Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.5 LAccepted-AOC | L1 | Accepted-AOC Being L1 and reasonable | |
| 2 | L2₹42.3 L+₹2.6 L (6.55%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹43.5 L+₹3.9 L (9.77%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | Rejected-Technical | - | Rejected-Technical Not Approved for opening of financial bid as documentation incomplete as the firm has not been submitted the reply of e-mail |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
17 Feb 2022, 6:00 pmClosed
GE(AF) GORAKHPUR
GE(AF) GORAKHPUR PIN-273008
ADDITION ALTERATION TO BUILDING NO. P-30 AKASH VIHAR, AUDIOMETRY ROOM IN ENT DEPARTMENT IN 12 AFH AND ANTI SUICIDE ROD FOR CEILING FANS AT AF STN GORKHPUR
2022_MES_503408_1
8877/E8
Open Tender
Civil Works
Item Rate
180 days
GE(AF) GORAKHPUR
As per Tender Documents
8 documents required · 8 mandatory
₹500
GE(AF) GORAKHPUR
₹88,000
Yes
2 Apr 2022
24 Jan 2022
18 Feb 2022
24 Jan 2022
17 Feb 2022
5 Feb 2022
Amount
Excavation in trenches in soft/loose soil n.exc 1.5 mtr wide and n.exc 1.5 mtr depth and getting complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation filling or mass concrete complete all as specified and directed.
Demolition of brick work built in cement mortar including all quoins, pillars etc but excluding ashlar facings, dressed stone work and pre-cast articles complete all as specified and directed.
M&L for brick work with sub class B bricks of old size, straight or curved on plan exc 6 m mean radius, built in cement mortar 1:6 complete all as specified and directed.
M&L for brick work using old size bricks with sub class 'B' bricks straight or curved on plan to any radius in half brick thick wall built in cement mortar 1:4 complete all as specified and directed.
M&L for 15mm thick rendering on fair faces of brick wall or concrete surface in CM 1:6 finished even and smooth without using extra cement complete all as specified and directed.
M&L for 15 mm thick rendering on fair faces of brick work or on concrete surface in CM 1:4 finished surface even and smooth without using extra cement mixed with liquid water proofing compound @100 ml per 50 Kg of cement bag complete all as specified and directed. Note: WPC will be measured and paid separately.
M&L for providing and injecting chemical emulsion (chloropyrifos 20% EC IS-8944, & Lindane 20% EC IS-632) for Post Constructional Antitermite but of voids in masonry using chemical emulsion one litre per hole, at 300mm intervals including drilling holes at 45 degree and repluging them with cement mortar 1:2 to match the existing floors, from authorized applicator of Pest Control of India complete all as specified and directed.
M&L for 75mm thick PCC type D-2 1:4:8 using 40 mm graded aggregate as in sub base of floor complete all as specified and directed.
Dismantling floor, hearth or wall ceramic tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all specified and directed.
M&L vitrified ceramic light colour tiles of size 600x600x10mm thick 1st quality polished, in floors etc. cut to required size set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles including 20mm thick rendering screed bed in CM 1:6 complete all as specified & directed.
All as per item No. 11 above but on vertical surface of wall of size 600X100X10mm thick as in dado/ skirting including 15mm thick rendering screed in CM 1:4.
S&F glazed ceramic coloured tiles in vertical surface 450x300x7mm thick set and jointed in neat cement slurry and pointed in coloured cement to match tiles over 10mm thick backing coat in cement mortar 1:4 complete all as specified and directed.
M&L for 75mm thick PCC (1:3:6) type C-2 using 40mm graded mechanically crushed stone aggregate as in plinth protection finished even and smooth without using extra cement with & including 10mm wide, 30mm deep joints at the rate of 3.00 mt centre to centre and at every turning & filling the joints with bitumen & sand mixture complete all as specified and directed.
Taking up or down steel tubing and connections 15mm bore including cleaning for refixing or removing from site complete all as directed.
M&L for cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar 1:3 for concealed water tubing, cutting n.exc. 10cm girth complete all as specified and directed.
S&F in repairs 15mm bore steel water tubes "medium grade" galvanized with all fittings such as bends, elbows tee etc and fixed to walls and ceiling in floor complete all as directed.
S&F in repairs bib taps 15 mm bore brass, chromium plated, fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S&F in repairs 15 mm dia brass angle cock fancy type, with capstan head chromium plated screwed down high pressure with or without lettered with long screwed shank and fly nut screwed complete all as specified and directed.
S&F in repairs Vitreous china wash down water closet pan (pedestal pattern) with any type of 'P' or 'S' trap excluding flushing cistern and flush pipe, including fixing of water closet complete with plastic water closet seat black/white closed pattern with flat bottom and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed.
S&F in repairs vitreous china wash hand basin white flat back size 550x400 mm including two Nos bracket, CP waste coupling and 32mm dia waste pipe complete all as directed.
S&F in repairs 15mm bore pillar tap fancy type cast copper alloy chromium plated screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screw shanks screwed for iron pipe or union complete all as specified and as directed.
Dismantling water tank of capacity 500 ltrs complete all as directed.
S&F rotational moulded polythylene water storage tanks 500 ltr capacity triple layered ISI marked white colour (cylindrical vertical with closed top ) hoisted and fixed in position complete with ball valve of high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball and screwed for iron pipe 20mm bore complete all as specified and directed.
S&F in repairs PVC 10 Ltrs valve less, symphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete with flush pipe etc. ISI approved complete all specified and directed.
S&F in repairs PVC connection 15mm size with PTMT nuts of length 450 complete all as specified and directed.
Taking down of rain water pipes, of any dia and pattern complete all as specified and directed.
S&F cast Iron soil waste & vent pipes 75mm bore, in any length with or without ears, with cement joints , fixed to walls complete all as specified and as directed.
M&L for extra over cast iron pipes and fittings of 75mm bore for lead joint is provided in lieu of cement joint complete all as specified and as directed.
S&F bends (any radius), diminishing pieces or tapers (larger bore measured) for 75mm bore of pipe complete all as specified and directed.
Taking down chawkhats or frame with shutter (without taking out shutter from the frame exc 1.50 Sqm and n.exc 4 sqm each and removing from site complete all as specified and directed.
S&F Factory made solid PVC Chowkhat /Door frame of size 50x47 mm with a wall thickness of 5 mm, made out of extruded 5 mm thick rigid PVC foam sheet coloured, reinforced with 19x19mm MS square tube of 19 gauge including rubber gasket, PVC fasteners, screws, brackets as per SSR Part –II (2010) complete all as specified and directed.
S&F factory made solid PVC profiled panel door shutter 28mm thick with integral skin as frame & 3mm thick high pressure compact laminate on both side of approved colour as infill, with 'C type Gl or 40 x 20 x19 of MS pipe as stiffener & supplying & fixing in frame at site as per specifications & drawing as per SSR Part –II (2010) complete all as specified and directed.
S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC frame as per specification and drawing complete all as specified and directed.
S&F 40mm thick insulated PVC Wall lining consisting of PVC insulated panels having expanded polystyrene (EPS) stuck to 2mm thick with single side prelam and wood grain printed PVC sheet duly fitted into the wall as per specifications and drawing complete all as specified and directed.
S&F powder coated anodised aluminium frame for doors, window, ventilator with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
S&F powder coated anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 02 Nos in each door, hinges, anodised aluminium snap beading, screws etc. complete all as specified and directed.
S&F powder coated anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and directed.
S&F brass Mortice lock of 04 livers, vertical type of size 100mm for aluminium joinery, complete all as specified and directed.
S&F galvanized mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanized wire staples complete all as specified and directed.
S&F in repairs galvanized mild steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanized wire staples fixed in wooden/ steel frame complete all as specified and directed.
S&F 5.5 mm thick sheet glass ordinary quality, exc. 0.50 Sqm in each pan, complete all as specified and directed.
S&F 150 mm long aluminium anodized barrel tower bolt, complete all as specified.
S&F 19/20mm dia mild steel chromium plated curtain rod, 1mm thick, complete all as specified and directed. Make : Vista Lavelor or equivalent of approved make
S&F MS curtain rod brackets for 20 mm dia rod, superior quality best available, duly coated with spray painted or PVC coated, complete all as specified and directed. Make : Vista Lavelor or equivalent of approved make
Demolition of reinforced cement concrete in chajja, landing similar suspended work, etc complete all as specified and directed.
M&L for Precast RCC 1:2:4 type B1 using 20 mm graded aggregate in shelves, slab supported on walls, set in cement mortar 1:4, complete all as specified and directed.
M&L for granite (of any type) 18 to 20mm thick machine cut and polished bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing laid over & including 15 mm thick screed bed in CM 1:6 etc complete all as specified as directed.
M&L for 40mm thick PCC 1:2:4 type B1 using 20mm graded mechanically crushed stone aggregate as in floor laid in panels finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
S&F for framed work of angle or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles as necessary gusset plate etc complete all as specified and directed.
S&F mild steel rolled work as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.of Fe-410 W (grade E-250) quality-B complete all as specified and directed.
M&L for RCC 1:1½:3 type A-1 using 20mm graded stone aggregate as in beam and lintel band complete all as specified and directed.
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
All as per Item No. 54 above but 8mm dia and over upto and including 10mm dia in stirrups, spacers and binders.
M&L for 100mm thick PCC (1:3:6) type C-2 using 40mm graded mechanically crushed stone aggregate as in plinth protection finished even and smooth without using extra cement complete all as specified and directed.
S&F mild steel framed work as in door or gates of angle or other sections with gusset plates, rails, braces etc, as in cattle traps, U channel for framed work, reinforced hinges, with ends of bars shoulders, framed guard bars and similar works complete conforming to fe 410-W (Gde E-250) quantity 'A' complete all as specified and as directed.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick (BMT) of any colour having tensile strength of 550 Mpa as in valley gutter, ridge of roof covering/ cladding to wall, fixing with self tapping screws complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.5mm thick (BMT) of any colour having tensile strength of 550 Mpa as in valley gutter, ridge of roof covering/ cladding to wall, fixing with self tapping screws complete all as specified and directed.
M&L for preparation of new or previously untreated surfaces of steel of any description, over 10cm in width or girth and apply two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for preparation new plastered surface wall and applying two coat of cement base paint over one coat of alkali resistant primer complete all as specified and directed.
Supply only integral liquid water proofing compound complete all as specified and directed. Make:- Dr Fixit Pidiproof LW+ or equivalent in specified make.
M&L for preparation of newly plastered surfaces of walls and applying two coats of oil emulsion distemper over one coat of chalk whitening complete all as specified and directed.
S&F non skid coloured heavy duty tiles (Endura) 9 to 10mm thick (square) of size 300mmx300mm, in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile laid over 15 mm thick screed bed in cement mortar 1:4 etc complete all as specified and directed.
M&L for providing 30mm thick PCC 1:2:4 type B-0 using 12.5mm graded aggregate as in sub base complete all as specified and directed.
M&L for non asbestos 4mm thick fiber cement building boards fixed or laid/inserted to aluminium frame work with screws as in false ceiling fixed in ceiling flat or sloping including aluminium anodised snap grid frame work of size 605x605mm for false ceiling with hanging arrangement of 6mm dia G .I. wire (upto 1200 mm length) adjusting level fixed to roof slab by means of ceiling cleats made out of GI flat 40x3 mm size and 60mm long and expansion hold fasteners 12.50mm dia 40mm long complete all as specified and directed.
Taking down cement or cement lime plaster any description incl racking out joints, hacking for keys, scrubbing down with water etc complete all as specified and directed.
M&L for GI galvanized iron box panel frame work of 24 gauze perforated to an extent of 70% and of 4 inch thick box panel of (8x1) in dimension. The panels with 32 & 16 Kg/Cum (glass wool as acoustic material). The material should have the ability to attain 50% insertion loss and attenuate incident sound eneery grom frequencies that are concentrated in the 125 to 8000 Hz range to meet the ANSI standards. The external surface having cladded with noise coefficient rated fabric & the encapsulated panels will be secured to floor with mild steel track frame made up of 16 gauge U channel approx size (20mmx55mmx40mm) and fasteners complete all as specified and directed.
All as per item No. 68 above but for ceiling having mild steel angle frame work ( 16 gauge mild steel powder coated L angle 50x50mm in size) to support the ceiling panels.
M&L for 5mm thick loop pile carpet the material attenuates the low frequency waves 125 to 4 K Hz and less interference from low frequency sound compete all as specified and directed.
M&L for Door frame make up of 19mm thick plywood (double layered) & steel to achieve. This will be covered externally with 3mm thick no woven fabric with appropriate door hinges, Door each door leaf will be 2 inch thick double layered plywood , insulated internally with acoustic material and externally cladded with 3mm thick non-woven fabric, suitable door handle and lock to be provided compete all as specified and directed.
M&L for double layer 8mm thick glass with the inside glass being placed at an angle of 45 degrees, if desired. this is secured to a wooden frame work with rubber gasket and silica gel compete all as specified and directed.
M&L for appropriate socket and jack pins will be provided as per the suitability of audiometer based as requirement compete all as specified and directed.
M&L for double layer gypsum of 12mm thick with GI frame work and insulated with glass wool compete all as specified and directed.
M&L for skirting/ dado of granite (of any type) 18 to 20mm thick machine cut and polished bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing laid over & including 15 mm thick screed bed in CM 1:4 etc complete all as specified as directed.
M&L for 5 mm thick coloured aluminium composite panels for false ceiling/wall cladding including fixing with self driving machine made screws with washers and fitting of same manufacture of approved profile, shape and colour with aluminium frame work complete all as specified and directed.
M&L for 12mm thick toughened glass as in doors, cup board, shelves including fixing with necessary SS clamps and other material complete all as specified and directed.
Taking down carefully point wiring complete of any type (batten/surface conduit or concealed) for light point, fan point, bell point socket point or power point complete with all fitting such as switches, sockets pendants, ceiling rose, round block etc complete and making good disturbed surfaces of wall, floor or ceiling with plaster of tiles or roof treatment etc and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as specified and directed.
M&L for concealed point wiring for one light/fan point controlled by one 5A switch using 1.5 sqmm cable (nominal area) stranded copper conductor (FRLS), single core, PVC insulated and unsheathed cable, 1100 V grade in and including concealed PVC conduit of size not less than 20mm dia all as directed with sunken type pressed steel terminal box 1.6 mm thick of suitable size, duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings/ junction boxes and wiring to be terminated in pressed steel sunken boxes with and including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor PVC insulated and unsheathed cable as in earth wire connected to common earth dolly completed all as specified and directed. Note:- (i) Rate quoted shall be inclusive of cutting chases and making good the disturbed surfaces to match the existing surface. (ii) Switches, Socket outlet, call bell, bell push and fan regulators shall be measured and paid separately.
All as per item No. 79 above but for one 5 Amps socket point controlled by one 5 Amps switch on same board.
All as per item No. 79 above but for one 5 Amps socket point controlled by one 5 Amps switch on independent board.
M&L for point wiring with (FRLS) Fire retardant low smoke PVC insulated unsheathed cable 2.5 sqmm with multistranded copper conductor, in and including non metallic PVC concealed conduit not less than 20mm dia with fittings, including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc including provision of GI terminal boxes of not less than 1.6mm wall thickness with decorative laminated sheet top cover 3 mm thick (Hylam) including (FRLS) Fire retardant low smoke PVC insulated copper earth conductor 1.50 sqmm connected to common earth and earth dolly complete for 3/6 pin 15 Amps socket outlet on independent board complete all as specified and directed. Note:-(i) Rate quoted shall be inclusive of cutting chases and making good the disturbed surfaces to match the existing surface.(ii) Switches, Socket outlet, shall be measured and paid separately.
S&F switch piano, flush type 5/6 amp, single pole, one way 240 volt complete all as specified and directed.
S&F switch piano, flush type 15 amp, single pole, one way 240 volt complete all as specified and directed.
S&F socket outlet, 3/5 pin, 5/6 amps flush type 240 volt complete all as specified and directed.
S&F socket outlet, flush type, 2 in 1, 3 pin 5 & 15 Amps, 230 Volts, multipurpose complete all as specified.
S&F ceiling rose surface polycarbonate 65X50mm three terminals complete all as specified and directed.
S&F fan regulator electronic step up type, SP 230 volt complete all as specified and as directed.
S&F 20 watt LED light fitting engineering plastic batten with white acrylic cover LED light (integrated LED channel) natural white, energy saving complete with its all accessories internally perwired and including connecting up with twin core twistered flexible copper conductor cable of suitable size complete all as specified and directed. Make:- Havells Cat part No. ENDURA LINE ARNE OBS20WLED865S PCWH or equivalent in Bajaj / CG.
S&F, testing energy saving, die cast aluminium housing IP 65 protection, 35 W LED street light fitting with high power LED as light source complete fixed on pole using 30x5mm FI clamps, nuts, bolts & washers all as per site requirement complete all as specified and directed. Make:- Havells Cat No. ENDURA CITYLITEPLAT PLUSSL35W LED 757SASYBOPC or equivalent in Bajaj/ Philips/ CG/ WIPRO
S&F factory made epoxy powder coated distribution board double door TP& N 4 ways (VTPN MCB DB) with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knock outs complete all as specified and directed.
S&F MCB, SP, 6 to 32 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed.
S&F MCB, SPN, 40 Amps, 'C' curve, 10 KA breaking capacity, 240 volts complete all as specified and directed.
S&F MCB, TPN, 25 to 63 Amps, 'C' curve, 10 KA breaking capacity, 415 volts complete all as specified and directed.
S&F in replacement sheet metal enclosures with socket plug top and MCBs with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified.
M&L for concealed sub main wiring with 2 Nos single core PVC insulated unsheathed 2.5 sqmm stranded copper conductor cable (FRLS) and 1 No single core PVC insulated-unsheathed 1.5 sqmm stranded copper conductor cable (FRLS) for earth continuity, drawn in & including suitable PVC conduit pipe with all fittings ISI mark of Ivory/Grey/white colour medium grade for flame proof fixed in wall or on ceiling complete all as specified and directed. Note: (i) Length of 2 No 2.5 sqmm conductor cable, 1 No 1.5 sqmm conductor earth continuity cable and accessories shall be measured as one unit length. (ii) Rate quoted shall be inclusive of cutting chases and making good the disturbed surfaces to match the existing
S&F wall mounted fan complete AC 240 volts 50 Hz single phase of size 400mm sweep including making connection from ceiling rose to fan connector complete all as specified and directed. Make: Model Flatina HS of Havells of equivalent in Crompton / Usha/ Bajaj
Returning, filling in including spreading, leveling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed.
Removing surplus excavated material not exc 50 mtrs and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
Supply and providing sand cushioning with dry clean sand 15 cm below cable and 8 cm above the cable complete all as specified and directed. Note: Punned thickness shall be measured for the purpose of payments.
Supply and laying burnt bricks old size sub class-B laid in trenches for cable protection with length of brick perpendicular to length of cable complete all as specified and directed.
Supply, laying and testing 50Sqmm, 3.5 Core XLPE insulated, armoured heavy duty electric cable, screened PVC bedded, galvanised steel strip or wire, with aluminium conductor 1100 V grade, laid in trenches/ along poles, ducts or through sleeve complete all as specified and directed.0 Note: Earth work, sand cushioning and bricks will be measured and paid separately under relevant items.
M&L for concealed PVC conduit pipe with all fittings medium grade for F Net and communication wiring complete all as specified and directed.
S&F factory made epoxy powder coated distribution board double door TP& N 4 ways (VTPN MCCB DB) with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knock outs complete all as specified and directed.
S&F MCCB, 4 pole, 100 Amps, 16KA current rating with adjustable thermal and magnetic setting conforming to IEC-617472 & IS-139473 to be fixed in distribution board complete all as specified and directed.
S&F modular switch single pole 1 way, 1 module, 6 Amp complete all as specified and directed.
S&F modular switch single pole 1 way, 1 module, 16 Amp complete all as specified and directed.
S&F modular socket out let multipurpose 6A/16A-2/3 pin, SP 1 way 2 module complete all as specified and directed.
M&L for concealed sub main wiring with 2 Nos single core PVC insulated unsheathed 4.0 sqmm stranded copper conductor cable (FRLS) and 1 No single core PVC insulated-unsheathed 2.5 sqmm stranded copper conductor cable (FRLS) for earth continuity, drawn in & including suitable rigid steel conduit pipe with all fittings ISI mark of Ivory/Grey/white colour medium grade for flame proof fixed in wall or on ceiling complete all as specified and directed. Note: (i) Length of 2 No 4.0 sqmm conductor cable, 1 No 2.5 sqmm conductor earth continuity cable and accessories shall be measured as one unit length. (ii) Rate quoted shall be inclusive of cutting chases and making good the disturbed surfaces to match the existing
Supply and install and testing split type air conditioner of capacity 2.0 Ton, 5 star rating inverter type for working on 230 volt, SP, 50 Hz supply complete including cutting of existing wall and proper fixing making good disturbed surface with existing surface and providing water pipe upto ground level complete all as specified and directed. Make : Carrier/Voltas/Bluestar/Hitachi/LG
Taking down ceiling fans of any size, any make fixed / hanged at different location, dismantling the fan complete cleaning and re-assembling the same including replacing Anti Suicide down rods, split pins flexible copper cable of size 23/0.0076 twin core, 70 cm long and refixing the ceiling fan on the same location in original position, testing and commissioning of fan for smooth running, as per entire satisfaction. Note:- (i) Quoted rate of any item of the schedule is inclusive of taking down the ceiling fans from the position and re-fixing / hanging in position connecting and testing complete. (ii) Anti suicide down rods replacement of spares shall be measured and paid separately.
S&F in replacement 10" 'Gold Life' Smart MS down rod (Anti Suicide Fan Rod) white colour for ceiling fans of any size and make complete all as specified and directed. Make: Gold Life Smart Fan down Rod HSN/SAC code 8414 or equivalent as approved.
M/s Durgesh Kumar Mishra
M/S ARORA CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .