| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.2 LAccepted-AOC 32 H I G AWAS VIKAS COLONY SECTOR 3 BODLA AGRA UP 282007 | AGRA | AGRA | UP | 282007 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹42.5 L+₹2.0 L (4.81%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹42.7 L+₹2.2 L (5.32%)Rejected-Finance 00 BEHIND CHARCH NAYAGOWAN LAKHERA BEHIND RAMA MANI DAIRY KATNI MADHYA PRADESH 483501 | KATNI | MADHYA PRADESH | 483501 | L3 | Rejected-Finance Being other than L1 | |
| 4 | L4₹44.7 L+₹4.1 L (10.1%)Rejected-Finance | L4 | Rejected-Finance Being other than L1 | |
| 5 | L5₹45.1 L+₹4.5 L (11.1%)Rejected-Finance | L5 | Rejected-Finance Being other than L1 |
Tender Value
₹41.5 L
EMD Value
₹83,000
Closing Date
5 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (East) Agra
Garrison Engineer (East) Agra, Military Engineer Services, Gwalior House, 62 Taj Road Agra Cantt-282001
ADDN/ALTN OF DARK ROOM, CLEAN ROOM (BLDG-45) AND PNVD SECTION IN 509 ABW UNDER GE (EAST) AGRA
2024_MES_665479_1
9691/E8
Open Tender
Civil Works
Item Rate
180 days
AGRA (UP)
Please refer tender documents
10 documents required · 10 mandatory
₹500
GE (East) Agra
₹83,000
Yes
18 Oct 2024
12 Jul 2024
12 Sept 2024
12 Jul 2024
5 Sept 2024
26 Jul 2024
Amount
S&F Standard wall Portion/paneling sandwiched are a composite of two skins of PPGI/PPGI over a GI frame work with a sealed and insulated interior, standard panel dimension are 1850x300 mm straight panels have an overall thickness 100 mm additional wall heights can be achieved using a stacking technique. The self supporting internal walls are constructed with both side finishing. PUF insulation materials is sandwiched between the two skin layers and sealed from the exterior by the GI frame complete all as specified and directed.
Demolition of wall and ceiling board or insulation board /slabs/blanket any thickness including cover fillets complete all as specified and directed.
M&L for false ceiling panels are designed to fit within each other and suspended by threaded tension wire with adjustable turnbuckles fastened to the overhead support at fixed intervals, standard ceiling panels are 50 mm thick and have a construction of two skins of PPGI/PPGI a GI frame work with a sealed insulated interior and ext al powder coated anodised R42 clip on type for wall to wall and, wall to ceiling and wall to floor double skin panels, and al powder coated / anodised 3 D internal corner piece complete all as specified and directed.
M&L for doors designee to fit flush into the wall panel system on both sides and are supplied in different dimensions doors are fabricated from galvanised iron sheets quality powder coated shutter has sheet thickness of 0.80 mm and the frame of 1.2 mm. standered 50 mm panel has frame width of 50 mm and shutter width of 46 mm. doors size is 1500x2100 (or more fit to existing opening) mm doors are with all describe accessories. Note :- 1- automatic( SS hinge, SS D type handles, SS Push plate on push side, standard arm door closure (TS-68) , and view panel alongwith shelf adhesive tape and silicon sealant) 1- door bottom seal at the bottom 2- SS kick plats (double door) 3- flush view / glazing panels on wall designed to fit into wall panel with 6 mm glass are included.
M&L for vinyal flooring, high density floor covering for CL-100 K as per below specification. 1- class- Electrostatic conductive. 2- 02 mm thick, 3- size of tile 61x61 Cm 3- wear resistant -0.17 mm, 4- Fire resistant - B1/Q1 5- Heat Resistant - 0.011 Sqm K/W, 6 - Fire complete all as specified and directed.
S&F double glazed fixed type windows all as specified each set shall consists of 02 each double glazed fixed type window panel complete all as specified and directed.
Taking down aluminium chowkats or frame with shutter (without taking off shutters from the frame) not exc 1.5 Sqm each complete all as specified and directed.
All as per item No 7.00 before but exc 1.5 Sqm and not exc 4.00 Sqm each complete all as specified and directed.
M&L for insulated PVC Solid PVC Wall Lining consisting of 5mm thick but black colour PVC sheet used instead of plain colour sheet fixing with solvent cement and fixing at site on PVC frame complete all as specified and directed.
M&L for 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing complete all as specified and directed.
Preparation of old wall/ceiling surfaces of any description over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint black at any height complete all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete and all as specified and removing from site complete all as specified and directed.
M&L point wiring with 1.5 sqmm multi stranded copper conductor 1100 volts. grade FRLS PVC insulated unsheathed cable with proper colour coding drawn in including stove enammelled steel conduit not less than 20 mm dia with all accessories and FRLSH PVC insulated 1.5 Sqmm multi standard sheathed copper wire for continues earth, sunk in cast iron/Pressed steel terminal boxes 60 mm deep & 1.6 mm thick duly painted with aluminum inside and anticorrosive paint outside including 3 mm thick plastic laminated sheet for mounting switches, sockets, fan regulators etc connecting earth and making good to the disturbed surface of wall/floor and matching with existing specifications. Connections of cable with MCB's or bus bar shall be done through proper size copper/brass thimbles. Note :Conduit shall be fixed on surface of roof with necessary saddles where concealing of conduit is not feasible at no extra cost for the following :- (a) One light /fan point controlled by one switch
(b) One 5 pin socket outlet 5 Amps on independent board complete all as specified and directed.
(c) One 5 pin socket outlet 5 Amps on same board complete all as specified and directed.
(d) One bell/buzzer point controlled by one push button on the same board with other switches or independent complete all as specified and directed.
All as per item No 13.00 above but with 2.5 sqmm multi stranded copper conductor 1100 volts grade FRLS PVC insulated sheathed cable with FRLS PVC 2.5 Sqmm multi standard insulated unsheathed copper wire for continues earth on independent board complete all as specified and directed.
All as per item No 13.00 here in before but with cable size 4 Sqmm for one AC socket out let on independent board and multi strand insulated copper earth continuity conductor of size 4 Sqmm all as specified and directed.
Supply and fix switch piano flush button single pole one way 5 amps 240 volts with polycarbonate body complete all as specified and directed.
Supply and fixing Bell push, flush type, 5 amp, complete all as specified and directed.
Supply and fix Switch piano flush button single pole one way 15 amps 230 Volts with polycarbonate body complete all as specified and directed.
Supply and fix socket 5 amps 5 pin flush type, 240 volts with polycarbonate body complete all as specified and directed.
Supply and fix socket out let, 6 pin 5 and 15 amps multipurpose 2 in 1 flush type, 230 volts with polycarbonate body complete all as specified and directed.
Supply and fix stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc as reqd complete all as specified and directed.
Supply and fix ceiling rose, PVC/polycarbonate, insulated body surface Bakelite 65mm dia three terminals complete all as specified and directed.
Supply and fix Lamp holder/angle holder insulated body with black/white plate for batten fittings including 9 watt LED bulb complete all as specified and directed.
Supply and fix call bell, Ding dong type, 230 volts AC single pole complete all as specified and directed.
Supply and fixing in repair LED luminaire 600 mm x 600 mm, 36 watt, 220 V AC, 6500 K recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver and connecting the same to electric source with & using PVC sheathed and insulated three core copper conductor cable of size 0.75 Sqmm and fixing arrangements for fixing the light fitting complete all as specified and directed.
Supply and fixing in repair round shape 12 watt (moon light) 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Supply and fixing in replacement LED light fitting with high output diffuser 4 feet, 20 watt 220 V AC, LUMEN < 2000 with lumen efficacy 100 lumen/watt, basic all purpose surface and wall mounted LED batten with polycarbonate housing & integrated electronic driver including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F in repair Decorative wall light fixture made up of Polycarbonate, suitable for 9/10W LED bulb alongwith 9W LED Bulb, complete all as specified and directed.
Supply and fix Wall mounting fan 400 mm sweep with pull ON OFF cord 3 speed option with swing oscillation control wide 90 degree sweep angle with wall mounting bracket complete good the disturbed surface MS bolts, grouted to wall and connecting up including provision in cable from connector to fan with flexible cable 24/0.2mm with copper conductor and necessary fitting arrangements complete all as specified and directed at site.
S&F in repair sheet metal enclosure with socket plug top and MCB single pole and neutral with two pin and earth plug top with one SP MCB 20 Amp 240 volt complete all as directed all as specified and as directed.
S&F in repair sheet metal enclosure with socket plug top and MCB three pole with three pin plug top with one TP MCB 63 Amp 415 volt complete all as specified and directed.
Supply & fix in repair/replacement of sheet metal enclosure Vertical TPN DB 4 Way As per IEC 61439-3, Suitable for Flush Mounting and Surface Mounting, With 250 A Copper Busbar for each phase with 2 Neutral bar, 2 Earthbar and Cable ties for Cable management, fully insu5lated busbar & shrouded Neutral bars, Improved Pan assembly for ease of installation, Prefitted masking sheet, Reversible Door for IP 54 DB's, With provision for 250 Amp MCCB as incomer and SP/TP MCB's as outgoing complete all as specified and directed.
Supply & fix in repair sheet metal enclosure MCB distribution board. Single pole & neutral 240 volts 12 way with IP-43 protection double door complete with appropriate size bus bar and neutral link complete all as specified and directed.
Supply & fix in repair sheet metal enclosure MCB distribution board. Single pole & neutral 240 volts 8 way with IP-43 protection double door complete with appropriate size bus bar and neutral link complete all as specified and directed.
Supply and fixing in repair MCCB 4 pole, 250 Amps, 50 Hz, Icu=35 KA at 415 volts with thermal magnetic alongwith adjustable magnetic protection for current setting Icu=Ics = 100% with adjustable over load setting (minimum 70% to 100%) value from 10 to 15 times of related capacity as per IEC-60947-1 and 60947-2 standard complete all as specified and directed.
Supply and fixing in repair MCB SP 5 to 32 Amp rating 240V, 10KA 'C' curve and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
Supply and fixing in repair MCB SPN 40 to 63 Amp rating 240V, 10KA 'C' curve and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
M&L for Submain Wiring with two single core FRLSH PVC insulated unsheathed multistranded flexible copper conductor cable of size 2x2.5 sqmm and one single core PVC insulated multistranded unsheathed flexible copper conductor 1x2.5 sqmm size (green colour) cable as earthing lead connecting to main earthing dolly drawn in Steel Conduit not less than 20 mm dia including dismantling of old unsv submain wiring complete all as specified and directed by Engineer-in-charge including taking down of existing un serviceable sub main wiring complete all as specified and directed.
M&L for Submain Wiring with two single core FRLSH PVC insulated unsheathed multistranded flexible copper conductor cable of size 2x4 sqmm and one single core PVC insulated multistranded unsheathed flexible copper conductor 1x4 sqmm size (green colour) cable as earthing lead connecting to main earthing dolly drawn in Steel Conduit not less than 25 mm dia including dismantling of old unsv submain wiring complete all as specified and directed by Engineer-in-charge including taking down of existing un serviceable sub main wiring complete all as specified and directed.
M&L for Submain Wiring with four single core FRLSH PVC insulated unsheathed multistranded flexible copper conductor cable of size 6 sqmm and two single core PVC insulated multistranded unsheathed flexible copper conductor 6 sqmm size (green colour) cable as earthing lead connecting to main earthing dolly drawn in Steel Conduit not less than 32 mm dia including dismantling of old unsv submain wiring complete all as specified and directed by Engineer-in-charge including taking down of existing un serviceable sub main wiring complete all as specified and directed.
M&L for Submain Wiring with four single core FRLSH PVC insulated unsheathed multistranded flexible copper conductor cable of size 10 sqmm and two single core PVC insulated multistranded unsheathed flexible copper conductor 10 sqmm size (green colour) cable as earthing lead connecting to main earthing dolly drawn in Steel Conduit not less than 32 mm dia including dismantling of old unsv submain wiring complete all as specified and directed by Engineer-in-charge including taking down of existing un serviceable sub main wiring complete all as specified and directed.
M&L for Submain Wiring with four single core FRLSH PVC insulated unsheathed multistranded flexible copper conductor cable of size 2x16 sqmm and two single core PVC insulated multistranded unsheathed flexible copper conductor 16 sqmm size (green colour) cable as earthing lead connecting to main earthing dolly drawn in Steel Conduit not less than 40 mm dia including dismantling of old unsv submain wiring complete all as specified and directed by Engineer-in-charge including taking down of existing un serviceable sub main wiring complete all as specified and directed.
M&L for earthing complete with galvanized earth plate electrode 600 x 600 x6mm thick burried directly in ground vertically to a depth not less than 2.25 M below normal ground level ) with top edge of the plate not less than 1.50 M below normal ground level , connected to and including galvanised iron strip 32x6mm dia as earth lead soldered and riveted to earth plate by means of nuts, bolts, check nuts & washers, of galvanized iron or steel with connected to test point and testing on completion including 15mm GI light grade pipe for earth lead protection from earth point to earth plate, including provn adequate quantity of charcoal dust mixed with 35 % common salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth plate with 20mm bore medium grade GI Pipe for watering, GI check nut, funnel and wire mesh with and including all necessary excavation & earth work in soft/loose soil, returning filling in, removal of surplus soil to a distance 50 metre, PCC 1:3:6 type C-1 as in earth pit, 40 mm thick RCC cover using cement concrete 1:2:4 type B-1 reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work complete all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 complete all as specified and directed. NOTES:- (i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone at without any extra cost by contractor.
Supply and fixing as in replacement of Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe not less than 40mm or fixed to poles or any other indicated situation for loop earthing etc. as required 25x3mm aluminium strip complete all as specified and directed.
Supply and lay XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 95 Sqmm 3.5 Core, complete all as specified and directed.
Supply and fixing cable tray of size 100mm including all fittings complete all as specified and directed.
Supply and install Air Shower for clean room application for single person entry, made out of 1.2mm, SS 304 body construction matte PVC coated sheet complete with pre filters blowers motor assembly nozzels and electromagnetic interlocking system of size 800x900x2000mm (Internal Dimension) and 1400x900x2100mm (External Dimension) completed all as specified and directed.
Supply and fix Pre filter (Rough) Box type, 5 micron of 600mm x 600mm down to 5 micron complete all as specified and directed.
Supply install testing and commissioning Hepa Filters with aluminium anodized frame (down to 0.5 Micron) efficiency 99.97% of size 600mm x 600mm x 150mm with 3mm thick PP foam gaskets will be fixed on both sides of the collor of filter casting 1.6mm thickness aluminium box type casing medica imported of capacity 500 Cfm complete all as specified and directed.
SahaDevSingh Constructions (BID ID -3084774)
3Krishna Enterprises (BID ID -3080837)
N.K. ENTERPRISES (BID ID -3083838)
M/S RADHEY GOVIND ENTERPRISES (BID ID -3084788)
milan enterprises (BID ID -3085704)
VARDMAN ENTERPRISES (BID ID -3082135)
M/s Kok Singh Sisodia (BID ID -3076089)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .