Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical Technically Qualified |
| 2 | Accepted-Technical | Accepted-Technical Technically Qualified |
| 3 | Rejected-Technical | Rejected-Technical Technically Disqualified |
Tender Value
₹6.7 L
EMD Value
₹13,000
Closing Date
2 Mar 2026, 5:00 pmClosed
GSM (PNC), TLD-IV PS, Kalijhora
Teesta Low Dam-IV Power Station, P.O.- Kalijhora Bazar, Distt - Darjeeling, West Bengal-734008
Repairing of Sub-Station Room at TLD-IV Power Station, kalijhora
2026_NHPC_897937_1
NH/TLD-IV PS/PNC/W-944/2026/2160
Open Tender
Civil Works
45 days
Teesta Low Dam-IV Power Station, P.O.- Kalijhora B
Please refer Tender documents.
8 documents required · 8 mandatory
₹590
NHPC Limited
₹13,000
Yes
30 Mar 2026
11 Feb 2026
9 Mar 2026
11 Feb 2026
2 Mar 2026
11 Feb 2026
Strippingoffwornoutplasterandrakingout jointsofwalls, celings etc. uptoany height and inany floor including removing rubbish within a lead of 75m as directed
Plaster (to wall, floor, ceilingetc.) with sand and cement mortar including rounding off or chamfering corners as directed and racking out joints including throating nosing and drip course, scaffolding/staging where necessary (ground floor). (Excluding cost of chipping over concrete surface) - with 1:4 cement mortar - 15 mm thick plaster
Cement concrete with graded stone ballast (40mm size excluding shuttering)In ground floor-With N.B. Variety stone metal.-1:3:6 proportion
Supplying, fitting &fixing 1st quality Ceramic tiles inwalls and floor stomatch with the existing work & 4 nos. of key stones (10mm) fixed with araldite eat the back of each tile& finishing the joints with white cement mixed with colouring oxide if required tomatch the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. Wall -With Sand Cement Mortar (1:3) 15mm thick & 2mmthickcement slurry at back side of tiles using cement @2.91Kg/Sq.m & joint filling using white cement slurry @0.20kg/Sq.m. Other than Coloured decorative including white.
Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floor stomatch with the existing work & 4 nos. of key stones (10mm) fixed with araldite eat the back of each tile & finishing the joints with white cement mixed with colouring oxide if required tomatch the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. Floor. With Sand Cement Mortar (1:4) 20mm thick & 2 mm thick cement slurry at back side of tiles using cement @2.91Kg/Sq.m & joint filling using white cement slurry @0.20kg/Sq.m. Area of each tile upto 0.09 Sq.m-Other than Coloured decorative including white.
Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materialsatsiteandremovingrubbishasdirectedwithina lead of 75 m- In ground floor including roof.
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc. initial straightening and removal of loose rust (if necessary), cutting to requisite length hooking and bending to correct shape, placing in proper position and binding with 16-gauge black annealed wire at every inter-section, complete as per drawing and direction. (a) For works in foundation, basement and up to roof of ground floor/up to 4m) (i)Tor steel/Mild steel III. Others manufacturers not specified.
25 mm thick damp proof course with cement concrete with stone chips (1:1.5:3) (with graded stone aggregate 10mm nominal size) and admixture of water proofing compound as per manufacture's specification followed by two coat of polymer based paint (1st coat after 4 to 5 days of concrete laying and 2nd coat just before brick masonary work) as directed. (Cost of water proofing compond and polymer based paint to be paid seprately). (Chequering not required over concrete or painted surface).
Extra rate for using wate proofing and plastering admixtuere @ 0.2% by weight of cement (or at manufacture's specified rate) for concrete of various grade.
Supplying, fitting and fixing E.W.C. in white glazed vitreous chin aware of approved make complete in position with necessary bolts, nuts etc.(a) With 'P' trap.
Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete, C.I. brackets including two coats of painting to bracket etc.
Supplying, fitting and fixing bib cock or stop cock. Chromium plated Bib Cock (angular shape with wall flange) (Equivalent to Code No. 5037 & Model-Florentine of Jaquar or similar brand).
Supplying, fitting and fixing bib cock or stop cock. Chromium plated Stop Cock (Equivalent to Code No. 513(A) & 513(B) & Model-Tropical / Sumthing Special of ESSCO or similar.
Dismantling wash basin with brackets with or without waste fittings.
Supplying, fitting and fixing pedestal of approved make for wash basin (white)
Supplying, fitting and fixing pillar cock of approved make. CP Pillar Cock - 15mm. (Equivalent to Code No. 507 & Model - Tropical / Sumthing Special of ESSCO or similar brand)
Supplying, fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia.-600 mm long.
Supplying, fitting and fixing approved brand 32 mm dia. P.V.C. waste pipe, with PVC coupling at one end fitted with necessary clamps- 600 mm long
Supplying fitting and fixing beveled edge mirror 5.5mm thick silver red as per IS 3438/1965 together with brass CP hinges. 600 x450 mm.
Supplying, fittingand fixing towel rail with twobrackets C.P. over brass-25 mm dia. and 750 mm long
Providing , fitting and fixing of chromium plated Health Faucet of including 8mm dia 1 Meter long flexible tube and wall hook of approved make/ best quality all complete.
Taking out door and window shutters and rehanging the same with old fittings. -With new iron screws.
Supplying solid flush type doors of commercial quality, the timber frame consisting of to pand bottom rails and side styles of well seasoned timber 65 mm wide each and the entire frame fitted with 7.5 mm wide battens places both ways inorder to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor.-32 mm thick shutters (single leaf)
Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws: 150mm long x 10mm dia. Bolt.
Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete: With continuous plate base (Hexagonal/ Round rod)-100 mm grip x 10 mm dia rod.
Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark.-100 mm. X 75 mm. X 3.50 mm.
Applying Interior Grade Acrylic Primer of approved quality and brand on plastered or concrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor)–One Coat-Water based interior grade Acrylic Prime
Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : (Two coats-Luxury Quality
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or concrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC-In Ground Floor: One coat
Applying decorative cement based paint of approved quality after preparing the surface including scraping the same thoroughly (plastered or concrete surface) as per manufacturer's specification-In Ground floor-Two coat
M.S. structural works in columns, beam setc. With simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, c leats as per design, direction of Engineer-in charge complete including cutting to requisites hape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816-1969 &IS:1995usingelectrodesofapprovedmake and brandc onforming to IS: 814-2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc. Payment tobemadeonthebasisofcalculatedweightof structural members only in finished work as per IS specified weight. Payment for gusset, bracket, cleat, rivets, bolts and nuts may be make by adding the actual weight of such items with the weight of finished structural members or 7% of weight for finished structural members weigh ing not less than 22.5Kg. /m. or 15% of weight for finished structal members weighing less than 22.5Kg. /m. may be increased allow for bracket, cleat, rivet, bolts and nuts etc. and no seperate payment being made for these items, as per direction of Engineer In Charge. The rates are considered for a height of erection 8m. / 2nd floor level
Supplying, fitting and fixing single skin color coated trapezoidal profile for wall cladding, Roof shall be made of 0.45 mm BMT (Base Metal Thickness) 0.50 mm TCT (Total Coated Thickness excluding paint), G550 (min 550 yield strength), of zincalume metallic coating (lS15965) with high Solar Reflectance Index (SRI) value for better coIIingas per thermatech technology, 1000 1015 mm effective cover width with five major corrugation, 28 mm high rib spaced at 203mm c/c with suitable square fluting in the pan and the end rib shall
Please Enable Macros to View BoQ information
stage.html
html • 0.02 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.78 MB
NewTenderDocuments.pdf
Tender Documents • 3.97 MB
BOQ_943827.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid