| Sl No | Description | Qty | Unit | RISHABH ENGINEERS L1 | Gupta Brothers L3 | AJAY ENTERPRISES L4 | MANVIK ENTERPRISES L5 | ISHIKA ASSOCIATES L2 |
|---|---|---|---|---|---|---|---|---|
| 1.01 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group A DSR 1.10.3 | 50 | Each | 27,500 ₹27,500 | 27,500 ₹32,450 | 37,500 ₹44,250 | 42,500 ₹42,500 | 12,500 ₹14,750 Lowest |
| 1.02 | Wiring for circuit /submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor. single core cable in surface / recessed PVC conduit as required 2 X 4 sq. mm + 1 X 4 sq. mm earth wire DSR 1.14.3 | 50 | Meter | 10,500 ₹10,500 | 8,750 ₹10,325 | 7,500 ₹8,850 Lowest | 11,000 ₹11,000 | 17,500 ₹20,650 |
| 1.03 | Wiring for circuit/ submain wiring along with earth wire with the 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. DSR 1.14.1 | 100 | Meter | 11,500 ₹11,500 Lowest | 10,000 ₹11,800 | 12,500 ₹14,750 | 18,000 ₹18,000 | 20,000 ₹23,600 |
| 1.04 | Installation, test fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including and commissioning of pre-wired, fluorescent connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required DSR 1.41 | 50 | Each | 7,250 ₹7,250 Lowest | 12,500 ₹14,750 | 7,500 ₹8,850 | 11,000 ₹11,000 | 11,000 ₹12,980 |
| 1.05 | Supplying and fixing 12 way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).DSR(E&M) 2.3.4 | 1 | Each | 3,550 ₹3,550 | 3,000 ₹3,540 | 4,000 ₹4,720 | 13,500 ₹13,500 | 2,000 ₹2,360 Lowest |
| 1.06 | Supplying and fixing 6 way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).DSR(E&M) 2.3.1 | 2 | Each | 3,780 ₹3,780 Lowest | 6,000 ₹7,080 | 6,000 ₹7,080 | 10,000 ₹10,000 | 4,000 ₹4,720 |
| 1.07 | Supplying and fixing two module stepped type electronic fan regulator on the existing plain / modular plate switch box including connections but excluding plain / modular plate etc. as required. DJB SOR Item code:31.25 | 10 | Each | 3,800 ₹3,800 | 2,500 ₹2,950 | 3,500 ₹4,130 | 2,200 ₹2,200 Lowest | 2,500 ₹2,950 |
| 1.08 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. - Single pole - (DSR No. 2.10.1) | 12 | Each | 2,280 ₹2,280 | 2,100 ₹2,478 | 5,400 ₹6,372 | 1,800 ₹1,800 Lowest | 2,400 ₹2,832 |
| 1.09 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. - Double pole - (DSR No. 2.10.3) | 5 | Each | 2,450 ₹2,450 Lowest | 5,250 ₹6,195 | 2,250 ₹2,655 | 3,100 ₹3,100 | 3,250 ₹3,835 |
| 1.10 | Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required 4 X 16 sq. mm + 2 X 6 sq. mm earthwire S.O.R 31.7.11 | 20 | Meter | 16,200 ₹16,200 | 20,000 ₹23,600 | 8,000 ₹9,440 Lowest | 18,400 ₹18,400 | 20,000 ₹23,600 |
Tender Value
Refer Docs
EMD Value
₹6,000
Closing Date
17 Jul 2026, 3:15 pmClosed
EE ENM M-7
DELHI JAL BOARD MU BLOCK PITAMPURA, DELHI-34
Internal and external Electrification of AE and JE Civil office at B Block Shakurpur in AC 16
2026_DJB_295194_5
NIT No. 09(2026-27)M-7
Open Tender
Miscellaneous Works
Item Rate
30 days
EE ENM M-7
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Account No 50448339804
₹6,000
Yes
22 Jul 2026
10 Jul 2026
17 Jul 2026
10 Jul 2026
17 Jul 2026
10 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group A DSR 1.10.3 | 50 | Each | 80 | ₹4,000 |
| 1.02 | Wiring for circuit /submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor. single core cable in surface / recessed PVC conduit as required 2 X 4 sq. mm + 1 X 4 sq. mm earth wire DSR 1.14.3 | 50 | Meter | 80 | ₹4,000 |
| 1.03 | Wiring for circuit/ submain wiring along with earth wire with the 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. DSR 1.14.1 | 100 | Meter | 80 | ₹8,000 |
| 1.04 | Installation, test fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including and commissioning of pre-wired, fluorescent connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required DSR 1.41 | 50 | Each | 80 | ₹4,000 |
| 1.05 | Supplying and fixing 12 way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).DSR(E&M) 2.3.4 | 1 | Each | 80 | ₹80 |
| 1.06 | Supplying and fixing 6 way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).DSR(E&M) 2.3.1 | 2 | Each | 80 | ₹160 |
| 1.07 | Supplying and fixing two module stepped type electronic fan regulator on the existing plain / modular plate switch box including connections but excluding plain / modular plate etc. as required. DJB SOR Item code:31.25 | 10 | Each | 80 | ₹800 |
| 1.08 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. - Single pole - (DSR No. 2.10.1) | 12 | Each | 80 | ₹960 |
| 1.09 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. - Double pole - (DSR No. 2.10.3) | 5 | Each | 80 | ₹400 |
| 1.1 | Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required 4 X 16 sq. mm + 2 X 6 sq. mm earthwire S.O.R 31.7.11 | 20 | Meter | 80 | ₹1,600 |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.17 MB
BOQ_392751.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .