| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.6 LAccepted-AOC | L1 | Accepted-AOC Bidder quoted L1 rates | |
| 2 | L2₹33.6 L+₹73,642 (2.24%)Rejected-AOC | L2 | Rejected-AOC Bidder not quoted L1 rates | |
| 3 | L3₹34.9 L+₹2.1 L (6.27%)Rejected-AOC FLAT NO 601 TOWER NO 30 SECTOR NO 21 AMANORA PARK TOWN HADAPSAR PUNE 411028 | PUNE | MAHARASHTRA | 411028 | L3 | Rejected-AOC Bidder not quoted L1 rates | |
| 4 | L4₹37.0 L+₹4.2 L (12.8%)Rejected-AOC OFFICE NO 101 MALAN PLAZA NEXT TO ESSAR PETROL PUMP NEAR GODAMBLE CORNER RAHATNI PIMPRI DP ROAD RAHATANI PUNE 411 017 | PUNE | PUNE | MAHARASHTRA | 411017 | L4 | Rejected-AOC Bidder not quoted L1 rates | |
| 5 | L5₹38.9 L+₹6.0 L (18.4%)Rejected-AOC 02 NERLE NERLE YEWALEWADI ROAD NERLE SANGLI MAHARASHTRA 415406 | SANGLI | MAHARASHTRA | 415406 | L5 | Rejected-AOC Bidder not quoted L1 rates |
Tender Value
Refer Docs
EMD Value
₹88,000
Closing Date
29 Apr 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE SOUTH PUNE
NO 1 GENERAL BHAGAT MARG PUNE 411040
8249 MAINT/REP/REPL OF ELECT SYST/REP TO FTGS, DBS ELECTRICAL PROTECTIVE SYST AND OTHER ELECT WORK IN AREA OF AICTS, PCDAO, NADFM, WR STN AND FAMILY QTRS OF SPS LINE, NGBM AND NP LINES, OFFICERS ACCN OF AICTS AND OTHER CONNECTED AREA UNDER GE S PUNE
2021_MES_433869_1
8249 GE SOUTH PUNE
Open Tender
Civil Works
Item Rate
273 days
GE SOUTH PUNE
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE SOUTH PUNE
₹88,000
Yes
19 Jun 2021
31 Mar 2021
1 May 2021
31 Mar 2021
29 Apr 2021
16 Apr 2021
60 days
Amount
Taking down carefully exising unserviceable aluminium point wiring (light, fan, socket or power), complete (fitting such as switches,ceiling rose, pendent, regulators etc) removing material to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately and making good disturbed surfaces of wall, floor etc. complete all as specified and as directed.
M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 volts grade, ISI-694 marked drawn through in and including heavy duty, PVC casing caping including all accessories etc, heavy duty ISI marked, with GI sunken /surface boxes with earth dolly duly as per site requirment , covered with modular white cover plate with frame suitable for modular switches of Make- Legrand ( Mirius ) or equivalent Honey well / phillips , or PVC surface mounted modular box, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following :-
One light point controlled by one, one way switch 5 Amps
One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator
One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad.
One bell point controlled by one, bell switch 5 Amps
One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
Description all as per item No 2 here in before but using 2.5 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly.
M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 volts grade, ISI-694 marked drawn through in and including heavy duty, PVC casing caping including all accessories etc, heavy duty ISI marked, with mild steel sunken boxes with earth dolly duly, covered with hylem sheet cover 3 mm thick, ISI marked suitable for fixing of switches, fan regulators and sockets including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following :-
One light point controlled by one, one way switch 5 Amps
One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator
One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad.
One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi stranded, FRLS- FLEXIBLE WIRING CABLE. CONFORMING TO IS: 694-1990 PVC insulated, unsheathed copper conductor cable with tripple layers protection Make:- Fenolex/policab/ Havell's drawn through in and including heavy duty , PVC concealed conduit of white/ ivory colour including all accessories after cutting chasing in wall of any type /ceiling etc, heavy duty ISI marked, with GI sunken boxes with earth dolly duly, covered with modular white cover plate with frame suitable for modular switches of Make- Legrand ( Mirius ) or equivalent Honey well / phillips including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly all as specified and directed for the following :-
One light point controlled by one, one way switch 5 Amps
One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator
One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad.
One bell point controlled by one, bell switch 5 Amps
One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
All as per item No. 5 above but using 2.5 sqmm copper conductor for with 1.5 sqmm earth wire one 6 pin 15 amps socket outlet on independent board all as specified and directed.
M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi stranded, FRLS- FLEXIBLE WIRING CABLE. CONFORMING TO IS: 694-1990 PVC insulated, unsheathed copper conductor cable with tripple layers protection Make:- Fenolex/policab/ Havell's drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after cutting chasing in wall of any type /ceiling etc,, with mild steel sunken boxes with earth dolly duly, covered with hylem sheet cover 3 mm thick, suitable for fixing of switches, fan regulators and sockets including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following :-
One light point controlled by one, one way switch 5 Amps
One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator
One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad.
One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
All as per item No. 7 above but using 2.5 sqmm copper conductor for with 1.5 sqmm earth wire one 6 pin 15 amps socket outlet on independent board all as specified and directed.
All as per item No. 7 above but using 2.5 sqmm copper conductor for with 1.5 sqmm earth wire one 6 pin 15 amps socket outlet on independent board all as specified and directed.
S & F for Modular Switch piano flush type, single pole, one way, and 5/6 Amp single module complete all as specified.
S & F for Modular Switch piano flush type, single pole, one way, and 15/16 Amp single module complete all as specified.
S & F for Modular Socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, 5/6 Amp, 2 module piano flush type complete all as specified.
S & F for modular step type fan regulator 100 watt 2 module suitable for 230 volt 50 Hz AC supply complete all as specified and as directed.
S & F for for Bell push modular 6 Amps single module complete all as specified.
S & F in repair Modular Switch Socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, 2 module piano flush type complete all as specified. (Make - Legrand (Myrius) of other make existing approved by GE)
S & F in repair modular Black plate with frame 4 MOUDLES complete all as specified. (Make - Legrand (Myrius) of other make existing approved by GE)
S & F in repair modular PLATE (Hight density Toughened glass ) with 6 MOUDLES complete all as specified. (Make - Anchor (Roma -Vetro) of other make existing approved by GE)
Supply and fix for Bell Electric Ding dong type suitable for operation on 230 volt 50 HZ A C supply complete all as specified and as directed.
S & F lamp holder insulated body with back plate PVC/Polycarbonate type with cord grip cap, angular type fixed on wall incl 9 watt LED lamp complete all as specified.and directed (Make :- Anchor/Havells/VINAY) (Make of LED Lamp Bajaj/Wipro/Havells)
S & F for Ceiling rose, surface Bakelite suitable ISI marked for batten fitting complete all as specified.
S&F in replacement of switch piano flush type, 15 Amps single pole one way fixed and connect as per existring complete all as specified and directed.
S&F in repair of switch piano flush type, 5/6 Amps single pole one way fixed and connecting to existing board complete all as specified and directed
S&F in replacement of socket outlet flush type 2 in 1, 3 pin , 6 and 15 Amps fixed and connect in existing bdcomplete all as specified and directed.
S&F in replacement of socket outlet 5 pin and 5/6 amps flush type incl fixed and connect in existing bd complete all as specified and directed. (Make:-SSK/Cona/Havells.)
Supply and fixing ceiling fan regulator, electronic, socket type, rotary 0 to 04 steps, hum free, AC, 230 volts, 100 watts, duly ISI marked fixed and connect in existing board complete all as specified & directed. (Make: -Havells / Anchor / indio Asian)
S & F in replacement of switch piano flush type push button for call bell 5 Amps complete all as specified and as directed.
S&F in replacement IP-43, protection metal door Vertical TPN -DB rated busbar, pan assembly etc. with interconnection links, blanking plates, cable ties, identification labels TPN 4 way, 12 modules with provision to mount 100 Amps MCCB 4 pole as incomer and SP/TP MCB as out going and concealed in wall including all cutting holes in or through walls, making good to walls, ceiling etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing Make (Make- L&T (DBVTL004DD ) or Equivalent in Legrand / HPL (O safe )
S&F in replacement MCCB 4 pole 100 Amp, Icu = 18 KA, 415 volts, 50 Hz, type with thermal magnetic release duly connected with copper spreader links 04 Nos and proper size of lugs, nuts bolts and washers for proper connections all as specified and directed. (Make :- L&T (DBVTL004DD ) or Equivalent in Legrand / HPL (O safe )
S&F in replacement,IP-43 ,MCB DB 12 way ,double door, with 100 amp rated busbar 240 V, SPN rand concealed in wall including all cutting holes in or through walls, making good to walls, ceiling etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing Make (Make- L&T (DBSPN012DD) equivalent in Legrand / HPL (O safe )
S&F in replacement,IP-43 ,MCB DB 8 way ,double door, with 100 amp rated busbar 240 V, SPN rand concealed in wall including all cutting holes in or through walls, making good to walls, ceiling etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing Make - (Make- L&T (DBSPN008 DD) equivalent in Legrand / HPL (O safe )
S&F in replacement,IP-43 ,MCB DB 4 way ,double door, with 100 amp rated busbar 240 V, SPN rand concealed in wall including all cutting holes in or through walls, making good to walls, ceiling etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing Make complete all as specified and as directed. (Make- L&T (DBSPN004 DD) equivalent in Legrand / HPL (O safe )
S&F in replacement MCB SP 6-32 Amps,10KA,'C' series complete all as specified and as directed. (Make- L&T/ Legrand / HPL (O safe )
S&F in replacement MCB DP 20-40 Amps,10KA, 240V,'C' series complete all as specified and as directed. (Make- L&T/ Legrand / HPL (O safe )
S&F in replacement MCB TP 32/40 Amps ,10KA,415 V,'C' series complete all as specified and as directed. Make- L&T/ Legrand / HPL (O safe )
S&F in replacement MCB TPN 40 /63 Amps ,10KA,415 V,'C' series complete all as specified and as directed. (Make- L&T/ Legrand / HPL (O safe )
Supply & fix in repair recess mounting LED down light fitting 18/ 20 Watt natural white complete as per existing size repairs/making good the pop/gypsum ceiling with good finish as existing with suitable fixing arrangement connection complete all as specified and directed. (Make-Havells/ Baja /HPL/WIPRO)
S&F LED pannel Recess mounted -2'x2' - 36 watts light fitting with build in PIR OCCUPANCY SENSOR OFFERING FLEXIBLITY OF AUTO SWITCHING OFF WHEN THE SPACE NOT OCCUPIED complete including cutting hole of required size in POP/false ceiling making good disturbed including taking down any type ceiling fitting Make- Phillips RC383B LED 36 S-6500 PSU OD WH PIPR or equivalent of Havells / HPL / WIPRO/ Bajaj
S&F LED pannel Recess mounted -2'x2' - 36 watts light fitting with heat exchanger unit complete including cutting hole of required size in POP/false ceiling making good disturbed including taking down any type ceiling fitting Make- WIPRO ( CRCO10R038HP57GL1 ) or equivalent of HPL/ /Havells./PHILIPS/Bajaj
Supply and fix LED tube light fitting complete with all fitting and fixing accessories, 1X20Watt pre-wired with high efficiency electronic driver, glare free, smooth light distribution conforming to CAT Part No. Garnet 20 W LED (D532065) of Wipro or of equivelent in Havells / HPL / Bajaj complete in cluding taking down any type fitting all as specified and as directed.
Supply & fix Led battern Color changing fitting 20 Watts complete all as specified and directed including taking down existing FTL all as directed. (Make :- Havells/Bajaj/ HPL)
M&L for wall mounting fency light fitting with polycarbonate cover complete with all accessories (connector block, lamp holders) with 9 Watts LED lamp incl taking down any type old fitting all as specified and directed (Make : Havells ( city -4 ) or equivalant make of Bajaj/ Havells & Make of LED Lamp Bajaj/C&S/Havells/ HPL)
Supply & fix in repair recess mounting LED down light fitting 12 Watt natural white complete as per existing size repairs/making good the pop/gypsum ceiling with good finish as existing with suitable fixing arrangement connection complete all as specified and directed. (Make-Havells /HPL/WIPRO)
Supply & fix Led tube fitting 10 WATTS complete all as specified and directed including taking down existing holder all as directed. (Make :- Havells/Wipro/ HPL)
Supply and replace suitable driver for LED down light fitting 18 /20 Watts of the existing make good in a suitable way disturbed area as existed all as specified and directed
Supply & fix LED tube light fitting 20 Watts with alumanium extrusion housing in cluding taking down any type fitting
Supply & fix LED tube light fitting surface / pendent mounting decorative box type CRCA batten with 20 Watt 4 fit long, T-8 diffuser type 20 watt rectrofit tube complete all as specified and as directed.
Supply and replace suitable driver for LED pannel Recess mounted -2'x2' - 36 watts of the existing make in a suitable way and including making good the disturbed area as existed all as specified and directed
Supply & fix Led tube with sensor 14 Watts including suitable base fitting box type complete all as specified and directed including taking down existing FTL all as directed. (Make : Phillips / Havells/Wipro/ HPL)
Supply and fix in replace suitable driver for LED tube fitting 18 /20 Watts of the existing make in a suitable way all as specified and directed
Taking down carefully all type of sub main wiring any core including batten / conduit and making good to disturbed surface as matching to existing complete all as specified and directed.
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size with 06 Sqmm nominal cross sectional area, 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLS- FLEXIBLE WIRING CABLE. CONFORMING TO IS: 694-1990 with and including continuous earth wire of size 6 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable drawing into and including rigid non metallic PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked of suitable size concealed in wall etc and connected to common earth dolly including all cutting / chases etc in any type of wall wall, making good to walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing complete all as specified & directed. (Note:-One meter of conduit along with 2x6 sq mm wire and one 6 sq mm earth shall be measured as one unit length)
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size with 04 Sqmm nominal cross sectional area, 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLS- FLEXIBLE WIRING CABLE. CONFORMING TO IS: 694-1990 with and including continuous earth wire of size 4 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable drawing into and including rigid non metallic PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked of suitable size concealed in wall etc and connected to common earth dolly including all cutting / chases etc in any type of wall wall, making good to walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing complete all as specified & directed. (Note:-One meter of conduit along with 2x4 sq mm wire and one 4 sq mm earth shall be measured as one unit length)
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size with 04 Sqmm nominal cross sectional area,1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLS- FLEXIBLE WIRING CABLE. CONFORMING TO IS: 694-1990 with and including continuous earth wire of size 2.5 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable and including ISI MARKED PVC casing caping including fitting in wall etc and connected to common earth dolly making good to walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing complete all as specified & directed. (Note :- One meter of PVC casing caping along with 2x4 sq mm wire and one 2.5 sq mm earth shall be measured as one unit length)
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size with 06 Sqmm nominal cross sectional area, 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLS- FLEXIBLE WIRING CABLE. CONFORMING TO IS: 694-1990 with and including continuous earth wire of size 4 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable Make:- Finolex/policab/ Havell's and including ISI MARKED PVC casing caping including fitting in wall etc and connected to common earth dolly making good to walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing complete all as specified & directed. (Note:-One meter of PVC casing caping along with 2x6 sq mm wire and one 4 sq mm earth shall be measured as one unit length.)
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size with 10 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLS- FLEXIBLE WIRING CABLE. CONFORMING TO IS: 694-1990 with and including continuous earth wire of size 10 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable and including ISI MARKED PVC casing caping including fitting in wall etc and connected to common earth dolly making good to walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing complete all as specified & directed. (Note:-One meter of PVC casing caping along with 2x10 sq mm wire and one 10 sq mm earth shall be measured as one unit length.)
M & L for Sub main wiring with approved colour coding as per IS with four single core PVC insulated FRLS cable with stranded copper conductor of size with 06 Sqmm nominal cross sectional area,multi core core, 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLS- FLEXIBLE WIRING CABLE. CONFORMING TO IS: 694-1990 with and including continuous earth wire of size 4 Sqmm nominal cross sectional area, with two single core, PVC insulated, copper conductor cable drawing into and including rigid non metallic PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked of suitable size concealed in wall etc and connected to common earth dolly including all cutting / chases etc in any type of wall, making good to walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing complete all as specified & directed. (Note :- One meter of conduit along with 4x6 sq mm wire and 2x 4 sq mm earth shall be measured as one unit length.)
M & L for Sub main wiring with approved colour coding as per IS with four single core PVC insulated FRLS cable with stranded copper conductor of size with 06 Sqmm nominal cross sectional area,multi core core, 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLS- FLEXIBLE WIRING CABLE. CONFORMING TO IS: 694-1990 with and including continuous earth wire of size 6 Sqmm nominal cross sectional area, with two single core, PVC insulated, copper conductor cable drawing into and including ISI MARKED PVC casing caping including fitting fixed onwall /ceiling etc of suitable size connected to common earth dolly including all cutting / chases etc in wall, making good to walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing complete all as specified & directed. (Note :- One meter of conduit along with 4x6 sq mm wire and 2x 6 sq mm earth shall be measured as one unit length.)
Supply & fix in repair existing fan Condenser 2.5 mfd 230 Volts complete all as specified and as directed. (Make :-Havells / Epcos/Tibcon /Siemens)
Supply & fix in repair existing fan Condenser 4 mfd 230 Volts complete all as specified and as directed. (Make :-Havells / Epcos/Tibcon /Siemens)
S&F in replacement of burnt out and unserviceable fan motor assembly complete including double bearing, copper windng with metal plate top & bottom side suitable for 1200mm sweep in any existing make complete all as specified and as directed.
Labour only for attending emergent complaints i.e no light , earth leakage, short cicuit, neutral break I mains /sub mains/internal circuits of existing system of main building / block ,making continious electric supply including carrying out minour repairs etc as required to make the system in order / functional including replacing fuse wire , copper cable, copper thimbles ,glands, earthing wire complete all as specified and directed. (Note :- 1. Rate of Fuse wire, copper cable, copper thimbles, glands,earthing wire are deemed to be considered in this item 2. Minimum One electrician to be present daily during thecontract period, if found absent Rs-1600 will be deducted daily)
Supply and replace anchor bolt & nut 8mm dia of the geyser in a suitable way and making good the distrubed area all as specified and directed
Supply and replace pvc box with 06 Amps switch and socket 06 Amps dully fixed in wall all as specified and directed
Supply and replace pvc box with 16 Amps switch and socket 16 Amps dully fixed in wall all as specified and directed
Supply only Self adhesive PVC electrical Insulation tape 7mtr long with superior quality complete all as specified and as directed.
Supply and replace hylum sheet as existed in the Switch boad making provision for fixing switches and socket all as specified and directed
Taking down fans, removing to workshop for servicing, cleaning, lubricating, replacement of split pin, rubber bush and other spare required if any including fixing PVC cable with stranded copper conductor of size 0.75 Sqmm and refixing the fans at the same locations. (Note:- Spares like , bearing, terminal connector, gun metal bush, PVC cable shall be measured and paid seperately as supply only)
Ceiling fans of any size
Exhaust fan of any size
Wall mounting fan of any size
Supply only the following spare parts :-
Bearing 6200 to 6203 ZZ Make - SKF/NBL
Conductor Terminal 3 way Bakelite
Supply only brass gun metal bushing suitable of size 1200/1400mm sweep ceiling fan complete all as specified and as directed.
Supply and Fix in replacement canopy for ceiling fans (Set of two) complete all as specified and as directed.
Supply and Fix in replacement MS clamp with rubber reel, nuts, bolts, split pin etc suitable for 1200/1400 mm sweep ceiling fan complete all as specified and as directed.
Supply and replace fan blade (set of 3 )suitable foe 1200 mm of existing make complete all as specified and as directed.
M&L for replacement of burnt winding of fans, rewinding complete with super enamelled copper wire of same guage and weight, replacement of insulation paper, varnishing, heating up and testing complete including taking down and refixing the fan at positions to the satisfaction of Engr-in-charge
Ceiling fan 1200/1400mm sweep working on 230 volts AC supply
Exhaust fan upto 300/450 mm sweep working on 230 volts AC supply
Wall mounting fan of any 230/450 mm size,working on 230 volts AC supply
S&F in replacement downrod for ceiling fan made out of GI pipe medium grade 15mm dia with fan clamps incl drilling cutting threding etc all as directed for ceiling fan 1200/1400 sweep of following sizes:-
2 ft long
4 ft long
6 ft long
Taking down geysers carrying to workshop for repairing, servicing, cleaning etc, replacement of thermostat, heating element, indicator lamp and thermal cut out incl fixing of PVC cable, sheathed, three core with stranded copper conductor of size 2.5 sqmm and refixing the geysers at location for :- (Note:- Heating element, thermostat indicator lamp & thermal cutout etc shall be measured and paid separately as supply only)
25 liters capacity
50 liters capacity
Supply only heating element 2 KW, 230 volt round/ triangular in shape ISI marked complete all as specified and as directed.
Supply only heating element 1.5 KW, 230 volt round/ triangular in shape ISI marked complete all as specified and as directed.
Supply only heating element 1 KW, 230 volt round/ triangular in shape ISI marked complete all as specified and as directed.
Supply only Indicating lamp (red/green/yellow) complete suitable for 25/50/100 liters capacity geyser complete all as specified and as directed.
Supply only thermostat ISI marked complete suitable for 25/50 liters capacity geyser complete all as specified and as directed.
M&L for spray painting of old surface of ceiling fan/Ex fan/pedestal fan of any description by applying one coat of synthetic enamel paint complete including taking down and refixing and preparation of surfaces all as specified and directed .
Supply and replace single core cable PVC insulated and unsheathed multistranded copper conductor of size 1.5 Sqmm from point wiring including removal old existing unserviceable one complete all as specified and directed.
Supply and replace single core cable PVC insulated and unsheathed multistranded copper conductor of size 2.5 Sqmm from point wiring including removal old existing unserviceable one complete all as specified and directed.
Supply and replace single core cable PVC insulated and unsheathed multistranded copper conductor of size 4 Sqmm from point wiring including removal old existing unserviceable one complete all as specified and directed.
Supply and replace single core cable PVC insulated and unsheathed multistranded copper conductor of size 6 Sqmm from sub main wiring including removal old existing unserviceable one complete all as specified and directed.
Supply and Fix in replacement CFL 3pin 36 watts complete all as specified and as directed.
Supply and Fix in replacement CFL choke 36 watts complete all as specified and as directed.
Supply and fixing in repairs PVC fresh air fan 300mm with louvers complete all as specified and as directed. (Make:Bajaj /cromptan /Havells)
Supply and fixing in repairs PVC fresh air fan 250mm with louvers complete all as specified and as directed. (Make:Bajaj/cromptan/ Havells)
S&F in repairs PVC flexible three core copper 23/0.0076 size complete all as specified and directed.
Supply & fix in replacement 15A plug top and connection complete all as specified and as directed [Make :- Anchor / Havells / legrand or of equivalent make]
Supply & fix PVC connections pipe with brass hexagonal adapters both side. Suitable for 15mm dia pipe 45/60cm long for cold water as per requirement complete all as specified and as directed
Supply & fix PVC connections pipe with brass hexagonal adapters both side. Suitable for 15mm dia pipe 45/60cm long for hot water as per requirement complete all as specified and as directed
S&F in repairs cable PVC insulated 3 core 2.5 Sqmm with stranded copper conductor 1100V grade from socket/switch to geyser complete all as specified and as directed.
S&F in repairs cable PVC insulated 3 core 4.0 Sqmm with stranded copper conductor 1100V grade complete all as specified and as directed.
Supply and replace multi core flexible copper conductor PVC insulated and sheathed cables 2core 0.75 Sqmm 1100Volt all as specified and directed
Supply and replace flat twin 4 Sq mm with alumanium conductor multi strand black cable as per IS 694-1990 all as specified and directed
Supply and replace flat twin 6 Sq mm with alumanium conductor multi strand black cable as per IS 694-1990 all as specified and directed
S&F in replacement MCCB 4 pole 63 Amp, Icu =10 KA, 415 volts, 50 Hz, type with thermal magnetic release duly connected with copper spreader links 04 Nos and proper size of lugs, nuts bolts and washers for proper connections all as specified and directed. (Make :- L&T or Equivalent in Legrand / HPL (O safe ))
S&F in replacement MCCB 4 pole 250 Amp, Icu = 25 KA, 415 volts, 50 Hz, type with thermal magnetic release duly connected with copper spreader links 04 Nos and proper size of lugs, nuts bolts and washers for proper connections all as specified and directed. (Make :- L&T or Equivalent in Legrand / HPL (O safe )
Supply and fix in repair on load Change over switch 200 Amps TPN with enclosure and proper size of lugs, nuts bolts and washers for proper connections all as specified and directed. (Make :- L&T (CO22000 OOOA ) or Equivalent in Legrand / HPL (O safe)
Supply and Fix LED security light 25Watts in aluminium housing with glass cover with suitable dia GI pipe bend to shape existing including taking down existing any type security light all as specifed and directed.
Supply and Fix LED security light 35/36 Watts in aluminium housing with glass cover with suitable dia GI pipe bend to shape existing including taking down existing any type security light all as specifed and directed.
Supply and Fix post top lantern 70 Watts including taking down existing any type of fitting Make - Bajaj (Celesta ) or equivalent in Havells/Bajaj/HPL/WIPRO
Supply and Fix post top lanter 35/40 Watts including taking down existing any type of fitting Make - Bajaj (Arian ) or equivalent in Havells/Bajaj/HPL/WIPRO
Supply and Fix LED Flood light 40 Watts including taking down existing any type of fitting Make - SYSKA / WPRO / HPL / JAGUAR or equivalent in Havells / Bajaj / HPL / WIPRO complete all as specified and as directed.
Repairing and rewinding of Constant Voltage transformer of any size,replacing the rectifier, Relays, Rotary switch, Fuse, indicator, including internal copper wiring and lugs etc complete all as directed by Engineer-in-Charge.
Disconnecting and dismentling online UPS of upto 15 KVA capacity and removing all the cleaning and removing moisture from ups present in it and testing of self diagnostic with on load testing and refixing the same it position including replacement of unserviceable items complete all as directed by Engineer-in-Charge. (Note - Unserviceable items replaced will be measured and paid separately)
Supply and replacement of micorprosser based online UPS drive card complete all as directed.
Supply and fix 12 volts sensing transformer card ups complete all as directed.
Supply and replace panel fan for UPS of any capacity complete all as specified and directed
S&F in replacement MCCB 4 pole 125 Amp, Icu = 18 KA, 415 volts, 50 Hz, type with thermal magnetic release duly connected with copper spreader links 04 Nos and proper size of lugs, nuts bolts and washers for proper connections complete including MS enclosure of suitable size all as specified and directed. (Make :- L&T (DBVTL004DD ) or Equivalent in Legrand / HPL (O safe )
S&F in replacement MCCB 4 pole 200 Amp, Icu = 18 KA, 415 volts, 50 Hz, type with thermal magnetic release duly connected with copper spreader links 04 Nos and proper size of lugs, nuts bolts and washers for proper connections complete including MS enclosure of suitable size all as specified and directed. (Make :- L&T (DBVTL004DD ) or Equivalent in Legrand / HPL (O safe )
Supply and fix modular switch of capacity 6 Amps,SP,1 module suitable for OT room complete all as specified and directed. (Make- Legrand Arteor or equivalent in Havells/ HPL)
Supply and fix modular switch of capacity 20 Amps, SP one module suitable for OT room complete all as specified and directed. (Make- Legrand Arteor or equivalent in Havells/ HPL)
Supply and fix modular mirror white glass plate 2 module suitable for OT room complete all as specified and directed. (Make- cat part no 5757 14 of Legrand Arteor or equivalent in Havells/ HPL)
Supply and fix modular mirror white glass plate 4 module suitable for OT room complete all as specified and directed. (Make- cat part no 5757 34 of Legrand Arteor or equivalent in Havells/ HPL)
Supply and fix modular mirror white glass plate 2 x 6 module suitable for OT room complete all as specified and directed. (Make- cat part no 5757 74 of Legrand Arteor or equivalent in Havells/ HPL)
Supply and fix modular socket of capacity 6 Amps, 2/3 pin suitable for OT room complete all as specified and directed. (Make- Legrand Arteor or equivalent in Havells/ HPL)
Supply and fix modular socket of capacity 6/16 Amps, 3 pin suitable for OT room complete all as specified and directed. (Make- Legrand Arteor or equivalent in Havells/ HPL)
Supply and fix single pointed air termination aluminium rod , 12 mm dia, 600 mm long complete all as specied.
Supply and fixing aluminium strip 25mm x 3 mm complete with insulators at a interval of 60 cm distance and fixing screws as roof/ wall /RCC OH reservoir/ GI Pipe/ verticle in wall of bldg of AICTS complete all as specified.
Supply and fixing GI strip 32 mm x 6 mm complete and buried in ground as ground conductor complete all as specified .
M & L for Test point terminal block made of gun or phosphorus bronze size 75 x 75 x 25 mm, drilled and secrewed including 3 nos 8mm dia 25 mm long hex. Head screw complete including MS enclosure of suitable size all as directed complete.
M & L for PCC (1:2:4) type C-1 (using 20 mm aggregate) as fixing of pipe on roof for air teriminators etc including form work & finishing the surfaces even & smooth with out using extra cement for fixing of insulator and terminal pipe complete all as specified and as directed.
Supply and fix GI pipe 25 mm dia medium grade welded with 25 x 3 mm strip at interval of 600 mm drilled for fixing insulator and aluminium strip complete all as specified and as directed. (Note- Aluminium strip along with insulator will be measured and paid separately
M&L for Earthing complete with galvanised iron earth plate electrode of size 600x 600x 6 mm buried directly in ground (earth pit not less than 2.25 metre deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to galvanised iron strip 32 X 6 mm by means of GI bolts/nuts/washers, protected by 40 mm bore GI mediumgrade pipe. Earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15 cm thick all around bottom and top. 20 mm bore GI medium grade pipe for watering and including funnel, wire mesh,RCC cover & frame, PCC (1:3:6) type C2 (using 20 mm graded crushed stone aggregate) as in earthing pit including necessary excavation & earth work, all as specified & shown in electrical plate No. 3 of MES Schedule Part – I. connected to earthing test point Including testing on completion (NOTE :- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) The unit rate includes earthing lead & protection pipe upto 7.5 metre from top of earth plate.)
Supply and Fix LED bldg security light 25Watts in aluminium housing with glass cover with suitable dia GI pipe bend to shape existing including taking down existing any type security light all as specifed and directed (Make -JAGUAR (PCR ) equivalent in Havells / Bajaj / HPL / WIPRO)
Supply and Fix post top lanter 70 Watts including taking down existing any type of fitting Make - Bajaj (Celesta ) or equivalent in Havells/Bajaj/HPL/WIPRO
Supply and Fix post top lanter 35/40 Watts including taking down existing any type of fitting Make - Bajaj (Arian ) or equivalent in Havells/Bajaj/HPL/WIPRO
Supply and Fix LED Flood light 40 Watts including taking down existing any type of fitting Make - SYSKA/WPRO/HPL/JAGUAR or equivalent in Havells/Bajaj/HPL/WIPRO
S&F LED flood lights fitting 140 watts with die cast aluminium housing and toughened glass cover Specially designed for LED Floodlight luminaire with energy saving and advance optical system including MS angle iron clamp with nut bolt grout with fastner 3" long complete suitable for LED flood light fitting conforming to CAT Part No JETAIRISFLS140WLED730SYMLTG of Havells and equivalent in Bajaj/ Wipro/Phillips complete all as specified and as directed.
Taking down old unserviceable APFC panel and Design, supply,install, test and comissioning of vermin proof Automatic power factor control panel 60 KVAR out door installation factory made both front and rear side double door system, fabricated with 3.15 mm thick CRCA sheet for load bearing members and 2 mm thick for doors and covers and shall be painted witrh epoxy powder paint by means of electro static gun after rigorous pre treatment comprising of cold phosphating process on all internal and external surfaces after due preparation of surfaces. The panel shall consist of 200 ,Amps rating TPN bus bars of high conductivity aluminium alloy and shall be provided with colour coded heat shrinkaable sleeves,with more depth for accommodating Capacitor bank 10 Nos inside of the panel. The panel shall be modular/cubical trype with bus chamber cable allyand provided with separate fully compartments for each switch including instrumentation such as Ampere Meter, Volt meter, Phase indicating lamp with double stud hinged door , front and rear openable with locking arrangement and suitable for 1100 Volts grade , 3 phase 415 Volts , 50 cycles , AC Supply and to with stand short circuit fault level of not less than 10 KA and degree of protection shall be IP 54 . The panel shall be fixed with angle iron frame made of angles of size 50x50x6 mm , embedded 200 mm below ground level in PCC 1:2:4, Type B1 using 20 mm grade stone aggregate , 600 mm above ground level and comprising the following including taking out of old panels etc , removing of cables and connecting to new panels with all required material such as glands, lugs etc
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for taking out cable etc and repairs / laying cables etc and getting out in following type of strata complete all as specified and as directed.
Soft/Loose soil
Hard Dense soil
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed.
Removal of excavated material [soil] to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
M&L for laying of Reinforced concrete pipes,class NP2 of dia 100 mm ,2 nos half round ( for bottom and top )and before laying exacaved area shall be leveling all as specified and directed.
Supply Laying, joint, test and commission in repairs LT under ground cable 1100 V grade, XLPE insulated, armoured and sheathed with Aluminium conductor of following sizes including cable glands, lugs, jointing materials etc laid in trenches / floors / ducts all as specified and directed. (Note: Earth work and excavation shall be measured and paid separately.)
6 Sqmm 4 core
10 Sqmm 4 core
PURVA ELECTRICALS AND ENGINEERS
UNIQUE ENGINEERS
M/S. Niksun Electro-Infra Private Limited
Reliable Enterprises
G V HAGAWANE
metro electrical services
M/S - SUJIT ELECTRICALS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .