Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.4 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹36.6 L+₹4.2 L (12.9%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹38.6 L+₹6.2 L (19.2%)Admitted-Finance | L3 | Admitted-Finance | |
| 4 | Rejected-Technical | - | Rejected-Technical Not Qualified on account of not meeting the bidding capacity as stipulated in NIT. |
| Sl No | Description | Qty | Unit | SAS ENTERPRISES L3 | MSE CONTRACTOR L1 | SRIRAM ELECTRICALS L2 |
|---|---|---|---|---|---|---|
| 1.00Identification of fault and replacement of following faulty items in residential and non residential buildings as per the detailed specification and as directed by Engineer In charge. Note: Required items will be issued at free of cost by department. | ||||||
| 1.10 | Identification of fault and replacement of 5A to 16A switches, Regulators, Modular plates of different sizes,Socket and plug tops in Flush/Concealed type MS switch boxes (Refer Sec VI (MNC), Clause No.4). | 50 | Nos. | 55 ₹2,750 | 100 ₹5,000 | 50 ₹2,500 Lowest |
| 1.20 | Installation of Exhaust /Air circulating fans upto 5mtrs height in the residential and non residential buildings. (Refer Sec VI (MNC), Clause No.6). | 50 | Nos. | 520 ₹26,000 | 700 ₹35,000 | 500 ₹25,000 Lowest |
| 2.00Supply and replacement of following Wiring Accessories as per the detailed specification and as directed by Engineer In charge. (Refer Sec VI (MNC), Clause No.5). | ||||||
| 2.10 | 1.5 to 2.5 mfd, 440V PVC polypropylene industrial type Capacitor for ceiling / Exhaust & Wall mounting Fans | 800 | Nos. | 175 ₹1,40,000 | 90 ₹72,000 Lowest | 160 ₹1,28,000 |
| 2.20 | 1 No 10A Switch on modular plate and termination of wires to the switches | 250 | Nos. | 185 ₹46,250 | 170 ₹42,500 Lowest | 180 ₹45,000 |
| 2.30 | 1 No 10 A, 2 Way Switch on modular plate and termination of wires to the switches. | 50 | Nos. | 185 ₹9,250 | 200 ₹10,000 | 180 ₹9,000 Lowest |
| 2.40 | 1 No 6 A 3 Pin shuttered type Socket on modular plate and termination of wires to the switches | 20 | Nos. | 185 ₹3,700 | 150 ₹3,000 Lowest | 180 ₹3,600 |
| 2.50 | 2 Module Step type Fan regulator on modular plate and termination of wires to the switches | 250 | Nos. | 640 ₹1,60,000 | 900 ₹2,25,000 | 600 ₹1,50,000 Lowest |
| 2.60 | 1 Module Electronic Regulator 450 Watt for ceiling fans and termination of wires to the switches | 150 | Nos. | 570 ₹85,500 | 700 ₹1,05,000 | 550 ₹82,500 Lowest |
Tender Value
₹35.3 L
EMD Value
₹70,600
Closing Date
17 Jul 2025, 3:00 pmClosed
Chief Engineer, CEG,GSO
Room No. 306, GSO Annex building, Kalpakkam - 603102
Maintenance of Fans and Earth pits
2025_GSO_865113_1
GSO/CTC/ESD/200/2025
Open Tender
Electrical Works
Item Rate
365 days
DAE Township, Anupuram
As stipulated in NIT/tender
8 documents required · 8 mandatory
₹0
₹70,600
20 Aug 2025
20 Jun 2025
18 Jul 2025
20 Jun 2025
17 Jul 2025
11 Jul 2025
21 Jun 2025 - 8 Jul 2025
Amount
Identification of fault and replacement of following faulty items in residential and non residential buildings as per the detailed specification and as directed by Engineer In charge. Note: Required items will be issued at free of cost by department.
Identification of fault and replacement of 5A to 16A switches, Regulators, Modular plates of different sizes,Socket and plug tops in Flush/Concealed type MS switch boxes (Refer Sec VI (MNC), Clause No.4).
Installation of Exhaust /Air circulating fans upto 5mtrs height in the residential and non residential buildings. (Refer Sec VI (MNC), Clause No.6).
Supply and replacement of following Wiring Accessories as per the detailed specification and as directed by Engineer In charge. (Refer Sec VI (MNC), Clause No.5).
1.5 to 2.5 mfd, 440V PVC polypropylene industrial type Capacitor for ceiling / Exhaust & Wall mounting Fans
1 No 10A Switch on modular plate and termination of wires to the switches
1 No 10 A, 2 Way Switch on modular plate and termination of wires to the switches.
1 No 6 A 3 Pin shuttered type Socket on modular plate and termination of wires to the switches
2 Module Step type Fan regulator on modular plate and termination of wires to the switches
1 Module Electronic Regulator 450 Watt for ceiling fans and termination of wires to the switches
6 A Plug top with indicator.
Canopy for Ceiling Fans
Supply, Installation, testing and commissioning of following sizes of ceiling Fans and safety steel rope with 3 Core, 1.5 Sq.mm flexible copper cable of required length including earth connection as per the detailed specification and as directed by Engineer In charge. (Refer Sec VI, Clause No.17.1)
1400mm Sweep AC ceiling Fan
1200mm Sweep AC ceiling fan
Supply, installation, testing and commissioning of following sizes of Wall Mounting Exhaust Fans including supply of Aluminium grill bracket with Stainless Steel Bolts for mounting of Exhaust Fan & Aluminium grill bracket and 3 Core, 1.5 Sq.mm flexible copper cable of required length including earth connection as per the detailed specification and as directed by Engineer In charge(Refer Sec VI, Clause No.17.2).
150 mm dia.Exhaust Fan excluding aluminium grill
230 mm dia Medium duty, Double ball bearing exhaust fan.
300 mm dia Turbo Heavy Duty Exhaust Fan
Supply, testing and commissioning of following sizes of Pedestal fan / Air circulator as per the detailed specification and as directed by Engineer In charge.(Refer Sec VI, Clause No.17.3)
400mm sweep pedestal Fan as per the detailed specification. (Refer Sec VI, Clause No.17.3)
450mm sweep air circulator as per the detailed specification.
600mm sweep air circulator as per the detailed specification.
Supply, installation, testing and commissioning of following sizes of Wall Mounting Fans as per the detailed specification and as directed by Engineer In charge. (Refer Sec VI, Clause No.17.4).
450 mm sweep industrial wall mounting fan
400 mm sweep MAXX AIR TPW wall mounting fan
Supply, Installation, testing and commissioning of 1200mm Sweep BLDC Ceiling Fans and safety steel rope with suitable PVC insulated connecting wires including earth connection and as per the detailed specification and as directed by Engineer-in-charge.
Attending to break down faults in various types of Ceiling/Exhaust/Pedestal/Wall mounting /Air circulator Fans as per the detailed specification and as directed by Engineer In charge. (Refer Sec VI (MNC), Clause No.15).
Overhauling and Servicing of Ceiling / Pedestal / Wall Mounting / Exhaust / Air Circulator Fans (Single Phase) without Painting including supply of bearings as per the detailed specification and as directed by Engineer In charge.(Refer Sec VI (MNC), Clause No.14).
Overhauling and Servicing of Ceiling / Pedestal / Wall Mounting / Exhaust / Air Circulator Fans (Single Phase) with Painting including supply of bearings as per the detailed specification and as directed by Engineer In charge. (Refer Sec VI (MNC), Clause No.14).
Painting of Ceiling / Wall Mounting / Pedestal / Exhaust / Air Circulator Fans (Single Phase) as per the detailed specification and as directed by Engineer In charge. (Refer Sec VI (MNC), Clause No.3).
Identification of faults in 1200mm sweep BLDC motor ceiling fan, Supply and replacement of following defective accessories as per the detailed specification and as directed by Engineer In charge.
Identification of fault and replacement of BLDC fan controller PCB
Identification of fault and replacement of BLDC fan Stator winding assembly
Identification of fault and replacement of BLDC fan Remote
Supply, Fabrication and Installation of SS Grill with Aluminium frame as per Drawing No: GSO/ESG/ESD/KTS/EXF/SS GRILL/DRG-02 . For covering the opening of Exhaust Fan as per the detailed specification and as directed by Engineer In charge .
Supply and Installation of hot dip galvanised mounting bracket for ceiling fan as per drawing No:IGC/ESD/9170/8010 and the detailed specification and as directed by Engineer In charge. (Refer Sec VI, Clause No.17.5).
Cleaning of Ceiling / Pedestal / Wall mounting/Air circulator Fans/ fitted at different levels in various residential and non residential buildings as per the detailed specification and as directed by Engineer In charge . (Refer Sec VI (MNC), Clause No.14.2).
Maintenance of Earth Pits including supply of Sodium Bentonite, Painting and measurement of Earth Pit Resistance as per the detailed specification and as directed by Engineer In charge . (Refer Sec VI (MNC), Clause No.2).
Maintenance of Earth Pits and measurement of Earth Pit Resistance, Painting as per the detailed specification and as directed by Engineer In charge . (Refer Sec VI (MNC), Clause No.2).
Lifting of earth pit chamber up by 250mm aprox including earth excavation as per the detailed specification and as directed by Engineer In charge .
Supply and replacing following earth pit chamber parts after removing and disposing off old/damaged part as per drawing No. IGC/ESD/5060/1008/1.
RCC Top cover alone
RCC ring Collar alone
RCC ring with cover
Excavation in hard soil including refilling with excavated earth and disposing surplus earth at places as directed with in a lead of 10 Mtrs. and initial lift upto 1.5 Mtrs. including neat banking as per the detailed specification and as directed by Engineer In charge . (Refer Sec VI, Clause No.2)
SRIRAM ELECTRICALS (BID ID -3246814)
SAS ENTERPRISES (BID ID -3249338)
Bidder Name
SAS ENTERPRISES
MSE CONTRACTOR
SRIRAM ELECTRICALS
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .