Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.5 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 bidder | |
| 2 | L2₹8.0 L+₹35,236 (4.61%)Rejected-Finance AT DUNGAMAL NH 5 POST NB CHILKA VIA BALUGAON DIST KHURDA ORISSA 752037 | KHORDHA | ODISHA | 752037 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹8.1 L+₹40,815 (5.34%)Rejected-Finance PLOT NO 8 5179 SAILASHREE VIHAR CHANDRASEKHARPUR BHUBANESWAR DIST KHURDA ODISHA 751 021 | KHORDHA | ODISHA | 751021 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹8.3 L+₹67,195 (8.79%)Rejected-Finance AT AMRITPUR PO NB CHILKA DIST KHURDA ODISHA 752037 | KHORDHA | ODISHA | 752037 | L4 | Rejected-Finance Being L4 |
Tender Value
₹8.8 L
EMD Value
₹17,500
Closing Date
12 Oct 2021, 6:00 pmClosed
Shri Avinash Mishra IDSE GE
Garrison Engineer (I) (CG) Bhubaneswar Near NTPC Guest House Post Pokhariput Bhubaneswar 751020
REPAIR AND MAINTENANCE OF INTERNAL ELECTRIFICATION AND EXTERNAL ELECTRIC SUPPLY WATER SUPPLY DG SET AND TRANSFORMER ETC
2021_MES_475196_1
8253/BBSR/05/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Gopalpur
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE (I) (CG) Bhubaneswar
₹17,500
Yes
29 Oct 2021
14 Sept 2021
15 Oct 2021
14 Sept 2021
12 Oct 2021
28 Sept 2021
15 Sept 2021 - 25 Sept 2021
Amount
Taking down carefully by unscrewing from boards/outlet boxes,fittings and fixture such as switchs, socket, ceilling roses, lamp holder, brackets,ceilling fittings, bulk head fittings, light fittings etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions seperately and and making good the disturbed surface of ealls, floor,ect complete all as specified and directed.
S&F for switch piano 5 Amp flush type one way single pole 230 Votls, 50 Hz, AC complete all as specified and directed. ( Make - Anchor/ Havells or Equivalant)
S&F for celing rose surface backlite with 2-3 terminal 65x30mm 230 Votls, 50 Hz, AC complete all as specified and directed. ( Make - Anchor/ Havells or Equivalant)
S&F for switch socket combination 5 Amp flush type 2 in 1 type, 3 pin, flush type 230 volt 50 Hz, AC complete all as specified and directed. ( Make - Anchor/ Havells or Equivalant)
S&F for switch socket combination 5/16 Amps flush type universal 5 in 1 type, 5 pin, flush type 230 volt 50 Hz, AC complete all as specified and directed. ( Make - Anchor/ Havells or Equivalant)
S & F for Ding Dong type Bell, AC, 230V,50 Hz, AC complete all as specified and directed. ( Make - Anchor/ Havells or Equivalant)
S & F switch bell/Buzzer push,flush type 5 Amp, 230Volt, 50 Hz, AC complete all as specified and directed. ( Make - Anchor/ Havells or Equivalant)
S&F stepped type electronic fan regulator stepped socket type ,100W ,230V ,50Hz, AC complete all as specified and directed. ( Make - Anchor/ Havells or Equivalant)
S&F in repair of Capacitor for ceilling fan 2.5 Mµ switable for 1200 mm sweep complete all as specified and directed. ( Make - Bajaj / Crompton or Equivalant)
S&F in repair of Capacitor for Exhaust fan 4.0 Mµ switable for 230 mm sweep complete all as specified and directed. ( Make - Bajaj / Crompton or Equivalant)
Taking down ceiling / Exhaust fan, sealing cable end, dismantling blades and removing fan and blades for repair and rewinding refixing the same complete all as specified and directed. (Note : Rewinding item will be measured & paid separately)
S&F for rewinding of ceiling fan of1200 mm sweep including taking down after re-winding, oiling, greasing and re-fixing complete all as specified and directed.
All as per Item No. 12 but for one exhaust fan of sweep 300 / 450 mm Sweep
S & F in repairs Bush / Ball bearing (type - Single row deep groove ball bearing) for ceiling fan 1200mm sweep bearing no -6201/ 6202 or as per sample complete all as specified and directed. (Make - TATA / SKF)
S & F in repairs of MCB SP 6 to 32 Amp, 10 Ka, C series , 230 Volts, AC complete all as specified and directed. (Make - Havells / L&T/ Legrand).
S & F in repairs of MCB SPN 6 to 32 Amps, 10 Ka C series, 230 Volts, AC complete all as specified and directed. (Make - Havells / L&T/ Legrand)
S & F in repairs of MCB TPN 10 Ka "C" series 415 Volt 40 to 63 Amps, AC complete all as specified and directed. (Make - Havells / L&T/ Legrand)
Supply and fixing in repairs of LED T-5 Batten type tube light fitting of 20 watt suitable for surface and wall mounted with polycarbonate and integrated LED drive including twin core twisted flexiable copper conductor cable of size 1 sq mm from connector to ceilling rose complete all as specified and directed. (Make:- Surya Cat Part No. SLE BT 20IL or equivalent in Wipro/ Phiiips/ Havells)
S&F for A new generation LED T5 atten application 09/10 W LED 6500 K LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready including twin core twisted flexiable copper conductor cable of size 1 sq mm from connector to ceilling rose complete all as specified and directed. Make:- Surya Cat No SLE BT 9 W Arrow or equivalent in Wipro/Phillps/ Havells)
Supply and fixing in repairs of energy saving environmental friendly, long life LED Lexon Street light fitting 45 watt made of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperete driver compartment with IP 66 protection including taking down old unserviceable light fitting complete all as specified and directed. (Make :Surya Cat Part No.SLE UL 45W IP66 (LXN) or equivalent in Philips/ Havells)
Taking down of Street light fitting complete of Cap 45 / 40 Watt LED street light including repair and replacement of Electronic Driver as per required and refixing the same existing position complete all as specified and directed.
Supply and Laying inreplacement of XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 16 Sq mm 4.0 core in trenches or fixed on wall/floor/poles complete all as specified and directed.
Excavation in trenches in soft/loose soil n.exc 1.5m wide and n. exc 1.5m depth getting out of soil for taking out or laying of pipe line etc complete all as specified and directedfor laying of cable, errection of poles, stay and pipe line, complete all as specified and as directed.
Returning & filling including spreading, leveling watering and well ramming in layers n. exc 25 cm thick in any type of soil complete all as specified and directed.
Removal of surplus soil to a distance n. exc 50 m above the starting point complete all as specified and directed.
M & L for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed.
Supplying & Laying Sub Class `B’ bricks, old size, kiln burnt, laid with axis of brick perpendicular to the axis of the cable, for protection of cable complete all as specified and directed.
Supply and fixing in repairs of MCCB 3 pole , 200 amp rating of 35 KA on existing LT panel board including dismantling and taking out of old unserviceable MCCB from the LT panel board complete all as specified and directed. ( Make : Legrand Cat No 420238 or equivalent of ABB/Schnieder/L&T/Havells)
Taking up/down GI tubing from trenches , duct, wall, roof or in any position with all fittings for re-laying /refixing of serviceable pipes and removing the unserviceable pipes for 50 mm dia complete all as specified and directed.
All as per item No 29 above but 25 sqmm dia complete.
Supply and fixing of GI tubing medium grade of 25 mm dia fixed on wall/floor etc complete with necessary clamp, nut, bolts and washers and socket and making good the disturbed surface of wall , floor or roof etc complete all as specified and directed.
All as per item No 31 above but 50 sqmm dia complete.
Supply and fix in repairs of Valves, Sluice, flanged of class 1.6 PN ,80 mm (3”)dia complete all as specified and directed.
Supply and fix in repairs of Gun-metal, globe or gate valves 50 mm dia,with iron wheelhead, screwed both ends for iron pipe and fixed complete all as specified and directed.
Supply and fix in repairs of Gun-metal, globe or gate valves 25 mm dia,with iron wheelhead, screwed both ends for iron pipe and fixed complete all as specified and directed.
Supply and fix in repairs of Non Return Sluice Valve 50 mm dia of class 1.6 PN complete all as specified and directed.
Re-laying old serviceable GI tubing after throughly cleaned the inside of pipes and re-running the old screws threads as required and re-fixed/re-laying in trenches wall or roof etc complete for 50 mm dia complete all as specified and directed.
All as per item No 37 above but 25 sqmm dia complete.
Servicing of authorised agency "B" check in replacement of Lube oil(15W40). fuel filter, Oil filters, Coolant top up will be done. Under 'C' Check " B- Check activities will be done along with Air filters replacement,Tapped set replacement if required ( Opening, adjusting, tightening of tappet cover complete by torque wrench by applying proper pressure , cleaning of complete sump from sludge of dirt, oil) etc and refitting for DG set including drain out (used) engine oil and filling new engine oil of Capacity 62.5 KVA Gen Set complete all as specified and directed. Note:- (a) Engine oil, Air Filter, Fuel Filter, Oil Filter to be measured and paid separately as supply only under respective items of schedule 'A'.
Supply only engine oil suitable for diesel generator set (Oil 15W/40) complete all as specified and directed. Make: Servo/ HP / Bharat Petroleum.
Supply only coolant suitable for radiator of DG sets complete all as specified and directed. Make: HP/TVS or Equivalent.
S/F in repairs of battery terminal brass(heavy duty)with nuts & bolts for battery (as per sample) complete all as specified and directed.
S&F Fuel Filter as per sample as required at site complete all as specified and directed. Make:- Greaves, TVS or Equivalent.
S&F Oil Filter as per sample as required at site complete all as specified and directed. Make:- Greaves, TVS or Equivalent.
S&F Air Filter as per sample as required at site complete all as specified and directed. Make:- Greaves, TVS or Equivalent.
Supply in repairs of battery 12 Volt 150 AH with terminals for DG Set complete all as specified and directed
Repair of Self Starter 24 volts/12 volts DC, disconnecting and dismantling and repairing with replacement of bendex-01,Rewinding of armature, Field coil, Carbon Bush etc reassembling and refitted at its original position including testing of the complete self starter of Capacity 62.5 KVA Gen Set complete all as specified and directed.
Supply, heating and topping up transformer insulating oil EHV grade having dielectric strength not less than 60 KV (R.M.S) at 2.5 mm gap high viscosity confirming to IS–335 of 1983 complete for replacement of unserviceable transformer oil or for toping up complete all as specified and directed.
M&L for complete routine test of transformer of Cap 160 KVA (as per IE rules) with authorised agency once in 6 month as per the dirction of Engr-in-Charge and submit the all routine test certificate by the authorised agency to Engr-in-Charge for maint of our record of any cpacity of trnasformer complete all as specified and directed.
Supply and Repairs of fresh silica Gel complete all as specified and directed.
S & F in repairs of electronic balast suitable for 24 T-5 Watt complete all as specified and directed. (Make : Surya Cat No SEB-124-ISP3/Crompton Greaves/ Phillips/Bajaj/)
Cleaning ,servicing ,painting ,writing SM.MES No including minor repair work if required and greasing of all moving parts i.e pump impeller , stainless steel shaft, bearing & rubber coppling etc for smooth running and replacement of packing gaskets, shaft sleeve, neck ringnut bolts and washers etc, with necessary oiling and greassing of 12.5 HP pump complete all as specified and directed.
Cleaning ,servicing ,painting ,writing SM.MES No including minor repair work if required and greasing of all moving parts i.e pump impeller , stainless steel shaft, bearing & rubber coppling etc for smooth running and replacement of packing gaskets, shaft sleeve, neck ringnut bolts and washers etc, with necessary oiling and greassing of 5.0 HP pump complete all as specified and directed.
Supply only ball bearing 6310-ZZ/C3 complete all as specified and directed. Make:- (SKF, TATA)
Supply only ball bearing 6206-ZZ complete all as specified and directed. Make:- (SKF, TATA)
Cleaning and removing yearly all scales and deposited materials in Under ground water sump of 50000 liters capacity by applying bleaching powder , brushes for removing deposited materials, including jungle cleaning to sourrounding area including draining out existing water complete all as specified and directed. Note :- The cost of coir rope, bleaching powder, brush for removing scales & cleaning the surrounding area near tank and dumping the mud outside the premises & writting date of cleaning, tank capacity shall be deemed to include in the above item rate.
Cleaning and removing yearly all scales and deposited materials in Overhead tank 50000 liters capacity by applying bleaching powder , brushes for removing deposited materials, including jungle cleaning to sourrounding area including draining out existing water complete all as specified and directed. Note :- The cost of coir rope, bleaching powder, brush for removing scales & cleaning the surrounding area near tank and dumping the mud outside the premises & writting date of cleaning, tank capacity shall be deemed to include in the above item rate.
S&F in repairs of Brass Foot Valve for suitable of 50 mm dai GI Tube complete all as specified and directed.
M&L for repair, cleaning and servicing of automatic star delta starter of capacity 15 HP fixed in existing LT panel including tightening of all loose coonection and replacement of minor defective parts such as cable lugs, nut bolts PVC copper connection wire etc to make the starter serviceable complete all as specified and directed. (Note : Major defective parts will be measured and paid separately under relevent item as supply only)
S & F in repairs of floursent tublar lamp 28 T-5 watt complete all as specified and directed. (Make :Crompton Greaves/Phillips/Bajaj/)
Supply and fixing in repairs of MCCB 3 pole , 100amp rating of 16 KA on existing LT panel board including dismantling and taking out of old unserviceable MCCB from the LT panel board complete all as specified and directed. ( Make : Legrand Cat No 4200-05or equivalent of ABB/Schnieder/L&T/Havells)
S&F for bldg sesurity light Endura cItylIte platInum plus sl 25W LED energy saving and environmental friendly long life 25 Watt LED light made up of pressure die cast aluminium housing with high power led as lighting source and lens embedded PC cover having iP65 protection and impact resistance of iK07 with 10KV Built-in surge Protection device including twin core flexiable copper conductor cable of size 1.5 sq mm from connector to light point complete all as specified and directed. Make:- Surya Cat No SLE-UL-25W-IP66(LXN), or equivalent of Havells/Crompton / Bajaj/ Phillps)
Taking down of LED Bldg security light fitting of Cap 25 / 20 Watt repair and replacement of Electronic Driver as per required and refixing the same existing position complete all as specified and directed.
Dismantling and taking down of motor from pump after disconnection of mechanical tyre coupling and unbolting from foundation base plate,discconection of electric connection from terminal loading/unloading the motor to vehicle and transportation of the motor to workshop, cutting the burnt winding and clean the rotor & stator with CTC or other cleaning matterial and rewinding of stator winding with supper enameled copper wire as per existing the size/gauge wire and turn of the previous winding, insulating the leads with insulating tubes and varnishing the stator with good quality of insulating varnish . Afterward heating the stator in heat chamber for continous 2 days for better insulation resistance reassembling the stator & rotor carefully after replacement of worn out bearings, transportation of motor from workshop to its original location, unloading the motor and placing it on base frame, connection of motor with pump with tyre coupling and fixing to the base frame after checking up the alignment, testing of motor with megger for checking of insulation resistances, electric connection of motor to the control panel, testing on load for continous running for 3 hrs of capacity 12.5 HP Induction motor complete all as specified and directed.
Dismantling and taking down of centrifugal pump after disconnecting from motor , mechanical tyre coupling, suction/discharge pipe line and unbolting from foundation base plate loading/unloading the pump to the veh and transportation to workshop for repair/replacement/maint and incl dismantle & re-assembling the pump set, including necessary lathe/grinding work of stainless steel shaft , housing , impeller for smooth running and replacement of packing gaskets etc. after repair/replacement/maint transportation the same back from workshop to site, including re-assembling , recoupling the pump with motor on base frame, checking the alignmment with motor, testing & commisioning on completion and checking upto the satisfaction of Engr-in-Charge of capacity 12.5 HP complete all as specified and directed. Note :- [i] unserviceable spares parts of pump set (like bearing, shaft, impeller), will be measured and paid separately.
Supply & fixing backup system 2 KW including thermostate 230V in all tank inreplace of damage backup system and also all electric connection including MCB DB four way complete all as specified and directed.
Repair of hot water pipe lines and existing other hot water tanks incl. stoping leakage of water, damage of packing , discaling and checking of all pipe lines in all respect for satisfactory working of hot water system complete all as specified and directed.
Repair of LT pannel board such as repair of locking arrangement, door hinges etc by welding, removal of burnt MCCBs, MCBs, LED Indicator lamps Voltmeter, Amperemeter & burnt wiringetc and refixing new items after cleaning ( MCCBs, MCBS, Voltmeter & Amperemeter paid separetly), and also painting the panel boardwith one coat of super enamelled paint of approved colour by spraying machine incl preperation of old surface complete all as specified and directed.
Supply and fixing in repairs of Ammeter digital (0-100)Amp, 3 phase along with CT's complete on existing LT panel board complete all as specified and directed. ( Make : L & T Cat no WL1310200000 or equivalent)
Supply and fixing in repairs of Voltmeter digital type with of (0-440) Volt 3 Ph on existing LT panel board complete all as specified and directed. ( Make : L&T Cat No WL 2320200000, Legrand or equivalent in ABB/Schnieder)
M/L for earthing complete with galvanised steel plate earth electrode of size 60cmx 60cmx6mm thick, burried in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of the plate not less than 1.5 m below normal ground level, connected with GI wire 4 mm dia earth lead by means of nuts, bolts,check nuts and washers and galvanised iron of steel 15mm bore pipe medium grade for protection connected to main switch board or main control board all as specified and directed including , 20mm dia GI pipe medium grade for watering,funnel with wire mesh, PCC pit with RCC cover including necessary earth work excavation and removal etc complete all as specified in plate No 3 of SSR Part-I 2009 and complete all as specified and directed.
Testing of earth value of all installed earthing of ICGS area by disconnecting from the load and submit the report complete all as specified and directed.
HARI HARA NAYAK
SMART ENERGY SOLUTIONS
PABITRA MOHAN PARIDA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .