| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.9 CrAccepted-AOC | ₹17.9 Cr | L1 | Accepted-AOC Awarded |
| 2 | L1₹17.9 CrRejected-AOC | ₹17.9 Cr | L1 | Rejected-AOC Rejected |
| 3 | L1₹17.9 CrRejected-AOC HOUSE NO 20 BAGHARBARI VIDYANAGAR 2 PANJABARI GUWAHATI ASSAM 781037 | KAMRUP METRO | ASSAM | 781037 | ₹17.9 Cr | L1 | Rejected-AOC Rejected |
| 4 | L1₹17.9 CrRejected-AOC | ₹17.9 Cr | L1 | Rejected-AOC Rejected |
| 5 | L1₹17.9 CrRejected-AOC | ₹17.9 Cr | L1 | Rejected-AOC Rejected |
Tender Value
₹19.9 Cr
EMD Value
₹39.8 L
Closing Date
19 Jan 2022, 2:00 pmClosed
Chief Engineer (Roads), PWRD, Assam
O/o the Chief Engineer (Roads), PWRD, Assam, Chandmari, Guwahati, 781003
RE_RIDF-XXVII_West Guwahati_01 Construction of road cum embankment from Dharapur to Mazirgaon of Brahmaputra River from Ch. 0m to 950.00 m (providing E/W, GSB, WMM, ICBP, protection work, traffic signs etc.) under RIDF-XXVII of NABARD for the year 2
2021_PWD_23865_2
CEDEV/RIDFXXVII/210/2021-22/01
Open Tender
Civil Works
540 days
West Guwahati
Please refer Tender documents.
6 documents required · 6 mandatory
₹10,000
Empowered Officer, Assam State Road Board
₹39.8 L
Yes
Development Branch, O/o the Chief Engineer (Roads)
15 Oct 2022
29 Dec 2021
19 Jan 2022
29 Dec 2021
19 Jan 2022
7 Jan 2022
29 Dec 2021 - 19 Jan 2022
5 Jan 2022
Amount
Clearing and grubbing of road land including up rooting rank vegetation grass,bush, shurbs saplings and trees of girth upto 300mm removal of stumps of trees cut earlier and disposal of unseviceable materials & stacking of serviceable material to be used or auctioned, upto a lead of 1000m including removal & disposal of top organic soil not exceeding 150mm in thickness. (I) By manual Means- (b) In area of non thorny jungle
Cutting of trees, including cutting of trunks, branches and removal of stumps & roots refilling compaction of backfilling and stacking of serviceable material by roots, refilling, compaction of backfilling and stacking of serviceable material by manual means with all lifts as per Technical Specification Clause 201. Lead upto 100 m. (i) Girth above 300 mm to 600 mm
Cutting of trees, including cutting of trunks, branches and removal of stumps & roots refilling compaction of backfilling and stacking of serviceable material by roots, refilling, compaction of backfilling and stacking of serviceable material by manual means with all lifts as per Technical Specification Clause 201. Lead upto 100 m. (ii) Girth above 600 mm to 900 mm
Removal of telephone/electric poles with wires including excavation and dismantling of foundation concrete and lines under the supervision of concerned department, disposal with all lifts and upto a lead of 1000 m and stacking the serviceable and unserviceable material separately as per Technical Specification Clause 202
Excavation for roadway in soil using manual means for carrying of cut earth to embankment site with a lift upto 1.5 m and lead upto 50 m as per Technical Specification Clause 302.3 (Manual method should be adopted where machines can not be deployed due to site condition)
Construction of embankment with material obtained from borrow pits, construction of embankment with approved materials obtained from borrow pits with a lift up to 1.5m, transporating to site, spreading, grading to required slope and compacting to meet required of tables 300.1 and 300.2 with a lead upto 1000m as per technical specification clause. (a) Private Land
Construction of sub-grade and earthen shoulders construction of sub grade and earthen shoulders with approved materials obtained from borrow pits with all lifts and leads, transporating to site, spreading, grading to required slope and compacting to meet required of table 300.2 with lead upto 1000m as per technical specification clause. (a) Private Land
(A) By mix in place Method -Construction of granular sub base by providing well graded material, spreading in uniform layers with motor grader on prepare surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification clause 401. (ii) For Grading Material (Gr-II)
Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406. By Mechanical Means with 1 km lead
Providing and laying interlocking concrete block pavement (M40) having thickness 80mm as per technical specification clause 1504 complete including carriage.(a) Including Edge block/ Edge restraint
Construction of RCC Guard Wall with saucer drain:- Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. I Ordinary soil Upto 3 m depth
Providing stone brick soling in earthen shoulder with stone/best quality jhama brick, sand packed and laid to true line and level and in panel after preparing the subgrade including earthwork in excavation as directed including all labour and materials and if necessary dewatering, complete. (a) Bricks on flat soling
Plain/Reinforced cement concrete, in open foundation complete as per drawing and technical specification including steel shuttering formwork. C (I)RCC Grade M20 Case I Using concrete mixer
Supplying, fitting and placing TMT IS:1786 (Fe 500) bar reinforcement in sub-structure complete as per drawing and technical specifications TMT-IS 1786 ( Fe-500 D) Secondary Producer (ISI approved)
PCC 1:3:6 in Foundation (Plain cement concrete 1:3:6 mix with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.)
Construction of Brick Masonry Drain:- Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. I Ordinary soil, Upto 3 m depth
Providing stone brick soling in earthen shoulder with stone/best quality jhama brick, sand packed and laid to true line and level and in panel after preparing the subgrade including earthwork in excavation as directed including all labour and materials and if necessary dewatering, complete. (a) Bricks on flat soling
PCC 1:3:6 in Foundation (Plain cement concrete 1:3:6 mix with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.)
Brick masonry work in 1:3 in sub-structure complete excluding pointing and plastering, as per drawing and technical specifications
Plastering with cement mortar (1:3 ) on brick work in sub-structure as per Technical specifications
Construction of single Shutter Sluice Gate:- 'Earthwork in excavation for structures as per drawing and technical specificationsClause 305.1 including setting out, construction of shoring and bracing, removalof stumps and other deleterious material and disposal upto a lead of 50 m,dressing of sides and bottom and backfilling in trenches with excavated suitable material. V. Marshy soil
Fillling in foundation trenches as per drawing and technical specification Clause305.3.9 I Sand filling
Brick on edge flooring with bricks of class designation 7.5 on a bed of 12 mm cement mortar, including filling the joints with same mortar, with common burnt clay non modular bricks: 11.1.2 1:6 (1cement : 6 coarse sand)
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 A With crushed Stone II P.C.C grade M 15Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 A With crushed Stone II P.C.C grade M 15
Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 A With Crushed Stone III RCC Grade M 20 i)For height upto 5 m
Centering and shuttering including strutting, propping etc. and removal of form for 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form work for : 5.9.2 Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Supplying, fitting and placing TMT IS:1786 (Fe 500) bar reinforcement in sub-structure complete as per drawing and technical specifications(a) TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/Jindal panther steel/ Shyam steel or equivalent)
Reinforcement in Super Structure: Supplying, fitting and placing TMTconforming to IS:1786 Fe 500 D reinforcement in super-structure including splicing complete as per drawing and technical specifications TMT-IS 1786 ( Fe-500 D) Primary Producer (TATA/ SAIL/ Esser Steel/ Jindal panther steel/ Shyam steel or equivalent)
Providing, driving with hydraulic piling rigs with power units and installing driven cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of shoe and the length of pile to be embedded in the pile cap etc. all complete. (Length of pile for payment shall be measured from top of shoe to the bottom of pile cap) : 20.1.3 500 mm dia piles
Vertical load testing of piles in accordance with IS 2911 (Part IV)including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. Note: 1. Initial and Routine Load Test shall not be carried out by Dynamic method of testing.
Supplying & driving vertical sheet pile complete as per drawing and technical specification (ISPS/1021)of size 4.50m width x 8.5mm thick weighing not less than 99.00 kg/sq.m.
12 mm cement plaster of mix : 13.4.1 1:4 (1 cement: 4 coarse sand)
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8. Granular material
Supplying , fitting & fixing of sluice shutter & construction of staging etc. complete as direcfted. ( 1 no for 2.20 m x3.00 m height clear epening , - Height of shutter will be of 3.70 m )
Construction of Stone Masonry Retaining Wall:- Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. I Ordinary soil, Upto 3 m depth
Dry rubble Flooring, Construction of dry rubble flooring at cross drainage works for relatively less important works.
Plain cement concrete 1: 3: 6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.
Stone masonry work in cement mortar 1:3 for sub-structure complete as per drawing and Technical Specifications. (A) Random rubble masonry
Plastering with cement mortar (1:3 ) on brick work in sub-structure as per Technical specifications
Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100mm dia AC pipe, extending through the full width of the structure with slope of 1 V:20 H towards drain face. Complete as per drawing and technical specification.
Back filling behind abutment, wing wall and return wall complete as per drawing and technical specification. (B) sandy materials
Retro reflectorised Traffic sign: Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M-15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand). (i) 90cm equilateral traingle
Retro reflectorised Traffic sign: Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M-15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand). (ii) 60cm equilateral traingle
Retro reflectorised Traffic sign: Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M-15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand). (iii) 60cm circular
Retro reflectorised Traffic sign: Providing and erecting of Retro-Reflectrorised cautionary, mandatory & informatory sign as per IRC: 67 made of high intensity encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick fixed on an angle iron of 25x25x4mm supported on a mild steel angle iron post 75mm x 75mm x 6mm firmly fixed to the ground by means of properly design foundation with M-15 grade Cement concrete 45cm x 45cm x 60cm, 60cm below ground level as per approved drawing and sign. ( All the Steel work must be Tata/Sail/or any other approved brand). (iv) 80cmm x 60 cm rectangular
Providing reflective pavement marker with Micro prismatic lens in both direction having thermoplastic body adhering to the specification and guidelines of MoSRT&H’s fixed to the road surface using the adhesives and the procedures recommended by the manufacturers with three months replacement warranty and free maintenance
Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes and conforming to the MoSrt&H specifications
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703. i) 5th kilometre stone (precast)
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703.ii) Ordinary Kilometer stone (Precast)
Reinforced cement concrete M15 grade kilometre stone/local stone of standard design as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703.iii) 200th meter stone (Precast) as per IRC:26-1967.
Construction for RCC gates for prohibition of movement of Heavy Vehicles as per approved designs:- Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. I Ordinary soil Upto 3 m depth
Providing stone brick soling in earthen shoulder with stone/best quality jhama brick, sand packed and laid to true line and level and in panel after preparing the subgrade including earthwork in excavation as directed including all labour and materials and if necessary dewatering, complete. (a) Bricks on flat soling
Plain/Reinforced cement concrete, in open foundation complete as per drawing and technical specification including steel shuttering formwork. C (I)RCC Grade M20 Case I Using concrete mixer
Plain/Reinforced cement concrete, in super structure complete as per drawing and technical specification including steel shuttering formwork. C (I)RCC Grade M20 Case I Using concrete mixer
Supplying, fitting and placing TMT IS:1786 (Fe 500) bar reinforcement in foundation complete as per drawing and technical specifications TMT-IS 1786 ( Fe-500 D) Secondary Producer (ISI approved)
Supplying, fitting and placing TMT IS:1786 (Fe 500) bar reinforcement in super-structure complete as per drawing and technical specifications TMT-IS 1786 ( Fe-500 D) Secondary Producer (ISI approved)
Providing and erecting direction and place identification retro-reflectorised sign, fixed over MS sheeting, 3mm thick with area exceeding 0.9sqm supported on a mild steel hollow bar 50mm x 50mm x 4mm supported on 200mm dia RCC column as per drawing and detailed specification
Lettering and arrow marks on signboard to be provided seperately as per actual requirement.
Plastering with cement mortar (1:3 ) on brick work in sub-structure as per Technical specifications
Painting Two Coats on New Concrete Surfaces Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered / concrete surfaces as per drawing and Technical Specification Clause 1701
RCC Guard Post: Supplying, fitting and fixing RCC guard post 150cm long erected 75cm above the ground and 75cm below the ground with M-15 grade (nominal mix 1:2:4 with broken stone aggregate up to 20mm size) of cement concrete and required reinforcement tied in position with annealed black wire including centering, moulding the top, curing including painting concrete surfaces in 23cm strips upto 0.75m from the top alternately in black and white and having 2 nos. reflective band of desired shade etc. complete as per design and as directed. b) 15 cm dia. RCC guard post with reinforcement of 4nos. 12mm dia TMT main steel bars and 6mm TMT/ MS stirrups at 15cm c/c
Turfing with Sods Furnishing and laying of the live sods of perennial turf forming grass on embankment slope, verges or other locations shown on the drawing or as directed by the Engineer including preparation of ground, fetching of sods and watering as per Technical Specification Clause 309.
ANIL DAS
MS Shiva Harlalka
Raju Mesh
North East Contractors Pvt. Ltd.
HABIBUR RAHMAN
Dhaneswar Kalita
MS G L Agarwalla
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid