Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.0 LAccepted-AOC | L1 | Accepted-AOC BeingL1 | |
| 2 | L2₹23.7 L+₹1.2 L (5.40%)Rejected-Finance | L2 | Rejected-Finance BEING NOT L1 | |
| 3 | L3₹26.0 L+₹3.5 L (15.6%)Rejected-Finance | L3 | Rejected-Finance BEING NOT L1 | |
| 4 | L4₹26.3 L+₹3.8 L (17.0%)Rejected-Finance | L4 | Rejected-Finance BEING NOT L1 | |
| 5 | L5₹26.4 L+₹3.9 L (17.5%)Rejected-Finance 154 HANUMAN MANDIR DIKSHI TAL NIPHAD DIST NASHIK 422 302 | NASHIK | MAHARASHTRA | 422302 | L5 | Rejected-Finance BEING NOT L1 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
19 Jul 2022, 6:00 pmClosed
GE AF OJHAR
GE AF OJHAR
REPAIR AND MAINTENANCE OF UNSERVICEABLE FAN EXHAUST FAN FAN CIRCULATOR GEYSER OTHER CONNECTED WORK AND REPAIR REPLACEMENT OF UNSERVICEABLE OLD WIRING FITTINGS FIXTURES DAY TO DAY MAINTENANCE OF ELECTRIC FITTINGS AND METERING PANEL AT DOMESTIC AND TEC
2022_MES_531469_1
8878/E8
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
OJHAR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF OJHAR
₹60,000
Yes
2 Aug 2022
16 Jun 2022
21 Jul 2022
17 Jun 2022
19 Jul 2022
29 Jun 2022
Amount
Supply and fix in repair Switch piano flush type single pole one way 5 Amp , Make Anchor/ Havells Rio,Complete all as specified & as directed by Engineer-In-Charge. Note applicable for BOQ item no 1 to 112 (a)contractor rep/ superviser shall be present at office of Engineer-In-Charge at 9AM every day for taking of instruction regarding repairs to be carried out on the day on priority,(b) alternative Electricians deploy in place of regular electrician has to work on sunday/holiday to attend faults/defects/complains.In case if electrician fails to rectify the faults then recovery shall be recovered from contractor s any due payment(c)The repair work on any single day may be order by Engineer-In Charge to be carry out in number of places/building in one day i.e in one buildings quantity of any of BOQ items to be carried may be one or more & number of BOQ items to be executed on any single day may also be one or more(d) Contractor shall not have any claim on account of order of one or more quantity of one or more items of BOQ that to be executed in one or more building and or area in any single day & even the same on any numbers of day during contract period(f) all above mentioned labour effect on this account is deemed to be included in quoted rates by the tenderer for all items of this tender.Note:1) Complaints/Defects will be rectified withen 8 Hrs of intimated time. if complaints not rectified, a recovery of an amount of Rs150/-/ complains/ day will be recoverd from the RAR/ FB , ii) Rates are inclusive of T&P required safety equipment, and transport required contractor shall arrange on his own arrangement, iii).Compliant given by any electronic media i.e SMS, email or whats app etc and in writting shall be count as valid compliant contractor to take immediate action within stipulated time as mention in note -1 above.
Supply and fix in repair Modular switch one way 6 Amp,1 Module , Make Anchor/Roma/Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Modular switch one way 16 Amp, 1 Module , Make Anchor/ Roma,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Modular bell push 6 Amp,1 Module , Make Anchor/ Roma/Legrand,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Modular Fan regulator electronic step type 230 V 2 Module. Make : Anchor/Roma Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Modular Socket outlet 6A/16 Amps 2/3 pin combined 2 module Make : Anchor/Roma. ,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Modular Socket outlet 6 Amps 2/3 pin combined 2 module Make : Anchor/Roma ,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Bell push flush type 5 Amps. Make : Anchor/Havells Rio,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Fan regulator electronic step type 230 V. 120W . Make : Anchor/Havells Rio.,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Bell buzzer,AC 230 Volts single pole. Make : Anchor/Press Fit,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Ding Dong AC 230 Volts single pole. Make : Anchor/Press Fit,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Socket out let 2 in 1, 5 pin 5 Amps flush type. Make : Anchor/Havells Rio.,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Switch socket combination outlet 5 pin 6 Amps 16 Amps 2 in 1 flush type.Make: Anchor/Havells Rio.,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Switch socket combination outlet 5 pin 5 Amps 2 in 1 flush type Make : Anchor/Havells Rio.,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Plug top 3 pin 5 Amps Make Anchor/Leader/Cona
Supply and fix in repair Plug top 3 pin 15 Amps Make Anchor/Leader/Cona
Supply and fix in repair Lamp holder PVC/polycarbonate insulated body with back plate suitable for angle fittings. Make : Anchor/Havells Rio.,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair LED Lamp 9 watt/12 watt Make : Anchor/Havells Rio.,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Ceiling rose surface type, PVC/Polycarbonate isolated body size 50x28 mm three terminals. Make : AnchorHavells Rio.,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair MCB SP 6 to 32 Amps 240 volts 10 KA C series. Cat part No-408595 Make : Legrand/ L & T./Standard ,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair MCB SPN 32 to 40 Amps 240 volts 10 KA. Cat Part No-408617 Make : Legrand /Standard/L & T,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair MCB TPN 32 to 40 Amps 240 volts 10 KA. Cat Part No- 408680 Make : Legrand Standard L & T,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair MCB TPN 63 to 100 Amps 240 volts 10 KA. Cat Part No-408683 Make : Legrand Standard /L & T,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Sheet metal enclosure for DB’s 2 way 240 volts. Make : Standard/HPL/Legrand,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Sheet metal enclosure for DB’s SPN, with 200 amps rated bus bar , 4 way ,240 volts double door. Make : Standard/HPL/Legrand.,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Sheet metal enclosure for DB’s SPN, with 200 amps rated bus bar ,8 way ,240 volts double door. Make : Standard/HPL/Legrand.,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Sheet metal enclosure for DB’s TPN, with 100 amps rated bus bar , 4 way ,415 volts double door. Make :Standard/Legrand/L&T.,Complete all as specified & as directed by Engineer-In-Charge.
Supplying and fix in repair sheet metal enclousers with socket, plug top and MCBs, single pole and neutral enclouser with a two pin and earth plug and socket complete with one single pole MCB , single pole, 240 V of capacity 20 amps , complete all as specified and as directed by Engr-in-Charge.
Supply and fix sheet metal distribution board 415volt,Vertical TPN 4 Way with provision for DHx100 series MCCB of legrand make as incomer and SP/TP MCBs as outgoing as per IS including compact insulated bus bar and rounded neutral bar, door earthing complete double door surface/reccess mounting IP-43 protection of L&T Cat No DBVTL004GD or equivalent in Legrand/Siemens.,Complete all as specified & as directed by Engineer-In-Charge.
S&F MCCB TP ,Thermal magnatic with enclouser , 415 Volts,50 HZ, 30 KA, 100 Amps DU-100H Cat No CM9789400k2 of L&T or equivalent Model of Legrand, Siemens.,Complete all as specified & as directed by Engineer-In-Charge.
Supply & Fix in repairs MCB TP 32 Amps 415 volts 50HZ of Legrand Cat No 4086 58 or equivalent in L&T /Seimens. ,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair PVC rectangular board 100 mm x 100 mmx 50 mm deep. Make : Press Fit or equavelent ,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair PVC rectangular board 175mm x 100mmx50mm deep. Make : Press Fit or equavelent.,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair PVC rectangular board 200mmx150mmx50mm deep. Make : Press Fit or equavelent.,Complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair PVC rectangular board 250mmx200mmx50mm deep. Make : Press Fit or equavelent .
Repair of Point wiring with 1.5 Sqmm (nominal area) PVC ( FRLS) insulated sheathed copper stranded conductor cable run inconcealed in PVC conduit/ in PVC cassing capping as reqd at site with all fittings such as bends, tee, junction boxes,etc with suitable size of 1.5 Sqmm PVC(FRLS) insulated copper earth continuity conductor connected to common earth dolly for one light/fan/call bell point complete all as specified and as directed by Engr -in -Charge. Note - Cutting and making good of chasis in wall/roof/floor is included in the qtd rates.
Supply and fixing CRYSTA LED Glass T8 tube rod with in built driver Double sided connection. 1x20 Watt (Double sided connection) (4 ft) . Make - Crompton Cat NoLGT8- 20-865-2 or Havells/Bajaj.
Supply and fix in repair POLARIS NIO- I 36W LED 5700K Ultra modern recess mounting luminare suitable for armstrong/ grid/ POP ceiling complete with separate electronic driver & high brightness SMD LEDs, complete with connecting accesseries & Driver duly pre-wired and connecting up with 0.5 Sqmm 3 core flexible Copper cable cord from fitting, complete all as specified and directed by Engineer-in-charge. MAKE : CROMPTON , Model No. LCTLRNE-36-FO-CDL or equivalent in Bajaj/HAVELLS.
Supply and fix in repair decorative ultra slim square profile linear Light Linea lighting fixture extruded Aluminium channel in thermally conductive material, energy efficent ready to use pack 20W LED 6000K, complete all as specified and directed by Engineer-in-Charge. MAKE : Crompton, Model No. LDL-20-CDL or equivalent in Bajaj/ HAVELLS.
Supply and fix in repair decorative ultra slim square profile linear Light Linea lighting fixture extruded Aluminium channel in thermally conductive material, energy efficent ready to use pack 10 W LED 6000K, complete all as specified and directed by Engineer-in-Charge. MAKE : Crompton, Model No.LDL-10-CDL or equivalent in Bajaj/ HAVELLS.
Supply and fix in repair decorative ultra slim square profile linear Light Linea lighting fixture extruded Aluminium channel in thermally conductive material,, energy efficent ready to use pack 5W LED 6000K, complete all as specified and directed by Engineer-in-Charge. MAKE : Crompton, Model No..LDL-05-CDL or equivalent in Bajaj/ HAVELLS.
Servicing of Inverter single phase AC input 160 to 260 V and out put 230 + 1 % of capacity 5 KVA including making electric connection cost of replacement of any related part for smooth functioning of the inverter is deemed to be included under quoted rate,Complete all as specified & as directed by Engineer-In-Charge.
Servicing the low specific gravity batteries by way of replacement of electolyte/charging and testing ,Complete all as specified & as directed by Engineer-In-Charge.
Replacement of Unservicable Battery for Invertor 12 Volt/180 Ah flooded type Make : Exide Express/Bosch/Tata BP.
Taking down existing copper/aluminum existing point wiring (light/fan/socket or power points) complete (fittings such as switches,ceiling roses,pendents, regulators, sockets etc to be measured saperatly) incl wooden battens and conduct etc & removing material as directed complete all as specified and as directed by Engr-in-Charge.
M&L for Point wiring with 1.5 Sqmm (nominal area) PVC ( FRLS) insulated sheathed copper stranded conductor cable run in and including PVC casing caping as per IS with all fittings such as bends, tee,junction boxes,etc of suitable size including 1.5 Sqmm PVC(FRLS) insulated copper earth continuity conductor connected to common earth dolly and including PVC boxes for housing switches, sockets,fan regulators etc for one light/fan/call bell point controlled by one 1- way switch complete all as specified and as directed by Engr-in-Charge.
All as per item no 46 but for One 5 Amps socket point on same/below board with other switches.
All as per item no 46 but for One 5amps switch socket point independent.
Point wiring with 1.5 Sqmm (nominal area) PVC ( FRLS) insulated sheathed copper stranded conductor cable run in and including concealed in wall/floor PVC conduit not less than 20 mm as per IS with all fittings such as bends, tee,junction boxes,etc of suitable size including 1.5 Sqmm PVC(FRLS) insulated copper earth continuity conductor connected to common earth dolly and including MS/GI sunken boxes with modular inner & surface plate suitable for housing modular switches, sockets,fan regulators etc for one light/fan/call bell point controlled by one 1- way switch complete all as specified and as directed by Engr -in -Charge.
M&L for Point wiring with 2.5 Sqmm (nominal area) PVC ( FRLS) insulated sheathed copper stranded conductor cable run on surface in PVC cassing and capping of suitable size with all fittings such as bends, tee, junction boxes,etc of suitable size including 2.5 Sqmm PVC(FRLS) insulated copper earth continuity conductor connected to common earth dolly and including PVC boxes with plate for housing switches, sockets,fan regulators etc for one light/fan/call bell point controlled by one 1- way switch complete all as specified and as directed by Engr -in -Charge. Note - Cutting and making good of chasis in wall/roof/floor is included in the qtd rates.
All as per item no 49 but for One 5 Amps socket point on same/below board with other switches.
All as per item no 49 but for One 5amps switch socket point independent.
M&L for Point wiring with 2.5 Sqmm (nominal area) PVC ( FRLS) insulated sheathed copper stranded conductor cable run in and including concealed in wall/floor PVC medium grade conduit not less than 20 mm as per IS with all fittings such as bends, tee, junction boxes,etc of suitable size including 1.5 Sqmm PVC(FRLS) insulated copper earth continuity conductor connected to common earth dolly and including MS/GI sunken boxes with modular inner & surface plate suitable for housing modular switches, sockets,fan regulators etc for one light/fan/call bell point controlled by one 1- way switch complete all as specified and as directed by Engr -in -Charge. Note - Cutting and making good of chasis in wall/roof/floor is included in the qtd rates.
Supplying and fixing in repairs Modular white cover plate with frame, 3 Module, Make Legrand /Anchor Roma/Crabetree.
Supplying and fixing in repairs Modular white cover plate with frame, 6 Module, Make Legrand /Anchor Roma/Crabetree.
Supply & fix metal fiush mounting box 3 module.
Supply & fix metal fiush mounting box 6 module.
Supply & fix rigid non metelic PVC conduit not less then 20mm/Casing caping exclusive of boxes (junction/terminal) but inclusive of all tee,bends, elbow, reducer bell mount tube ends and fixing accessories such as coupler, lock nuts saddles, pipe hooks etc in surface in wall/celling/floor etc. complete all as specified & directed.
M&L wiring for circuit/ sub main wiring of 2x2.5 Sqmm + 1x2.5 Sqmm earth wire, alongwith earth wire PVC (FRLS) insulated copper conductor, single core, 1100 v grade cable in surface/concealed as required in PVC conduit complete all as directed by Engr -in- Charge.
M&L for wiring for circuit/ sub main wiring of 2x2.5 Sqmm + 1x2.5 Sqmm earth wire, alongwith earth wire PVC (FRLS) insulated copper conductor, single core, 1100 V grade cable in PVC cassing capping / PVC conduit of suitable size on surface wiring complete all as specified & as directed by Engineer-in-Charge.
M&L wiring for circuit/ sub main wiring of 2x4 Sqmm + 1x4 Sqmm earth wire, alongwith eart wire PVC (FRLS) insulated copper conductor, single core, 1100 v grade cable in surface/ recessed as required in PVC casing caping complete all as directed by Engr -in- Charge.
M&L wiring for circuit/ sub main wiring of 2x6 Sqmm + 1x6 Sqmm earth wire, alongwith eart wire PVC (FRLS) insulated copper conductor, single core, 1100 v grade cable in surface/ recessed as required in PVC casing caping complete all as directed by Engr -in- Charge.
supply,install,testing and commissioning of indoor type cbical metering panel board outer shell made out of 2 mm thick MS sheet of size not less than 900X900XX300 mm and MS angle iron frame size 50x50x6 mm mounted on Wall/Floor withsuitable size of nut, bolt and washer , frame factory fabricated withfront openable 3 phase , 4wire 415 volt, 50 Hz, including taking down old existing electric meter and refixing the same in new metering panel incl all electrical connections complete all as specified and directed by Engr-in-charge and compriseing with following TPN aluminium bus bar 200 Amp insulated with colour coded heat shhrikable sleeve and shall be mounted on suitable size 'F' class insulators Incoming MCCB 63 Amps 16 KA ,415 Volts, 50 Hz, FP-01 No Out going MCB SP 40 Amp-04 No Space for installation of electric meter-04 No LED Indicating lamp -01 set of three
Disconnecting all existing electric supply and taking down carefully ceilling/ exhaust/cabin/wall fan of any make and sweep dismantlling blades, checking for repairs required ( Note: Repairs/ Replacement of spares shall be carreied under appropriate items. for C/fan, Exhaust fan . The item will be taken down and brought to MES yard for repairs, i.e overoiling,rewinding,replacement of bush/bearing, brazing/machine work, painting and after testing at MES store yard Cost for transportation from site to MES store yard & vice versa is deemeed to be included under the quoted rate.
Hanging/fixing only ceiling fans of any make and sweep connecting the complete with & including provision of copper conductor cord 3 core PVC insulated and sheathed 0.5 Sqmm from ceiling rose to exhaust fan connector and testing as directed and specified( Note: The exhaust fan shall be fitted with new set of clamps, rubber shackle split pins and top and bottom nut bolts etc.)
Hanging/fixing only exhaust/cabin/wall fan of any make or sweep connecting up complete with and including provision of copper conductor cord 3 core PVC insulated and sheathed from celing rose to fan connector & testing as directed and specified. ( Note: The Exhaust fan shall be fitted with new set of washers, nuts, rubber packing etc.)
M & L for Opening up of fan, motor of fan, cleaning stator,rotor, cleaning of all parts greasing oiling of bushes and bearing reassembling and testing for smooth functioning for celling fan 1200 mm sweep Note;-rate shall be quoted for taking down & refixing of ceiling fn afterrepair work
All as per item No 67 but for Exhaust fan 300/375/450mm sweep
All as per item No 67 but for Table/pedastal fan/Air circulator fan 400 /600/750 mm sweep
M & L for removing the burnt winding and rewinding the fan with super enamelled copper winding wire of suitable gauge, insulating, putting sleeves etc complete all as specified and directed by Engineer-in-Charge for celing fan 1200 mm sweep
All as per item No 70 but for Exhaust fan 300/380 mm sweep
All as per item No 70 but for Exhaust fan 450 mm sweep
All as per item No 70 but for Table/pedastal fan/Air circulator fan 400 /600/750 mm sweep
Supply only bearing in repairs or replacement for celing fan 1200 mm sweep
All as per item No 74 but for Exhaust fan/Air ciculator fan 300/400/450/650/750 mm sweep
Supply only gun metal bush in repairs or replacement forceling fan 1200 mm sweep
All as per item No 76 but for Exhaust fan of any type
All as per item No 76 but for Table/pedastal fan/Air circulator fan 400 /600/750 mm sweep
S&F in repairs Fan capacitor 2.5 MFD, 250 V.
S&F in repairs capacitor 4.0 MFD, 250 V Heavy duty.
Suppy & fixing only gear assembly of table/wall mounted/air circulator/ pedastal fan suitable for easy air circulatig movements of any size of fan
Supply and fixing in replacement fan motor suitable for PCV exhaust fan 230/300 mm complete Note;-rate shall be quoted for taking down & refixing of exhaust ceiling fn afterrepair work
S&F fan clamp assembly consisting of nut, bolts, washers and split pin alongwith suitable size rubber real for mounting of fan down rod.
M&L for down rod 1000 mm long for ceilling fan of any make and sweep made out of medium grade GI tubing 15 mm dia duly painted with two coats of enamel paint and provision of holes for electric wire at top and bottom also arrangemnts for fittment of ceiling fan motor,clamp assembly and condensor all specified and directed by Engineer in charge
All as per item No 84 do but 1500 mm
M&L for Machine work such as fan hook,FI clamps, nuts, bolts, washers etc duly painted complete all as specified & directed by Engineer-in-Charge.
S&F copper flexible twin twisted cable of size 23/ 0.0076 .
Taking down ceiling 1200/1400 mm fan at site by disconnecting all electrical connection, dismantling blades, scraping down old paint , rust, dirt, grease etc cleaning and preparation of motors and blades surfaces, and spray painting with two coats of approved apcolite enamel paint over all as directed by Engr-in-charge.
Taking down Exhaust fan 300/ 380mm at site by disconnecting all electrical connection, dismantling blades, scraping down old paint , rust, dirt, grease etc cleaning and preparation of motors and blades surfaces, and spray painting with two coats of approved apcolite enamel paint over all as directed by Engr-in-charge.
Taking down Exhaust fan 450 mm at site by disconnecting all electrical connection, dismantling blades, scraping down old paint , rust, dirt, grease etc cleaning and preparation of motors and blades surfaces, and spray painting with two coats of approved apcolite enamel paint over all as directed by Engr-in-charge.
S&F louver complete for exhaust fan of size 300mm , made of iron/ aluminium (As Sample approved ) of matching colour with exhaust fan of suitable size ,duly grauted bolts in the wall fixed with nuts, bolt and washers and making good the plastering by matching colour with existing colour to the disturbed surface of wall complete
All as per item no 91 but for exhaust fan of size 380mm.
All as per item no 91 but for exhaust fan of size 450mm.
Disconnecting carefully water and electric connection from geyser, taking down carefully storage type water heater of any type and capacity and dismantling geyser by removing glass wool, thermostat, heating element for checking of defects, repalcement of defective thermostat, heating element of any capacity, indicating lamps (round/rectangular) flange assembly, top or bottom cover half round plate glass wool etc where required, cleaning of inner container by anti corrosive liquid removing scales repair by brazing, Re-assemblong of geyser and refixing at its original location and testing complete(Replacement of spares such as heating element , thermostat, indicating lamp, top and bottom cover, half round plate, glass wool heating flange assembly will be measured and paid under relevent items) all as directed
M&L for replacement of heating assembly (flange) made out of copper/steel as existing including heat resistance and leak proof gasket suitable for 25 ltrs capacity geyser all as directed Make : Ditzs/ Racold/ Shakti/Spheroat
All as per item No 95 above but for 35/50 lts capacity
S & F Power Board suitable for 50/35/25 Ltr Digital Square water heater /geyser as per sample Make : Jaquar or equilivalent
S&F in repair thermostat having range 0 to 100 C for geyser as original size of 25/35/50ltrs capacity geyser sutiable for Ditzs/ Racold/ Shakti/Spheroat Make.
S&F in repair heating element 2 KW with round or triangular base for 50 ltrs capacity geyser sutiable for Ditzs/ Racold/ Shakti/Spheroat Make.
S&F in repair heating element 1.5 KW with round or triangular base for 35 ltrs capacity geyser sutiable for Ditzs/ Racold/ Shakti/Spheroat Make.
S&F in repair heating element 1 KW with round or triangular base for 25 ltrs capacity geyser sutiable for Ditzs/ Racold/ Shakti/Spheroat Make.
S&F in repair lamp indicator with red colour 230 volts complete with fixing arrangement round or rectangular shape and size as per existing geyser suitable for Ditzs/ Racold/ Shakti/Spheroat Make.
S&F in repair cord flexible 230 volts 3 core 2.5 sqmm copper conductor PVC insulated and sheated cable from geyser to power point to each geyser all as directed
S&F in repair bottom cover made out of MS sheet of suitable size and gauge as existing for 25/50 ltrs capacity geyser including necessay fixing screws, washers, nuts and bolts of suitable size as as directed suitable for Ditzs/ Racold/ Shakti/Spheroat
S&F in repair top cover made out of MS sheet of suitable size and gauge as existing for 25/50 ltrs capacity geyser including necessay fixing screws, washers, nuts and bolts of suitable size as as directed suitable for Ditzs/ Racold/ Shakti/Spheroat
S&F in repair over load safety release valve ISI marked suitable for 25/50 ltrs capacity geyser including necessay fixing screws, washers, nuts and bolts of suitable size as as directed suitable for Ditzs/ Racold/ Shakti/Spheroat
Taking down geyser 25/50 ltrs at site by disconnecting all electrical connection, prepairing the old painted surface of geyser body and type and size with wire brusheds, sand paper and applying one coat of white synthetic enamel paint by spraying including marking MES No with black paint in 3 cm high block letters complete all as directed
S&F in repair non return valve 15mm dia heavy duty and fixing on original position of geyser all as directed and confiring ot IS suitable for geyser Make : Ditzs/ Racold/ Shakti/Spheroat
S&F in repair glass wool superior quality around the water container as heat resistance upto full capacty all as drected suitable for geyser Make : Ditzs/ Racold/ Shakti/Spheroat
Supply and fix 15mm dia bor plug type bib taps, cast iron, screwed for iron pipe and fixed.etc all as specified and directed.Make- ISI.
S&F in repair stop valve cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for 15 mm bore iron pipe on existing position for geyser Make : Ditzs/ Racold/ Shakti/Spheroat
S&F in repair new galvanised steel water tubing 15 mm dia medium grade including all necessary new GI fittings and fixed complete to wall from tank to geyser in let/out let all as specified and as directed by Engineer-in-Charge for geyser Make : Ditzs/ Racold/ Shakti/Spheroat
DIAMOND ENTERPRISES
YASHRAJ ELECTRICALS
SHRI SULAI ELECTRICALS
MAHIMA CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .