Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.8 LAccepted-AOC | ₹42.8 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹45.2 L+₹2.4 L (5.57%)Rejected-Finance | ₹45.2 L+₹2.4 L (5.57%) | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹46.1 L+₹3.2 L (7.52%)Rejected-Finance | ₹46.1 L+₹3.2 L (7.52%) | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹46.7 L+₹3.8 L (8.94%)Rejected-Finance | ₹46.7 L+₹3.8 L (8.94%) | L4 | Rejected-Finance Other than L1 |
| 5 | L5₹46.7 L+₹3.9 L (9.09%)Rejected-Finance | ₹46.7 L+₹3.9 L (9.09%) | L5 | Rejected-Finance Other than L1 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
5 Sept 2024, 6:00 pmClosed
GE (AF) Pathankot
GE (AF) Pathankot
REPAIR TO RCC ROOF, WATER PROOFING TREATMENT AND REPAIR REPLACEMENT TO FLOORING, PLASTERING WALL, SEEPAGE PLUMBING, SANITARY FITTING, FALSE CEILING AND JOINERY TO CERTAIN BUILDINGS IN NO 02 AND 03 AREA AT AIR FORCE STATION PATHANKOT
2024_MES_666144_1
GE/PAF-32/2024-25
Open Tender
Civil Works
Item Rate
180 days
GE (AF) Pathankot
As per NIT
7 documents required · 7 mandatory
₹500
GE (AF) Pathankot
₹90,000
Yes
4 Dec 2024
16 Jul 2024
12 Sept 2024
16 Jul 2024
5 Sept 2024
30 Jul 2024
Amount
Material and labour for preparation of surface by scrapping and properly cleaning the existing surface by removing loose/uneven particles with wire brushes and other tools complete in all respect. Existing surface can be of mudphuska, old APP membrane, brick tiles etc. Filling the cracks with PU sealent wherever required. Plastering whever required shall be measured and paid separately. Proper curing of plastering to be ensured before further application. Apply first coat Fibre reinforced elastomeric liquid water proofing membrene formulated with PU hybrid polymers and reinforcing acrylic fibres with Sun Reflective Index (SRI) of 100-110, having minimum elongation of 350%, tensile strength 2.9Mps and shall have crack bridging ability upto 2.5 mm and shall resist 10 bars of hydrostatic pressure reduce surface temperature upto 10 degree celcius with 33% dilution as priming coat. Laying fibre mesh of 0.3mm thickness weave in leno pattern having weight 45 gm/Sqm and pasting it properly with overlap of 50mm and allow it to dry. Apply second undiluted coat @ 0.450 Ltr/sqm . Apply third and final coat undiluted @ 0.450 Ltr/Sqm complete all as specified and directed by Engineer-in-charge. Note : (a) Application of water proofing treatment will be done by Authorised Applicator only/or in presence of authorised rep . Certificate in this regard shall be submitted to Engineer-in-Charge. (b) Shifting/removing of of any wire/cable/AC unit or other any object as per site requirement and re-fixing the same if needed is deemed to be included in the rate quoted by the contractor. (c) Total removal of vegetation/creepers//small plants/roots from the top of the bldgs to facilitate the work of treatment is also deemed to be included in the rate of contractor. (d) Rep of approved firm shall visit during the execution and a certicate " that work is carried out as per their standard/ specification be submitted to Engineer-in-charge.
All as per Srl item No 01 above but in patches near spout area not Exceeding 10.00 sqm complete all as specified and directed by Engineer-in-charge
Material and labour for 10mm thick cement rendering in cement mortar 1:3 and finishing the surface even and smooth before application of primer coat complete all as specified and directed by Engineer-in-charge.
Material and labour for providing cement concrete type B1, 1:2:4 (20mm graded crushed stone aggregate) set in cement mortar 1:4 in coping , kneelers and in similart works including necessary form work complete all as specified and directed by Engineer-in-charge.
Demolition of brick work stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed by Engineer-in-charge.
Material and labour brick work with sub class B bricks straight or curved on plan 6m mean radius built in cement mortar 1:6 complete all as specified and directed by Engineer-in-charge.
All as per item No 4 above but except bricks complete all as specified and directed by Engineer-in-charge
Rendering dubbing coat over damaged irregular surface of chajjas roof projections ceiling facia etc average 15mm thick in cement mortar 1:4 over cement slurry coat thick @ 3 Kg/sqm making the surface even followed by 5mm thick rendering in cement mortar 1:3 furnished even & smooth including applying two coats of weather proof emulsion paint including making of drip course as required complete including roughening surface of old concrete by picking sweeping clean and washing with water all as specified. Note :Rate for form work if required to be including in the rate quoted by the contractor complete all as specified and directed by Engineer-in-charge.
Disconnection existing water tanks of capacity exc 250Ltr and not exc 500 Ltr, settting aside (or lowering if required) for repairs, cleaning of tanks, etc and hoisting if required reconnecting and re fexing in the same position complete all as specified and directed by Engineer-in-charge.
Disconnection existing water tanks of capacity exc 500 Ltr and not exc 1000 Ltr, settting aside (or lowering if required) for repairs, cleaning of tanks, etc and hoisting if required reconnecting and re fexing in the same position complete all as specified and directed by Engineer-in-charge.
Supply and fixing rotational moulded polyethene water storage tanks of capacity 500 litres, (cylindrical vertical with closed top) hoisted and fixed in position including S & F necessary GI fittings, inlet/outlet washout, overflow pieces long nipples, checknuts & washer ,brass valve 20mm high pressure with polythene float and fly nut etc complete including dismantling existing water tank complete all as specified and directed by Engineer-in-charge.
Supply and fixing rotational moulded polyethiene water storage tanks of capacity 1000 litres, (cylindrical vertical with closed top) hoisted and fixed in position including S & F necessary GI fittings, inlet/outlet washout, overflow pieces long nipples, checknuts & washer ,brass valve 20mm high pressure with polythene float and fly nut etc complete including dismantling existing water tank complete all as specified and directed by Engineer-in-charge.
Supply and fixing in repair 15mm bore tubes medium grade galvanized ISI marked with all fittings short pieces and fixed complete to walls, floor, ceiling etc all including taking down existing G I tubing complete all as specified and directed by Engineer-in-charge.
All as per Srl item No 13 here-in-before, but fixing only complete all as specified and directed by Engineer-in-charge
Supply and fixing in repair 20mm bore tubes medium grade galvanized ISI marked with all fittings short pieces and fixed complete to walls, floor, ceiling etc all incl taking down existing G I tubing complete all as specified and directed by Engineer-in-charge.
All as per Srl item No 15 here-in-before, but fixing only complete all as specified and directed by Engineer-in-charge.
Taking down cement plaster of any decription on brick work or concrete surfaces incl. raking out joints,hacking for key, scrubbing down with water etc and removing same from the sites complete all as specified and directed by Engineer-in-charge.
Material and labour Rendering 15mm thick cement plaster on faces of brick work or concrete surfaces in cement mortar (1:6) finished even and fair without using extra cement complete all as specified and directed by Engineer-in-charge.
Material and labour for 15mm thick cement plaster in cement mortar 1:4 on bricks or concrete surfaces finishing the surfaces even and smooth without using extra cement complete all as specified and directed by Engineer-in-charge. Note :Rate for form work if required to be included in the rate quoted by the contractor.
Rendering 15mm thick on fair/unfair faces of brick work or on stone, concrete surfaces in cement mortar 1:4 in any position and in patches of area not exc 3 Sqm including taking down exisitng plastering and matching the surface with existing complete all as specified and directed by Engineer-in-charge.
Applying 3mm thick white putty on wall surfaces and rubbing the surface even and smooth complete all as specified and directed by Engineer-in-charge.
Material and labour for preparation of plastered or unplastered old/new surfaces by brooming down or steel wire brushing, scrapping down smoke soot , moulds moss and efflorosent salts , trading oil and greasy spots and applying two coats of oil bound distemper, complete all as specified and directed by Engineer-in-charge.
Material and labour for preparation of newly plaster surfaces of wall and projection and applying two coats of acrylic exterior emulsion paint as approved of any shade/colour in camouflage pattern over a coat of primer including preparation of surfaces as per manufacture instructions complete all as specified and directed by Engineer-in-charge.
Taking down shutters of any description exc 1 sqm and n exc 2 sqm each complete all as specified and directed by Engineer-in-charge
Taking down chowkhat or frame with shutter (without taking off shutter from the frame) n exc. 1.50 Sqm each incl taking out hold fast complete all as specified and directed by Engineer-in-charge.
Taking down chowkhat or frame with shutter (without taking off shutter from the frame) exc. 1.50 Sqm but n exc. 4 Sqm each complete all as specified and directed by Engineer-in-charge.
Material and labour pressed steel frame made out of MS sheet 1.25mm thick of size 125x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc including filling of concrete 1:3:6 type C-1 back of chowkats,with two coats of synthetic enamel paint over one coat of red oxide primer including taking down with existing one complete all as specified and directed by Engineer-in-charge.
Material and labour pressed steel frame made out of MS sheet 1.25mm thick of size 105x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc including filling of concrete 1:3:6 type C-1 back of chowkats,with two coats of synthetic enamel paint over one coat of red oxide primer including taking down with existing one complete all as specified and directed by Engineer-in-charge.
Supply and fixing factory made solid PVC door frame single rebated of size 60 x 30mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100x8 sheet metal counter sunk head screws taking down with existing one complete all as specified and directed by Engineer-in-charge.
Supply and fixing 35mm thick factory made plain framed panelled door shutters of 2nd class hard wood two panel with lock rail and panel of 9mm thick BWP commercial ply ,the size of rail and style as per IS : 1003 Part-I, Kiln seasoned and chemically pressure treatedfactory made shutters wood is to be incorporated complete all as specified and directed by Engineer-in-charge.
Material and labour for providing and fixing factory made single extruded WPC (wood polymer composite) solid decorative type flush door shutter of size 35mm thick comprising of virgin polymer of K value 58-60( suspension grade), calcium carbonate and natural fibres( wood powder/ rice husk/ wheat husk) and non toxic additives( maximum toxicity index of 12 for 100gms) having minimum density of 650kg/cum and screw withdrawal strength of 1800N (Face) & 900N (Edge), minimum compressive strength 50N/mm2, modulus of elasticity 850N/mm2 and resistance to spread of flame of class A categary with property of being termite/ borer proof, water/ moisture proof and fire redardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter shank S.S screwescomplete all as specified and directed by Engineer-in-charge.
Supply and fixing 2nd class hard wood 35 mm thick factory made glazed and skeleton shutters open rebated and prepared to rceieve glass, gauze,etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass,etc, size of members of shutters as spfd in SSR Part-1, Section 8, clause 8.24 (a) complete all as specified and directed by Engineer-in-charge.
Supply and fixing factory made Flush door of 35 mm thick ,solid core construction with particle board core :- All screws shall be self tapping chrome plated complete all as specified and directed by Engineer-in-charge.
Supply and fixing factory made PVC Flush door of 28 to 30mm thick(stiles) with 2, 4 or 6 raised pannel design with 5 mm thick moulded prelam PVC sheet on the front face and 5mm thick panel colour PVC sheet on back face complete all as specified and directed by Engineer-in-charge.
Supply and fixing Factory made Steel window 1.25mm thick box type(primer coated)ERW hollow P section of size 60mmx25mm including grill using 10 sqmm bar double rebated both gauge and glass shutter comprised gauged glazed Skelton shutter ERW sec 50mmx20mm and 1mm thick with two openable leaf consisting two Nos sash bar of T Section 20mmx3mm complete welded to frame with one vertical mullion of ERW box type T Section of size 60mmx25mm and 1.25mm thick including cutting holes and making good dismantled portion in PCC(1:2:4) type B1 four Nos for each window including following fitting welded to frame shutter :(a) Hold fast,150mm long of 12mmx3mm made to shape O4 Nos per window (b) handle of Z Sec20mmx25mm, 100mm long-per No leaf (c) Stainless steel Tower bolt 150mm long-02No per leaf .(d) Z section 20mmx25mm, 100mm long stopper 1 No per leaf. (e) cleat 55mm long of hollow square 15mmx20mmx63mm welded to hinge. 1 No per leaf (f) MS Pintal hinges of size 75mmx12mm. 2 Nos per leaf, including Stainless steel wire cloth, 0.25 mm to 0.36mm nominal dia of wire & average width of aperture 1.40mm to 2mm & fixed with alluminium wire staples and glass pane 3mm thick fixed with MS pin and oil putty including two coats of synthetic enamel paint including. taking down existing windows complete. NOTE:- During Fixing of Window, surface Shall be make good in plumb with existing finishes like cement plaster ,similar wall tile,floor tile etc and as per site requirement.
Supply and fixing Factory made Ventilator 1.25mm thick box type(primer coated)ERW hollow P section of size 60mmx25mm including grill using 10 sqmm bar double rebated both gauge and glass shutter comprised gauged glazed Skelton shutter ERW sec 50mmx20mm and 1mm thick with two openable leaf consisting two Nos sash bar of T Section 20mmx3mm complete welded to frame with one vertical mullion of ERW box type T Section of size 60mmx25mm and 1.25mm thick including cutting holes and good dismantled portion in PCC(1:2:4) type B1 four Nos for each window including following fitting welded to frame shutter :(a) Hold fast,150mm long of 12mmx3mm made to shape O4 Nos per window (b) handle of Z Sec20mmx25mm, 100mm long-per No leaf (c) MS Tower bolt 150mm long-02No per leaf .(d) Z section 20mmx25mm, 100mm long stopper 1 No per leaf. (e) cleat 55mm long of hollow square 15mmx20mmx63mm welded to hinge. 1 No per leaf (f) MS Pintal hinges of size 75mmx12mm. 2 Nos per leaf, including Stainless steel wire cloth, 0.25 mm to 0.36mm nominal dia of wire & average width of aperture 1.40mm to 2mm & fixed with alluminium wire staples and glass pane 3mm thick fixed with MS pin and oil putty including two coats of synthetic enamel paint including. taking down existing ventilator complete. NOTE:- During Fixing of Window, surface Shall be make good in plumb with existing finishes like cement plaster ,similar wall tile,floor tile etc and as per site requirement. NOTE:- During Fixing of Ventilator, surface Shall be make good in plumb with existing finishes like cement plaster ,similar wall tile etc and as per site requirement.
Preparaption of new wooden surfaces of any description not otherwise described, over 10 cm width or girth and providing two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engineer-in-charge.
Preparation of old/new steel surfaces of any description over 10cm width or girth, not otherwise desccribed applying two coats of synthetic enamel paint complete all as specified and directed by Engineer-in-charge.
Supply and fixing stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stailess steel wire staples complete all as specified and directed by Engineer-in-charge.
Supply and fixing 100mm long (12Gauge) butt hinges stainless steel anodised and fixed complete all as specified and directed by Engineer-in-charge. NOTE :- All screws shall be self tapping chrome plated and length of screw not less 38 mm
Supply and fixing Stainless steel sliding door bolts, plate type, with bright bolt not lesss than 10mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate 300mm long complete all as specified and directed by Engineer-in-charge.
Supply and fixing Stainless steel Tower Bolt of 200 mm long fixed with Self Tapping screws complete all as specified and directed by Engineer-in-charge.
Supply and fixing Stainless steel Tower Bolt of 150 mm long fixed with Self Tapping screws complete all as specified and directed by Engineer-in-charge.
Supply and fixing Stainless steel Handel of 150 mm long fixed with Self Tapping screws complete all as specified and directed by Engineer-in-charge.
Material and labour Granite (of any type), 18- 20mm thick (table rubbed and polished) in steps, jambs, pillars, window cills,cooking platform and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixer of pigment to match with marble shade including making full curving the edges and dismantling existing floor complete all as specified and directed by Engineer-in-charge.
Material and labour Machine cut kota stone slab 18-20mm thick as in flooring, over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing including 15mm thick cement screed bed in cement mortor 1:4 and dismantling existing floor complete all as specified and directed by Engineer-in-charge.
Demolition of plain cement Concrete as in sunken, roof, floors (other than ground floors)beams stair case, landings, chajjas and similar suspended work of any thickness including. removing lean concrete/red bajri/moorum & cleaning the surface complete all as specified and directed by Engineer-in-charge.
15mm thick plaster in cement mortar (1:4) using water proofing compound @3% by weight of cement on the floor and sides of wall of sunken portion and finished the surface even & smooth using extra cement complete all as specified and directed by Engineer-in-charge.
Supply and fixing Doctor fixit Pidifin 2k high performance 2 component flexible Acrylic polymer modify cement base water proofing coating in two coat 1mm thick dry film mixed in ratio 2:1 by weight or 1.5:1 by volume product of M/S Pidilite Industry Limited Makers of Fevicol adhesive brand complete all as specified and directed by Engineer-in-charge.
Material and labour PCC 1:4:8, type D-2, (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete, (as in sunken floor) complete all as specified and directed by Engineer-in-charge.
Supply and fixing in repair GI spout pipe medium weight 50mm bore dia of length 450mm set in PCC 1:4:8 porous concrete and make the external portion with cement mortar 1:3 with and including water proofing @200ML per bag complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement 100mm/75mm bore cast iron floor trap with CP grating including jointing to waste pipe fixed in cement concrete type B-1, 1:2:4, complete all as specified and directed by Engineer-in-charge.
Supply and fixing in repair Vitreous china squatting pan of patern 'Orissa pattern ' size 580x440 mm white with integral foot rests (Excluding flushing cistern and flush pipe), including long arm 'P'-trap 100mm dia (PTMT) with PVC pipe 110mm bore length upto 700mm or as per site requirement, complete including making good to floor complete all as specified and directed by Engineer-in-charge.
Supply and fixing in repair 10 ltr capacity PVC valveless syphonic action type flushing cistern low level white with inlet ball valve float ovel handle incl brackets and PVC flushing pipe of polyethylene of low or high density or PVC 32mm dia complete all as specified and directed by Engineer-in-charge.
Dismantling false ceiling any type, any thickness complete all as specified and directed by Engineer-in-charge.
Material and labour Position suspended false ceiling system using T-grid suspended ceiling grid system. The size of grid shall be 600 x 600mm with GI frame work main runner 38 x 24mm x 3600 mm, cross tee 25 x 24 x 600mm / 25 x 24 x 1200mm and wall angle 24 x 24 x 2540mm ( thickness of the material of 0.30 mm), using 9mm thick ceiling panel laminated with PVC film on front face and foil back available in due drop texture as per IS-2095, part-I-1996, fixed in the grid of T-grid suspended ceiling grid system duly suspended by 4mm dig GI bar hanger from the purlins of the roof with butter fly clips complete all as specified and directed by Engineer-in-charge.
Supply and fixing Position suspended false ceiling using 9mm thick ceiling panel (600mm × 600mm) laminated with PVC film on front face and foil back available in due drop texture as per IS-2095, part-I-1996, fixed in the grid of T-grid suspended ceiling grid system duly suspended by 4mm dig GI bar hanger from the purlins of the roof with butter fly clips complete all as specified and directed by Engineer-in-charge.
Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in cement mortar 1:6 including dismantling/demolition on same existing floor complete all as specified and directed by Engineer-in-charge.
Material and labour Chequered cement concrete tile 20cm x 20cm x 25mm thick with grey cement and pigments set jointed and pointed in neat cement slurry over 15mm thick screed bed in cement mortar 1:6 including dismantling/demolition on same existing floor complete all as specified and directed by Engineer-in-charge.
Material and labour non-skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11sqm but not exceeding 0.18 sqm as in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the tiles including 15mm thick screed bed or bedding layer in cement mortar 1:4 and dismantling/demolition on existing surface complete all as specified and directed by Engineer-in-charge.
Material and labour glazed ceramic coloured tiles of size 450 x 300 x 7mm thick, on vertical surfaces of walls such as skirting dado etc. set and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thick rendering in cement mortar 1:4 and dismantling existing floor tiling complete all as specified and directed by Engineer-in-charge.
A R ENTERPRISES (BID ID -3083950)
pardeep singh marwaha (BID ID -3084463)
INDERJIT SINGH (BID ID -3083553)
Surya & Gautam Builders (BID ID -3086697)
M/S SOHAL CONSTRUCTION CO (BID ID -3085780)
M/S G P MARWAHA (BID ID -3086609)
Auto India (BID ID -3083914)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .