Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹4.9 LAccepted-AOC 88 GIRRAJ NAGAR KALWAD ROAD JOTHWARA JAIPUR 302012 JAIPUR CITY NORTH RAJASTHAN 302012 | JAIPUR | RAJASTHAN | 302012 | L-1 | Accepted-AOC Tender accepted due to lowest tenderer | |
| 2 | L-2₹6.8 L+₹1.5 L (28.6%)Rejected-Finance | L-2 | Rejected-Finance Corrected amount of BOQ is Rs 681005 hence not being L1 | |
| 3 | L-3₹7.3 L+₹2.0 L (37.7%)Rejected-Finance | L-3 | Rejected-Finance Not being L1 | |
| 4 | L-4₹9.7 L+₹4.5 L (84.1%)Rejected-Finance | L-4 | Rejected-Finance Not being L1 | |
| 5 | L-5₹17.1 L+₹11.8 L (223.8%)Rejected-Finance C 56 6 ANAND VIHAR COMMERCIAL COMPLEX MAHOLI ROAD MATHURA UP PIN 281004 | MATHURA | UTTAR PRADESH | 281004 | L-5 | Rejected-Finance Not being L1 |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
27 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) Niwaru
AGE (I) Niwaru
AGE (I)) N - 38 OF 2022-23 REPAIR AND MAINT OF AC REFRIGERATION AND CONNECTED ITEMS AT NIWARU MIL STN UNDER AGE I NIWARU
2023_MES_578187_1
AGE(I)/N-38 of 2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
AGE (I) Niwaru
CLASS
6 documents required · 6 mandatory
₹500
Yes
AGE (I) Niwaru
₹20,000
Yes
6 Mar 2023
31 Jan 2023
1 Mar 2023
31 Jan 2023
27 Feb 2023
14 Feb 2023
Amount
Air-Conditioning Dismantling/taking down air conditioner 1.5TR/2TR capacity window type from any place and install the AC at another location after proper repair and testing complete all as specified and directed. Note:- All works such as window cutting, drilling holes in wall and applying insulation coating on copper pipe are deemed to be included in this rate. (Repair work and replacement of damaged parts shall be measured and paid seperately).
All as per above item No 01.00. but for AC 1.5/2TR split type
Servicing of 1.5TR/2TR capacity window type AC unit by cleaning with air pressure,tighting of bolts and nuts, arresting all leakages with necessary brazing/welding ensuring leak proof cleaning of condensor tubes ,checking of serviceability of fan motor,compressor,relay ,capacitors,PCB Coli,control circuit remote,sensor indicator electric circuits etc. ,incl labour for replacing of unserviceable parts except compressor and changing of refrigerant gas complete all as specified and as directed by Engr-in-charge. Notes : ( i) Replacement of compressor shall be measured and paid separately ( ii) Spare Parts required for replacement shall be measured separately under respective supply only items given here-in-after for item no. 26.01 & 32 to 36. ( iii) Gas will be measured and paid separately.
Supply only Blower Motor, single phase 230 Volts 1500 RPM, suitable for Window type AC 1.5-2 ton. Make : AUE / USHA
All as per above item No 03.00 but for AC 1.5TR/2TR capacity split type Note : Spare parts required for replacment shall be measured separately under respective supply only items given here in after for item No 06 & 11 to 15.00)
Supply only Blower Motor, single phase 230 Volts 1500 RPM, suitable for 1.5 -2.0 TR Split type Air Conditioner. Make : AUE / USHA or equivalent as per PS.
M/L for disconnecting and removing U/S sealed compressor unit from 1.5 TR capacity window type AC including supply and connecting with original sealed compressor unit all as specified and as directed by Engr-in-charge. (Make:- CARRIER/Voltas/Blue star/Usha-Daikin/LG/HITACHI/GODREJ)
All as per above item No. 07.00 but for AC 2 TR capacity window type
All as per above item No. 07.00 but for AC 1.5TR capacity split type
All as per above item No. 07.00 but for AC 2 TR capacity split type
Supply only Running capacitor 45 to 50 MFD 230 volts, 50 Hz for window/split AC. Make : KELTRON / USHA / SIEMENS
Supply only Starting capacitor 100 to 120 MFD 230 volts, 50 Hz for window/split AC. Make : KELTRON / USHA / SIEMENS
Supply only Plastic filter as per existing makes for Window/split type AC 1.5-2 ton capacity.
Supply only Over load protector relay suitable Window/split type AC 1.5-2 ton capacity. Make : SRIRAM / Ranutrol/ Indfoss
Supply only PCB coil suitable for Window/split type AC 1.5/2.0 ton capacity complete all as directed.. Make : LG/Carrier/Blue Star/Voltas/Fedder Lloyd
M&L for gas Freon-22(R22)/R 410a/ R32 all including filling of gas as directed by Engr-In-Charge..
M&L for gas R-134a all including filling of gas as directed and checked by Engr-In-charge.
Replacement of U/S remote control with existing make for Window/split type AC 1.5-2 ton capacity.
Refrigerator Checking of unservisable/ faulty Refrigerator (180 to 320) Ltr capacity installed in various locations for proper repair and testing of Fan motor, thermostatic switch, over load protector relay, box type relay, evaporator coil assembly etc. complete all as specified and directed by Engr-in-charge. ( i) Replacement of compressor shall be measured and paid separately ( ii) Spare Parts required for replacement shall be measured separately under respective items as supply only given here-in-after (20 & 23 to 26) ( iii) Gas will be measured and paid separately.
Supply only fan motor with existing make for refrigerator of capacity (180 to 320) Ltr all as specified and as directed by Engineer-in-Charge.
Supply and fixing in repair of compressor (sealed unit) with relay suitable for refrigerator of capacity (180 to 286) Ltr all as specified and as directed by Engineer-in-Charge. (Make of compressor Whirl pool / LG / GODREJ/Samsung/Voltas/Hitachi)
Supply and fixing in repair of compressor (sealed unit) with relay suitable for refrigerator of capacity 320 Ltr all as specified and as directed by Engineer-in-Charge. (Make of compressor Whirl pool / LG / GODREJ/Samsung/Voltas/Hitachi)
Supply only in replacement of Thermostatic switch with knob suitable for Refrigerator. Make : INDFOS / RENUTRAL or equivalent as per PS.
Supply only in replacement of over load protector relay suitable for refrigerator of capacity ranging from 180 to 320 Ltr all as directed by Engr-in-charge. Make : SRIRAM / Ranutrol/ Indfoss
Supply only in replacement of Box type relay suitable for refrigerator (180 to 320)Ltr capacity Engr-in-charge. Make : SRIRAM / Ranutrol/ Indfoss
Supply only in replacement of Evaporator coil assembly of existing make for refrigerator (180 to 320) Ltr capacity Engr-in-charge.
Supply & fix in repairs of Magnetic door gasket for refrigerator (180 to 320) Ltr capacity Engr-in-charge.
Supply & fix in repairs of freezer door for refrigerator (180 to 320) Ltr capacity Engr-in-charge. Make:- E Pack polymers or equivalent as per PS..
VOLTAGE STABILISER Re-winding the burnt/short circuited winding for Voltage stabilizer of 4/5KVA rating capacity single phase 230 Volts of any make with same gauge super enameled copper wire.
Re-winding the burnt/shourt circuited winding for Voltage stabilizer of 2KVA rating capacity single phase 230 Volts of any make with same gauge super enameled copper wire.
Re-winding the burnt/short circuited winding for Voltage stabilizer of 1KVA rating capacity single phase 230 Volts of any make with same gauge super enameled copper wire.
Supply and replace Unserviceable Plug and socket board with metal plug and socket (1 phase+neutral & earth) with 20 Amp rating DP MCB of make- Polycab with item code GPDPS10004 in accordance with IS 13032, IS 8623, IEC/BSEN 61439-3.or equivalent as per PS.
Supply and fix vegetable box for capacity 180 to 320 Ltr refrigerator complete all as specified and directed by Engr-In-Charge.
Supply and fix toughened glass for vegetable box for 180 to 320 Ltr capacity refrigerator complete all as specified and directed. ( Make:- As per existing make and capacity of refrigerator)
Supply and fix toughened glass bottle self of capacity 180 to 320 Ltr capacity refrigerator complete all as specified and directed. ( Make:- As per existing make and capacity of refrigerator)
Supply and fix Lamp with holder/Base plate and top toughened glass of capacity 180 to 320 Ltr capacity refrigerator complete all as specified and directed. ( Make:- As per existing make and capacity of refrigerator)
Supply only flexible Core PVC insulated with stranded copper conductor 1.5 Sqmm 600/1100 V ISI Marked all as directed. Make : Finolex,Havells or equivalent as per PS.
Supply only Flexible Core PVC insulated with stranded copper conductor 2.5 Sqmm 1100 V ISI Marked all as directed. Make : Finolex,Havells or equivalent as per PS.
Supply & fix condensate drin pipe for air conditioner
Supply & fix air conditioner copper pipe with insulated material
Shree Karni Electrovision
S.R.Enterprises
M/S TRADE LINKERS
Ms Kamal Kant Agarwal
Bidder Name
SHREE BHAGWATI ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .