suitable for 3.5 core 150 to 240 sqmm XLPE insulated armoured aluminium conductor cable complete all as specified directed by Engr-in-Charge.
M&L for Earthing of Equipment complete with Copper earth plate electrode 60×60cm.x 3.15 mm thick, buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to Copper earth strip 20 x 3 mm thick by means of bolts, nuts, check nuts and washers of brass or connected to earthing test point and and protected by galvanized iron pipe light grade 40 mm dia upto a length of 7.5 m away from earth electrode and connected to main switch/control board including necessary excavation & earth work in any type of soil and PCC 1:3:6 type C1 for earth chamber, 40 mm thick RCC cover slab 1:2:4 type B1 with 6 mm dia TMT Bars at 140 mm c/c both ways, watering pipe 20 mm dia light grade Gl, funnel, wire mesh, lugs, charcoal and common salt etc complete all as shown in Electrical plate No. 3 of SSR Part I and testing complete including taking down the old unserviceable earthing complete all as specified and directed. Note:- (i) Copper strip and Gl pipe medium grade, up to 7.5mtr shall be deemed to be included in the rates quoted for earthing. (ii) Excavation and earth work in any type of soil strata shall be deemed to be included in rates quoted for earthing.
Supplying & Laying un-reinforced pre cast flat concrete cable protection cover of class HV, type I, size 300mm x 180mm x 40mm, factory made, complete all as specified and directed.
Disconnecting HT Electric Supply and taking down old existing VCB of any capacity of any description and in any position from the existing indoor/outdoor substation, shifting the VCB to new location not exceeding 6 KM away from the starting point and installation, fixing and commissioning the VCB connecting the incoming and outgoing connections including testing the VCB all as specified and directed Note: Fixing of VCB in existing strucuture. Rate quoted shall include repair to existing structure/platform needed as per direction of Engr-in-Charge.
Each Incomer shall be configured as follows : (a) CTs : -200-100/5 +5A (b) PT draw out type : 11000/V3/110/V3/110/3,50VA,Cl-1.0,3P (c) Feeder Protection and Control Relay, REF615 of ABB or Equivalent of L&T/ Siemens, Protections 50,51,50N,51N,46,49,95, Measurement for 3I, I0, 3U,UO,Kw, KVA, PF, Hz, Kwh, 16DI + 10 DO, One front RJ45 Port, Two Rear FO(LC) Port for IEC-61850 Protocol, Draw out Type with CT Shorting feature. Separate TCS and Master trip relay to be provided -01 Nos (d) Auxiallry relay fro transformer OTI. (e) WTI and Bucholz. Annunciator window. (f) Accessories including Breaker Control Switch (T-N-C), space heater (g) Trivecto meter with thermostat, DC , AC control circuit through MCB, Indicating Lamps for RYB, spring charge, DC healthy, Breaker ON/ OFF/ TRIP and TEST/ SERVICE position, Multifunction Meter with RS485 port for MODBUS communication (Acc.Cl.0.5), Digital Ammeter (Acc.Cl.0.5), Digital Voltmeter(Acc.Cl.0.5).
M/S ADHIKARI CONSTRUCTION CO. (BID ID -3496604)
M/S Rajeev Construction (BID ID -3496409)
Vijaypower Generators Limited (BID ID -3498611)
POONAM ELECTRIC INDUSTRY (BID ID -3502066)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.36 MB
BOQ_827408.xls
BOQ • 0.44 MB
TENDER.pdf
Tender Documents • 1.53 MB
Download all tender documents and submit your bid