Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.2 LAccepted-AOC | ₹31.2 L | L1 | Accepted-AOC Lowest rate tenderer |
| 2 | L2₹33.2 LRejected-AOC CHENNAI | CHENNAI | TAMIL NADU | ₹33.2 L | L2 | Rejected-AOC Highest rate tenderer |
| Sl No | Description | Qty | Unit | BHARATH BUILDING CONSTRUCTION L1 | K.Saravanan L2 |
|---|---|---|---|---|---|
| 1.00 | Supply, installation, testing and commissioning of Micro Processor based Conventional 12 Zone Fire Alarm Control Panel | 1 | 1 No | 86,000 ₹86,000 Lowest | 90,200 ₹90,200 |
| 2.00 | Supply and Installation of Conventional Smoke Detector suitably mounted on ceiling with MS juction box / false ceiling | 120 | 1 No | 2,200 ₹2,64,000 Lowest | 2,600 ₹3,12,000 |
| 3.00 | Supply and Installation of Conventional Multisensor Detector (smoke & Heat) as per standard methods | 5 | 1 No | 1,400 ₹7,000 Lowest | 1,500 ₹7,500 |
| 4.00 | Supply, installation, testing and commissioning of Conventional Manual Pull Station - Single Action. providing on wall | 15 | 1 No | 6,000 ₹90,000 Lowest | 6,200 ₹93,000 |
| 5.00 | Supply, installation, testing and commissioning of Conventional type Horn / Strobe wall mounted type rated at 90 dBA @ 1m for Audible annunciation and 15cd minimum flashing at 1 Hz for visual indication. | 15 | 1 No | 4,000 ₹60,000 Lowest | 4,100 ₹61,500 |
| 6.00 | Supply and laying of FRLS PVC insulated 2 core 1.5 sq.mm. Armoured Copper Cable on ceiling / wall | 2,355 | 1 RMT | 110 ₹2,59,050 Lowest | 118 ₹2,77,890 |
| 7.00 | Supply, installation, testing and commissioning of POWER SUPPLY : 24VDC Power Supply with 5 amp rating, having LED indications for Power supply ON, battery Fail, Battery Charging, battery back up | 5 | 1 No | 10,000 ₹50,000 Lowest | 10,000 ₹50,000 Lowest |
| 8.00 | Supply and fixing of Carbon-di-Oxide Gas Type 2 kg. capacity Fire Extinguisher as per New IS15683, | 7 | 1 No | 8,000 ₹56,000 Lowest | 8,800 ₹61,600 |
| 9.00 | Supply and fixing of stored pressure ABC (Mono Ammonium Phospate) Powder Type Fire Extinguisher of 6 kg. capacity as per IS:15683 with pressure gauge, discharge hose & control nozzle, wall mounting bracket, safety clip | 20 | 1 No | 5,000 ₹1,00,000 Lowest | 5,300 ₹1,06,000 |
| 10.00 | Supply, erection, testing and commissioning of fire fighting application monoblock motor pumpset of 900 LPM at 40 metres head to develop 3.5kg/sq.cm at the heightest and farthest hydrant point to make 30 m water jet at the time of fire fighting emergency circumstances, coupled with 11 KW /15 HP rated three phase 414 volts, 50 Hz, 2880 rpm | 1 | 1 No | 1,52,000 ₹1,52,000 Lowest | 1,55,000 ₹1,55,000 |
Tender Value
Refer Docs
EMD Value
₹26,400
Closing Date
7 Mar 2026, 6:00 pmClosed
Superintending Engineer / CC
No.132, E.V.R.Salai, Kilpauk, Chennai-10
Providing Firefighting and Fire alarm System arrangements for the work of Construction of Cyber Crime Administrative Office Building at PTC Campus, Ashok Nagar in Chennai city
2026_TNPHC_669296_1
SE/CC/DB/241-B/2026
Open Tender
Civil Works
Lump-sum
90 days
PTC Ashok Nagar in Chennai city
Please refer tender documents
7 documents required · 7 mandatory
₹0
₹26,400
15 Mar 2026
2 Mar 2026
9 Mar 2026
2 Mar 2026
7 Mar 2026
2 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, installation, testing and commissioning of Micro Processor based Conventional 12 Zone Fire Alarm Control Panel | 1 | 1 No | - | - |
| 2 | Supply and Installation of Conventional Smoke Detector suitably mounted on ceiling with MS juction box / false ceiling | 120 | 1 No | - | - |
| 3 | Supply and Installation of Conventional Multisensor Detector (smoke & Heat) as per standard methods | 5 | 1 No | - | - |
| 4 | Supply, installation, testing and commissioning of Conventional Manual Pull Station - Single Action. providing on wall | 15 | 1 No | - | - |
| 5 | Supply, installation, testing and commissioning of Conventional type Horn / Strobe wall mounted type rated at 90 dBA @ 1m for Audible annunciation and 15cd minimum flashing at 1 Hz for visual indication. | 15 | 1 No | - | - |
| 6 | Supply and laying of FRLS PVC insulated 2 core 1.5 sq.mm. Armoured Copper Cable on ceiling / wall | 2,355 | 1 RMT | - | - |
| 7 | Supply, installation, testing and commissioning of POWER SUPPLY : 24VDC Power Supply with 5 amp rating, having LED indications for Power supply ON, battery Fail, Battery Charging, battery back up | 5 | 1 No | - | - |
| 8 | Supply and fixing of Carbon-di-Oxide Gas Type 2 kg. capacity Fire Extinguisher as per New IS15683, | 7 | 1 No | - | - |
| 9 | Supply and fixing of stored pressure ABC (Mono Ammonium Phospate) Powder Type Fire Extinguisher of 6 kg. capacity as per IS:15683 with pressure gauge, discharge hose & control nozzle, wall mounting bracket, safety clip | 20 | 1 No | - | - |
| 10 | Supply, erection, testing and commissioning of fire fighting application monoblock motor pumpset of 900 LPM at 40 metres head to develop 3.5kg/sq.cm at the heightest and farthest hydrant point to make 30 m water jet at the time of fire fighting emergency circumstances, coupled with 11 KW /15 HP rated three phase 414 volts, 50 Hz, 2880 rpm | 1 | 1 No | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_804208.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.63 MB
TenderdocumentsatFirefighting.pdf
Tender Documents • 4.76 MB
BOQ_804208.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].