| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.7 LAccepted-AOC 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | ₹13.7 L Quoted ₹14.2 L | L1 | Accepted-AOC Being lowest tenderer |
| 2 | L2₹14.8 L+₹52,330 (3.68%)Rejected-Finance H 13 GEETANJALI PARK WEST SAGARPUR NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | ₹14.8 L+₹52,330 (3.68%) | L2 | Rejected-Finance Being not lowest tenderer |
| 3 | L3₹17.7 L+₹3.5 L (24.4%)Rejected-Finance | ₹17.7 L+₹3.5 L (24.4%) | L3 | Rejected-Finance Being not lowest tenderer |
| 4 | L4₹19.9 L+₹5.7 L (39.7%)Rejected-Finance WZ 409 0 B 1ST FLOOR PLOT NO 12 JANAK PARK HARI NAGAR NEW DELHI 110064 | NEW DELHI | WEST DELHI | DELHI | 110064 | ₹19.9 L+₹5.7 L (39.7%) | L4 | Rejected-Finance Being not lowest tenderer |
Tender Value
₹30.9 L
EMD Value
₹61,880
Closing Date
8 Jun 2022, 6:00 pmClosed
CWE(AF) Tughlakbad
HQ CWE(AF) Tughlakbad, New Delhi-110080
REPAIR/MAINT OF AIR CONDITIONING PLANT AND OTHER CONNECTED WORKS AT BRD UNDER GE(AF) (P) GURGAON
2022_MES_523771_1
CWE/TKD/GUR/TOKEN-07/2022-23
Open Tender
Electrical and Maintenance Works
Works
180 days
GE (P) AF GURGAON
As per NIT documents
8 documents required · 8 mandatory
₹500
GE (P) AF GURGAON
₹61,880
Yes
14 Jul 2022
12 May 2022
10 Jun 2022
12 May 2022
8 Jun 2022
26 May 2022
Amount
M&L for Opening of all condenser of each plant cover of both sides including disconnecting of water pipe line for inlet and outlet of the condenser of each plant. Removing scale/sludge precipitated in the copper tube by push and pull method with iron rod connected with steel wire brush of suitable size as per condenser copper tube size at the entire length of condenser by scraping down . Closing both side of condenser and circulating the descaling soulation in all tube of all condensers of each plant through the cidsrculating pump and allows holding it for 30 minutes for chemical descaling. Opening the condenser both sides and clean with iron road connected with nylon brush of suitable size as per condenser copper tube size at the entire length of condenser ensure that descaling process has been complete then closing the condenser at both end and circulating clean water in all tubes including condenser of each oplant and drain out the process will continue till the satisfaction of Engr-in-Charge then fixing new gasket for both ends of the all condenser of each plant tighten with new nut end bolt for the following plants :- Notes :- (i) Necessary T&P such as pump, tube, descaling solution etc shall be arranged by the contractor without any extra cost to Department. (ii) Descaling of all condensers in one AC plant shall be considered as one job.
(a) Old Parachute building AC Plant 16 BRD-3 x30 TR Capacity
(b) Radar Lab AC Plant at 13 BRD-3 x 50 TR Plant Capacity
(c) Communication Lab AC Plant at 13 BRD- 3 x 75 TR Plant capacity
(d) Std & Call Lab AC Plant at 13 BRD- 3 x 11 TR Plant Capacity
(e) New Parachute building at 13 BRD - 3 x 35 TR Plant Capacity
M&L for Pressure testing for entire system of the following AC plant of all condenser, compressor and circulating system with CO2/Nitrogen gas and retain to allow the pressure for three days. If found any leakage or reduction in the scale of pressure shall be located and arrest the leakage immediately by soldering or an appropriate measure are to be taken to stop the leakage premanently :- (a) Old Parachute building AC Plant 16 BRD-3 x30 TR Capacity. (b) Radar Lab AC Plant at 13 BRD-3 x 50 TR Plant Capacity. (c) Communication Lab AC Plant at 13 BRD- 3 x 75 TR Plant capacity. (d) Std & Call Lab AC Plant at 13 BRD- 3 x 11 TR Plant Capacity. (e) New Parachute building at 13 BRD - 3 x 35 TR Plant Capacity. Note: Pressure testing report shall be generated/prepared and send to GE office along with RAR payment.
Cleaning the cooling tower by applying wire brush, washing powder and other solvent by removing the deposited impurities sush as silt, dust particles mud/ sand inside the dume and around the fins, on wiremesh, main shaft etc and other connected items complete all as specified and directed by Engineer-in-Charge:- (a) Old Parachute building AC Plant 16 BRD-3 x30 TR Capacity. (b) Radar Lab AC Plant at 13 BRD-3 x 50 TR Plant Capacity. (c) Communication Lab AC Plant at 13 BRD- 3 x 75 TR Plant capacity. (d) Std & Call Lab AC Plant at 13 BRD- 3 x 11 TR Plant Capacity. (e) New Parachute building at 13 BRD - 3 x 35 TR Plant Capacity.
M&L for Vacuum the system and after maintaining vacuum of 70 cm of mercury for 24 hours supply and charging refrigerant gas R134/R22/R407 as per existing complete all as specified and directed. Note: During testing the charge in vaccum shall not exceed 12 cm of mercury the aspect shall be verified by AGE and report shall be generated and signed by all party and fwd to GE office along with RAR payment. .
(a) Old Parachute building AC Plant 16 BRD-3 x30 TR Capacity (R-134)
(b) Radar Lab AC Plant at 13 BRD-3 x 50 TR Plant Capacity (R407)
(c) Communication Lab AC Plant at 13 BRD- 3 x 75 TR Plant capacity(R407)
(d) Std & Call Lab AC Plant at 13 BRD- 3 x 11 TR Plant Capacity(R22)
(e) New Parachute building at 13 BRD - 3 x 35 TR Plant Capacity(R407)
M&L for rewinding of induction electric motor 5 HP 3 phase AC motor 415V capacity of any make and size complete with super enameled copper winding wire of exiting gauge to get same capacity of motor including varnishing and replacement of insulated material complete as specified and directed by Engr-in-Charge. Note: Taking out, transporting charges, refixing and testing of motor shall be included in quoted rates.
M&L for rewinding of induction electric motor 7.5 HP3 phase AC motor 415V capacity of any make and size complete with super enameled copper winding wire of exiting gauge to get same capacity of motor including varnishing and replacement of insulated material complete as specified and directed by Engr-in-Charge. Note: Taking out, transporting charges, refixing and testing of motor shall be included in quoted rates.
M&L for rewinding of induction electric motor 15 HP 3 phase AC motor 415V capacity of any make and size complete with super enameled copper winding wire of exiting gauge to get same capacity of motor including varnishing and replacement of insulated material complete as specified and directed by Engr-in-Charge. Note: Taking out, transporting charges, refixing and testing of motor shall be included in quoted rates.
M&L for rewinding of induction electric motor 50 HP capacity of any make and size complete with super enameled copper winding wire of exiting gauge to get same capacity of motor including varnishing and replacement of insulated material and replacement of ball bearing complete all as specified and directed by Engr-in-Charge. Note: Taking out, transporting charges, refixing and testing of motor shall be included in quoted rates.
M&L in repair of mono-block Centrifugal pump set with Motor Capacity 7.5 HP including replacement of shaft,impeller,casing,nut & bolts etc as required to be replaced.complete all as specified and as directed by Engr In Charge. CROMPTON/DLF AUE(UNIVERSAL)/KIRLOSKAR
M&L in repair of mono-block Centrifugal pump set with Motor Capacity 5 HP including replacement of shaft,impeller,casing,nut & bolts etc as required to be replaced.complete all as specified and as directed by Engr In Charge. CROMPTON/DLF AUE(UNIVERSAL)/KIRLOSKAR
M&L in repair of mono-block Centrifugal pump set with Motor Capacity 3 HP including replacement of shaft,impeller,casing,nut & bolts etc as required to be replaced.complete all as specified and as directed by Engr In Charge. CROMPTON/DLF AUE(UNIVERSAL)/KIRLOSKAR
S&F as in repairs thermostat expansion valve suitable for the following capacityof plant (Total-05 Nos) Make:-PARKER SPORLAN/DANFOSS/RANCO (a) Old Parachute building AC Plant 16 BRD-3 x30 TR Capacity. (b) Radar Lab AC Plant at 13 BRD-3 x 50 TR Plant Capacity. (c) Communication Lab AC Plant at 13 BRD- 3 x 75 TR Plant capacity. (d) Std & Call Lab AC Plant at 13 BRD- 3 x 11 TR Plant Capacity. (e) New Parachute building at 13 BRD - 3 x 35 TR Plant Capacity.
Removing of Hepa filter all sizes existing at site from its position and layout at site for refixing after clearing, AHU cooling coil using chemical with brass brush in-order to remove all type of sludge/dust precipitatated on the coil without any damage to the copper cooling coil then wash the cooling with fresh water and air blower upto the satisfaction of Engr-in-Charge. Cooling coil drain water shall be clean, if any type of obstacle on the flow of water, iron body of the AHU inside and outside shall be scrap down and rub out with sand paper then apply one coat primer and one coat of synthetic enameld paint the AHU shall be completed upto the satisfaction of Engr-in-Charge for the following AC plant :-
(a) AHU of Old Parachute building AC Plant 16 BRD-3 x30 TR Capacity
(b) AHU of Radar Lab AC Plant at 13 BRD-3 x 50 TR Plant Capacity
(c) Communication Lab AC Plant at 13 BRD- 3 x 75 TR Plant capacity
(d) AHU of Std & Call Lab AC Plant at 13 BRD- 3 x 11 TR Plant Capacity
(e) AHU of New Parachute building at 13 BRD - 3 x 35 TR Plant Capacity
M&L for painting of AC plant as per existing colour including compressor, condenser, motor, chiller pump, AHU, cooling tower including base and all pipeline & connected valve including wiriting SM/MES No. Of AC plant of capacity 3X30TR plant & 3 x 50 TR AC Plant,3x 75 TR,3 x 11 TR, 3 x 35 TR Plant by removal of old paint and applying two coats of paint complete all as specified and as directed by Engineer-in-charge.
Detecting the fault of any capacity of AC Plants and any location by providing skilled Refrigerent Mechanic/SkIlled Elect & helper with necessary safety and working equipment and other reqd tools and plants and rectify the defects on top priority basis/as and when reqd including testing, complete all as specified and directed by Engineer-in-Charge.
T&P and Labour for disconnecting the condesing line /chiller line (Condencer/Chiller to AHU) detect the Line blockage and rectify blockage and refixing the line and testing completed completed all as specified and as directed.
S&F in replacement of Cast Iron butterfly valve (water Type) without lugs, lever operated, SS 304 Disc, Nitrile /EPDM rubber lining test pressure PN-1.6 by replacing the existing 80 mm dia, complete all as specified and as directed by Engr-in-Charge. Make : Zoloto Cat No 1078B or equivalent/Leader/castle/Advance
S&F in replacement of Cast Iron butterfly valve (water Type) without lugs, lever operated, SS 304 Disc, Nitrile /EPDM rubber lining test pressure PN-1.6 by replacing the existing 100 mm dia, complete all as specified and as directed by Engr-in-Charge. Make : Zoloto Cat No 1078B/Leader/castle or equivalent
M&L for replacement of non freezing oil N-68 complete all as specified and as directed by Engineer-in-charge. Make:- Castrol/ Servo
S&F in replacement of of electronic circuit board (Display) of AC plant by OEM service engineer removing defects including replacement of all unserviceable spares and testing complete all as specified and as directed by Engineer-in-charge. Make Voltas /Bluestar
S&F in replacement of AHU pre filters EU4 /G4 of size 610X610X50mm having filteration capacity .3 to 1.0 micron of 95% efficiency as per sample complete all as specified and as directed by Engineer-in-charge (Make-Thermadyne Pvt Ltd/Universal Industries/Abc Solutions or equivalent
S&F in replacement of AHU pre filters EU4 /G4 of size 610X305X50mm having filteration capacity .3 to 1.0 micron of 95% efficiency as per sample complete all as specified and as directed by Engineer-in-charge. (Make-Thermadyne Pvt Ltd/Universal Industries/Abc Solutions or equivalent
S&F in replacement of AHU pre filters EU4 /G4 of size 305X610X50mm having filteration capacity .3 to 1.0 micron of 95% efficiency as per sample complete all as specified and as directed by Engineer-in-charge. (Make-Thermadyne Pvt Ltd/Universal Industries/Abc Solutions or equivalent
S&F in replacement of AHU pre filters EU4 /G4 of size 305X305X50mm having filteration capacity .3 to 1.0 micron of 95% efficiency as per sample complete all as specified and as directed by Engineer-in-charge. (Make-Thermadyne Pvt Ltd/Universal Industries/Abc Solutions or equivalent
Supply and fixing in replacement of Galvanized Iron fly wheel gate valve size 50 mm complete all as specified and as directed by Engr In Charge.(Make-Zoloto/Kirloskar/Kartaror equivalent)
Dismantling and taking down from existing duct of various sizes upto 1400mm for Inner duct cleaning, servicing, denting, at site AC Plant and Air washer and re-fixing the same including replacement of gasket, nut & bolts etc complete all as specified and as directed by Engineer-in-charge.
S&F in replacement of Pressure Gauge with replacement of connected rusted out pipeline complete as specified and direcetd as site.Make H-Guru/PIGBIG (Range-0-150 psi)
S&F in replacement of Temp Gauge as per matching to existingtype with replacement of connected rusted out pipeline complete as specified and direcetd as site. Make H-Guru/PIEBIG.(Range- -20c to 50 c
S&F in replacement of Siphon as per matching to existing type with replacement of connected rusted out pipeline complete as specified and as directed as site.
M&L for Pump down the existing refrigerant in separate cylinder. Disconnecting of electric motor of compressor refrigerant line gauges pipe opening and dismantle of reciprocating compressor for general overhauling ,carry out the inspection of compressor, carry out general overhauling of compressor replacement of springs, aluminum washer packing screw work cleaning detergent cotton waste, etc and cleaning the suction filter oiul filter replacing the defective parts. Assembling the compressor tessting for leakage with nitrogen gas and rectify them. Re-charging of refrigerant R-22/R-407as per existing compressor oil and testing on connected load the compressor all as directed by Engr-in-charge. Note :(1) spares and compressor and refrigerant shall be measured and paid separately as under and disconnecting,Transporting and refixing charges included in this job and no extra payment shall be admissible.(2) Work to be carried out through OEM rep
(a) Supply only piston pin bush
(b) Supply only overhauling gasket set SMC 8 X 100
(c) Supply only suction rod
(d) Supply only discharge rod
(e) Supply only piston ring
(f) Supply only piston
(g) Supply only cylinder liner
(h) Supply only main bearing
(j) Supply only CR bearing
(k) Supply only discharge valve assy
(l) Supply only piston pin
(m) Supply only oil pump coupling
(n) Supply only oil pump repair kit
(o) Supply only shaft seal
(p) Supply only oil regulating valve
(q) Supply only compressor oil
(r) Supply only oil filter cartriage
S&F in replacement of MCCB 415V AC with thermal adjustable fixed magnetic setting four pole 400 Amps 36 KA complete all as specified and as directed by Engineer-in-charge. Make: Havells/Legrand/L&T
S&F in replacement of MCB TPN upto 40 TO 100 AMPS 10KA as per sample complete all as specified and as directed by Engineer-in-charge. Make Indo Asian/ L&T/Legrand
S&F in replacement of aluminium sprinkler 3'X63mm with MT complete make active cooling tower complete all as specified and as directed by Engineer-in-charge.(For 3X11 TR, 3X50 TR,3X30 which consists of 05 cooling towers)Make: Delta/Mihir/Universal:
M&L in repair of AHU motor suitable for AC plants/Dehumidifier unit/Air washer of motor by dismantling it from weather making unit of AHU, replacement of Bushes, bearings by opening nuts bolts and removing electrical connections of the motor, replacement of stator and rotor assembly, replacement and alignment of shaft, complete all as specified and as directed by Engr-in-Charge.
3HP to 4 HP AHU fan motor
5 HP AHU fan motor
7.5 HP AHU fan motor
10 HP AHU fan motor
15 HP AHU fan motor
S&F in replacement of duct filter suitable for AC plant of size 600X600X150mm filter media capacity shall capable 5 micron as per existing make air flow complete all as specified and as directed by Engineer-in-charge.
M&L in replacement of high pressure/Low Pressure/oil pressure Cutout for R134 complete all as specified and as directed by Engineer-in-charge. Make: Danfoss/ Indofoss
S&F in replacement of M S Pipes heavy grade with all fittings laid in floors or fixed to walls and ceilings etc of sizes 80mm existing including bending and welding work and testing complete this job complete all as specified and directed by Engr in charge.Make :- Jindal/Tata or equal
S&F in replacement of M S Pipes heavy grade with all fittings laid in floors or fixed to walls and ceilings etc of sizes 100mm existing including bending and welding work and testing complete this job complete all as specified and directed by Engr in charge. Make :- Jindal/Tata or equilvalent.
S&F in replacement of MCCB 415V AC with thermal adjustable fixed magnetic setting four pole 250 Amps 36 KA complete all as specified and as directed by Engineer-in-charge. Make: Havells/Legrand/L&T
S&F in replacement of MCCB 415V AC with thermal adjustable fixed magnetic setting three pole 100 Amps 36 KA complete all as specified and as directed by Engineer-in-charge. Make: Havells/Legrand/schinider/L&T
S&F in replacement rotational moulded polyethylene water storage tanks (Cylendrical, vertical with openable lid with three layer) hoisted and fixed in position all as directed capacity 5000 Ltrs.
S&F in replacement fan belt of Size B-104 complete all as specified and directed.(Make-omfa rubbers/jagruti rubbersmercury rubbers or equivalent)
S&F in replacement fan belt of Size B-110 complete all as specified and directed. .(Make-omfa rubbers/jagruti rubbersmercury rubbers or equivalent)
S&F in replacement fan belt of Size B-78 complete all as specified and directed. .(Make-omfa rubbers/jagruti rubbersmercury rubbers or equivalent)
S&F in replacement fan belt of Size B-121complete all as specified and directed. .(Make-omfa rubbers/jagruti rubbersmercury rubbers or equivalent)
S&F in replacement fan belt of Size B-69 complete all as specified and directed. .(Make-omfa rubbers/jagruti rubbersmercury rubbers or equivalent)
S & F in repair three way solenoid valve suitable for central type AC plant of any capacity complete all as specified and directed. Make of Solenoid valve: Accel Cat Part No.U-1N or equivalent model of Sporlene/ Danfoss/ Emerson
Supply, installation, testing and commissioning in replacement sprinkler assembly for cooling tower of following capacity complete all as specified and as directed. Make: Delta/Mihir/Universal: -
For 3X35 TR DELTA, MODEL-5035 & 9032
For 3X75 TR MAKE -DELTA, MODEL-5064
S&F in replacement 3 pole power contactor 415 V, type including NO or NC auxiliary contact BLOCK , Coil voltage 230 V, 50 Hz including connecting complete all as specified and directed. Make:- Indo Asian/ L&T/Legrand/MNX 18 of L&T or equailvalent Legrand Havells/Seimens
S&F in replacement 3 pole power contactor 415 V, type MNX 32 including NO or NC auxiliary contact block, coil voltage 230 V including connecting complete all as specified and directed. Make:- SIEMENS/L&T/ or equailvalent Legrand Havells/Seimens
S&F in replacement of Cooling tower fan motor 05 HP 415V complete all as specified and directed.Make:- CROMPTON/DLF AUE(UNIVERSAL)/KIRLOSKAR
S&F corrosion proof PVC fills and inlet louvers, drift, eliminators hot water distribution chamber and nozzles etc including dismantling of existing PVC fills from the induced draft type cooling tower of fibre glass reinforced plastic (FRP) casting rectangular/other type construction suitable for following capacity Cooling tower including all accessories complete all as specified and directed: - Delta, Model - 5064
S&F in replacement of FUSE 3NWT5S-125 Ampcomplete all as specified and directed. Make: SIEMENS/L&T
S&F in replacement of FUSE 3NWT5S-200 Ampcomplete all as specified and directed.Make:-SIEMENS/L&T
S & F in replacement MCB, TP, 'C Curve', 25- 63Amp complete all as specified and as directed.Make Indo Asian/ L&T/Legrand
S & F in replacement MCB, TPN, 'C Curve',16-32 Amp complete all as specified and as directed.Make Indo Asian/ L&T/Legrand
M&L for taking out Cooling Tower Motor of following capacity, opening the motor, cutting & removing old burnt winding wire, rewinding the motor with new super enamelled copper winding wire of size & description to match with the existing including insulating materials, varnishing, drying, replacement of both driven end, non driven end bearings and base plate, reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed :-
5 HP Cooling Tower Motor 3 Phase, 415 V AC
7.5 HP Cooling Tower Motor 3 Phase, 415 V AC
M & L in replacement rewinding the motor of Chiller pump (Centrifugal pump) of following capacities with new super enamelled copper winding wire of size & description to match with existing including insulating materials, varnishing and drying, reassembling including cutting & removing old burnt winding wire complete all as specified & directed: -
Condenser/Chiller Pump of capacity 5 HP
Condenser/Chiller Pump of capacity 7.5 HP
Condenser/Chiller Pump of capacity 10 HP
Condenser/Chiller Pump of capacity 15 HP
S&F in replacement Pot strainer, flanged type, suitable for pipes of 125 mm internal dia including cutting, welding of pipe up to required size with flange including taking down the existing unserviceable Pot strainer complete all as specified and directed.
S&F in replacement Pot strainer, flanged type, suitable for pipes of 150 mm internal dia including cutting, welding of pipe up to required size with flange including taking down the existing unserviceable Pot strainer complete all as specified and directed.
Taking down existing Pump motor of following size from base plate foundation with dismantling of rubber coupling and necessary nuts and bolts along with pipe, cutting all connected accessories as required, and then dismantling the cracked PCC foundation(1:3:6) type c-2 using 40mm graded stone and foundation bolts, providing new PCC foundation with provision of new foundation bolts/Screws and M & L refixing of base plate and refixing the motor with rubber coupling with proper alignment and refixing of control wiring and power wiring all connected accessories as required complete all as specified and as directed.
For 5 HP Pump motor
For 7.5 HP Pump motor
For 15 HP Pump motor
S&F in repair prefabricated type cable tray of existing size fabricated out of perforated hot dip galvanised sheet, minimum 1.6mm thick, with 50mm flange to be installed horizontally or vertically, including provision of bends, elbows, cross, tees, reducers etc. as required at site, including anchor fasteners, screw, nuts, bolts, and misc items and other fixing hardware, painting of support structure etc as required complete all as specified and as directed.
Supply & fixing in replacement non return valve PN-1.6 IS 5312 Part -I. 80 mm dia both ends flanged heavy duty including packing materials, nut bolts washer etc. and testing complete including modification/ fabrication if required & having details as Body Cover CI IS : 210, Gr. FG260. Body Rings - Bronze : IS 318 Gr. LTB2. Hinge Pin-SS ASTM A276 Type 410. Flange Drilling - IS 1538, Make :
Supply & fixing in replacement non return valve PN-1.6 IS 5312 Part -I. 100 mm dia both ends flanged heavy duty including packing materials, nut bolts washer etc. and testing complete including modification/ fabrication if required & having details as Body Cover CI IS : 210, Gr. FG260. Body Rings - Bronze : IS 318 Gr. LTB2. Hinge Pin-SS ASTM A276 Type 410. Flange Drilling - IS 1538,
Notes for ser item 01 to 66 :- 1. All the complaint registered before 1000 Hrs of every day shall be rectified on same day upto 1700 Hrs. Any delay in complaint rectification a penalty shall be recovered @ Rs.100/ per complaint per day. Fan Rewinding and Point Wiring/ sub-main wiring repair shall be done within 48 Hrs from date of complaint. After 48 Hrs panelty may be imposed on contractor as decided by Engineer-in-charge. 2. Old Unserviceable Fans shall be deposited in MES store. Any desturbed surface during execution of work shall be made good as existing. Nothing extra shall be paid in this respect. The quoted rate are deemed to be included the same cost.
Schedule of credit (Details at Srl page no. 20®
J.P. Enterprises
Satish Kumar Gupta
Flint India
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .