Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹3.6 CrAccepted-AOC | ₹3.6 Cr | 1 | Accepted-AOC Lowest |
| 2 | 2₹3.9 Cr+₹33.4 L (9.39%)Rejected-AOC | ₹3.9 Cr+₹33.4 L (9.39%) | 2 | Rejected-AOC . |
| 3 | 3₹4.1 Cr+₹56.2 L (15.8%)Rejected-AOC H NO 1100 SECTOR 3 124001 | ROHTAK | HARYANA | 124001 | ₹4.1 Cr+₹56.2 L (15.8%) | 3 | Rejected-AOC . |
Tender Value
₹3.6 Cr
EMD Value
₹7.2 L
Closing Date
19 Oct 2023, 5:00 pmClosed
ABHISHEK SHER
EE PHE Division Sohna
Laying of combined pipe channel for 4.5 MLD STP at Pataudi and 5.5 MLD at Haily Mandi for drainage of treated effluent upto drain no. 8 (Najafgarh drain) under PHE Division Sohna District Gurugram.
2023_HRY_320234_1
2023E637C904 0B06 4A88 ADB3 0556459A14E4558PUH
Open Tender
Civil Works
Works
360 days
Pataudi Haily Mandi
.
2 documents required · 2 mandatory
₹15,000
₹7.2 L
Yes
29 Jan 2024
13 Oct 2023
20 Oct 2023
13 Oct 2023
19 Oct 2023
13 Oct 2023
Amount
Providing and Fixing Cast iron detachable Joints Cl-15 marked with IS:8794 for use with asbestos cement pressure pipes complete with 2 nos. rubber rings marked with IS:5382 and IS: 10292 and appropriate number of nuts and bolts marked with IS:1363 including carriage, loading, unloading etc. complete in all respects
Providing and Fixing Cast iron detachable Joints Cl-15 marked with IS:8794 for use with asbestos cement pressure pipes complete with 2 nos. rubber rings marked with IS:5382 and IS: 10292 and appropriate number of nuts and bolts marked with IS:1363 including carriage, loading, unloading etc. complete in all respects -800 mm i/d
Extra for fixing sluice valve/flap valves socketed or flanged including cartage from stores or nearest railway station to site of work. 800 mm i/d
35 sqmm 3 core XLPE Cable Supply and erection of XLPE (E) 11 KV HT Aluminium conductor armopured cable ISI marke laid in 1 mtr below ground level with sand and bricks with all labour and material including digging and refilling of trench, required to complete the job in all repect upto the entire satisfaction of the Engineer-in-Charge of the works.
50 sqmm 3 core XLPE Cable Supply and erection of XLPE (E) 11 KV HT Aluminium conductor armopured cable ISI marke laid in 1 mtr below ground level with sand and bricks with all labour and material including digging and refilling of trench, required to complete the job in all repect upto the entire satisfaction of the Engineer-in-Charge of the works.
70 sqmm 3 core XLPE Cable Supply and erection of XLPE (E) 11 KV HT Aluminium conductor armopured cable ISI marke laid in 1 mtr below ground level with sand and bricks with all labour and material including digging and refilling of trench, required to complete the job in all repect upto the entire satisfaction of the Engineer-in-Charge of the works.
Supply and erection testing and commissioning wall mounted electrical panel board, fabricated from 16 SWG CRCA sheet duly stouted with suitable angle iron frame work and completely powder coated ofapproximate size 1200x900 mm and 400 mm deep having following accessories - 1100 LPM x 35 M head motor for clear water at BS-1 and 2
Supply and erection testing of ISI marked copper wire for 8 nos. Motors with underground system in PVC and flexible pipes copper wire size 10 mm sq. 3 core and 6 mm sq 3
Supply and erection testing of ISI marked copper wire for 8 nos. Motors with underground system in PVC and flexible pipes copper wire size 6 mm sq. 3 core and 6 mm sq 3 core
Boring/ Excavation including making thrust pit and receiving pit to the precise dimensions for the launch of the specialized Auger boring machine in normal soil condition but not in Rock/ Boulders/ any underground utility like, foundation, water supply line coming in alignment or other under ground obstruction under Gurugram-Jhajjar via Farrukh Nagar Road and Gurugram-Rewari Road near STP and Railwa crossing near Mirjapur Village suitable for MS casing pipe of following sizes including caution and sign board complete in all respects for 1224 mm o/d MS pipe 12 mm thick casing pipe 1x 60=60 Mtr. 60 15000/- per meter 900000 and 924 mm 3 x 30= 90 meter
Providing and insertion of MS casing pipe (Fe 330 grade) fabricated s per IS 3589 of 1991 from steel plates conforming to IS2062 of following size including cutting, beveling grinding and radio graphically welding of pipes as per IS 1182 Complete in all respects including cartage to site of work and testing For 1224 mm o/d MS pipe 12 mm thick casing pipe 1x 60=60 Mtr
Coating of outer surface of casing pipe with P.U coating to dry film thickness 1500 micron for protection against corrosion complete in all respects.
Prov concrete block (1:1 ½:3) on both side to plug angular space between casing pipe and carrier pipe including cost of 5 mm thick MS plate complete in all respects.
Provand fixing HDPE spacer at a distance of 2 meter or part thereof to avoid contact of casing pipe and carrier pipe complete in all respects.
Ground probe radar survey to check any under 1 ground obstruction before finalizing the alignment complete in all respects.
Supply, Erection, testing and commissioning of Electromagnetic type flow meter suitable to measure discharge 50 cum / hr. to 160 cum/hr.as per specifications
Supply, fixing, testing and commissioning IVC make D.I.recoil non return type Zero Velocity valve having body in D.I. to IS: 1865 Gr. 400/15, Slant seat design, PN-1.6 rating, flanges to be drilled as per IS: 1538 complete in all respect to the satisfaction of Engineer-in-charge
Supply, Fixing, testing and commissioning M/s D/F pipe for scouring arrangement complete in all respect as per DNIT to the satisfaction of Engineer-in-Charge. 100 mm i/d.
Bidder Name
Amount
yudhvir singh(GSTN-06ACXPS5293E1ZX)
Kulbir Singh Contractor(GSTN-06ATZPS6352H1ZW)
Mukesh Rathee contractor(GSTN-NA)
Kulbir Singh Contractor
Mukesh Rathee contractor
Mukesh Rathee contractor
Kulbir Singh Contractor
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .