Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.0 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹20.6 L+₹24,456.05 (1.20%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST BIDDER | |
| 3 | L3₹21.6 L+₹1.3 L (6.33%)Rejected-Finance A 46 ARYA NAGAR ALWAR RAJ 301001 | ALWAR | RAJASTHAN | 301001 | L3 | Rejected-Finance NOT LOWEST BIDDER | |
| 4 | L4₹22.0 L+₹1.6 L (7.91%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST BIDDER | |
| 5 | L5₹22.2 L+₹1.9 L (9.11%)Rejected-Finance | L5 | Rejected-Finance NOT LOWEST BIDDER |
Tender Value
₹23.6 L
EMD Value
₹47,100
Closing Date
13 Aug 2020, 6:00 pmClosed
GE ALWAR
GE ALWAR
SPL REPAIR OF BLDG NO T-15, T-21 AND T-56/B (OR TOILET BLOCK) AT ITARANA CANTT ALWAR
2020_MES_361153_1
8935/E8
Open Tender
Civil Works
Item Rate
180 days
ALWAR
AS PER NIT
3 documents required · 3 mandatory
₹500
GE ALWAR
₹47,100
Yes
13 Oct 2020
15 Jul 2020
15 Aug 2020
15 Jul 2020
13 Aug 2020
30 Jul 2020
15 Jul 2020 - 29 Jul 2020
Amount
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc., laid, bedded and pointed in any mortar complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Taking down cement plaster or cement lime plaster on PCC/stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floor and paving not exc 15 cm thickness (below or above ground level) & removing unserviceable materials in low laying area complete all as directed.
Demolition of brick/stone masonry built in cement/lime mortar of any mix and stacking serviceable stones aside for reuse & removing unserviceable materials in low laying area complete all as directed.
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) as in roof, floors (other than ground floor), beam, staircases, landing, chajjas and similar suspended works complete all as specified and directed.
Taking down chowkat or frame with shutters area exc 1.5 Sqm but not exc 4 Sqm each (without taking off the wooden shutters from the frame) including cutting holes for hold fasts complete all as specified.
Taking down chowkat or frame with shutters area not exc. 1.5 Sqm each (without taking off the wooden shutters from the frame) including cutting holes for hold fasts complete all as specified
Taking down shutters of any description exc 1 Sqm and not exc. 2 Sqm each.
Dismantling AC sheet (Corrugated, Semi corrugated etc) as in roofs etc complete all as specified
BLANK
Demolition and breaking up 150mm bore drain pipes, salt glazed stone ware or reinforced concrete, set in cement mortar including PCC haunching and bedding, complete.
M & L brick work with FLY ASH BRICKS {As per IS-13757 (1993) burnt clay fly ash building bricks}, (OLD SIZE BRICKS) straight or curved on plan to any radius in half brick thick wall, built in cement mortar 1:4 complete all as specified and directed.
M & L brick work with FLY ASH BRICKS {As per IS-13757 (1993) burnt clay fly ash building bricks}, (OLD SIZE BRICKS) straight or curved on plan exc 6 mtr mean radius built in cement mortar 1:6 complete all as specified and directed.
All as per serial item No 14 here-in-above but except bricks.
M&L for cement concrete 1:2:4 type B0, using 12.5mm graded crushed stone aggregate as in copings and the like including weathering, slightly rounded, chamfered angle and throating as directed including use and waste of form work (straight or curved) all exposed surface of concrete finished fair complete all as specified and directed.
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exc 200mm thick (horizontal or sloping) for rough finished flat surfaces of concrete complete all as specified and directed.
M&L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exc 20cm wide and sides of RCC / PCC bands in walls, horizontal or sloping and similar work exc 10cm but not exc 20cm wide for rough finished surfaces of concrete complete all as specified and directed.
M&L for reinforced cement concrete (nominal mix) 1:2:4 type B1 using 20mm graded stone aggregate in slabs supported on walls, beams and columns in floors, roofs, shelves and the like. Note :- Reinforcement & formwork shall be measured and paid for separately.
M&L for mild steel TMT bars 10mm dia & over cut to length bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and bending with and including MS wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
All as per item No.20 above but 6mm dia to 8 mm dia.
M&L for PCC 1:2:4 type B0 using 12.5mm graded crushed stone aggregate as in flooring 25mm thick finished fair & even complete all as specified and directed.
M&L for coloured non skid ceramic tiles (1st quality), 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and as directed.
M&L for coloured glazed ceramic tiles (1st quality), 450mm x 350mm x 7mm thick on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10mm thick rendering (as screed bed) in cement & sand mortar 1:4 complete all as specified and as directed.
M&L machine cut Kota stone slab flooring 20 to 25mm thick laid over & including screed bed or bedding layer of 20mm thick in CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing to achieve mirror finish complete all as specified. Note : Kota stone shall be brought at site in minimum size of 560 x 560mm.
M&L for machine cut Kota stone slab 20 to 25mm thick, as in in riser of steps, skirting, dado and pillars etc. set and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over & including rendring of 10mm thick in CM 1:4 complete all as specified.
M&L for rubber moulded concrete coloured tiles (1st quality), 300mm x 300mm x 22-25mm thick as in floor, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 20mm thick screed bed in cement & sand mortar 1:6 complete all as specified and as directed.
M&L for rendering 10mm thick in cement mortar 1:6 on fair faces of brick masonry or concrete surfaces of walls including finishing the surface fair and even complete all as specified.
M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces of walls, mixed with water proofing admixture (ISI marked) as per manufacturer’s instructions, finished even and smooth without using extra cement complete all as specified. Note : - Supply only water proofing admixture shall be measured and paid for separately.
M&L for rendering 5mm thick in cement mortar 1:3 on concrete surfaces of ceiling including finishing the surface even and smooth without using extra cement complete all as specified.
M&L for 50 mm thick PCC 1:3:6 type C1 using 20 mm graded crushed stone aggregate as in plinth protection surface finished fair and even complete all as specified. Note :- Plinth protection shall be of width as directed and shall be laid to slope of 1:30 in alternative bays not exceeding 3 meter in length. Joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with bitumen mastic (1:3).
Taking down carefully existing bitumen tarfelt, including plaster of any description over the roof surfaces of buildings, terraces including flashings and junctions of parapets / curb walls etc in all respect and preparing it for further treatment and taking out and removing the rubbish from site complete all as specified and as directed.
M&L for 15mm thick plaster over top of roof slab/chajjas in CM 1:4 mixed with water proofing admixture (ISI marked) as per manufacturer’s instructions, finished even and smooth without using extra cement complete all as specified. Note : - Supply only water proofing admixture shall be measured and paid for separately.
Supply only integral liquid water proofing compound (ISI marked). Make : Pidilite (Dr. Fixit Pidiproof LW) or equivalent of Fosroc / Sika / STP
S&F APP polymeric water proofing membrane, minimum 3mm thick and weighing not less than 3.0 Kg/Sqm of make super thermo lay manufactured by STP Ltd of 'Hyper Plas' (Polyester) manufactured by M/s IWL Ltd or 'Shaliplas' (polyester) manufactured by M/s Capital Steels and chemicals Pvt Ltd or Hydro Stop manufactured by TIKITAR DANOSA (INDIA) Pvt Ltd as approved by GE, black finish reinforced with nonwoven polyester matt, with a thermo fusible finish laid over compatible bitumen primer (Bitumen primer shall be TANK MASTIC of M/s STP Ltd or 'WMW FLATE' of M/s Texas India Ltd) at the rate of 0.40 Kg/Sqm torching overlaps with a propane or a butane gas torch, with a overlap of 75mm at the sides and 100mm at the ends and sealing including applying a coat of cold emulsion bituminous primer all as per manufactures' instructions complete all as directed. Cont...
Cont... Note:- (i) Coved fillets in PCC (1:2:4) type B-0 using 12.5mm graded stone aggregate, of radius 75 mm shall be provided at the junction of roof and parapet wall/mumty/chimney/other vertical surfaces and thereafter surface painted with hot paving bitumen of Grade 30/40 confirming to IS-73, [email protected] Kg/Sqm over a coat of bituminous primer confirming to IS-3384 applied @ 0.40Kg/Sqm. (ii) Polymeric membrane shall be taken to a height of 45cm (minimum) and then inserted inside the grove of parapet wall of brick masonry and shall be finished by a membrane flushing. (iii) The waterproofing treatment shall be got carried out by the manufacturer or their authorized applicators. Cont...
Cont... (iv) In case of stone masonry parapet wall etc a groove of size 25mmx25mm(minimum) shall be made in coved fillet at the junction of roof and parapet wall/mumty Chimny/other vertical surfaces and polymeric membrane inserted in groove and sealed with paving bitumen. (v) Exposed surfaces of APP membrane shall be applied with one coat of bituminous aluminum paint @ 150 ml/Sqm. (vi) Above aspects are deemed to be included in quoted rate.
Taking up or down 15mm bore steel tubing and connection incl cleaning for refixing or removal to store
Taking up or down 20mm bore steel tubing and connection incl cleaning for refixing or removal to store
Taking up or down 25mm bore steel tubing and connection incl cleaning for refixing or removal to store
Refixing old steel tubing and connection in new or old position (wall, ceiling, floor etc) of 15mm bore of pipe.
Refixing old steel tubing and connection in new or old position (wall, ceiling, floor etc) of 20mm bore of pipe.
Refixing old steel tubing and connection in new or old position (wall, ceiling, floor etc) of 25mm bore of pipe.
S&F galvanised steel water tubing medium grade of 15mm bore with & including all fittings and fixed complete to walls and ceilings or laid in floors with required size of flat iron (25mmx3mm) clamps complete all as specified and directed.
S&F galvanised steel water tubing medium grade of 20mm bore with & including all fittings and fixed complete to walls and ceilings or laid in floors with required size of flat iron (25mmx3mm) clamps complete all as specified and directed.
S&F galvanised steel water tubing medium grade of 25mm bore with & including all fittings and fixed complete to walls and ceilings or laid in floors with required size of flat iron (25mmx3mm) clamps complete all as specified and directed.
M&L for cutting chases, pinning in, making good to facings as original where required and pointing in cement mortar 1:3 for concealed water tubing etc. and making good, cutting not exc 10 cm girth in brick walls.
S&F as in repair vitreous china squatting pan (Orissa pattern) water closet (white) of size 580x440mm with integral foot rests, 'P' or 'S' trap, including connection to trap and flushing pipe, antisyphonage pipe etc including making good to distrubed surfaces of floor to match with existing sorroundings complete all as specified.
S&F as in repair PVC valveless, syphonic action type, flushing cistern, low level, white (ISI marked) of 10 litre capacity with inlet, ball valve, float and handle including brackets, flush pipe of polyethylene of low or high density or 32 mm dia PVC pipe, for low level cistern connections to pipes and fixing of chain and pull, or lever, if any complete all as specified..
S&F as in repair vitreous china wash hand basin, white, flat back of size 550mm x 400mm with & including cutting for and pinning in ends of brackets or erecting stand, 32 mm dia PVC waste pipe and 32mm bore chromium plated brass waste fitting with long screwed shanks and fly nuts, flange end bedded in red lead cement & other end fixed complete all as specified.
M&L for High density polyethylene (HDPE) pipes (ISI marked) of pressure rating 6 kg/sqcm of 32mm bore with & including all fittings (ISI marked) and fixed complete to walls, ceilings or in floors etc including taking out old unserviceable pipe all as specified and directed.
M&L for High density polyethylene (HDPE) pipes (ISI marked) of pressure rating 6 kg/sqcm of 40mm bore with & including all fittings (ISI marked) and fixed complete to walls, ceilings or in floors etc including taking out old unserviceable pipe all as specified and directed.
S&F in repair 15mm bore stop / angle valve, cast copper alloy, chromium plated, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions.
S&F as in repair 15 mm bore bib tap, cast copper alloy, chromium plated, fancy type with capstan head, screwed down, screwed for iron pipe or for brass ferrule & fixed complete all as specified and directed.
S&F fancy type pillar tap, cast copper alloy with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks & fly nuts, screwed for iron pipes of 15mm bore.
S&F PVC connection 600 mm long suitable for 15 mm bore GI pipe including PTMT nuts on both sides complete all as specified.
S&F brass chromium plated shower rose 125mm size without swivel joint including fixing to steel pipe of 15mm bore or union complete all as specified.
S&F glass corner shelf of size 200mm x 200 mm, 6mm thick outer edges rounded fixed to wall with chromium plated brass brakets, screws and wooden / plastic plug complete all as specified and directed.
S&F stainless steel peg set of six fixed to wall with two rawl plugs and chromium plated (CP) brass screws complete all as directed.
S&F tubular towel rail, brass chromium plated, 20mm dia, ‘D’ type, 60cm long between flanges fixed to wall complete all as specified and directed.
S&F Grating doom 100 mm dia of PTMT (Minimum weight 25 gms) all as directed.
S&F PVC (SWR) floor trap plain with PTMT grating including jointing with solvent cement, diameter of outlet 75mm, complete.
S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified. Note :- Excavation & earthwork shall be measured & paid for separately.
S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified.
S&F 110 mm bore PVC (SWR) bends any radius complete all as specified.
S&F 110 mm bore PVC (SWR) single junction (single 'T' ) equal or unequal with access door complete all as specified.
S&F 110mm bore PVC (SWR) branch piece, single (single ‘Y’) equal or unequal with access door.
S&F PVC (SWR) reducer 110mm to 75mm bore complete all as specified.
S&F 75mm bore PVC (SWR) vent cowl complete all as specified.
S&F 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified. Note :- Excavation & earthwork shall be measured & paid for separately.
S&F 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified.
S&F 75 mm bore PVC (SWR) bends any radius complete all as specified.
S&F 75mm bore PVC (SWR) single junction (single ‘T’) equal or unequal complete all as specified.
S&F 110mm PVC (SWR) WC connector bent type complete all as specified.
Demolition and breaking up 100mm/75mm bore drain pipes, salt glazed stone ware or reinforced concrete, set in cement mortar including PCC haunching and bedding, complete.
Dismantling water tank of capacity exc 500 ltr but not exc 1000 ltr and removing from site complete all as directed.
S&F 1000 Litre capacity Rotational moulded polyethylene water storage tanks double layered (cylindrical vertical with closed top) ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-I
S&F as in repairs Ball valves, high pressure of PTMT with epoxy coated aluminum rod & high density plastic ball, screwed for iron pipe 25mm dia (minimum weight 455 gms) complete all as specified and as directed.
S&F as in repair 25mm bore Gun metal gate valve with iron wheel head, screwed both ends for iron pipe copmplete all as specified and directed.
S&F factory made solid PVC door frame of size 50mm x 47mm made out of 10mm plain colour single piece extruded PVC profile reinforced with MS square tube in opening as per specifications.
S&F factory Made Solid PVC Moulded Door Shutter, With Particle Board Core, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing in SSR.
S&F anodized aluminium ventilator, half fixed and half louvers type, jointed together with cadmium plated steel screws, aluminium section weighing 0.55 kg/m powder coated of any colour as approved (Thickness or powder coating not less than 50 micron) including necessary joining cleats, glazing clips, rubber packing, anodized aluminium snap beading, screws etc. complete all as specified and directed. Notes :- (i) Weight of aluminium sections shall only be measured. (ii) Glass sheet will be measured seperately.
S&F factory made 35 mm thick plain framed, paneled shutter (Two panels) with lock rail and panel of 9mm thick BWP commercial ply or 12 mm thick veneered particle board with commercial veneering on both faces, size of rail and styles as per IS : 1003 (Part-I), kiln seasoned and chemically pressure treated using second class Hard Wood rail and styles, fixed to chowkat, complete all as specified and directed.
S&F factory made 35mm thick glazed and skeleton shutters made of second class hard wood, open rebated and prepared to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc., sizes of members of shutters as specified in clause 8.24 of Section 8 in SSR Part-I, kiln seasoned and chemically pressure treated, fixed to chowkat, complete all as specified and directed.
S&F factory made Steel windows Box type of any size double shutter one openeble with glazing bars and other openeble shutter without glazing bars, fabricated with members of standard size as shown on CEJZ TD drawing No. TD/2013/01 sheet 1/3 to 3/3 dated 30.03.13 and openeble for cooler/AC complete all as specified and directed. Note :- Quoted rate shall deemed to include S&F of lugs and flat iron as required, wire cloth, sheet glass, grills, guard bars and ironmongery as per drg or as directed by Engr-in-charge and prepration of new iron surface & applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified.
S&F Galvanised steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified.
Supply only 4mm thick Sheet glass, frosted, on one side and glazing in square exc 0.5 sq. m in each pane complete all as specified.
Supply only Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified.
S&F stainless steel butt hinges of size 100mm, heavy weight complete all as specified.
S&F butt hinges of size 100mm medium weight, cold rolled mild steel ISI marked complete all as specified.
S&F 200 mm long aluminium anodised barrel tower bolts of extruded section complete all as specified
S&F 150 mm long aluminium anodised barrel tower bolts of extruded section complete all as specified
BLANK
S&F extruded aluminium alloy handle, 125mm size, fabricated type, anodized (ISI marked) complete all as specified.
S&F extruded aluminium alloy handle, 150mm size, fabricated type, anodized (ISI marked) complete all as specified.
S&F 250 mm long mild steel sliding door bolts clip type, stove enameled black, with bright bolt not less than 12mm dia and including a minimum of 06 bolts and nuts, four on bolt plate and two on staple plate and fixed, ISI marked complete all as specified.
S&F 300 mm long aluminium alloy, anodized, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified.
S&F Floor door stopper of aluminium alloy body and tongue, anodized, with hard drawn steel spring, fixed in floor, overall length of cover plate 140mm complete all as specified.
S&F mild steel framed work such as doors / gates / steel frames grills, gratings, etc of angle or other section with gusset plates, rails, braces, etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors and similar works of Gde E-165(Fe 290) including welding etc. complete all as specified and directed.
BLANK
S&F mild steel framed work using ERW or induction butt welded tubes conforming to I.S 1161-1979 Grade St-240 including necessary welding, bolting, special shaped washer, clamps, cleats etc. complete all as specified and directed.
S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 5cm and not exc 10cm and dia of neck 11 to 15 mm complete all as specified.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws or ‘L’ type or ‘J’ type or cranked hooks bolts complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws or ‘L’ type or ‘J’ type or cranked hooks bolts complete all as specified and directed.
M&L for mild steel work as Hand rails, half round or other stock section or core for wooden handrail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Gde E-165 (Fe 290) all as specified and directed.
M&L for false ceiling with Armgyp-FB ceiling tiles of size 595 x 595mm, 9mm thick (as approved by GE) fixed with and including galvanized iron powder coated inverted ‘Tee’ or ‘L’ section (concealed GI frame work) suspended from ceiling with provision of galvanized wire 4 mm dia and wall taping screw including butterfly clips, hold down clips for fixing the board to frame complete all as per manufacturer’s instructions including dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards / slabs / blankets any thickness, including cover fillets complete, all as directed and specified. (a) Size of grid – 610 x 610 mm. (b) Size of main Tee – 39 x 24.70 x 0.80 mm. (c) Size of cross Tee – 39 x 24.70 x 0.80 mm. (d) Size of wall angle – 22.20 x 22.20 x 0.65 mm.
S&F as in repair 4mm dia plain mild steel wire, galvanized class 3, in detached work such as for mosquito nets and fixing to straining bolts, hooks, eyes, etc. as directed (each line of wire to be measured).
S&F mild steel chromium plated tubular curtain rod 20mm dia (in lengths as directed) with & including pair of projecting type mild steel chromium plated brackets fixed at both ends with PVC rawl plug & steel screws on walls/beam complete all as specified and directed.
M & L preparation of new steel surfaces of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified.
M&L for preparation of new surfaces of wood or wood based materials of any description over 10 cm width or girth and applying two coats of synthetic enamel paint of approved tint over a coat of pink primer complete all as specified.
M&L for preparation of old painted surfaces of wood and wood based material of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint all as specified.
M&L for preparation of old painted steel and iron surfaces of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint all as specified.
M&L for preparation of new plastered surfaces of walls and applying 2mm thick birla white wall care putty to achive smooth complete all as specified and directed.
M&L for preparation of newly plastered surface of ceiling & applying three coats of white wash complete all as specified.
M&L for preparation of old decorated surfaces of ceilings & applying two coats of white wash complete all as specified.
M&L for preparation of new plastered surfaces of wall and applying two coats of oil emulsion distemper (OBD) of approved shade / tint over a coat of primer complete all as specified and directed.
M&L for preparation of old decorated surface of walls and applying two coats of oil emulsion distemper (OBD) of approved shade / tint complete all as specified.
M&L for preparation of newly plastered surface of walls and applying two coats of cement base paint of approved shade / tint over a coat of priming paint complete all as specified.
M&L for preparation of old decorated plastered surfaces of walls and applying two coats of cement base paint of approved shade / tint complete all as specified and directed.
Excavating in trenches not exc 1.5m wide and not exc 1.5m in depth; for foundation, etc or for shafts, wells, cesspits, manholes etc not exc 10Sqm on plan and not exc 1.5m in depth and getting out in soft / loose soil complete all as specified and directed.
M&L for PCC 1:4:8 type D2 using 40 mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed.
M&L for brick work with old size sub-class ‘B’ bricks, straight or curved on plan exc 6.00 metre mean radius, built in cement mortar 1:4 complete all as specified.
M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces of walls including finishing the surface even and smooth without using extra cement complete all as specified.
M&L for for PCC 1:2:4, type B-1 using 20mm graded crushed stone aggregate as in water through, surface channels and drains including necessary formwork, complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement including forms, moulds, mitred/stopped ends etc.
M&L for precast RCC 1:2:4 type B1 using 20mm graded stone aggregate as in cover slabs of drains, manholes etc. including placing in position and set in CM (1:4) complete all as specified and directed. Note :- Reinforcement shall be measured and paid for separately.
M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate in bedding to SGSW drain pipes, including packing under and haunching against the sides of pipes after they are laid and tested complete for 150 mm bore pipe all as specified and as directed.
S&F salt glazed stone ware drain pipes of 150mm bore, grade `A', ISI marked, laid to slope in trenches, jointed in CM (1:1) and tested complete all as specified.
Cutting into existing manholes/Septic tank for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 smooth finished and reforming benching as required for 150mm bore pipe.
Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25cm in soft / loose soil complete all as specified& directed by Engr-in-Charge.
Removing soil n.exc.50 & depositing where directed at a level n exc.1.5 m above the starting point, complete all as specified and directed.
Taking down carefully, copper / aluminium unserviceable /perished point wiring any type for light/ fan/ socket or power complete including fittings such as switches, ceiling roses, pendant holders, lamp holders, bracket holders, regulators sockets, light fittings etc, and making good to disturbed surfaces of wall/floor/ceiling etc, complete, all as specified and directed.
M&L for point wiring for one light point controlled by one, one way switch with 1.50 Sqmm two single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including PVC casing & caping with accessories fixed on surface of walls/ceiling by means of PVC sleeves/dash fasteners with cadmium plated screws, all as per IS and including wooden boxes fixed on wall with and including 3mm thick phenolic laminated sheet top cover for mounting switches, sockets, fan regulators etc complete all as specified.
All as per serial item No. 2 here-in-before but for one fan point controlled by one switch and regulator.
All as per serial item No. 2 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on same board.
All as per serial item No. 2 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on independent board.
All as per description of serial item No. 2.00 here-in-before but for one 3 pin socket outlet 15/16 Amps with 2.50 Sqmm two single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade including 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour
S&F switch piano flush type, single pole, one way, 5/6 Amp, 230 Volts complete all as specified and directed.
S&F switch piano flush type, single pole, one way, 15/16 Amp, 230 Volts complete all as specified and directed.
S&F socket outlet for 3 pin, 5/6 Amp, flush type 240 Volt complete all as specified and directed.
S&F socket outlet for 2 in 1, 3 pin 5/6 & 15/16 Amp, flush type 240 Volt complete all as specified and directed.
S&F lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
S&F ceiling rose surface Bakelite 65x50mm two or three terminals complete all as specified and directed.
S&F fan regulators electronic step up type socket size and connecting up, ISI marked flush type, 120 watt, 230 volts complete all as specified and directed.
S&F decorative ultra slim round profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient suitable for 16 Watt to 20 Watt with LED tube 6000K of model E-LITE LED Pride Plus and connecting up with and including three core, PVC insulated, sheathed copper conductore cable of required size and length from ceiling rose to fitting complete all as specified & directed. Make :- Havells Cat Part No LHEXBLP7PN1W018 or equivalent of Syska / Crompton Greaves as approved by GE
S&F Adore LED lamp of 9 / 10 Watt including taking down old u/s CFL lamp complete all as specified. Make :- Havells Cat Part No LHLDERHEML8X010 or equivalent of Philips / Crompton Greaves / Wipro / Bajaj / GE
Supply and fixing LED type street DRACO Series light luminaire 20 watt 230 V 50 Hz including all necessary fitting accessories and LED complete, all as specified & directed. Make :- C&S Cat Part No LTESS20WLED or equivalent of Havells / Syska / CG as approved by GE
S&F sheet metal enclosures, double door type, suitable for fixing MCB,s, SPN with 200 Amps rated bus bar, 8 way, 240 volts complete all as specified and directed.
S&F MCB 32 Amps, single pole & neutral, 230 Volts complete all as specified and directed.
S&F MCB 6 to 32 Amps, single pole, 230 Volts complete all as specified and directed.
S&F 2nd class hard wood rectangular block open recessed of size 30x25x5 cm depth with 3mm thick hylum/Bakelite sheet on top grouted with 4 Nos bolts for DB complete all as specified and directed.
M&L for sub main wiring with two runs of 6 sqmm (nominal area) size main cable & one run of 4 sqmm size earth continuity conductor, single core, PVC insulated, unsheathed, FRLS with multi-stranded copper conductor, 1100 Volts grade, ISI marked (IS: 694) cables, drawn through & including suitable size of heavy duty PVC conduit ISI marked not less than 25mm dia & conduit fittings/accessories, fixed on surfaces of wall/ceiling including taking down old unserviceable wiring complete all as specified and directed. Note:- 02 runs of 6 sqmm size, 01 run of 4 sqmm size cable & conduit with accessories shall be measured as one run length for payment purpose.
Supply, laying, jointing and testing XLPE insulated, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade cross sectional area 16 sqmm 2 core laid in trenches, along poles through pipes etc complete all as specified & as directed. (i) Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately including taking down old unserviceable XLPE cable (ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions.
M & L for brick work with FLY ASH BRICKS {As per IS-13757 (1993) burnt clay fly ash building bricks}, (OLD SIZE BRICKS) with width equal to the length of the brick laid dry & flat abutted with each other with gap between adjacent bricks not exc 10 mm over UG cable for protection complete all as specified & directed.
M&L dry sand (Tibba sand) and punning for cushioning to under ground cable all as directed. Note :- For the purpose of payment only punned thickness shall be measured.
M&L for Galvanized iron tubing, 40mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls with required size of flat iron (25mmx3mm) clamps, bolts, nuts and washers for protection of LT electric cable complete.
Material and labour for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/equipment and testing on contn...
cont.... including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore 3.00 metre long GI pipe light grade for earth wire protection fixed with poles with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:3:6) type C1, 40mm thick precast RCC cover 1:2:4 type B1 shall be provided on CI frame etc complete including taking down old unserviceable earthing all as specified & as directed.
L P Singh and Co.
M/s ASK Enterprises
S.S Enterprises
shiva construction
M/S GAURI CONSTRUCTION
M/s V T Contractors
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .