Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.6 LAccepted-AOC | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹8.7 L+₹12,005 (1.40%)Rejected-AOC NICHUPATTY BOLPUR BIRBHUM | BIRBHUM | WEST BENGAL | 713129 | L2 | Rejected-AOC Being L2 Bidder | |
| 3 | L3₹8.7 L+₹17,039 (1.99%)Rejected-Finance | L3 | Rejected-Finance Being L3 Bidder | |
| 4 | L4₹8.8 L+₹21,555 (2.52%)Rejected-Finance | L4 | Rejected-Finance Being L4 Bidder |
Tender Value
Refer Docs
EMD Value
₹17,567
Closing Date
2 Jul 2025, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer, Birbhum Electrical DivisionPWD
Ofc The EXECUTIVE ENGINEER P.W.DTE Birbhum Electrical Division P.O. Suri,Dist Birbhum Pin 731101
Electrical Installation work for power supply of 10 bedded Dialysis Unit including RO Plant at Bolpur Sub Divisional Hospital, Birbhum. RN25000535 Project ID HF252635484S000.
2025_WBPWD_866218_1
BIRED/05/e-NIQ(1st call) of 2025-2026
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
Bolpur
Please refer Tender documents.
4 documents required · 4 mandatory
₹17,567
Executive Engineer, Birbhum Electrical DivisionPWD
30 Jan 2026
18 Jun 2025
4 Jul 2025
18 Jun 2025
2 Jul 2025
23 Jun 2025
23 Jun 2025
Amount
Laying of one cable above 150 sqmm and upto 300 sqmm through existing covered masonry trench incl. taking out RC covers, setting them in order, mending good the damages filling the trench with fine dry sand incl. supplying sand.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : 4 Core 300 Sq. mm
Finishing the end of following XLPE/PVC armoured cables by crimping method as per GS 4 Core 300 Sq. mm
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment as below size : i) Up to 250A 8 way Legrand make
ii) Up to 160A 8 way Legrand make
Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for TPN DB horizontal / vertical enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish with nuts bolts etc incl. provision for earthing attachment. for 8 way VTPN
Supplying and fixing MCCB SS enclosure with IP- 20/30 protection, pwder coated provision for housing Four pole (4P) MCCB, on flat iron frame incl. painting, connection & provision for earthing attachment, Legrand make. (For 63A RO Plant MCCB )
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection. Legrand make, as below rating : i) 250A.
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. Legrand make. i) 125 A TP
ii) 100 A TP
iii) 63 A TP
Supplying & Fixing of PVC water proof type Loop box (Make-Sintex GSJB4030) of size [400X300X190]mm having hinged PVC top cover & 4 mm thick with rubber gasket lining,railway type mechanical locking arrangement.
Supply & Fixing of channel mounted copper terminal Bus in existing Loop Box of 160A incl S&F mounting channel.
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand Polycab/Finolex/RR Kabel/Gloster) in 25mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required 2x80/0.4 (10 sqmm) as ECC
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand Polycab/Finolex/RR Kabel/Gloster) of the following sizes in the 32mm dia HMS grade PVC rigid conduit with all accesseries and making necy. connection as required. 4x126/0.4 (16 sqmm) + 2x80/0.4 (10 sqmm) as ECC
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand Polycab/Finolex/RR Kabel/Gloster) of the following sizes in the 50 mm dia HMS grade PVC rigid conduit/PVC Flexible conduit with all accesseries and making necy. connection as required. 4x396/0.4 (50 sqmm).
Finishing of the PVC insulated wire ends by socketting with pin/ ring type Long barrel copper sockets and insulated tapes etc., including supplying sockets, tapes. i) 10sqmm
ii) 16sqmm
iii) 50sqmm
Supply of 4 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make- Havells/RR /Universal/ Polycab/ As per choice of EIC) i) 4 Core 95 Sq mm ( From S/S to Dialysis unit)
ii) 4 Core 35 Sq. mm ( From Dialysis unit to RO Plant & RO plant area Lighting)
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : i) 4 Core 95 Sq mm
ii) 4 core 35 sq mm
Finishing the end of following XLPE/PVC armoured cables by crimping method as per GS i) 4 Core 95 Sq mm
ii) 4 core 35 sq mm
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required i) 50 mm dia
ii) 65 mm dia
Laying of one cable upto 150 sqmm through existing covered masonry trench incl. taking out RC covers, setting them in order, mending good the damages filling the trench with fine dry sand incl. supplying sand (For 4 Core 95 Sq mm)
Laying of one No. cable above 35 sqmm and upto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed. ( 4 core 95 Sq mm)
Laying of cable above 4 core 90 sqmm and upto 4 core 150 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting
Laying only Cable above 50 sqmm but not exceeding 400sqmm through existing RCC/ Hume/GI Pipe/open masonary trench for single, 2, 3, 3½ and 4 core
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed. (For 4 Core 35 Sq mm)
Laying of cable from 4 core 35 sqmm to 50 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mendinggood damages and painting
Laying only Cable upto 50 sqmm through existing RCC/Hume/ GI Pipe/open masonary trench for single, 2, 3, 3½ & 4 core
Supply and Installation of 3 Phase 4 Wire Meter Box by PVC water proof type Meter box (Make-Sintex GSMB-4030) of size [400X300X190]mm having hinged PVC top cover & 4 mm thick with rubber gasket lining,railway type mechanical locking arrangement, for installation of 3phase 4 wire CT operated KWH meter and 6A TP control MCB as per direction of EIC.
Energy metering arrangement: S&F 3phase 4 wire CT operated Digital KWH meter of class 0.5S accuracy with LCD disply. [Make; SECURE Premier 300/ABB/Shneider / Siemense] S&F 150/5A CT of class 0.2S accuracy. [ make Kappa/ L&T/ Gupta as per direction of EIC] with necessary 2.5sqmm Cu Wire & switable size PVC cotaded GI conduit. ( Test certificate from any GOVT lab / WBSEDCL/CESC should be submitted for meter & CTs both)
Supply of 150W led flood light of minimum 18100 lumen output with wide beam angle & front glass cover. [ make Philips, BVP283 LED181 CWFG SY5WB 150WV1/ similar of Crompton/Havells ]
S/F 200mmx250mmx100mm SMC loop box with hinged type single door fixed on wall (by 50mm X6mm flat iron frame grouted on wall) with 150mm spacing from wall. And also S&F of 4 way terminal block & one number 10KA 6A SPMCB ( Legrand make) for easy connection of existing out going cables to compound light with necessary inter connection as per direction of E.I.C. (Make-Sintex)
Fixing of flood light fittings on wall by suitable size 50mmX6mm GI bracket ( grouted on wall) with minimum 150 mm spacing from wall.
Distribution wiring in 2x2.5 sqmm single core PVC insulated stranded Copper wire in 19 mm PVC coated GI flexable conduit.
Supply & fixing of 19 mm GI flexable conduit Gland
Excavation of soil for installation of Earth Electrode and filling & ramming as per GS For Morum Soil
Earthing with 65 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 No. 50 mm x 6 mm galvanized (Hot Dip) steel strip (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including finishing both ends by making holes etc. and S & F suitable heavy type heat shrinkable PVC sleeve to cover 75 mm x 8 mm GI flat, to an average depth of 3.65 Mts.
S & F 50 mm x 6 mm Galvanized (Hot Dip) MS flat on wall/floor with GI saddle as required. [ beyond 4mt for each earthing]
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 65 mm x 8 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe.
N.B: i) Payment will be made after availability of fund from concern Department. ii) Payment will be made as per P.W.D norms.
MOON LIGHT (BID ID -6659136)
AJOY KUMAR DAS (BID ID -6666064)
NIRMAN ENTERPRISE (BID ID -6666606)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .