Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAdmitted-Finance | ₹1.2 Cr | L1 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/s Maharashtra Agencies L1 |
|---|---|---|---|---|
| 1.00Removing, dismantling, re errecting 900 HP V T pumps for overhauling and replacement of spare part for two numbers of pumps out of four numbers pumps at Yeldari pump house | ||||
| 1.10 | Flex coupling pump half + motor half | 1 | Nos | 86,718 ₹86,718 Lowest |
| 1.20 | Fasterners below water level | 1 | Nos | 4,03,319 ₹4,03,319 Lowest |
| 1.30 | O ring Stuffing box | 1 | Nos | 1,303 ₹1,303 Lowest |
| 1.40 | O ring RM pipes | 1 | Nos | 2,827 ₹2,827 Lowest |
| 1.50 | O ring casing & suction bell mouth | 1 | Nos | 2,827 ₹2,827 Lowest |
| 1.60 | Thrust block key | 1 | Nos | 1,295 ₹1,295 Lowest |
| 1.70 | Key (Solid muff coupling) | 1 | Nos | 3,240 ₹3,240 Lowest |
| 1.80 | Coupling key | 1 | Nos | 2,275 ₹2,275 Lowest |
| 1.90 | Key (Impeller) | 1 | Nos | 3,220 ₹3,220 Lowest |
Tender Value
₹2.3 Cr
EMD Value
₹2.3 L
Closing Date
26 Mar 2025, 12:00 pmClosed
COMMISSIONER, PCMC, PARBHANI
COMMISSIONER, PCMC, PARBHANI
Operation and maintanance and repairs of raw water pumping stations 900 hp vt pumps and alied equipments at yeldari, 335 hp at dharmapuri. day to day o and m at shivneri pumping station
2025_PCMC_1153876_3
6946/2024-25
Open Tender
Civil Works - Water Works
Item Wise
1095 days
PCMC PARBHANI
Please refer Tender documents.
5 documents required · 5 mandatory
₹10,000
₹2.3 L
9 Jul 2025
19 Mar 2025
27 Mar 2025
19 Mar 2025
26 Mar 2025
19 Mar 2025
Amount
Removing, dismantling, re errecting 900 HP V T pumps for overhauling and replacement of spare part for two numbers of pumps out of four numbers pumps at Yeldari pump house
Flex coupling pump half + motor half
Fasterners below water level
O ring Stuffing box
O ring RM pipes
O ring casing & suction bell mouth
Thrust block key
Key (Solid muff coupling)
Coupling key
Key (Impeller)
Thrust brg lock nut
Internal bearing sleeve
Pump bearing sleeve
Pump bearing bush
Internal bearing bush
Logging ring
Gland sleeve
Solid Muff Coupling
Split collar
Int. shaft SS410 with duly fitted SS410 Int. brg. Sleeve
Top shaft SS410 with duly fitted SS410 gland sleeve
Impeller wear ring DE & NDE
Suction Strainer
Oil level indicator
Sph. Roller thrust bearing
Gland packing
Gland (Split)
Combined sleeve & nut
Ratchet bush
Ratchet mounting plate
Removing, dismantling, Rewinding, re errecting & to and fro transportation of 900 HP motor No. 2 , one number motor out of four numbers of Motors of Yeldari pump house etc complete
Repairing of L.T. Panel including replacing spare part & internal cabling for making tripping perfect etc complete at Yeldari Pump house.
Rewinding of power transformer including dismantling, Rewinding with new insulated copper wire/strips of proper size, varnishing/ backing and filling with fresh transformer oil, painting assembly and testing of works and repairing of OLTC unit also and delivery at site. ( 2000 kVA, 33/3.3 kVA) replacing with new rediators with to & fro transportation charges with loading, unloading etc complete
Rewinding of power transformer including dismantling, Rewinding with new insulated copper wire/strips of proper size, varnishing/ backing and filling with fresh transformer oil, painting assembly and testing of works and repairing of OLTC unit also and delivery at site. ( 100 kVA, 33/415 kVA) with to & fro transportation charges with loading, unloading etc complete
Repairing & replacing with required spare part of ABB Vaccu Circuit breaker Total 8 Nos(Motor feeder VCB 5 Nos + incomer VCB 2 Nos & Bus coupler VCB 1 Nos + Outdoor VCB 3 Nos) at yeldari pump house
Repairing of all H.T. Panels including replacing of spare part and relays & internal cabling for making tripping system perfect during break down of 33 V Power supply etc complete with full system testing at Yeldari Pump House
Supplying and erecting Aluminium conductor, XLPE/ PVC - 3.3 kV, armoured cable complete erected in provided trench or on provided trays in an approved manner as per direction of Engineer In Charge at yeldari pump house from HT transformer to incomer pannel, total length 170 Rmt each for 2 nos . HT transformer. (Rate SSR 2022 - 23, Page No. 25, I. No. Sec 13 CB 9-11 ) 3 Core 400 sq mm
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required at Yeldari Pump House. As per specification no EA-EP. (Rate PWD ( Electrical ) SSR 2022 - 23, Page No. 160, I. No. Chapter 9, 9-2-3 )
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials, testing & recording the results as per specification no. EA-EP at Yeldari Pump House. (Rate PWD ( Electrical ) SSR 2022 - 23, Page No. 160, I. No. Chapter 9, 9-1-3 )
Removing, dismantling, re errecting 335 HP V T pumps for overhauling and replacement of spare part for two numbers of pumps out of Five numbers at Dharmapuri pump house. The details are as under
O ring Stuffing box
O ring RM pipes
Thrust block key
Key (Solid muff coupling)
Coupling key
Thrust bearing lock nut
Internal bearing sleeve
Pump bearing sleeve
Pump bearing bush
Internol bearing bush
Logging ring
Gland sleeve
Split collar
Int. shaft SS410 with duly fitted SS410 Int. brg. Sleeve (Length as per side condition)
Impeller wear ring DE & NDE
Oil level indicator
Sph. Roller thrust bearing
Gland packing
Gland (Split)
Combined sleeve & nut
Ratchet bush
Ratchet mounting plate
Removing, dismantling, Rewinding, re errecting & to and fro transportation of 335 HP any two number motor out of five numbers of Motors of Dharmapuri pump house etc complete
Repairing of L.T. Panel including replacing spare part & internal cabling for making tripping perfect etc complete at Dharmapuri Pump house.
Rewinding of power transformer including dismantling, Rewinding with new insulated copper wire/strips of proper size, varnishing/ backing and filling with fresh transformer oil, painting assembly and testing of works and repairing of OLTC unit also and delivery at site. ( 1200 kVA, 33/3.3 kVA) replacing with new rediators with to & fro transportation charges with loading, unloading etc complete
Reparing and realignment of 33 KV isolator at trasnformer sub station to control 33 KC power supply during break downs etc
Repairing & replacing with required spare part of ABB Vaccu Circuit breaker Total 8 Nos(Motor feeder VCB 5 Nos + incomer VCB 2 Nos & Bus coupler VCB 1 Nos) at Dharmapuri pump house
Repairing of all H.T. Panels including replacing of spare part and relays & internal cabling for making tripping system perfect during break down of 33 V Power supply etc complete with full system testing at Dharmapuri Pump House
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required at Yeldari Pump House. As per specification no EA-EP. (Rate PWD ( Electrical ) SSR 2022 - 23, Page No. 160, I. No. Chapter 9, 9-2-3 )
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials, testing & recording the results as per specification no. EA-EP at Yeldari Pump House. (Rate PWD ( Electrical ) SSR 2022 - 23, Page No. 160, I. No. Chapter 9, 9-1-3 )
at shivneri nagar pump house
Removing, Rewanding, trasportation and reinstaling & testing of 20 HP submersible pumps & Motors of Shivnery Pump house with required material
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.78 MB
notice.pdf
Tender Documents • 0.66 MB
BOQ_2020832.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .