| Sl No | Description | Qty | Unit | Shree Karni Electrovision L2 | M/S STEADFAST ENTERPRISES L1 |
|---|---|---|---|---|---|
| 1.00 | Excavation in trenches n.exc 1.5 metre wide and n.exc 1.5 metre in depth for foundation etc or for laying of cable etc and getting out in soft/loose soil complete all as specified and directed. | 9.5 | Cum | 650 ₹6,175 | 100 ₹950 Lowest |
| 2.00 | Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 Cm in depth complete all as specified and directed. | 5.7 | Cum | 450 ₹2,565 | 70 ₹399 Lowest |
| 3.00 | Removing of excavated material (soil) to a distance n.exc 50 metre and depositing where directed at a level n.exc 1.50 metre above the starting point complete all as specified and directed. | 3.8 | Cum | 400 ₹1,520 | 70 ₹266 Lowest |
| 4.00 | M&L for Sand cushioning to PVC under ground cable with tibba sand and punning to provide a required cover complete all as specified and directed. | 2.8 | Cum | 3,500 ₹9,800 | 1,000 ₹2,800 Lowest |
| 5.00 | M&L for Bricks for protection cover to under ground cable (with old size sub class ‘B’ bricks) with width equal to length of brick laid dry and flat abutting each other with gaps between adjacent brick not exceeding 10mm complete all as specified and directed. | 0.25 | Per 1000 Nos | 8,000 ₹2,000 | 4,000 ₹1,000 Lowest |
| 6.00 | Supply, Laying, Jointing, testing & commissioning LT under ground cable XLPE insulated, screened PVC bedded, galvanised steel strips or wire armoured, heavy duty with multi stranded aluminium conductor, 95 Sqmm, 3½ core cable, 1100 volts grade (ISI marked) laid in trenches, ducts, pipes or fixed on pole etc complete all as specified and directed. | 70 | RM | 1,400 ₹98,000 | 350 ₹24,500 Lowest |
| 7.00 | S&F rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) capacity 500 ltrs hoisted and fixed in position all as specified in SSR Part-I complete with necessary fittings as reqd on site complete all as specified and directed. | 1 | Each | 15,000 ₹15,000 | 13,000 ₹13,000 Lowest |
| 8.00 | M&L for galvanised steel tubes 25 mm dia "medium grade " (ISI marked) with all fitting( ISI marked) and fixed complete to walls and ceilings or laid in floors/trenches and under road, complete all as specified and directed. | 10 | RM | 650 ₹6,500 | 300 ₹3,000 Lowest |
| 9.00 | M&L for gun metal gate valve/forged valve 25 mm bore with iron wheel head, screwed both ends for jointing iron pipes, non rising, forged brass spindle class-1, IS-778 marked complete all as specified and directed. | 1 | Each | 4,500 ₹4,500 | 1,000 ₹1,000 Lowest |
| 10.00 | Shifting, install, testing and commissioning (CPRI type test certified) LT Panel out door type IP-54, floor mounted,compartmantalised and suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, all as specified and directed, The panel shall be dust and vermin proof, made of 3.15mm CRCA MS sheet and with base frame of 40x40x6mm angle iron , powder coated, having front and rear openeable hinged double door shutters with aprons for cable entry and locking arrangement complete with following accessoies complete.
Incoming
(a) MCCB 200 amps, 4 pole, 35/36 KA with adjustable thermal over load release with earth fault protection. 50 Hz, 415 volts grade - 01Nos.
(b) Bus bar electrolytic grade copper 600Amp, 4 pole , not less than 100cm long mounted on insulators- 01 No.
(c) LED indicating lamps (R, Y & B) -01 Set.
(d) Digital voltmeter Ammeter with CT PT according to Capacity of Load of main panel including selector switch
Outgoing
(a) MCCB 100 amps, 4 pole, 25 KA with adjustable thermal over load release with earth fault protection. 50 Hz, 415 volts grade - 02Nos. | 1 | Each | 32,000 ₹32,000 | 20,000 ₹20,000 Lowest |
Tender Value
₹9.1 L
EMD Value
₹18,200
Closing Date
18 Mar 2026, 6:00 pmClosed
CWE JAIPUR
Military Engineer Services, HQ Commander Works Engineer, KalyanMarg, Banipark, Jaipur-06
PROVN OF SHIFTING OF 02 X 10 TON PRECISION AIR CONDITIONING (PAC) FROM ZONAL CENTRE JAIPUR TO BLDG NO P-36 NFS NODE AT JAIPUR MIL STN
2026_MES_754176_1
82546/JPR(S)/E8
Open Tender
Civil Works
Item Rate
180 days
GE SOUTH JAIPUR
AS PER NIT
6 documents required · 6 mandatory
₹500
GE (S) JAIPUR
₹18,200
Yes
HQ CWE JAIPUR
22 Apr 2026
25 Feb 2026
20 Mar 2026
25 Feb 2026
18 Mar 2026
12 Mar 2026
5 Mar 2026
Excavation in trenches n.exc 1.5 metre wide and n.exc 1.5 metre in depth for foundation etc or for laying of cable etc and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 Cm in depth complete all as specified and directed.
Removing of excavated material (soil) to a distance n.exc 50 metre and depositing where directed at a level n.exc 1.50 metre above the starting point complete all as specified and directed.
M&L for Sand cushioning to PVC under ground cable with tibba sand and punning to provide a required cover complete all as specified and directed.
M&L for Bricks for protection cover to under ground cable (with old size sub class ‘B’ bricks) with width equal to length of brick laid dry and flat abutting each other with gaps between adjacent brick not exceeding 10mm complete all as specified and directed.
Supply, Laying, Jointing, testing & commissioning LT under ground cable XLPE insulated, screened PVC bedded, galvanised steel strips or wire armoured, heavy duty with multi stranded aluminium conductor, 95 Sqmm, 3½ core cable, 1100 volts grade (ISI marked) laid in trenches, ducts, pipes or fixed on pole etc complete all as specified and directed.
S&F rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) capacity 500 ltrs hoisted and fixed in position all as specified in SSR Part-I complete with necessary fittings as reqd on site complete all as specified and directed.
M&L for galvanised steel tubes 25 mm dia "medium grade " (ISI marked) with all fitting( ISI marked) and fixed complete to walls and ceilings or laid in floors/trenches and under road, complete all as specified and directed.
M&L for gun metal gate valve/forged valve 25 mm bore with iron wheel head, screwed both ends for jointing iron pipes, non rising, forged brass spindle class-1, IS-778 marked complete all as specified and directed.
Shifting of precision air conditioner capacity 30000 K cal Per hour (2x10 ton) complete with all accessories and as specified and directed by Engr-in-Charge. Note :. The quoted rate shall be inclusive of the followings:- (i) Positioning and installation of IDU-02 Nos (ii) Positioning and installation of ODU -02 Nos (iii) Installation and laying of hard drawn copper pipe 7/8" 16 guage with 9mm thick Nitrle rubber insulation "O" class, complete/ fittings between indoor units and remote condensors. Complete piping shall be provided as per standard with necessary elbows and all fittings etc.- 50 Rm (iv) Installation and laying of hard drawn copper pipe 11/8" 16 guage with 9mm thick Nitrle rubber insulation "O" class, complete/ fittings between indoor units and remote condensors. Complete piping shall be provided as per standard with necessary elbows and all fittings etc.- 50 Rm (v) Installation and laying of indoor to outdoor inter connecting power cable of 2.5 sqmm 3 core copper flexible with pvc conduits- 50 Rm (vi) Installations of MS CI Channels for extension of structure and stand with existing structural rail supports with proper necessary painting - 02 Nos (vii) Installation of water inlet CPVC 25 mm without insulation-30 Rm (viii) Installation and laying of 4 core 16 sqmm copper armoured cable in trey - 40 Rm (ix) Installation and laying of 1 core 10 sqmm flexible greencable for earthing - 60 Rm (x) Installation and laying sequencing cable for sequencing unit - 30 Rm (xi) Installation and laying WLDO multi strength cable 1.5 sqmm cable 2 core - 10 Rm (xii) Installation and laying of cable trey GI 300 mm ladder type with necessary supports and elclosed with GI sheets -100 RM (xiii) Civil work for refrigerant piping root- wall opening /gypsum opening and closing after completion of piping -01 Job (xiv) Civil work for floor/false ceiling in case of any damage at the time of material movement (xv) Supply of refrigerant (R407/R410) as per site requirement- 50 Kg (xvi) Supply of Refrigerant compressor oil as per site requirement - 04 Ltrs (xvii) Indoor MS Stand Height 350 mm with height adjustable with epoxy anti corrosive coating.
Schedule of Credit
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.39 MB
BOQ_844730.xls
BOQ • 0.29 MB
TENDERdocuments82546.pdf
Tender Documents • 0.67 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .