Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.0 LAccepted-AOC | L1 | Accepted-AOC Being over all reasonable | |
| 2 | L2₹30.5 L+₹3.2 L (11.7%)Rejected-Finance | L2 | Rejected-Finance Not lowest bidder |
Tender Value
₹30.9 L
EMD Value
₹61,900
Closing Date
30 Oct 2020, 6:00 pmClosed
GE CENTRAL KIRKEE
GE CENTRAL KIRKEE RANGE HILLS ROAD KIRKEE PUNE 411003
PROVN OF CERTAIN SPECIAL REPAIR AND ADD ALT WORKS IN AGE BR II UNDER GE C KIRKEE
2020_MES_382935_1
8404/E8 OF 2020-2021
Open Tender
Civil Works
Item Rate
270 days
KIRKEE
AS PER NIT
7 documents required · 7 mandatory
₹500
Yes
GE CENTRAL KIRKEE
₹61,900
Yes
12 Dec 2020
3 Oct 2020
2 Nov 2020
3 Oct 2020
30 Oct 2020
17 Oct 2020
3 Oct 2020 - 16 Oct 2020
Amount
Excavating in trenches n. exc. 1.5 m wide and n. exc. 1.5 m in depth; for foundation etc or shafts, wells exc 10 sqm on plan and getting out any type of soil complete.
Excavating in trenches n. exc. 1.5 m wide and n. exc. 1.5 m in depth; for foundation etc or shafts, wells exc 10 sqm on plan and getting out in soft loose soil complete.
Demolition of brick work or stone/boulder masonry built in cement mortar including all quions, aches, pillars etc complete all as specified.
Demolition of brick or stone masonry of any description,including all quoins,arches,pillars etc,but excluding ashlar facings and precast cement concrete articles complete all as specified and as directed.
Demolition of unreinforced cement concrete of any description and in any position not otherwise specifically provided for in ground floor and paving (below or above ground level) complete all as specified and directed.
M&L cement concrete (1:4:8) type E - 2 using 40 mm graded stone aggregate as in foundations filling & mass concrete complete all as specified.
Returning, filling in excavated soil including spreading, levelling, watering and well ramming in layers n. exc. 25 cm in soft/loose soil complete all as specified and directed.
Removing surplus soil to a distance exc 500m but n.exc 1.5 Km and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed.
Removing excavated surplus soil/spoil to a distance not exceeding 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed.
M&L for precast cement concrete block masonry exceeding 10 cms in width built in cement mortar 1:6 of Gde C-5 complete all as specified.
M&L for PCC 1:3:6 Type C-1 using 20 mm graded stone aggregate in cills, copings, bed plate, plinth courses, roof kerbs or mud stops rounded or chamfered on edges complete all as specified.
M&L for Plain cement concrete type C-2, 1:3:6 (40 mm graded crushed stone aggregate) as in surface channels and drains complete all as specified.
M & L for providing plain cement concrete 1:2:4, type B-1 (using 20mm graded stone aggregates) as in coping,benching/haunching etc including necessary forms,moulds etc complete all as specified and as directed.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM 1:4 fair face of brick wall /PCC block masonry wall surfaces finished fair & even (without using extra cement) complete all as specified and as directed.
M & L for rendering 10mm thick CM (1:4) on concrete surfaces of walls etc, finished even and smooth without using extra cement complete all as specified and directed.
Exra for forming fair finished drain or channel of internal girth not exceeding 37.5 cm with using exra cement including all necessary forms,moulds,chamfered angles complete all as specified and directed.
Extra for forming fair finished drain or channel 41 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and directed.
Extra for forming fair finished drain or channel 57 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc.complete all as specified and directed.
Extra for forming fair finished drain or channel 74 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and directed.
M&L for Precast cement concrete 1:2:4 Type B-1 using 20 mm graded stone aggregate in landings, cover slab (for manhole etc) and similar work including necessary form work and set in CM 1:6 complete all as specified and directed.
M&L for mild steel TMT bars 8 mm dia, cut to length, bend to shape required, including cranking, bending and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M&L for reinforced concrete pipes, class NP-2 laid and jointed with collars of 300 mm bore of pipe complete all as specified and directed.
M&L for concrete bed to drain pipes including packing under and completely surrounding pipes with concrete after they are laid & tested for 300 mm bore of pipe with cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate complete all as specified and directed.
M&L for concrete bed to drain pipes including packing under and completely surrounding pipes with concrete after they are laid & tested for 450 mm bore of pipe with cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate complete all as specified and directed.
M&L for providing reinforced cement concrete hume pipes of 450mm dia, class NP-2 complete laid and bedded and fixed with collars all as specified and as directed.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM 1:2 mixing with water proofing compound 3% by weight of cement on fair faces of brick / concrete surface complete all as specified.
M&L applying evenly a coat of blown type bitumen at the rate of 1.50 kg per square metre and blinding with clean dry sand @ 0.05 cu. M. per sq. m on RCC/PCC surface all as specified.
M&L Polythene film, 50 micron thick, laid on a coat of bitumen primer, @ 0.30 to 0.50 kg per sqm complete all as specified.
M&L Plain Cement concrete 1:5:10 type E-2 as in sunken floor filling and mass-concrete all as specified.
Supply only Integral water proofing compound.
M & L for PVC 40 mm dia as in spout pipe in sunken floor complete all as specified.
Dismantling of floor hearth or wall tiling including CM bedding (but not backing) removing serviceable tiles in store and rubbish off the premises complete all as specified.
M&L for Non - skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed in cement mortar 1:6 complete all as specified.
M&L for Non - skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed in cement mortar complete all as specified.
M&L for Glazed ceramic coloured tiles as in dadoes/skirting size 450 X300X 7 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10 mm thick cement plaster (1:4) as backing coat complete all as specified.
Demolition of stone slabs/flooring of any description laid bedded and pointed any mortar all as directed.
M&L for Machine cut cudappah stone slab 20-25mm thick over cement screed base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing with and including screed bed or bedding layer 15 mm thick in cement mortar (1:6) for laying floor finishes complete all as specified and as directed.
Ditto as per Item No 37 above but on step riser skirting over and including 10mm thick rendering in CM (1:4) complete all as specified.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform and other similar situations all as specified.
M&L for 25 mm thick Cement concrete in level course for receiving floor tiles using Type B1,1:2:4 (20 mm graded aggregate) complete all as specified.
Taking down cement plaster on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified.
M&L rendering 15 mm thick in cement mortar 1:6 on stone/bricks /PCC block masonry surfaces on wall complete all as specified.
M&L for preparing of new plastered surfaces of wall and applying two coat of dry distemper over a coat of chalk whitening primer complete all as specified.
M&L for 10 mm thick rendering in cement mortar 1:3 on RCC roof slabs mixed with water proofing compound @ 3% mixed with by weight of cement finishing even and smooth to receive water proofing treatment complete without using extra cement all as specified and directed by Engineer-in-Charge.(Note : WPC shall be measured and paid separately.)
M&L for water proofing treatment over RCC slab by applying oil based bituminous primer @ 0.25 Kg/Sqm and laying 3mm thik APP modified water proofing polymeric membrane with 100 mm side and 150mm end lap having weight not less than 3.50 Kg/Sqm, reinforced with non-woven polyster reinforced matt weighing not less than 160 gms/sqm polyster core having soften point not less than 150°C, longitudinal tensile strength not less than 650 N/5cm,by torching method and applying a coat of solar reflective aluminium paint @ 0.15 Kg/Sqm on membrane surface including 24 hrs ponding test complete all as specified and as directed by the Engr-in Charge.
Taking up or down 20 mm dia steel tubing and connections, including cleaning for re- fixing or removal to store complete all as specified and as directed by the Engr-in Charge.
Taking up or down 15 mm dia steel tubing and connections, including cleaning for re- fixing or removal to store complete all as specified and as directed by the Engr-in Charge.
S & F for steel tubes 20 mm dia, medium grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by the Engr-in Charge.
S & F for steel tubes 15 mm dia, medium grade galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by the Engr-in Charge.
Cutting chases, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth in stone/ concrete block walls complete all as specified and as directed by the Engr-in Charge.
S&F in repair sinks with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and as directed by the Engr-in Charge.
S & F in repair vitreous china WHB, size 550 mm X 400 mm make:- Parryware (flat back or angle back type) including cutting for and pinning in ends of brackets or erecting stand etc but excluding fixing of supply and waste pipe complete all as specified and as directed by the Engr-in Charge.
S & F Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed with 15 mm bore pipe complete all as specified and as directed by the Engr-in Charge.
Dismantling water tanks AC/PVC of any type and any position from site of capacity exc 500 litres n.exc 1000 ltrs complete all as specified and directed.
S & F Rotational moulded polyethylene water storage tank 1000ltr (cylindrical vertical with closed top) hoisted and fixed in position all as specified and directed.
S & F in repair provision of Ball PVC valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed in 20 mm dia of the pipe complete all as specified and as directed by the Engr-in Charge.
S & F in repair for vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests (IWC)(excluding flushing cistern and flush pipe) including connection to down or out going pipe and to flushing pipe anti syphonage pipe etc of approved quality complete all as specified and as directed by the Engr-in Charge.
S & F in repair for 10 ltr capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and as directed by the Engr-in Charge.
Supplied only flush pipe of polyethylene of low or high density or PVC 32 mm dia for low level cistern complete all as specified and directed.
S & F for PVC (SWR) 'P’ trap 125/110 mm dia bore complete all as specified and as directed by the Engr-in Charge.
S & F 110 mm PVC (SWR) WC connector with lip ring complete all as specified and as directed by the Engr-in Charge.
S & F for PVC (SWR) bends any radius 110 mm bore with access door complete all as specified and as directed by the Engr-in Charge.
S & F in repair for PVC (SWR) pipes 110 mm dia single socketed, in any length with rubber ring joints, fixed to walls with arrangement complete all as specified and as directed by the Engr-in Charge.
S & F for PVC (SWR) vent cowl 110 mm bore complete all as specified and as directed by the Engr-in Charge.
S & F for PVC (SWR) branch piece, single (single Y) equal or unequal 110 mm bore with access door complete all as specified and as directed by the Engr-in Charge.
S & F in repair for PVC (SWR) pipes 75 mm bore single socketed in any length with rubber ring joints fixed to walls with arrangement complete all as specified and as directed by the Engr-in Charge.
S & F PVC (SWR) bends any radius 75 mm bore with access door complete all as specified and as directed by the Engr-in-Charge.
S & F 75 mm dia of outlet PVC (SWR) floor trap, plain with stainless steel grating including jointing with solvent cement complete all as specified and as directed by the Engr-in Charge.
S & F in repair for stop valve, cast copper alloy, fancy type, chromium plated, screwed down, high pressure, with capstan head handle, screwed both ends for iron pipe or for unions, with long shank and cup (concealed type), bore dia 15 mm complete all as specified and as directed by the Engr-in Charge.
S & F in repair 15mm dia bore chromium plated bib tap long body with capstan head handle with cup, screwed down, screwed for iron pipe or brass ferrule complete all as specified and as directed by the Engr-in Charge.
S & F for PVC connection 15 mm dia with PTMT nuts of length 600 mm long complete all as specified and as directed by the Engr-in Charge.
S & F in repair for 20 mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed approved make complete all as specified and as directed by the Engr-in Charge.
Supply only waste fittings, brass chromium plated, 40 mm dia for SS sink with long screwed shanks and flynuts, waste pipe, flange end bedded in red lead cement and other end fixed complete all as specified and as directed by the Engr-in Charge.
S & F for powder coated anodised aluminium ventilator shutters, fixed type without sash bar including stainless steel wire cloth of 0.63 mm nominal dia and average aperature 1.4 mm, aluminium section weighing not less 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. and fixed to stone masonry wall including demolition of existing RCC jali ventilators complete all as specified and as directed by the Engr-in Charge.
S & F for powder coated aluminium sliding windows having three Nos of tracks including one wire glazed shutters for mosquito proofing including stainless steel wire cloth of 0.63 mm nominal dia and average aperature 1.4 mm and two Nos glass shutters including 4mm thick coloured glass and aluminium section weight n less than 0.55 Kg/Rm including necessary cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, suitable handles, locking arrangement and fixed to stone masonry wall complete all as specified and as directed by the Engr-in Charge.
Taking down Chowkats or frames with shutters without taking of shutters from the frames exc 1.5 Sqm but not exc 4 Sqm each complete all as specified and as directed by the Engr-in Charge.
Taking down Chowkats or frames with shutters without taking of shutters from the frames n. exc 1.5 Sqm each complete all as specified and as directed by the Engr-in Charge.
Taking down shutter exc 1.00 Sqm but n.exc. 2.00 Sqm each and removing from site complete all as directed by Engineer-in-Charge.
S & F factory made shutter 35 m thick, Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and as directed by the Engr-in Charge.
S & F for Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed by the Engr-in Charge.
S & F for Glazed and skeleton shutters 35mm thick (for door) 2nd class hard wood open rebated and prepared to receive glass, gauze etc (without sash bars), edges of framing plain, chamferred or rounded fitted with cut and mitred beads for securing glass etc complete all as specified and as directed by the Engr-in Charge.
S & F PVC door frame of size 50mm x 47mm made out of 5mm thick plain colour PVC sheet reinforced with M S square tube, supply & fixing in opening as per specification and drawing complete all as specified and as directed by the Engr-in Charge.
Factory made solid panel PVC shutter 30 mm thick ( style ) consisting of frame made out of MS tube for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘ C’ channel having a PVC sheet strip 20 mm width struck inside with solvent cement for style and plain colour PVC sheet for top rail lock rail and bottom rail on either side and as gap inserts for top and bottom rail paneling of plain, colour PVC sheet to be fitted in the MS frame welded / sealed to the styles and rail with suitable PVC sheets beading and jointed together with solvent cement S&F in frame at site complete all as specified and as directed.
S & F for Stainless steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18mm and fixed with stainless steel wire staple complete all as specified and as directed by the Engr-in Charge.
M & L for two coats of synthetic enamel paint over a coat of pink primer on new wooden surfaces including all necessary preparation over 10 cms width or girth complete all as specified and as directed by the Engr-in Charge.
S & F 100 mm but hinges, medium weight, stainless steel complete all as specified and as directed by the Engr-in Charge.
S & F for aluminium anodised barrel tower bolt 200mm long complete all as specified and as directed by the Engr-in Charge.
S & F for aluminium handles 150 mm cast type anodised complete all as specified and as directed by the Engr-in Charge.
S & F for stainless steel sliding door bolts, plate type, with stainless steel bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed 300mm long complete all as specified and as directed by the Engr-in Charge.
S&F flat iron 25x3mm thick conforming to Fe-290, Gde E-165 in holdfasts complete all as specified and as directed by the Engr-in Charge.
M & L for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories alongwith one single core green colour PVC insulated 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for one light point or one fan point or one call bell point controlled by one, one way switch including PVC switch board of required size or 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer on existing MS concealled box for mounting of switch, regulators or bell push and casing caping terminal box for mounting ceiling rose/ holders etc incl dismentling taking down old unserviceable point wiring and making good to disturbed surfaces all as specified and directed.
M & L for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories alongwith one single core green colour PVC insulated 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for one 5 amps socket point independent including PVC switch board of required size or 3mm thick hylam sheet screwed with 04 nos screws & cup washer on existing MS concealled box for mounting of switch, socket incl dismentling taking down old unserviceable point wiring and making good to disturbed surfaces all as specified and directed.
M & L for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories alongwith one single core green colour PVC insulated 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for one 5 amps socket point on same board with other switches incl dismentling taking down old unserviceable point wiring and making good to disturbed surfaces all as specified and directed.
M & L for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 2.5 sqmm (Nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 2.5 sqmm as earth lead and connected to earth dolly for one 16amps socket (Power) point independent including PVC switch board of required size or 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer on existing MS concealled box for mounting of switch, socket all as specified and directed.
M & L for surface submain wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn through in and including PVC casing caping/PVC conduit size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly incl dismentling taking down old unserviceable wiring and making good to disturbed surfaces all as specified and directed. NOTE: (a) Two run of cable with one run of earth wire and one run of casing capping/conduit will be measured as one length.
M & L for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including PVC casing caping of required size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for one two way light point controlled by two, two way switch including PVC switch board of required size or 3mm thick hylam sheet screwed with 04 nos screws & cup washer on existing MS concealled box for mounting of switch etc incl dismentling taking down old unserviceable point wiring and making good to disturbed surfaces all as specified and directed.
M & L for surface sub main wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 6.0 sqmm (Nominal area) drawn through in and including PVC casing caping/PVC conduit size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 6.0 sqmm as earth lead and connected to earth dolly incl dismentling taking down old unserviceable wiring and making good to disturbed surfaces all as specified and directed. NOTE: (a)Two run of cable with one run of earth wire and one run of casing capping/conduit will be measured as one length.
S&F 5 Amp switch piano type single pole one way incl dismentling taking down unsv one all as specified and as directed. Make - Anchor
S&F 5 Amp switch piano type single pole two way incl dismentling taking down unsv one all as specified and as directed. Make - Anchor
S&F bell push piano type one way 240 volt incl dismentling taking down unsv one . all as specified and as directed. Make - Anchor
S&F socket flush type 6 amps, 5 pin, 230v incl dismentling taking down unsv one all as specified and as directed.
S&F switch socket combination multipurpose 2-in-1 flush type 3 pin 16 amps and 3 pin 6 amps, 230v incl dismentling taking down unsv one all as specified and as directed. Make - Anchor
S&F lamp Holder insulated body with back plate for batten fitting incl dismentling taking down unsv one all as specified and as directed. Make - Anchor
S&F LED lamp 12 watt, CDL, B-22 cap, (Pin type), 230V, PF-0.95 (min) incl dismentling taking out unsv CFL. Make-HPL/Havells/CG/Bajaj/ Philips.
S&F ceiling rose surface Bakelite three terminal incl dismentling taking down unsv one all as specified and as directed.
S&F call bell electric, ding dong, AC 240 volt, 50 HZ. incl dismentling taking down unsv one all as specified and as directed. Make - Anchor
S&F flush type electronic fan regulator with 5 step type,120 W, AC 240 Volts, 50 Hz incl dismentling taking down unsv one all as specified and as directed.Make - Anchor
S&F MCB, Single Pole, 6 to 32 amps, 240 Volts, 10 KA breaking cap, ‘’C” curve incl dismentling taking down unsv one all as specified and directed. MAKE- Cat Part No- 4085-87 to 4085-95 of Legrand or equivalent of Schneider/ABB.
S&F MCB, Double Pole, 6 to 32 amps, 415 Volts, 10 KA breaking cap, ‘’C” curve incl dismentling taking down unsv one all as specified and directed. MAKE- Cat Part No- 4086-28 to 4086-36 of Legrand or equivalent of Schneider/ABB
S&F MCB distribution board, Double door, metal enclosure, SPN, 230 Volts, 8 way incl dismentling taking down unsv one all as specified and directed. MAKE- Cat Part No- 5076 11 of Legrand or equivalent of Schneider/ABB
S&F LED batten type fitting, 22 watt, CDL, 230 Volts, 4 feet long , complete with all accssories internally pre wired and including connecting up to ceiling rose with 0.5 sqmm twin core copper flexible conductor cable incl LED fitting and mounting casing box 2 nos incl dismentling taking down unsv fitting any type all as specified and directed. Make-HPL, Cat Part No HPLLEDT5PC20W or equivalemt in Bajaj/Philips/CG/Havells
Shri Sant Cosntruction
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .