Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.8 LAccepted-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹9.5 L+₹61,787 (6.98%)Rejected-Finance SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | L2 | Rejected-Finance NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹18,900
Closing Date
19 Dec 2020, 6:00 pmClosed
MAJ VIKAS KUMAR SRIVASTAVA, GE
GARRISON ENGINEER DAMAN TAT RAKSHAK VIHAR DALWADA NANI DAMAN POST DAMAN (UT) PIN 396210
PROVISION OF AIR CONDITIONERS FOR OTM COMPLEX AT ICGS DAHANU AND PROVISION OF AUTOMATIC BOOM BARRIER AT MAIN GATE OF ICGS DAHANU
2020_MES_390293_2
8498/E8
Open Tender
Civil Works
Item Rate
180 days
DAHANU
PLEASE REF TENDER DOCUMENTS
9 documents required · 9 mandatory
₹50
GARRISON ENGINEER DAMAN
₹18,900
Yes
6 Jan 2021
28 Nov 2020
21 Dec 2020
28 Nov 2020
19 Dec 2020
5 Dec 2020
Amount
Supplying ,installalling , testing and commisioning of split type air conditioner 2.0 TR capacity of inverter technology 5 star rating with cordless remote control, single phase, 240 volts complete with all accessories such as indoor and outdoor units and refrigerant tubing of adequate length as required at site, indoor mounting plate, drain pipe of suitable size brought to ground level from any height including making cable connection by providing three core 4 sqmm copper conductor cable PVC insulated, sheathed of adequate length as required at site and including initial filling of refrigerant gas including making round hole on existing any type of wall (core cutting if required) for taking up refrigerant tubing, drain pipe and cables etc and making good the disturbed surface by matching with existing adjoining surfaces complete all as specified and directed. Make:- DAIKIN/BLUESTAR/LG/VOLTAS/SAMSUNG
Supply,install, testing and commisioning of split type air conditioner 1.5 TR capacity of inverter technology 5 star rating with cordless remote control, single phase, 240 volts complete with all accessories such as indoor and outdoor units and refrigerant tubing of adequate length as required at site, indoor mounting plate, drain pipe of suitable size brought to ground level from any height including making cable connection by providing three core 4 sqmm copper conductor cable PVC insulated, sheathed of adequate length as required at site and initial filling of refrigerant gas including making round hole on existing any type of wall (core cutting if required) for taking up refrigerant tubing, drain pipe and cables etc and making good the disturbed surface by matching with existing adjoining surfaces complete all as specified and directed. Make:- Daikin / Blue Star / Voltas
Supply and fixing electronic voltage stabilizer wall mounted type, suitable for Air conditioner 1.5/ 2.0 TR capacity of input voltage 230 volts, single phase, AC, 50 Hz and working range between 170 volts to 270 volts, intelligent time delay 3 minutes +/- 20 seconds including necessary cable connections and testing complete all as specified and directed. Make:- V-Guard model No VG 500 or equivalent make in Microtech / Vintec / Sinetrac.
Supply and Fix single pole and neutral sheet steel enclosure complete with 2 pin and earth plug and socket including MCB SP 20 Amps, 10KA 'C 'series, 240 volts complete all as specified and directed. Make:- L&T/ Legrand/Schneider/Havells
S&F MCB SP 32 Amps 10 KA "C" series, 240 volts,50 Hz complete all as specified and directed. Make :- L&T/ Legrand/Schneider/ Havells/ ABB.
Material and Labour for submain wiring by using proper colour code with two runs of 4 sqmm, PVC insulated, unsheathed, single core, multistranded copper conductor cable, ISI marked, 1100 volts, FRLS grade andone run of 4 sqmm, PVC insulated, unsheathed, single core, multistranded copper conductor cable, ISI marked, 1100 volts, FRLS grade as earth continuity conductor connected to common earth dolly drawn in and including PVC casing and capping of size not less than 25 mm, ISI marked with accessories on surface of wall/ceiling/beams/columns etc and making good the disturbed surface by matching with existing adjoining surfaces complete all as specified and directed. Note:- Three runs of 4.0 sqmm cable and one run of PVC casing and capping will be measured as one unit for payment purpose. Make of copper cable:- Finolex/L&T/Havells/KEI/Elektron Make of PVC casing caping :- Precision/Finolex/Supreme/Prince.
Supply & Fix MS wall bracket prefabricated ,duly painted suitable for fixing of out door unit of split type Air Conditioner with necessary nuts, bolts & washers and making good disturbed surfaces to match with the existing complete all as specified and directed.
Supply,Install, Testing and commissioning Automatic type rising Boom Barrier with electro-mechanical drive mechanism with interlocking feature cicuit controller for auto off in fully raised and lowered position with limit switches and manual operation in case of power failure with aluminium hosing Boomconnector,rectangular Boom and reflacting warning tape and rubber buffer, erogonomical emergency relaease, drilling template, completely prewired terminal row ,maintenance main power outlet,double pole circuit breaker including civil works as per manufacturers instructions for installing rising Boom barrier complete all as specified and as directed comprising of following specifications :- Make:- Godrej & Boyee, CAME, FOREMOST SYSTEM (a) Boom length -6 meter (b) Hight of Boom from Ground - 914mm (c) Controller protecting rating : IP 54 (d) Opening Time : 3 To 6 Sec (e) Motor power Supply :- 24 Volts DC (f) Boom Dimention :- 100X40mm (g) Duty cycle :Intensive (h) Electronic circuit shall be automatic switch off motor in case of fault (j) Housing Dimension ( Approximate mm) : 450X295X1077 (k) Power Supply :Single phase, 230Volts, AC, 50Hz (l) Operating temperature :-20 Degree to 55 Degree C Note :-(i) Smooth operation of Barrier will be there while opening and closing without any jerk at the end position (ii) The Barrier must be compatable for integration with access control system (iii) The Barrier operation will be either push button installed in security cabin or cordless remote (10 -15 meter rang) (iv)In case of power failure barrier can be raised/ lowered by releasing the boom lock with key type mechanism ( Mannually) (v) Power supply will be provided by department at one point only, All necessary cabling work including control cables work will be done by contractor only (vi) All civil work required for installation of Boom barrier and component as per manufacturers instruction for smooth operation of boom barrier is deemed to be included in the quoted rate (vii) The installation work shall be carried out in supervision of representative of manufacturer/ dealer
Supply, laying, testing LT cable, XLPE insulated, galvanized steel strip armoured, 1100 volts grade with multistranded aluminium conductor of cross sectional area 6 sqmm ,2 core laid in trenches/through pipes, ducts and walls etc including making cable connections with necessary aluminium lugs duly crimped properly and stainless steel glands,nuts,bolts and washers etc and removing old unserviceable item complete all as specified and directed. Make:- Polycab/Havells/Finolex/KEI
Supply & fixing sheet metal enclosure single door 240 volts AC,SPN distribution board 4 way painted with epoxy based powder coated painting suitable for mounting MCB DP/SPN incomer and MCB SP/DP as out goings and complete with 200 Amps rated busbar ,neutral bar,earth bar connecting cable links with top and bottom removeable gland plate complete with IP 43 protection all as specified and as directed. Make :- Legrand/ L&T/ Seimens/Havells
S&F MCB SP 32 Amps 10 KA "C" series, 240 volts,50 Hz complete all as specified and directed. Make :- Legrand/ L&T/ Seimens/Havells
Material and Labour for submain wiring by using proper colour code with two runs of 2.5 sqmm, PVC insulated, unsheathed, single core, multistranded copper conductor cable, ISI marked, 1100 volts, FRLS grade and one run of 1.5 sqmm, PVC insulated, unsheathed, single core, multistranded copper conductor cable, ISI marked, 1100 volts, FRLS grade as earth continuity conductor connected to common earth dolly drawn in and including PVC conduit of size not less than 25 mm, ISI marked with accessories on surface of wall/ceiling/beams/columns etc and making good the disturbed surface by matching with existing adjoining surfaces complete all as specified and directed. Note:- Two runs of 2.5 sqmm cable and one run of 1.5 Sqmm as earth conductor and PVC conduit will be measured as one unit for payment purpose complete all as specified and directed. .
Supply & fixing MCBs SP, 6 to 40 Amps , 10 KA,"C" series complete all as specified and directed. Make :- Legrand/ L&T/ Seimens/Havells
M&L for Earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6.0 mm thick buried directely in ground vertically (earth pit not less than 2.25 metres deep below ground level) with top edge of the earth plate not less than 1.5 metres below ground level connected to and including galvanised steel wire of size 4 mm dia protected by GI pipe 15 mm dia light grade upto 7.5 metres or upto equipment which ever is less by means of GI bolts, nuts, check nuts and washers etc and providing GI watering pipe 20 mm dia medium grade, GI funnel with wire mesh including charcoal, salt packed all around the earth plate in layers and PCC earth pit chamber 1:3:6 type C1, RCC cover 1:2:4 type B1 of 50mm thick all as per electrical plate No.3 of SSR pt-I including necessary excavation/earth work in any strata, returning filling, removal of surplus soil and testing for required value including removing old unserviceable item complete all as specified and directed. Note:- GI wire 4 mm dia beyond 7.5 metres will be measured and paid seperately.
Cutting of existing bituminous surface/PCC hard standing by using mechanical method of any type for laying of cables/GI protection pipe and making good of disturbed surfaces to match with adjoining surface complete all as specified and directed Note:-PCC for making good shall be measured and paid separately)
M & L for PCC 1:3:6 type C2 using 40 mm graded stone aggregate for making good of disturbed surfaces including necessary use and waste of form work complete all as specified and directed
Supply and filling in and spreading unwashed river sand for cushioning and covering the UG cables in trenches of 23 cm thick layer and punned down to 18 cm from 23 cm by compacting complete all as specified and as directed. Note:- Punned down thickess of 18 cm shall be measured for payment purpose.
Supply and laying unreinforced precast concrete cable cover class LV, Type-1, flat of size 250mm x150mm x 40mm complete all specified and directed. Make :MEHTAB or equivalent
Excavation in trenches not exc 1.5 m wide and not exc 1.5m in depth for laying of pipes and foundations etc and getting out in any soil complete all as specified and directed
Returning, filling in soils including spreading leveling watering and well rammimg in layer not exc 25 cm thick each layer complete all as specified and directed
Removing of excavated soil not exc 50 mtrs distance and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed
Supply and laying GaIvanised iron pipe 40 mm dia 'light grade' with fittings for protection of UG cables laid in trenches/ road crossing/culvert crossing, along the wall, floors, on roof, on pole etc complete all as specified and directed. Make :- Tata/Jindal/Swastik
cooltech engineering services
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .