| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.2 LAccepted-AOC SWAGAT CO OP HSG SOCIETY LTD 22 303 CHAITANYA SHIVAJI RAJE COMPLEX MHADA COMPLEX OPP EKA NAGAR KANDIVALI W MUMBAI 400 067 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400067 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹27.6 L+₹5.4 L (24.1%)Rejected-AOC 1101 A WING SACHDEV COMPLEX JANGAL MANGAL RAOD BHANDUP W MUMBAI 400078 | MUMBAI SUBURBAN | MAHARASHTRA | 400078 | L2 | Rejected-AOC NOT LOWEST | |
| 3 | L3₹28.5 L+₹6.2 L (28.0%)Rejected-AOC FLAT NO 301 PEARL APARTMENT PLOT NO 121 SECTOR 8A AIROLI NAVI MUMBAI 400708 | NAVI MUMBAI | THANE | MAHARASHTRA | 400708 | L3 | Rejected-AOC NOT LOWEST | |
| 4 | L4₹39.5 L+₹17.3 L (77.6%)Rejected-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L4 | Rejected-AOC NOT LOWEST |
Tender Value
₹48.8 L
EMD Value
₹97,600
Closing Date
29 Apr 2024, 6:00 pmClosed
GE (NW) MANKHURD
GE (NW) MANKHURD, MUMBAI 400088
REP/MAINT OF INTERNAL ELECT, SECURITY LIGHTS, GARDEN LIGHTS INCL COOLING, SUMMER APPLIANCES FOR OFFICE ACCN AND DOOR TO DOOR DAILY COMPREHENSIVE REP/ REPLACEMENT OF MISC ELECTRICAL ITEMS FOR MD ACCN AT SEWRI, MAHUL , THANE , 31 WEU UNDER GE(NW) MKD
2024_MES_648811_1
8341/E8
Open Tender
Civil Works
Item Rate
180 days
GE (NW) MANKHURD
AS PER NIT AND TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE (NW) MANKHURD
₹97,600
3 Sept 2024
1 Apr 2024
1 May 2024
1 Apr 2024
29 Apr 2024
13 Apr 2024
Amount
Disconnecting & Taking down ceiling fan 1200/1400 mm sweep any make from any position at site transporating to MES store Yard & dismantling blades opening the stator and rotor of ceiling fan and providing new lubricating, grease in bearing/bushes, re-assembling, commissioning and testing complete & rehanging fan to site incl providing nuts, bolts, locking bolts, blades screws, split pin, rubber real, PVC connector, washers where required and refixing in same position complete all as directed by Engineer-in-charge. (a) Upto 4 Meters height. Note:- All major rerpair such as replacement of Bush, bearing , condensor, shaft, connection wire , winding & painting will be measured & paid separately under S&F /M&L items here-in-after
Supply only ball bearing (No 6201, 6202 & 6203) suitable for Ceiling fan 1200mm/1400mm suitable as per site requirements. Make : SKF, TATA, NBC
M&L for removing of burnt winding from ceiling fan stator of size 1200mm/1400mm sweep and rewinding the same with equal gauge of super enameled copper winding wire, insulating paper, varnishing and testing complete incl transportation to contractor's work shop and bringing back to store and testing complete.
M&L for scraping all foreign materials with emery paper, cleaning the body, blades, legs, frame and down rod (preparatory work) for painting ceiling fan and painting with one coat of supper enameled white paint (spray paint)/grey paint and writing of MES No. with capital letter of size 20 mm height and 03 mm width with synthetic enameled black paint for Ceiling fan 1200mm/1400mm sweep all as directed.
S&F in repair of gun metal bush suitable for ceiling fan as per site requirements complete
Supply and fixing condenser 2.5 MFD with PVC clamp.
Supply & fix PVC canopy of 1200/1400 mm sweep ceiling fan.
Taking down the ceiling fan, remove the down rod, Material and Labour for provisioning of new down rod made out of GI tubing medium grade cutting, threaded and holes drilled both ends (dual arrangement), making holes – 02 Nos, painting with two coats of synthetic enamel white colour paint, fixing the down road to the fan and re-hanging the fan complete including their electric connections as directed. Note- GI tubing will be measured and paid separately under S&F item here-in-after.
S& F GI tubing 15 mm bore medium grade ISI marked.
S& F GI tubing 40 mm bore medium grade ISI marked for fixing on walls including PCC 1:3:6 type C-1 block 230x230x150 mm for grouting ends of pipe & all fittings for hanging of Ceiling fans complete all as directed.
M&L for fan hook made out of MS flat 50x6 mm suitably shaped to mount on 40 mm dia GI pipe including welded MS bar 10 mm dia half round shaped & necessary nuts & bolts complete all as directed.
S & F in repair of celing fan shaft complete of size & quality as per existing all as directed by Engr-in-charge.
S & F in repair for replacement of U/S stator block made of laminated sheets of size and quality as per existing all as specified and directed by E-in-C
S&F fan blade set (set of three) made out of aluminium sutaible for 1200 mm sweep ceiling fan, as per exisitng size and guage all directed by Engr-in-Charge .
Taking down Exhaust fan/wall fan/Pedestal fan/ air circulator any make any size from any position at site transporating to MES store Yard & dismantling blades opening the stator and rotor of fan and providing new lubricating, grease in bearing/bushes, reassembling, commissioning and testing complete & refixing fan to site incl providing nuts, bolts, locking bolts, blades screws, split pin, rubber reel, PVC connector, rubber pad, washers where required and refixing in position complete all as directed by Engineer-in-charge. Note:- All major rerpair such as replacement of Bush, bearing , condensor, shaft, connection wire, winding & painting will be measured & paid separately under supply only items here-in-after
S&F in repair PVC insulated three core 0.75 Sqmm size wire copper conductor 1100 Volt grade.
Material and Labour for removing of burnt winding from Exhaust Fan 9” sweep, rewinding the same with equal gauge of super enameled copper winding wire, insulating paper, varnishing and testing complete incl transportation to work shop and bringing back to store and testing complete.
-Ditto- all as per item No 17 above but Exhaust Fan 12” sweep.
-Ditto- all as per item No 17 above but Wall Mounted Fan 16” sweep.
-Ditto- all as per item No 17 above but Pedestal Fan 16” sweep.
M&L for scraping of Exhaust fan 9" to 16" Sweep all foreign materials with emery paper, cleaning the body, blades, legs, frame and down rod (preparatory work) for painting of exhaust fan/air circulator fan/pedestal fan and painting with one coat of supper enameled white paint (spray paint)/grey paint and writing of MES No. with capital letter of size 20 mm height and 03 mm width with synthetic enameled black paint all as directed.
Material and Labour for making circular holes suitable for fixing of 12” sweep Exhaust fans by cutting the wall any thickness required circumstances for exhaust of air and including grouting of rag bolts and nuts complete including finishing of disturbed surfaces by using cement mortar 1:3 complete all as required at site and directed by the Engineer-in-Charge.
Supply and fixing in repair of wall mounted fan blade suitable for 400 mm sweep fan as per existing complete all as directed by Engr-in-Charge.
S&F exhaust fan MS blade 9” to 12” as per existing complete all as directed by Engr-in-Charge.
S & F in repair for MS front frame suitable for mounting of stays of 9" exhaust fan made out of MS Sheet not less than 1.6mm thick painted with two coat of synthetic enamelled paintover a coat of red oxide zinc chrome primer complete with neccesarry fixing accessories such as nut, bolts washers etc & fixing to wall all as per existing & site requirement as directed by Engr-in-charge.
-Ditto- All as per Item No 25 above but suitable for 12" exhaust fan -do-
S & F in repair for circular / rectangular framed shutters suitable for 9" exhaust fan made out of MS sheet not less than 1 mm thick for frame & not less than than 0.6 mm thick for shutter painted with two coat of synthetic enamelled paint over a coat of red oxide zinc chrom primer complete with neccesarry fixing accessories all as per existing & as per site requirement & directed by Engr-in-charge.
-Ditto- all as per Item No 27 above but suitable for 12" exhaust fan -do-
S & F in repair of exhaust fan shaft complete of size & quality as per existing all as directed by Engr-in-charge.
Disconnecting & taking down existing defective storage water heater 25 ltr capacity for repairs work such as replacing defective parts and fixing back in position in replacing the necessary nuts and bolts including painting with two coats of white synthetic enameled paint by spray paint complete all as specified and directed by the Engineer-incharge
S&F in repairs safety valve for geyser chromium plated brass 15mm dia all as specified and directed by the Engineer-incharge.
S&F in repairs non return valve chromium plated brass 15mm dia all as specified and directed by the Engineer-incharge.
S&F in repairs Indicator lamp red/green, round/sqare/rectangle for geyser as per site requirement 230V AC all as specified and directed by the Engineer-incharge.
S&F in repair of plug top 3 pin 15/16 Amps capacity
S&F in repair of plug top 3 pin 5 Amps capacity
S&F in repair inner stainless steel dome of geyser of capacity 25 ltrs complete as per sample to match original patterns and shape.
S&F in repair heating elememt 2000 watt threaded or push type as per the existing one suitable for vertical storage water heater of any size all as specified and directed by the Engineer-incharge.
--- ditto --- all as per item above but 3000 watt
Dismantling and taking down the existing defective street light fitting of any type and any capacity LED 25 W to 70 W from steel tubular pole, opening the street light fitting, checking the serviceability of spare parts including replacement of defective parts such as drivers, cables, mounting Nut bolts etc after repairing including refixing on pole including connecting & testing complete all as directed by Engr-in-Charge. [Note:- Electronic drivers will be measured and paid separately on respective item of Sch 'A' here-in-after].
S&F in repair of building Security light fitting made up of pressure die cast alluminium body with mid power 60 Watt LED (PINNACLE PLUS) as lighting sources and PC cover having Top opening seperate driver compartment with IP66 protection Including fixing arrangements and taking down old rusted bracket fittings complete all as per directed by Engr- in – charge. Make - Havells/ Crompton /Bajaj/Benlo
S&F in repair of building Security light fitting 35 Watt made up of pressure die cast alluminium body with mid power LED as lighting sources and PC cover having Top opening separate driver compartment with IP66 protection and impact resistance of IK07including fixing arrangements and taking down old rusted bracket fittings complete all as per directed by Engr- in – charge. Make :- Crompton/ Bajaj/ Phillips/ Jaquar/ Wipro
S& F in replacement of GI steel tubing medium grade 40 mm dia and length up to 1.5 meter bent to shape of offset angle upto 45degree for fixing of security /street light fittings including MS clamps made of 40mm x 6mm flat iron, nuts , bolts, etc all as directed by Engineer in charge
S & F in repair of LED Driver 200 watts to 350 Watts Suitable for highbay/flood/street light fitting, driver Shall Conform to Cat no X075C070V107FNY1BO of Crompton or Equivalent from Philips/Bajaj
S & F in repair of LED Driver 30 to 60 Watts Suitable for street light/2'x2' 36 watt fitting, driver Shall Conform to Cat no S0DQL1-54-700-40Wof Crompton or Equivalent from Philips/Bajaj
Supply and fixing post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection die cast aluminium spigot with spun aluminium top duly powder with PC diffuser & PMMA clear diffuser from outside with impact and corrosion resistant complete with driver and lamp complete. . Make - Havells/ Crompton /Bajaj
Supply and fixing post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection die cast aluminium spigot with spun aluminium top duly powder with PC diffuser & PMMA clear diffuser from outside with impact and corrosion resistant complete with driver and lamp complete. . Make - Havells/ Crompton /Bajaj
Supply & Fix 9/10 watts LED Bollard Garden light fittings with efficient high output LED, Pressure die cast powder coated housing with PCdiffuser , driver nuts, bolt, washers, base plate, complete., The fitting shall conform to Cat No PGR0301007 of Polycab or equivalent Havells /Crompton
S & F in repair UP-down light fitting 10 -12 Watts LED, IP 65, 230 Volts, including drivers, pressure di cast aluminium housing, prewired complete.
Supply and fixing round shape LED Downlighter, 15 - 18 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete. Make : Jaquar/ Wipro/ Crompton/ Bajaj
Supply and fixing round shape LED Fency Spot Light, 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete.Make Shakti Cat No. SZRDMX015 or equivalent of Crompton/Havells as approved by GE
Excavation in trenches not exceeding 1.50 m wide and n.exc 1.5 m in depth for foundation of poles, cable etc, not exc 10 sqm on plan and getting out in soft/loose soil including taking out brick protection etc complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick complete all as specified and directed.
Removing excavated materials (soils) not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed.
M & L for sand cushioning by spreading in trenches crushed sand by gently by punning down manually as in cable protection all as specified and as directed by Engineer -in-charge.
Supply and laying un-reinforced precast concrete cable cover class LV, type-I, flat size 250 mm x 150 mm x 40 mm laid in trenches all as specified.
Supply & Lay XLPE insulated, heavy duty 1100 volt grade electric LT UG cable ISI marked with aluminium conductor of size 10 Sqmm 4 Core in trenches/along the wall/including takingdown old unsv cable and making all connections complete with lugs as required at site and as directed by Engr-in-Charge.
Supply & fix in repairs UPVC panel trunking of suitable size as per ground requirement including spacers, screws, saddles for fixing the trunking in wall/GI sheets of shed.
Supply & Lay XLPE insulated, heavy duty 1100 volt grade electric LT UG cable ISI marked with aluminium conductor of size 4 Sqmm 4 Core in trenches/ including saddles & spacers for clamping the cables along the wall and takingdown old unsv cable and making all connections complete with lugs as required at site and as directed by Engr-in-Charge. Make - KEI/ Polycab/ Havells
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300 mm sweep with, blades, and frame and louvers complete all as specified and directed. Make :- ALMONARD / ORIENT
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250m complete all as specified and directed. Make :- ALMONARD / ORIENT
M&L in repair sub main wiring with two single core PVC-FRLS insulated unsheathed multistranded copper conductor cable of size 6 sqmm drawn in PVC casing caping with 6 Sqmm PVC-FRLS insulated unsheathed multistranded copper conductor as a continuous earth wire complete all as specified. Make - KEI/ Polycab/ Finolex/ Anchor/ Benlo Note : Two single core cable one run of earth copper conductor & one run of PVC casing & caping will be measured and paid as one unit length.
M&L in repair sub main wiring with two single core PVC-FRLS insulated unsheathed multistranded copper conductor cable of size 2.5 sqmm drawn in PVC casing caping with 2.5 Sqmm PVC-FRLS insulated unsheathed multistranded copper conductor as a continuous earth wire complete all as specified. Make - KEI/ Polycab/ Finolex/ Anchor/ Benlo Note : Two single core cable one run of earth copper conductor & one run of PVC casing & caping will be measured and paid as one unit length.
M & L For Taking down of LT XLPE insulated, armoured heavy duty 1100 volt grade electric cable with aluminium conductor of size 2 Core 10 Sqmm to 3.5 Core 35 Sqmm from wall/Roof/steel Structures of buildings/Storgae Sheds etc and refixing the same in position after replacing of Saddles & Spacers all as directed by Enginner incharge including replacing of cable glands, lugs & making all connections complete as required at site and as directed by Engr-in-Charge -
Material and labour for carrying out vaccum test, pressure test and detecting leakage rectifying the leak and charging the refrigerant (R-22) complete for Tower/split/window type A/C of any capacity complete all as specified and directed. Note : (i) Job includes dismentling equipment from any site, height and transporting to workshop if necessary and reinstalled in situ and testing (ii) Above Job to be guaranteed for minimum one year
--ditto -- all as per item No.64 but for water cooler of any capacity complete all as specified and directed.
--ditto -- all a s per item No.64 above but suitable for refrigertor/ deep freezer of any capacity complete all as specified and directed.
M & L for repairs to base/body/stand of water cooler of any capacity by cutting out rusted portion, replacing with new M.S sheet of existing gauge including finishing wall surface and painting complete body of water cooler of any capacity complete all as specified and directed. Noe :- Job includes dismantling equipment transporting to workshop and back included' re-installing in situ.
Supply and fix in repairs chasis made out of 2mm thick MS sheet suitable for 1.5 TR/ 2.0 TR capacity window type AC including dismantling accessories and re-installing on new chasis, painting complete body and required parts incld connection with new wiring etc all as directed
Material and labour for servicing of A/C window type or split type A/C, tower AC of capacity 1.5/2/2.5 TR including washing with sodash the cooling coil/condensor coil base body drying with air blower checking complete wiring testing and re-installing in situ and testing the unit.
M & L for dismentling unserviceable compressor from the window type AC, Split type A/C 1.5 TR/ 2.0 TR capacity from any location , supply and fix new hermatically sealed compressor unit , assembling, brazing pressure/vaccum testing initial oil charging, gas charging,reinstalling A/C in situ and connecting to electric supply and testing all as directed and specified. Make : Voltas/Carrier/Kirloskar /bluestar Note : (i) Job including removing A/C from any site/height/location (ii) Transporting A/C unit to repair workshop and back to site (iii) Loading/unloading etc
--ditto -- all as per item 70 above but suitable for refrigerator 165 to 320 ltrs capacity complete all as specified and directed.
--ditto -- all as per item 70 above but suitable for water cooler 40 to 150 ltrs capacity complete all as specified and directed.
--ditto -- all as per item 70 above but suitable for deep freezer of 200 to 500 ltrs capacity complete all as specified and directed.
Supply and fix in repair AC fan motor for window/split type A/C of 1.5/2 TR ,Tower AC 2.5 TRcapacity single phase 230 volt 50 HZ complete with fan blade/blower including any addition/alteration to suit new fitting of motor.
--ditto -- all as per item 74 above but for Water cooler any capacity complete all as specified and directed.
--ditto -- all as per item 74 above but for deep freezer any capacity complete all as specified and directed.
Supply and fix in repair Relay for A/C split/window type,Tower AC complete all as specified and directed.
Supply and fix in repair Relay for WATER COOLER/DEEP FREEZER complete all as specified and directed.
Supply and fix in repair Thermostat for A/C 1.5 TR/2 TR,Tower AC complete all as specified and directed.
-ditto- all as per item No 79 but for water cooler of any capacity complete all as specified and directed.
Supply and fix in repair Air filtter for window type/split type AC, Tower AC as per sample complete all as specified and directed.
Supply and fix in repair Starting capacitor 80-100 mfd 220 volt 50 HZ complete all as specified and directed.
Supply and fix Starting capacitor of capacity 120 - 150 MFD for 2 TR, 2.5 TR capacity complete all as specified and directed.
Supply and fixing in repair of Running capacitors of capacity 45 MFD 220 volt 50Hz complete all as specified and directed by Engr-in-Charge
-ditto- all as per item No 84 but 36 MFD complete all as specified and directed.
-ditto- all as per item No 84 but 6 MFD complete all as specified and directed.
-ditto- all as per item No 84 but 4 MFD complete all as specified and directed.
Supply and fix in repair 4 core 4 sqmm flexible cable PVC insulated sheathed copper 1100 volts grade complete all as specified and directed.
Supply and fix in repair 4 core 2.5 sqmm flexible cable PVC insulated sheathed copper 1100 volts grade complete all as specified and directed.
Supply and fix in repair Earthed Metal clad socket outlet with earthed plug top 20 Amps capacity with sheet metal enclosure and one 20 Amps MCB SP all as specified and directed. Make - Indoasian/ Havells/ Schneider
M & L for power point wiring with PVC insulated sheathed copper wire 4 Sqmm size 1100 volts grade IS-654 in and including PVC casing and capping with all accessories including one run of 4 Sqm earth lead wire all as directed and specified. Make - KEI/ Benlo/ Polycab/ Finolex
Supply and fix in repair copper tube of size 6 mm bore including brazing etc with rubberised insulation and tape suitable for supply pipes for air-conditioners complete all specified by Engineer -in-charge
Supply and fix in repair copper tube of size 10 mm bore including brazing etc with rubberised insulation and tape suitable for supply pipes for air-conditioners complete all specified by Engineer -in-charge.
Supply and fix in repairs 8 mm dia hand shut off valve complete all as specified and directed.
Supply and fixing in repair and testing fan blade of motor for water cooler of 80/100/120/150 Ltrs capacity including removing old fan blade.
Supply and fixing in repair and testing fan blade suitable for window type Air conditioner of 1.5 Ton/2 Ton capacity including removing old fan blade.
Supply and fix in repairs front grill as per sample suitable for window type AC 1.5 TR/2 TR capacity.
Supply and fixing in repair of blower drum suitable for window type Air concitioner of capacity 1.5Ton /2TON.
Supply and fix in repair stainless steel tank of capacity 40 ltrs capacity water cooler of existing size shape
--do-- all as per item 99 above but 80 ltrs capacity complete all as specified and directed.
--do-- all as per item 99 above but 120 ltrs capacity complete all as specified and directed.
Supply and fix in repair waste water tray suitable for single/double tap with waste hose complete all as specified and directed.
Supply and fix in repair PVC float valve wih PVC ball suitable for 15mm dia complete all as specified and directed.
Supply and fix in repairs bibtap push type stainless steel 15mm dia complete all as specified and directed.
Supply and fix in repairs gun metal gate valve with iron wheel head screwed both ends for iron pipe of size 20mm complete all as specified and directed.
Supply and fix in repairs gun metal gate valve with iron wheel head screwed both ends for iron pipe of size 15mm complete all as specified and directed.
Supply and fix in repairs remote sensor kit with Manual control pendent suitable for split type A/C,Tower AC 1.5 TR to 2.5 TR capacity work on 230 volt SP 50 HZ complete all as specified and directed.
Supply and fix base tray suitable A/C 1.5/2 TR made out of 2mm thick of existing size and shape including painting one coat zine chrome red oxide and two coats of synthetic enamelled paint complete all as specified and directed.
Supply and fix in repairs ventury and blower drum suitable for A/C window type 1.5 TR/2 TR as per existing model, size, and shape complete all as specified and directed.
Supply and fix in repairs condensor coils suitable for 1.5 TR to 2.5 TR capacity including dismentling old one brazing, testing, leakage rectification all as directed.
Supply and fix in repairs cooling coil suitable for 1.5 TR to 2.5 TR A/C of existing model including taking out old defective coil, brazing work, brass charging to full pressure complete all as specified and directed.
Supply and fix in repairs thermal over load relay 415 volts 66 - 110 Amps rating MMX R-4 model complete all as specified and directed.
Supply and fix in repairs thermal over load relay 415 volts 32 - 50 Amps rating MMX R-4 model complete all as specified and directed.
M&L in repair for wall mounted powder coated MS bracket suitable for 1.5TR/2TR Split type AC, Towre AC 2.5 TR out door unit
M&L for repair of rubberised insulation and tape for copper tubes of size 6mm/10mm complete all as specified and directed.
Supply and fix PVC drain pipe of size 5/8" bore for supply pipes for air conditioners complete all as specified and directed.
Material and labour for shifting of A/C window type or split type A/C, tower AC of capacity 1.5/2/2.5 TR with mounting bracket including washing cooling coil/condensor coil base body drying with air blower complete all as specified and directed.
Taking down copper/ aluminum point wiring (Light/Fan/Socket or power) complete including fitting and fixtures such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. (Removing materials to store for keeping in safe custody for reuse at site or for credit or and making good disturbed surfaces to walls floors etc).
Taking down main switch/DB/ changeover/AC box of any capacity including fixing accessories
M&L for point wiring complete 1.5 sqmm single core PVC FRLS insulated, unsheathed, 1100V grade multistranded copper conductor drawn through in and including PVC casing and capping surface on walls, roofs floors etc pass through wall/floor including PVC insulated copper earth continuity conductor 1.5 Sqmm cable ( green) connected to common earth dolly including pressed steel terminal boxes 60 mm deep concealed in walls with laminated sheet top cover 3mm thick for housing the switches, sockets regulations etc all specified and directed by Engineer-in-Charge for the following:-(Make of Wire - Anchor/ Polycab/ Finolex/ Havells, Make of Casing/ Caping - Precision/ Sudhakar) For one light, fan, call bell point controlled by one switch.
-Ditto- all as per item No 120 here-in-before but For one 5A 2 pin/3pin socket out let multipurpose on same board with other switches.
-Ditto- all as per item No 120 here-in-before but For one 5A 2 pin/3pin socket out let multipurpose on Independent board.
-Ditto- all as per item No 120 here-in-before but for one light point controlled by two 2- way switch.
All as per item No 120 here-in-before but for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, multistranded 1100 volt grade cable and 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, multistranded 1100 volt grade cable as continuous earth lead.
S & F in repair for switch piano flush type single pole one way 5 Amps, 240 volts, white finish complete all as specified. Make - Anchor/ Leader/ Vinay
S & F in repair for switch socket combination 2 in 1, 3 pin 5 Amps multipurpose flush type , 240 volts, white finish complete all as specified. Make - Anchor/ Leader/ Vinay
S & F in repair for switch flush type single pole two way 5 Amps, 240 volts, white finish complete all as specified. Make - Anchor/ Leader/ Vinay
S & F in repair for switch socket combination 2 in 1, 3 pin, 5A/16 Amps multipurpose flush type , 240 volts, white finish complete all as specified. Make - Anchor/ Leader/ Vinay
S & F in repair for bell push AC 230 Volt, flush type 5 Amps white finish complete all as specified. Make - Anchor/ Leader/ Vinay
S & F in repair electronic socket size, rotary, 5 speed step type regulator, 250 V white finish complete all as specified.
S & F in repair Calling Bell 230 Volt, AC, Single pole complete. Make - Anchor/ Leader/ Havells
S & F in repair ceiling rose, 3 phase/PVC polycarbonate, isolated body complete. Make - Anchor/ Leader/ Vinay
S&F, in repair, double door sheet metal enclosure DB SPN 8 ways, with 200 Amps rated bus bar 240 V complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires all as directed.
-Ditto- all as per item No 133 here-in-before but 4 ways -do-.
S&F double door sheet metal enclosure DB TPN, 4 ways, 415Volts (horizontal type) with 200 Amps rated bus bar properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs for cables/wires old or new complete all as directed. Make - Havells/ Schneider/ Standard/ Legrand
S & F in repair MCB, SP, 240 volt, 5 Amp to 32 amp, 10 KA, capacity having B-curve characteristics connected with suitable lugs. Make - Havells/ Schneider/ Legrand/ Wipro
-Ditto- all as per item No 136 here-in-before but SP 40 Amps complete. Make - Havells/ Schneider/ Legrand/ Wipro
-Ditto- all as per item No 136 here-in-before but SPN 32 Amps complete. Make - Havells/ Schneider/ Legrand/ Wipro
-Ditto-all as per item No 136 here-in-before but SPN 40 - 63 Amps complete. Make - Havells/ Schneider/ Legrand/ Wipro
-Ditto- all as per item No 136 here-in-before but TP 25 - 63 A 415V complete. Make - Havells/ Schneider/ Legrand/ Wipro
-Ditto- all as per item No 136 here-in-before but TPN 40 - 100 Amps complete. Make - Havells/ Schneider/ Legrand/ Wipro
S&F modular type 3/5 pin socket with one single pole MCB 20 Amp 230 Volts complete all as specified including concealing in wall suitable for Geyser, AC and Domestic appliances complete all as specified and directed. Make - Havells/ Legrand/ Schneider
S & F in repair metal clad socket industrial 2pin & earth plug top 20A, 230V complete suitable for AC Box.
S & F in repair metal clad socket industrial 2pin & earth plug socket 20A, 230V complete suitable for AC Box.
Taking down tube light / CFL fitting any wattage from roof /wall and repairing & refixing the same at directed place incl replacement of three core 0.5 Sqmm copper conductor & flexible wire/cable complete.
M & L for opening switch mounting plate, rectifying the defects in fittings and fixtures by tightening loose connectiion or taking down of unserviceable / burnt Piano switches, fan regulators, 5/15 Amps Sockets, 5/15 Amp Switch Socket combination or any other electric accessories of switch socked complete. Note - (i) Replacement of defective parts/items will be measured and paid as supply respective items here in below.
M & L for opening MCB DB/MCCB DB front door & replacing of burnt wires & testing complete after carrying out repairs. Note - (i) MCCB & MCB required to be replaced shall be paid under respective item of this schedule as supply. (ii) Minor spares such as connectors, wires, lugs are deemed to be inclusive of the quoted rate.
M & L for servicing of LT panel and rewiring of old burnt out copper wiring, replacing of damaged cable glands, burnt cable lugs, bus bar link, connectors, damaged insulators, burnt copper cables, door hinges, panel door locks & scrapping of old paints & appling two coats of synthetic enamal paint over a coat of red oxide zine ehrome primer paint all as directed by Engr-in-charge.
S&F in repairs ULTRON LED polycarbonate T8 tube 20/22 Watt with in built driver with metal heat sink, double sided connection, 230 volts including fixing arrangements and taking down old unserviceable tube rod complete. Make - Bajaj/ Jaquar/ Crompton/ Wipro
S&F in repairs Surface, hanging and wall mounted batten (Double side connection) fitting of 20/22 watts, 230 volts including fixing mounting blocks 2 Nos, 15 mm MS conduit, 1.5 sqmm 3 core pvc insulated copper conductor cable including fixing arrangements complete all as specified and directed. Make :- BAJAJ/ PHILLIPS/ JAQUAR/ WIPRO
Supply and fixing in repair ceiling fans complete with blades, down rods accessories etc operating with electronic regulator on 230 V, 1200 mm sweep. Min air delivery 210 CFM full load wattage 26 to 32 watts, High Speed conforming to IS 374 :2019, colour white BEE 5 star rated with brushless direct current motor (BLDC) without remote complete including taking down old unserviceable fan to MES store all as directed by Engr-in-Charge. Make : BAJAJ (Model : ENERGOS 28) / ORIENT (I FALCON) Note : Unserviceable ceiling fans shall be deposit to MES store.
Supply and fix in repair electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW, 230V / 50Hz, Temperature Range 25 to 70 degree celcius & working pressure 0.8 Bar capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc complete all as specified and directed. Make : AO SMITH / RACOLD / BAJAJ / JAQUAR Note : Contractor will give the warranty - 5 Years of Tank, 2 Years of Heating Element and 2 Years on Other Parts on Geyser supplied.
Supply and fixing in replacement of LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including provision with three core flexible copper conductor cable of suitable size and PVC square blocks complete all as specified and directed. Make :- BAJAJ/ PHILLIPS/ JAQUAR/ WIPRO
Supply and fix in repairs decorative recessed type LED light fitting 36 watt (size 2'x2') and including driver unit, including provision of 3 core copper flexible cable from ceiling rose to connector, including making addition/altn to existing false ceiling and providing of false ceiling sheets, aluminium frames including fixing arrangements and taking down old rusted bracket fittings complete etc. Make :- Crompton/ Bajaj/ Phillips/ Wipro/ Jaquar
Supply and fix in replacement flood light fittings in street light poles/Buildings the fitting shall be of LED type 150 Watts complete with and including drivers, pressure die cast aluminium housing, prewired complete. Make :- Crompton/ Bajaj/ Phillips/ Wipro/ Jaquar
M&L for earthing complete with M.S. galvanized earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below normal GL) with top edge of the earth plate not less than 1.5M below normal GL, connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts & washers of GI or steel incl excavation, PCC (1:3:6) type C-1 chamber with RCC cover (1:2:4) type B0, 40 mm thick reinforced with 6 mm dia bar, 3 Nos. both way, 15 mm dia light grade GI protection pipe, funnel with wire mesh,watering pipe of size 20 mm dia med. grade, lugs, main Earthing lead upto 7.5 mtr incl. Charcoal dust, salt etc. all as shown in electrical plate No. 3 of SSR Pt-I, 2009 specification.
M&L for cutting / boring of PCC/hard standing at a depth not more than 15 cm deep and 15 cm in wide for passing earthing conductor and making good the disturbed surfaces with PCC (1:2:4) type B-0 or cement mortar (1:3) complete all as specified.
Supply and fixing of HDPE pipe of class PN 10 medium grade of size 40/50 mm bore for laying in trenches/floors or walls including all fittings for fixing complete as required and directed by Engineer-in-Charge.
M&L for earth continuity conductor or main earthing lead 4 mm dia GI or steel wire fixed to wall on batten or recessed or buried in ground or drawn in existing/ new conduit all as required at site.
M&L for testing of old earthing using calibrated earth tester & submitting result to engr -in -charge all as directed. Note : (i) Watering of earthing with 2 Buckets (30Ltrs) water mixed with salt (total 20Kg) shall be carried out one day before the testing & the cost of the same shall deemed included in unit rate quoted.
M&L for painting on wall with synthetic enameled paint of black colour as background of 200 x 150 mm size and writing for earth test result with date & year all as specified and directed at site by Engineer-in-Charge. Make - Asian/ Berger/ Apcolite
M & L for repairing of broken earthing pits chamber (size 0.30 to 0.45 Sqm) with PCC (1:3:6) type C-1 with RCC cover (1:2:4) type B0, 40 mm thick reinforced with 6 mm dia bar, 3 Nos. both way, funnel with wire mesh for watering pipe all as directed by Engr-in-charge.
Material and Labour for checking of Bldg Panels, DB's, Junction boxes including servicing/cleaning by blower, bunch and tightening of loose nut, bolts, washer, cable lugs, thimbles of any size, including wire of copper, all as per existing size and connector etc complete all as specified and directed. Note : Rate of Misc material for above maintenance such as cable lugs, wire, thimbles, nuts, bolts required shall be unclusive of quoted rate.
S&F,in repair PVC laminated ISI marked top cover 3 mm including cutting/drilling holes for mounting housing of switches, sockets, etc as per site requirement of suitable size complete all as specified and directed.
Daily door to door repair/replacement of maintenance for Md Accn bldg covered under GE (NW) Mankhurd area (a) Thane, (b) Mahul (c) Sewri, (d) Mankhurd by team of contractor's comprises of (a) One Electrician and 01 x Helper will be carried out daily under restective area :- Note 1 :- (a) Contractor will be assigned to visit one area daily alongwith man and material as per as per direction of Engineer-In-Charge and he will perform all petty repair work as demanded by user of bldg. (b) Contractor will make his own arrangement for to and fro of his team and his rates shall be inclusive of this aspect. (c) The material component require for above complaint will be measured and paid as “Supply only” under respective item of this schedule. Certain material may be issued from the department free of cost for fixing only as per direction of Engineer-in-Charge. (d) If contractor fails to attend the area, a sum of Rs 4000/- per days will be recovered on account of non attedance of petty repair work from any legitimate payment due to contractor. A sum of Rs 500 per false complaint/wrong signature will also be recovered from the contractor. (e) Contractor will also attend the petty repair work on all days of week i.e Working day as per direction of Engineer-in-Charge. (f) Contractor will obtain log sheet of repair work perform by him duly signed by occupant user and authorised user rep both. (g) Rep of contractor, Rep of GE Office and Rep of User alongwith labour team (Carpenter, Plumber, Electrician and helper) will visit door to door and get the user complaint and rectified on the same day. (h) A detailed log of complaints with completion/ non-completion remarks from users/MES will be maintained by the contractor and same will be updated on daily basis in consulatation with Engr-in-Charge or JE detailed by him. (j) The contractor will make suitable arrangment for emergent complaints and will notify auth rep/Engr-in-Charge about extraordinary circumstances for probable non-completion or delay in rectification of complaints beyond state time limit set for disposal of complaint. In case of any dispute the decision of accepting officer will be final and binding in this regard. (k) The quoted rate deemed to be inclusive of transportation and other expenses required for the resource deployment at the complaint site around scattered Naval Depot and area like Mahul, Thane etc. (l) The contractor will maintain suitable inventories and range of spares required to meet the complaints as same will be reviewed peridically by Engr-in-charge to streamline complaints disposal system. (m) Petty repairs to plumbing/internal water supply works such as repair to leaking bib taps, pillar taps, mixers stop cocks by tightening and providing spindle,washer repairs to float valves, low leveled cistern to the satisfaction of user as assigned by the Engineer In Charge. (n) Dress like Dangri and other for labours to be provided contractor as per direction of Engineer-in-Charge. (o) Contractor will arrange all the T&P for his labours with aluminium ladder as required. Note 2. The whole team will visit only one area daily (one of Mankhurd, Nofra, NSB,NAD Colony, SPDC Colony, Mahul, Sewri or Thane area) and perform door to door maintenance work building wise. Note 3. Contractor should includes cost of fixing joinery, plumbing and electricals works like screws, teflon tapes, insulation tapes, washers etc
Supply only Piano switch 6 Amp, 230 V Comptete all as specified and directed. Make - Legrand/ Havells/ Anchor
Supply only Bell Push Piano type, 230 V Comptete all as specified and directed. Make - Legrand/ Havells/ Anchor
Supply Only switch socket Combination box type 3 Pin, 5 Amp Comptete all as specified and directed. Make - Legrand/ Havells/ Anchor
Supply Only switch socket Combination box type 3/5 Pin, 15 Amp Comptete all as specified and directed. Make - Legrand/ Havells/ Anchor
Supply Only switch socket Combination without box 3 Pin, 5 Amp Comptete all as specified and directed. Make - Legrand/ Havells/ Anchor
Supply Only switch socket Combination without box 3/5 Pin, 15 Amp Comptete all as specified and directed. Make - Legrand/ Havells/ Anchor
Supply Only Fan regulator electronic type 5 step, 230 V Comptete all as specified and directed. Make - Anchor/ Vinay/ Leader
Supply only Modular type switch 6/ 10 Amp one way, 230 V Comptete all as specified and directed. Make - Legrand/ Havells/ Anchor
Supply only Modular type switch 16 Amp one way, 230 V Comptete all as specified and directed. Make - Legrand/ Havells/ Anchor
Supply only Modular type socket 6/16 Amp one way, 230 V Comptete all as specified and directed. Make - Legrand/ Havells/ Anchor
Supply only Modular Fan regulator electronic type 5 step, 230 V Comptete all as specified and directed. Make - Legrand/ Havells/ Anchor
Supply only Fan capacitor 2.5 Mfd Comptete all as specified and directed. Make - Tibcon/ Capcon/ Havells/ Epcos
supply only Ceiling Rose surface bacelite 3 terminal, 230 V Comptete all as specified and directed. Make - Anchor/ Vinay/ Leader
Supply only Ding dong bell AC 230 V Comptete all as specified and directed.Make - Anchor/ Havells/ Leader
Supply only Switch flame proof rotary type with termination box in LM6, 16A, single pole 240 V Comptete all as specified and directed.
Supply only LED light fitting suitable size mirror type with high out put diffuser 5 - 8 watt 230 V AC decorative type including provision with three core flexible copper conductor cable of suitable size complete. Make :- BAJAJ/ PHILLIPS/ JAQUAR/ WIPRO
Supply only LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 230 V AC decorative type with driver holder and LED lamp including provision with three core flexible copper conductor cable of suitable size and PVC square blocks complete. Make :- BAJAJ/ PHILLIPS/ JAQUAR/ WIPRO
Supply only Surface, hanging and wall mounted batten (Double side connection) fitting of 20/22 watts, 230 volts including fixing mounting blocks 2 Nos, 15 mm MS conduit, 1.5 sqmm 3 core pvc insulated copper conductor cable including fixing arrangements complete all as specified and directed. Make :- BAJAJ/ PHILLIPS/ JAQUAR/ WIPRO
Supply only ULTRON LED polycarbonate T8 tube 20/22 Watt with in built driver with metal heat sink, double sided connection, 230 volts including fixing arrangements and taking down old unserviceable tube rod complete. Make :- BAJAJ/ PHILLIPS/ JAQUAR/ WIPRO
Supply only LED Bulb of 15/20 watt operating on 230 V, 50 Hz, AC supply suitable for wellglass fitting complete all as specified and directed. Make - Wipro/ Bajaj
Supply only LED Bulb of 30/35 watt operating on 230 V, 50 Hz, AC supply suitable for wellglass fitting complete all as specified and directed. Make - Wipro/ Baja
Supply only LED Bulb of 160 watt operating on 230 V, 50 Hz, AC supply suitable for wellglass fitting complete all as specified and directed. Make - Wipro/ Baja
Supply only LED Bulb Holder suitable for fixing bulb of any wattage Comptete all as specified and directed. Make - Anchor/ Vinay/ Leader
Supply only PVC Tape of suitable size Comptete all as specified and directed.
Supply only MCB SP 240 V 5 Amp to 32 Amp, 10 KA Comptete all as specified and directed. Make - Wipro/ Legrand/ Havells
Supply only MCB SPN 240 V 10 Amp to 32 Amp, 10 KA Comptete all as specified and directed. Make - Wipro/ Legrand/ Havells
Supply only MCB SPN DB 8 way Double door Comptete all as specified and directed. Make - Wipro/ Legrand/ Havells
Supply only FRP Looping Box of size 150 x 200 x 100 mm with connected, 6 Amp MCB and GI clamp Comptete all as specified and directed.
Supply only Blank MCB Plate of SPN/ TPN DB Comptete all as specified and directed.
Supply only aluminium cable lugs of size 10 Sqmm Comptete all as specified and directed.
Supply only aluminium cable lugs of size 16 Sqmm Comptete all as specified and directed.
Supply only aluminium cable lugs of size 25 Sqmm Comptete all as specified and directed.
Supply only single compression Brass cable gland with nickle plated size of 10 sqmm Comptete all as specified and directed.
Supply only single compression Brass cable gland with nickle plated size of 16 sqmm Comptete all as specified and directed.
Supply only single compression Brass cable gland with nickle plated size of 25 sqmm Comptete all as specified and directed.
Supply only cotton cloth for cleaning hands Comptete all as specified and directed.
Supply only Plug top 3 pin 15/16 Amps capacity Comptete all as specified and directed. Make - Anchor/ Havells
Supply only Plug top 3 pin 5 Amps capacity Comptete all as specified and directed. Make - Anchor/ Havells
Supply only LED Driver 150 watts to 350 Watts Suitable for highbay/flood/street light fitting Comptete all as specified and directed.
Supply only LED Driver 30 watts to 60 Watts Suitable for highbay/flood/street light fitting Comptete all as specified and directed. Note : A sum of Rs 80,611.00 towards sch of credit shall be deducated to arrive the contract sum.
sapana enterprises
R J ENTERPRISES
Shree Ayyappa Engineering
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .