Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.9 LAccepted-AOC | L1 | Accepted-AOC Lowest bid value | |
| 2 | L2₹35.5 L+₹1.6 L (4.81%)Rejected-AOC | L2 | Rejected-AOC Higher bid value | |
| 3 | L3₹35.7 L+₹1.8 L (5.45%)Rejected-AOC | L3 | Rejected-AOC Higher bid value | |
| 4 | L4₹36.3 L+₹2.4 L (7.23%)Rejected-AOC | L4 | Rejected-AOC Higher bid value | |
| 5 | L5₹36.5 L+₹2.7 L (7.85%)Rejected-AOC | L5 | Rejected-AOC Higher bid value |
Tender Value
₹33.9 L
EMD Value
₹67,800
Closing Date
20 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 868 EWS
GE 868 EWS PIN- 913 868 C/o 99 APO
PROVN OF TROLLY MOUNTED 250 KVA STANDBY DG SET AT RMS
2024_MES_644505_1
8707/C/E8
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
RANGAPAHAR
Class D Category b(i)
2 documents required · 2 mandatory
₹500
GE 868 EWS
₹67,800
30 Mar 2024
28 Feb 2024
22 Mar 2024
28 Feb 2024
20 Mar 2024
12 Mar 2024
28 Feb 2024 - 5 Mar 2024
Amount
Supply, Installing, testing and commissioning sound proof acoustic enclosure diesel engine driven generating set, fully wired 415 volts, +/- 1.5%, 3 phase 4 wire 50 HZ, +/- 0.5% 0.80 PF of capacity 250 KVA, 200 KW having continous rating at 1500 RPM, brushless self excited and minimum of 310 BHP capacity engine turbo charged water cooled complete under NTP condition with provision for 10% overload for 1hr on 12hr running and common base plate frame engine standard instrumental panel, self exciting and self regulating control panel with accessories, self starter 24 volts with battery 180 AH , 24 volts -02 Nos system with battery charging unit SCR type and battery cable leads , exhaust pipe with cladding by asbestos rope, sound proof canopy as per CPCB norms II etc. Diesel engine set as per ISO 8528-1, IS 10000, IS 10001 and alternator as per IS -13364 with inbuilt electronic speed governer with micro processor based control panel with floor mounted fuel tank not less than 12 hours running capacity including necessary anti vibration pads including standard control panel as recommended by the manufacturer .
item 1.00 contd.. (a) (i) Fly wheel to suit coupling (ii) Flexible coupling with guard, bolts and nuts,etc.for exhaust system (iii) Dry type air cleaner filters (iv) Radiator with guard and radiator fan (v) Fuel pump complete with fuel injection systems (vi) Electronic speed governor (vii) Fuel filter (viii) Lub oil filter (ix) Self starter 24 Volts DC (x) Exhaust silencer industrial type with pipe 3 m long (xi) Turbo charger (xii) Lub oil pump (xiii) Lub oil cooler assembly (xiv) Alternator 24 V for charging of battery (xv) One hand rotary type fuel pump connected with heavy duty pipe upto the tank (xvi) Instrumental panel with the following:- (aa) Self starting key and switch (ab) Lubricating oil pressure guage (ac) Battery charging ammeter (ad) Hour meter and RPM indicator (ae) Lub oil temp guage (af) Water temp guage (xvii) Control panel with MCCB as per OEM- 1 No (xviii) Emergency stop push button outside of the container/ Canopy.
item 1.00 contd.. (b) Alternator:- It shall be self excited self generated balanced 415 volts, 3 phase, 50 Cycles per second,250 KVA at 0.8 PF or nearest in higher capacity, 1500 RPM, star connected, 4 wire, drip proof enclosure, air cool with radial fan mounted on rotor, screen protected, self ventilated enclosure as per ISO 8528-1, IS 4722/IS 2613 & IEC 34.10 or latest IS code and with drip proof enclosure with damper winding on pole faces, static automatic voltage regulator to provide voltage regulation +/-1% and harmonic factor better than 2% from no load to full load from 0.8 to unity power factor, efficiency 92% at 100% load/0.8PF, voltage drop at full load ≤ 20% and insulation of H class and above as per standard practice of OEM (c) Starting batteries 24 V, 180 AH maintenance free with suitable size of cable including fitting and terminals on angle iron frame(self starter sytem with 24 volt DC) - 01 No Make Exide/ Amaron/Nicco/ Amco. (d) Fuel tank: Made of 1.6 mm thick CRCA sheet and having continous running of 12 hours at full load with level indicator to indicate the oil level of diesel tank, fuel strainer air vent inlet and out let connections with MS pipe of suitable size complete all as specified and as directed.
item 1.00 contd.. (e) Sheet steel components pre-treated with zinc phosphate prior to polyster powder coating (f) Zinc plated or stainless steel fasteners (g) EPDM quality gasket (xix) Provison of light inside the canopy. (xx) Radiator filling access facility from out side (h) Engine and alternator shall be mounted through AVM Pads on common channel iron base frame. (j) Noise level, less than 75 db (A) at 1 mtr distance controlled by providing specially designed alternator to controlled the sound at air entry and exit of the enclosure.(The make of Acoustic enclosure shall be OEM of DG Set) (Foundation: Cost of PCC foundation as per manufacturer's instructions shall be deemed to be included in the Quoted rate)
M & L for fabrication of DG Set trolley suitable for 250 KVA DG set build with minimum Axle 02 nos, 4 nos wheel (wheel rim, tyre and tube) , shock absorber patti , Hook, 6mm checkered plate, 6 inch channel and accessoreis including panting of trolley etc complete all as specified and as directed.
Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 185 Sqmm 4 core laid in trenches as per IS 7098 (Part I) including connection cable glands, aluminium lugs etc complete all as specified and as directed. Note : Earth work, brick protection and sand cushioning and GI Pipe shall be measured and paid separately under respective item.
Excavation in trenches, n exc 1.5 m wide and depth exc. 1.50 m but n.exc 3.00 m ; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil etc complete all as specified and as directed.
Returning, filling in, of soil including spreading leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed .
Removing exvated material to a distance n.exc 50M and deposited/ spreaded where directed at a level n. exc 1.5 M above the starting point complete all as specified and as directed .
Materials and labour for sand filling around the cable with approved quality coarse sand for sand cushioning of Under ground cable including spreading and punning down to 23cm thickness complete all as specified and as directed.
Materials and labour for brick protection cover to underground cables with sub class ‘B’ over burnt brick of size 23 X 11.5 X 7.5 cm, (locally available best quality), laid dry and flat abutting each other with gaps not exceeding 10mm complete all as specified and as directed.
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron strip 25×4mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25x4mm galvanised iron strip
Rameshwar Prasad
SAYED ALI AND SONS
M/S Lucky Builders
commercial enterprises
VAISHNO ASSOCIATES
M/s K P Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .