Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.0 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹35.9 L+₹3.9 L (12.1%)Rejected-Finance NEW ABADI KISHANPURA SURATGARH 335804 DISTT SRIGANGANGAR RAJ | GANGANAGAR | RAJASTHAN | 335804 | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹36.0 L+₹4.0 L (12.4%)Rejected-Finance | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹36.6 L+₹4.5 L (14.2%)Rejected-Finance | L4 | Rejected-Finance Not lowest bidder | |
| 5 | L5₹36.7 L+₹4.7 L (14.7%)Rejected-Finance NURSERY SCHOOL 1 SECTOR 33 SUNCITY KURUKSHETRA ROAD KAITHAL 136027 HARYANA | KAITHAL | KAITHAL | HARYANA | 136027 | L5 | Rejected-Finance Not lowest bidder |
Tender Value
Refer Docs
EMD Value
₹92,000
Closing Date
15 Mar 2021, 6:00 pmClosed
GE ARMY SURATGARH
SURATGARH MIL STN
Provn of guard room, A Veh shed, toilet, AC system with false ceiling and other sanctioned works under AGE B/R-II at Suratgarh Mil Stn
2021_MES_423063_1
GE (A) SOG - 73/20-21
Open Tender
Civil Works
Item Rate
270 days
SURATGARH
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE ARMY SURATGARH
₹92,000
Yes
20 Mar 2021
17 Feb 2021
17 Mar 2021
17 Feb 2021
15 Mar 2021
1 Mar 2021
Amount
Taking down cement plaster or cement lime plaster on PCC/stone surface/brick surfaces of walls including raking out joints hacking for key scrubbing down with water etc complete all as specified and directed by Engineer-in-charge.
Excavation over areas not exc 1.5m deep and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-charge.
Excavating in post holes (or similar holes) each not exc 0.50 cum in soft / loose soil, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n.exc 25cm, watering, and removing surplus soil to a distance n.exc 50 m and making good surface complete all as specified and directed by Engineer-in-charge.
Excavation in trenches, not exc 1.5 m wide and n. exc 1.5 m depth, or n exc 10 Sqm on plan and n exc 1.5 m in depth for foundations of poles, struts, stays etc. or laying underground cable and water supply / sewage pipe line etc. in soft / loose soil & getting out including taking out old brick or precast cable cover complete all as specified and directed by Engineer-in-Charge.
All as per serial item No. 4 here-in-above but depth exc 1.5 mtr & not exc 3mtr
Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified and directed by Engineer-in-charge.
Removal of excavated soil/ material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and directed by Engineer-in-charge.
Removal of excavated soil/ material to a distance exc 250 metre and not exc 500 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and directed by Engineer-in-charge.
Surface excavation not exceeding 30 cm deep and averaging 15cm deep in soft/ loose soil and getting out complete all as specified and directed by Engineer-in-Charge.
M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed by Engineer-in-Charge.
M&L for Shingle filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled, and blinded with earth and rammed including watering complete all as specified and directed by Engineer-in-Charge.
M&L Moorum/red bajri filling in floors or pavings, laid in layers not exc 15 cm thick spread, levelled and rammed including watering complete all as specified.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement including forms, moulds, mitred/stopped ends etc. complete all as specified and directed by Engineer-in-charge.
Supply only integral water proofing compound (ISI marked) complete all as specified and directed by Engineer-in-charge.
M&L for hardcore of broken stone / boulders gauge not exc. 63mm, deposited, spread and leveled in layers not exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed by Engineer-in-charge.
M&L for hard core of broken bricks aggregate of gauge exceeding 63mm but n. exc 100mm, deposited, spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface complete all as specified and directed by Engineer-in-Charge.
M&L anti-termite treatment to the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the substructure in contact with backfill to be measured) complete all as specified & as directed.
M&L anti-termite treatment to the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified & as directed.
M&L anti-termite treatment to the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified & as directed.
M&L anti-termite treatment to the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified & as directed.
M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation, filling & mass concrete complete all as specified and directed by Engineer-in-charge .
M & L for PCC (1:3:6) typeC-2 using 40mm graded stone aggregate as in foundation for stays & mass concrete including necessary form work and fair finishing complete all as specified and directed by Engineer-in-charge
M&L PCC (1:3:6), type C-2 using 40 mm graded stone aggregate as in surface channels and drains complete all as specified and as directed by Engineer-in-charge.
M&L for cement concrete (1:2:4) type B1 using 20 mm graded crushed stone aggregate as in surface channels and drains and benching including finishing the top of benching even and smooth using extra cement complete all as specified and directed by Engineer-in-charge. Note : Forming fair finished channel for drain using extra cement shall be measured and paid for separately.
M&L precast cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) in window or door cills, lintels, brssumers, steps, quoin blocks (for use with masonary), string courses, copings, kneelers, apex stones, kerb stone, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, anchorage blocks and simillar articles with plain faces, corbels, brackets, etc (of any section indicated), with plain fair faces, including chamfers, weatherings, throating etc and set in cement mortar (1:4) complete all as specified and directed by Engineer-in-Charge.
M&L for cement concrete 1:2:4, type B-1 (using 20mm graded stone aggregate) as in lintels upto 1.5 metre clear span, cills, steps, siesmic and other similar bands, plinth courses, string courses, lacing courses, coping, parapets and railing upto 60cm height, copings bed block,roof kerbs or mud stops, kerb stone, kneelers, apex stones, bed plates, surface channels and drains, benching, water troughs and the like including weathering, slightly rounded or chamfered angles and throatings etc.including necessary form work complete all as specified and directed by Engineer-in-Charge.
M&L for PCC (1:2:4) type B1, using 20mm graded stone aggregate as in coping, benching and bed blocks etc including weathering, slightly rounded, chamfered angle and throating as directed including use and waste of form work (straight or curved) all exposed surface of concrete finished even and fair complete all as specified and directed by Engineer-in-charge.
M & L for plain cement concrete (1:3:6) type C-1 using 12.5mm graded stone aggregate as in filling of pressed steel frame, hold fast blocks and other similar items etc complete all as specified and directed by Engineer-in-Charge.
M&L for pre-cast RCC (1:2:4) type B-1 using 20mm graded stone aggregate as in landing, cover slab for manholes, septic tanks, soakage wells, chullah hood, chajjas, water troughs, mangers, shelves and similar articles with plain fair faces including chamferred, weatherings, throating etc including necessary form work complete all as specified and directed by Engineer-in-Charge Note: - Reinforcement shall be measured and paid for separately.
M&L for reinforced cement concrete M-25 design mix, using 20mm graded stone aggregate for slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and other similar works complete all as specified and directed and directed by Engineer-in-Charge.
M&L for reinforced cement concrete (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) for slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and other similar works complete all as specified and directed and directed by Engineer-in-Charge.
M&L for reinforced cement concrete M-25 design mix using 20 mm graded crushed stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc ; basement slabs, under- reamed piles and mass concrete complete all as specified and directed by Engineer-in -charge.
M&L for reinforced cement concrete M-25 design mix (using 20 mm graded crushed stone aggregate) as in beams , cantilever, bressummer, lintel over 1.5m span and similar work complete all as specified and directed by Engineer-in-Charge
M&L for reinforced cement concrete (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) nominal mix as in beams , cantilever, bressummer, lintel over 1.5m span and similar work complete all as specified and directed by Engineer-in-Charge
M&L for providing Reinforced cement concrete (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) nominal mix as in chajjas and the like complete all as specified and directed by Engineer-in-Charge.
M&L for providing reinforced cement concrete M-25 design mix, using 20mm graded stone aggregate as in chajjas and the like complete all as specified and directed by Engineer-in-Charge.
M&L for providing reinforced cement concrete M-25 design mix, using 20mm graded stone aggregate as in column, pillars, piers, posts and sturts complete all as specified and directed by Engineer-in-Charge.
M&L for Brick work with sub class ‘B’ old size burnt bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed by Engineer-in-charge.
M&L for Brick work with sub class ‘B’ old size burnt bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:4) complete all as specified and directed by Engineer-in-charge.
M&L for brick work built in CM (1:4) using sub class 'B' bricks, straight or curved on plan to any radius in half brick thick walls complete all as specified and directed by Engineer-in-charge.
M&L for 40mm thick damp proof course to horizontal or vertical surfaces in PCC (1:2:4) type B0 using water proofing compound including necessary form work complete all as specified & directed by Engineer-in-Charge. Note : - Supply only water proofing compound shall be measured and paid for separately
M&L for continuous brick edging (sub class ‘B’) with width equal to the length of brick laid dry on edge vertically including necessary earth work, embedding bricks at depth as indicated and temping around bricks and removal of surplus soil to a distance not exceeding 50 metre and depositing where directed complete all as specified and directed by Engineer-in-Charge. Note : Each row shall be measured and paid separately.
M&L for use and waste of form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work, vertical or to batter for rough finished surfaces of concrete flat complete all as specified and directed.
M&L for use and waste of form work to soffits of suspended slab such as roof slab, floor slab, landing and similar work exceeding 200mm thick (horizontal or sloping), rough finished surface of concrete complete all as specified and directed by Engineer-in-Charge.
M&L for use and waste of form work to flat surfaces of chajjas, chullah hoods, troughs and similar items including edges for rough finished surfaces complete all as specified and as directed by Engineer-in-charge.
M&L for use and waste of form work to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for rough finished flat surfaces of concrete complete all as specified and as directed by Engineer-in-charge.
M&L for Square, Circular rectangular on plan or polygonal use and waste of form work to sides pillars, posts, struts, pier, columns and stanchions for rough finished surfaces of concrete complete all as specified and directed.
M & L for Use and waste of form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls , horizontal or sloping and similar work exceeding 10cm wide but not exceeding 20cm wide, surface flat for rough finished surface of concrete complete all as specified and directed by Engineer-in-Charge.
M&L for 30mm thick flush shutter solid core construction with block board core & ply wood face panels, commercial type on both faces complete all as specified and directed by Engineer-in-charge.
S&F 35mm thick factory made glazed and skeleton shutters made of second class hard wood (Bonsum/Hollock), open rebated and prepared to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc., sizes of members of shutters as specified in SSR Part I Section 8 Clause 8.24 (a) kiln seasoned and chemically pressure treated fixed to chowkat complete all as specified and directed by Engineer-in-charge.
S&F factory made solid PVC door frame of size 50mm x 47mm made out of 5mm thick plain colour PVC sheet reinforced with MS square tube complete all as specified & shown in relevant drawing of item No. 08095 in MES Schedule (Part-II) and directed by Engineer-in-Charge
S&F 28 to 30mm thick (stiles) factory made solid PVC moulded Door shutter, with 2, 4, or 6 raised panel design with 2mm thick moulded prelaminated PVC sheet on the front face & 2mm thick prelaminated PVC sheet on back face complete all as specified & shown in relevant drawing of item No. 8101 to 8105 in MES Schedule (Part-II) and directed by Engineer-in-Charge.
S&F 30mm thick factory made solid core PVC door shutter (style) consisting of frame made out of mild steel tubes for top and bottom rails, mild steel frame shall be covered with heat moulded plain colour PVC sheet, 'C' channel having PVC sheet strip of 20mm width stuck inside with solvent cement for styles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail and bottom rail; panelling of plain colour PVC sheet to be fitted in mild steel frame welded/ sealed to the styles and rails with suitable PVC sheet beading and joined together with solvent cement, complete, all as specified & shown in relevant drawing of item No. 08080 in MES Schedule (Part-II) and directed by Engineer-in-Charge.
S&F 200 mm long aluminium anodized barrel tower bolts of extruded section complete all as specified and directed by Engineer-in-charge.
S&F 150 mm long aluminium anodized barrel tower bolts of extruded section complete all as specified and directed by Engineer-in-charge.
S&F 100mm size mild steel butt hinges cold rolled medium weight complete all as specified & directed by Engineer-in-Charge.
S&F 125mm size mild steel butt hinges cold rolled medium weight complete all as specified & directed by Engineer-in-Charge.
S&F 100mm size butt hinges of extruded aluminium alloy with galvanized mild steel hinge pin, anodized type B-21 complete all as specified and directed by Engineer-in-charge.
S&F 250mm long aluminium alloy anodised sliding door bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified & directed by Engineer-in-Charge.
S&F 300mm long aluminium alloy anodised sliding door bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified & directed by Engineer-in-Charge.
S&F 150mm long extruded aluminium handles, anodised, fabricated type complete all as specified and directed by Engineer-in-Charge
S&F floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring overall length of cover plate 140mm complete all as specified and directed by Engineer-in-Charge.
S&F galvanized mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanized wire staple complete all as specified and directed by Engineer-in-charge.
S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or stainless steel wire staples complete all as specified and directed by Engineer-in-Charge.
S&F powder coated mild steel drapery rod of 20 mm inner dia (in lengths as directed) of approved colour with & including decorative finial at both ends and pair of powder coated mild steel brackets fixed at both ends with PVC rawl plug & steel screws on walls/beam, including PVC curtain rings of matching colour @ 10cm C/C all as specified & as directed.
S&F mild steel work as in hold fast, wind tie for roof covering including securing bolts necessary drilling bolts or reiveting conforrming to Fe-290 (Gde E-165) complete all as specified and directed by Engineer-in-Charge
M&L for mild steel pipes as in Hand rails,half round,nosing to steps including embedding in concrete securing bolts,posts and struts in fencing incld drilling bolting or riveting etc. wind tie for roof including cutting topes to shape as directed, drilling holes, notching for wire etc, flat iron (for securing wire mesh) conforming to Fe-290 Gde E-165, complete all as specified and directed by Engineer-in-Charge.
S&F mild steel TMT bars 6 to 8 mm dia and over cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed by Engineer-in-charge.
S&F mild steel TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed by Engineer-in-charge.
All as per serial item No 69 here-in-before but 5mm dia and over up to and including 10mm dia as in stirrups, spacers & binder etc.
S&F mild steel round bars as in window guard bars incl necessary welding and a shop coat of zinc primer confirming to Fe-290 (Gde-E-165) complete all as specified and directed by Engineer-in-Charge.
S&F mild steel framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, cooler stand, framework of water tanks and similar works of quality Fe 290 (Gde E-165) etc complete all as specified and directed by Engineer-in-charge.
M&L for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed by Engineer-in-charge.
S&F factory made steel window with side hung shutters including box type hinges with steel handle, steel peg stay, fixing lugs etc complete with glazing bars including one shop coat of red oxide primer and Cutting holes in brick wall built in cement mortar for inserting lugs and making good dismantled portion in cement mortor (1:3) or cement concrete (1:2:4) type B-I complete all as specified & directed by Engineer-in- charge
S&F factory made steel ventilator with top hung shutter including hinges, steel peg stay, handle including one shop coat of Zinc Chromate primer and cutting holes in brick wall built in cement mortar for inserting lugs and making good dismantled portion in cement mortor (1:3) or cement concrete (1:2:4) type B-I complete all as specified and directed by Engineer-in-charge.
S&F pressed steel frames for door of size 125x60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and as directed by Engineer-in-charge.
S&F pressed steel frames for door of size 105x60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and as directed by Engineer-in-charge.
M & L for Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-charge.
S&F Anodised aluminium snap grid frame work of size 605mm x 605mm for false ceiling including necessary notching. The snap grid shall consist of anodized aluminium main & cross Tee of size 36.5mm x 25mm x 1.4mm weighing 0.24 Kg/RM and 23.5mm x 26.4mm x1.40mm weighing 0.191Kg/RM respectively. The main and cross tee shall be jointed at junction crossing with anodized aluminium angle bracket of size 15mm x 15mm x 1.5mm weighing 0.12Kg /RM fixed with suitable MS bolts, nuts and washer. The snap grid (main /cross tee section) shall be supported at ends all along the wall with anodized aluminium angle of size 35mm x 25mm x 2mm weighing 0.36 Kg/RM fixed to wall with suitable arrangement duly suspended with 3mm dia GI wire length as required @ 600mm C/C with adjustable device including plugging in brick / concrete work with steel raw plugs including making good all the disturebed portion complete all as specified and directed by Engineer-in-Charge.
M&L for gypsum board false ceiling 12mm thick with perimetre channel 20x28x30mm and intermediate channel 15x45x0.90mm @ 457mm c/c with screws and taping screws having philips head with under head cutter at 200mm centre to centre including finishing the joints of face boards with specially formulated jointing compound and 48mm wide fibre tape to provide seam less finish, suspended with 6mm dia GI adjustable hanger @ 1200mm c/c fixed to roof with rawl plugs for adjusting level complete all as specified and directed by Engineer-in-Charge.
M&L for machine cut Kota stone slab flooring 18 to 20mm thick (minimum size 550mm x 550mm or size as directed) laid over & including screed bed or bedding layer of 15mm thick in CM (1:6) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and directed by Engineer-in-charge.
M&L for machine cut Kota stone slab 18 to 20mm thick (minimum size 550mm x 100mm or size as directed), on vertical surfaces such as dado, skirting, raiser of steps etc. laid over & including rendering 10mm thick in CM (1:4) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including cutting, grinding, rubbing and mirror polishing complete all as specified and directed by Engineer-in-charge.
M&L for cleaning of all loose dirt and dust from roof and priming the surface with one coat of cold applied bituminious primer @ 0.40 Kg/Sqm conforming to IS:3384 and applying a layer of APP based polymeric membrane not less than 3 mm thick, weighing not less than 3.5 Kg/Sqm, reinforced with polyester non woven fabric (weighing not less than 150 gms/Sqm) and upper side of membrane thermally insulated with white gravel finish uniformaly embedded during manufacturing process. It shall be laid by torch application having side over lap 75 mm and at the end 100 mm, all overlaps and joints shall be sealed by torch application. For parapet, membrane shall be taken to a height of minimum 60 cm and inserted inside the parapet in a groove to a depth of 65mm. The same shall be furnished by a membrane flashing. Note : The net area of water proofing treatment shall be measured without any extra allowance for laps & portion inserted in groove which shall be deemed included in the quoted rates.
M&L for 25mm thick PCC (1:2:4) type B1 using 20mm graded stone aggregate as in roof and laying 5mm screed bed of cement mortar (1:4) with water proofing compound, finished even and smooth without using extra cement cement complete all as specified and as directed by Engineer-in-charge.
M&L for applying evenly one coat of industrial bitumen 85/25 @ 1.20 Kg per Sqm including cleaning of surface complete all as specified and directed by Engineer-in-Charge.
M&L for wire brushing and cleaning concrete surface on top of roof providing 20mm thick screed in cement mortar (1:4) over and including applying evenly a tack coat of bitumen 85/25 @ 1.20 KG/Sqm over and including 80mm thick average consolidated thickness mud phuska including 25mm thick mud plaster on flat roofs complete all as specified and directed by Engineer-in-charge.
M&L for 40mm thick brick tiles laid on mud mortar and joints grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement on mud phuska complete all as specified and directed by Engineer-in-charge.
M&L for 40mm thick brick tiles laid on and joints grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement complete all as specified and directed by Engineer-in-charge.
M&L for 18-20mm thick Granite (of any type) slab of approved shade as in cooking platforms, steps, jambs, pillars, window cills and the like etc, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match with shade of Granite stone including cutting, grinding and polishing (mirror polish i.e. full granite polish as per local trade practice) over & including 15mm thick screed bed (bedding layer) in CM (1:6) complete all as specified and directed by Engineer-in-charge.
M&L for 50 mm thick PCC (1:3:6) type C1 using 20 mm graded crushed stone aggregate as in plinth protection, finished fair and even complete all as specified and directed by Engineer-in-charge. Note :- Plinth protection shall be laid to slope (1 in 30) in bays not exceeding 3 metre in length and joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with sealing compound grade B. Cost of ceiling compund is included in the unit rate of this item
M&L for 75 mm thick PCC (1:3:6) type C-2 using 40 mm graded crushed stone aggregate as in plinth protection, finished fair and even complete all as specified and directed by Engineer-in-charge. Note :- Plinth protection shall be laid to slope (1 in 30) in bays not exceeding 3 metre in length and joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with sealing compound grade B. Cost of ceiling compund is included in the unit rate of this item
M&L for 75 mm thick PCC (1:4:8) type D-2 using 40 mm graded crushed stone aggregate as in sub base, finished fair and even complete all as specified and directed by Engineer-in-charge.
M&L for 100 mm thick PCC (1:4:8) type D-2 using 40 mm graded crushed stone aggregate as in sub base, finished fair and even complete all as specified and directed by Engineer-in-charge.
M&L for 100mm thick plain cement concrete (1:2:4) type B-2 using 40mm graded stone aggregate as in floors finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for non skid joint free ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar (1:6) complete all as specified and directed by Engineer-in-charge.
M&L for non skid joint free ceramic white coloured tiles 7 to 8mm thick (square / rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar (1:6) complete all as specified and directed by Engineer-in-charge.
M&L for glazed ceramic tiles (coloured) 350mm x 250mm x 7mm or 450mm x 350mm x 7mm thick on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10mm thick rendering in cement & sand mortar (1:4) including necesary cutting as per site requirment complete all as specified and directed by Engineer-in-charge.
M&L for 10mm thick vitrified ceramic dark shade, double charge (as approved) coloured tiles (square / rectangular), polished, area of each tile exceeding 0.42 sqm but not exceeding 1.00 sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar (1:6) complete all as specified and directed by Engineer-in-charge.
M&L for 10mm thick vitrified ceramic dark shade, double charge (as approved) coloured tiles (square / rectangular), polished, area of each tile exceeding 0.42 sqm but not exceeding 1.00 sqm as on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10mm thick rendering in cement & sand mortar (1:4) complete all as specified and directed by Engineer-in-charge.
S&F factory casted 100mm thick precast concrete interlocking paving blocks M-50 having compressive strength not less than 400 Kg / Sqcm using grey cement and with pigment and of shape hexagon/ triangular / zigzag / I-shaped / Three-X etc as directed conforming to IS 15658-2006, laid dry over and including 25mm thick layer of local tibba sand cushining over complete all as specified and directed by Engineer-in-Charge.
S&F factory casted 60mm thick machine pressed cement concrete interlocking paving blocks M-35 having compressive strength not less than 350 Kg / Sqcm using grey cement and no pigment and of shape hexagon/ triangular / zigzag / I-shaped / Three-X etc as directed conforming to IS 15658-2006, laid over & including 25mm thick sand cushion (local tibba sand), laid dry, joint filled with dry sand complete all as specified and directed by Engineer-in-Charge.
M&L for 15mm thick rendering in two layer on stone masonry surfaces or surfaces other than fair face of brick work of walls consisting of 1st layer of 10mm thick plaster in CM 1:6 and 2nd layer (setting coat or top layer) of 5 mm thick plaster in CM 1:4 mixed with water proofing compound (ISI marked) @ 3% by weight of cement or as per manufacturer’s instructions, finished fair & even, complete, all as specified and directed. Note : - Supply only water proofing compound shall be measured and paid for separately.
M&L for 15mm thick rendering in cement mortar (1:4) on brick walls/concrete surfaces mixed with water proofing compound as per manufacturer’s instructions including finishing the surfaces even and smooth without using extra cement complete all as specified and directed by Engineer-in-charge. Note : - Supply only water proofing compound shall be measured and paid for separately under respective item of BOQ.
M&L for 15mm thick rendering in cement mortar (1:4) on fair faced or on other than fair face surface of brick masonary or concrete surface of walls, finished even & smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L for 15mm thick rendering in cement mortar (1:6) on fair faced or on other than fair face surface of brick masonary or concrete surface of walls, finished even & smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L for 10mm thick rendering in cement mortar (1:3) on brick or concrete surface of ceiling, finished even & smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
Raking out joints/pointing to brick work in walls or to bricks tiles laid flat in floors, surface channels, roofs, etc and M&L for flush pointing to brick laid flat or brick tiles in roofs in cement mortar (1:3) mixed with 5% crude oil by weight of cement in patches complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of newly plastered surfaces of wall and applying three coats of white wash complete all as specified and directed by Engineer-in-charge.
M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed by Engineer-in-charge.
M&L for preparation of newly plastered surface of walls & applying two coats of cement base paint of approved shade/tint complete all as specified and directed by Engineer-in-charge.
M&L for preparation of new plastered and unplastered surfaces of wall and applying two coats of distemper oil bound including chalk whitening preparatory to distempering complete all as specified & directed by Engineer-in-Charge.
M&L for preparation of new plastered and unplastered surfaces of wall and applying two coats of plastic oil emulsion including chalk whitening preparatory to distempering complete all as specified & directed by Engineer-in-Charge.
M&L for preparation of new plastered and unplastered surfaces of wall and applying two coats of distemper oil emulsion over a coat of appropirate primer over and including 3mm thick layer of wall putty (Make J K or Birla) complete all as specified & directed by Engineer-in-Charge.
M&L for preparation of new wooden or wood based surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-charge.
S&F 3mm thick sheet glass ordinary quality and glazing with oil putty in square not exc 0.5 sqm in each pane complete all as specified and directed by Engineer-in-charge.
S&F 4mm thick figured glass pin head type and glazing with oil putty in square not exc 0.5 sqm in each pane complete all as specified and directed by Engineer-in-charge.
S&F 3mm thick obscured or frosted glass pin head type and glazing with oil putty in square exc 0.5 sqm in each pane complete all as specified and directed by Engineer-in-charge.
S&F 15mm bore galvanized steel water tubing medium grade with & including all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engineer-in-charge.
S&F 20 mm bore galvanized steel water tubing medium grade with & including all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engineer-in-charge.
S&F 25mm bore galvanized steel water tubing medium grade with & including all fittings and fixed complete to walls and ceilings or laid in floors / trenches / sunken complete all as specified and directed by Engineer-in-charge.
S&F 25mm bore galvanized steel water tubing medium grade with & including all fittings, laid in trenches complete all as specified and directed by Engineer-in-charge. Note :- Excavation and earthwork shall be measured and paid for separately under respective items of BOQ.
S&F 40mm bore galvanized steel water tubing medium grade with & including all fittings, laid in trenches complete all as specified and directed by Engineer-in-charge. Note :- Excavation and earthwork shall be measured and paid for separately under respective items of BOQ.
M&L cutting existing GI water main pipe line in position of 50mm bore and making connection of new pipe line of 40mm bore with & including new GI Tee of size 80mm x 80mm x 50mm and its insertion including excavation & earth work in any type of soil complete all as directed.
S&F gun metal globe or gate valve 20mm bore with iron wheel head, screwed both ends for iron pipes complete all as specified and directed by Engineer-in-charge.
S&F gun metal globe or gate valve 25mm bore with iron wheel head, screwed both ends for iron pipes complete all as specified and directed by Engineer-in-charge.
S&F gun metal globe or gate valve 40mm bore with iron wheel head, screwed both ends for iron pipes complete all as specified and directed by Engineer-in-charge.
S&F 450mm long PVC connection suitable for 15 mm bore with PTMT nuts on both sides complete all as specified and directed by Engineer-in-charge.
S&F Towel rail, 450mm long of PTMT fixed with and including chromium plated brass screws and wooden and plastic cleats (minimum weight 170gms) complete all as specified & directed by Engineer-in-Charge.
S&F brass chromium plated tubular towel rail 20mm dia; 'D' type, 600mm long between flanges fixed to plug with chromium plated brass screws including wooden or plastic cleat complete all as specified and directed by Engineer-in-Charge.
S&F hand faucet chromium plated complete all as specified and directed by Engineer-in-charge.
S&F plantex platinum stainless steel 304 grade paper holder with mobile phone stand (chrome finish) complete all as specified and directed by Engineer-in-charge.
S&F rotational moulded polyethylene water storage tank ISI Marked (cylindrical vertical double layered with closed top) hoisted and fixed in position of capacity 1000 litres including ball brass valve, high pressure with polythene float and flynut screwed for 20 mm dia GI pipe, 25mm bore GI washout pipe 15 cm long fitted with check nut, 20mm bore over flow pipe 1.50 metre long fitted with brass anti-mosquito nest coupling at the end of over flow pipe & 15mm bore GI air vent pipe 1.30 metre long fitted with tee at the end of air vent pipe (All GI pipes shall be medium grade) complete all as specified and directed by Engineer-in-Charge.
S&F 15 mm bore bib tap, cast copper alloy, chromium plated, long body, fancy type screwed down and screwed for iron pipe or for brass ferrule complete all as specified and directed by Engineer-in-charge.
S&F fancy type pillar tap, cast copper alloy with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ with long screwed shankS&Fly nuts, screwed suitable for iron pipes of 15mm bore complete all as specified and directed by Engineer-in-charge.
S&F 15mm bore stop valve, cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed by Engineer-in-charge.
S&F 20mm bore stop valve, cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed by Engineer-in-charge.
S&F 15mm dia stop cock cast copper alloy, fancy type with, chromium plated long shank and cup (concealed type) with crutch or butterfly handle screwed down high pressure, screwed both ends for iron pipe complete all as specified & directed by Engineer-in-charge.
S&F toilet paper holder chromium plated complete all as specified & directed by Engineer-in-Charge.
S&F chromium plated Soap dish holder including chromium plated brass screws and plastic cleats complete all as specified & directed by Engineer-in-Charge.
S&F vitreous china wash basin white flat back of size 630 x 450mm including a pair of angle iron brackets, PVC connection, 15mm dia fancy type, cast copper alloy chromium plated pillar tap with capastan head screwed down high pressure with long screwed shank and fly nuts, 32mm dia full threaded PTMT waste coupling including cutting for and pinning in ends of brackets and 32mm dia high density polythelene (HDPE) pipes for pressure rating 6 Kg/Sqcm with all fittings such as sockets, bends, tapers, etc complete all as specified and directed by Engineer-in-Charge.
S&F vitreous china squatting pan Orissa pattern, white of size 580x440mm with integral foot rests (excluding flushing cistern and flush pipe) including cast iron 'P' or 'S' trap, PCC filling and connection to trap and flushing pipe, antisyphonage pipe etc complete all as specified and directed by Engineer-in-charge.
S&F vitreous china wash down water closet pan (Pedestal pattern), white including connection to drain (or outgoing pipe) and to flushing pipe, anti-sypohonage pipe etc. & with plastic WC seat cover white closed pattern with flat bottom and cover and mild steel chromium plated or aluminized hinging device and jet spray complete all as specified & as directed by Engineer-in-charge.
S&F 10 litre capacity PVC valveless symphonic action type low level flushing cistern (ISI marked) including 32 mm dia PVC flush pipe connected to water closet with inlet, ball valve, float and handle complete all as specified and directed by Engineer-in-charge.
S&F vitreous china half stall type, flat back urinal of size 390 x 375 x 590mm, white including providing & fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with & including 60 mm long brass screws, pointing around urinal back in cement, with & including PTMT grating and union for discharge pipe, chromium plated urinal spreader including waste pipe of polythelene of low or high density or PVC 32mm dia complete all as specified and directed by Engineer-in-charge.
S&F Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) white including providing & fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with & including 60 mm long brass screws, pointing around urinal back in cement, with & including PTMT grating and union for discharge pipe including waste pipe of polythelene of low or high density or PVC 32mm dia inlcuding urinal spreader complete all as specified and directed by Engineer-in-charge.
S&F white or coloured PTMT shelf 450mm long fixed with and including chromium plated brass screw and plastic cleats (Minimum weight 300gms) complete all as specified and directed by Engineer-in-Charge.
S&F 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement including jointing to waste pipe fixed in cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate complete all as specified and directed by Engineer-in-Charge.
S&F 110mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement including jointing to waste pipe fixed in cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate complete all as specified and directed by Engineer-in-Charge.
S&F 110mm bore PVC (SWR) pipes single socketed in any length jointed with adhesive fixed to walls fixed with and including requisite Number of clamps made out of flat iron 25x4mm complete all as specified and as directed by Engineer-in-charge.
S&F 75mm bore PVC (SWR) pipes single socketed in any length jointed with adhesive fixed to walls fixed with and including requisite Number of clamps made out of flat iron 25x4mm complete all as specified and as directed by Engineer-in-charge.
S&F 110mm bore PVC (SWR) pipes single socketed in any length with solvent joints laid In trenches or in floors complete all as specified and directed by Engineer-in-charge.
S&F 75mm bore PVC (SWR) pipes single socketed in any length with solvent joints laid In trenches or in floors complete all as specified and directed by Engineer-in-charge.
S&F 110 mm bore PVC (SWR) bends any radius jointed with adhesive complete all as specified and as directed by Engineer-in-charge.
S&F 110mm bore PVC (SWR) junction, double (double T) equal or unequal complete all as specified and directed by Engineer-in-Charge
S&F PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed by Engineer-in-Charge"
Supplying, laying, jointing and testing 200 mm bore reinforced cement concrete pipes, class NP-2 including coller set in cement mortar (1: 1) complete all as specified and directed by Engineer-in-Charge.
M & L for PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in bed to drain pipe including forming cradles for 200mm dia of pipes and tested complete complete all as specified and directed by Engineer-in-Charge.
M&L for 150mm bore salt glazed stone ware drain pipes of grade ‘A’, ISI marked, laid to slope in trenches, jointed in CM (1:1) and tested complete all as specified and directed by Engineer-in-charge.
M&L for PCC (1:4:8) type D-2 using 40 mm graded stone aggregate in bedding to SGSW drain pipes, including packing under and haunching against the sides of pipes after they are laid and tested complete for 150 mm bore pipe complete all as specified and directed by Engineer-in-charge.
M&L for cutting into existing manhole/Septic tank/Soak well for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete (1:2:4) type B1, smooth finished and reforming benching as required for 150mm bore pipe complete all as specified and directed by Engineer-in-charge.
S&F Vitreous china urinal partition white of size 310x700 mm fixed in wall complete all as specified and directed by Engineer-in-charge.
Material & labour construction of Soak Well for 26 to 50 users as shown on drawing No.GE(A) /comp / 17 / 2016 complete all as specified and as directed by Engineer-in-charge. Notes : Irrespective to whether shown on drawing or not, excavation & earthwork shall be in any type of soil, brick work shall be in CM 1:4, over burnt brick bats shall be used for filling, PCC 1:4:8 type D2 using 40mm graded stone aggregate shall be provided in foundation, 20mm dia MS rungs made to shape painted with two coats of bituminous paint shall be provided, PCC 1:3:6 type C2 using 40mm graded stone aggregate shall be provided in plinth protection, 1.50m long 150mm bore cast iron sand cast inlet pipe shall be provided and slab shall be Precast RCC (1:2:4). Other details shall be as shown on drawings & as specified in particular specifications.
M&L for construction of Septic Tank for 10 users as shown on drawing No. BTD-016 sheet No. 1/3 to 3/3 complete all as specified and as directed by Engineer-in-charge. Notes : Irrespective to whether shown on drawing or not, excavation & earthwork shall be in any type of soil, RCC in foundation shall be M-20 (Nominal Mix) over lean concrete (1:3:6) using 40mm graded stone aggregate over brick hard core, all PCC shall be M-20 (Nominal Mix) using 20mm graded stone aggregate, all RCC work shall be M-20 (Nominal Mix), brick work shall be in CM 1:4, 20mm dia MS rungs made to shape painted with two coats of bituminous paint shall be provided. Other details shall be as shown on drawings & as specified in particular specifications.
M&L for point wiring complete with 1.5 sqmm (nominal cross sectional area) FRLSH PVC insulated multistandard unsheathed copper conductor cable with colour coding drawn in and including new PVC rigid conduit medium grade 20mm dia and suitable fittings, fixed on surface of wall or concealed or above ceiling with accessories such as pipe hooks, elbows, junction box, terminated in existing sunken box and covered with new 3mm thick bakelite plastic laminated sheet top cover fixed flush with wall using brass screws & cup washers including cutting chases in wall for conduits and making good the disturbed surfaces of wall and including 1.5 sqmm PVC insulated unshethed multistandard copper conductor wire as earth continuity to common earth and connecting to earth dolly for one light point, fan point, bell point controlled by one switch complete all as specified and directed by Engineer-in- charge.
All as per serial item No. 167 here-in-before but for One 3 pin 5 Amp socket outlet on the same board with other switches.
All as per serial item No. 167 here-in-before but for One 3 pin 5 Amp socket outlet on independent board.
All as per serial item No. 167 here-in-before but for One light point controlled by Two 2- way switches.
All as per Srl item No. 167 above, but wiring with cable of cross sectional area 2.5 Sqmm (nominal area) multi-stranded copper conductor FRLSH, PVC unsheathed cable 1100 Volts shade for one switch socket combination 6 pin, 5/15 Amps on independent board including 2.5 Sqmm PVC insulated multistandard unsheathed copper conductor wire as earth continuity to common earth dolly.
S&F switch piano flush button 5 Amps single pole, one way complete all as specified and directed by Engineer-in-charge.
S&F switch socket combination 3 pin, 5 Amps, 240 volts, flush type complete all as specified and directed by Engineer-in-charge.
S&F switch socket combination 6 pin, 5/15 Amps, 230 volts, flush type complete all as specified and directed by Engineer-in-charge.
S&F socket outlet 3 pin, 5 Amps 240 volts, flush type complete all as specified and directed by Engineer-in-charge.
S&F Lamp holder, insulated body with back plate etc complete all as specified and as directed by Engineer-in-Charge.
S&F ceiling rose surface bakelite 65mmx50mm with two or three terminal complete all as specified and directed by Engineer-in-charge.
S&F electronic fan regulator suitable for ceiling fan 1200mm/1400mm sweep, socket size, rotary type complete all as specified and directed by Engineer-in-charge.
S&F flush mounting factory made SPN DB 4 way, 240 Volt, Double door, IP-43 protection, IK-09 with metal door with 100 Amps copper bus bar, with neutral bar, earth bar and cables ties for cable management fully insulated bus bar complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 507610 or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F flush mounting factory made SPN DB 8 way, 240 Volt, Double door, IP-43 protection, IK-09 with metal door with 100 Amps copper bus bar, with neutral bar, earth bar and cables ties for cable management fully insulated bus bar complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 507611 or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F flush mounting factory made VTPN DB 4 way, 240 Volt, Double door, IP-43 protection, IK-09 with metal door with 160 Amps copper bus bar, with 02 neutral bar, 02 earth bar and cables ties for cable management fully insulated bus bar complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No DPX³ 507750 or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F MCB 6 to 32 Amps, Single Pole 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 408587 to 408595 or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F MCB 32 Amps, Single Pole & Neutral 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge. Make :- Legrand Cat Part No 408617 or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F in replacement MCB, TPN 63 Amps, having breaking capacity 10 KA, 'C' Curve complete all as specified and directed by Engineer-in-Charge. Make :- Legrand Cat Part No 408683 or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F MCCB 4 Pole 100 Amps, thermal magnetic release having, breaking capacity 25 KA, 415 Volt in the existing feeder pillar box including any addition / alteration to the panel to accommodate the new MCCB & making connections with 25x3 mm copper strip as required from main bus bars, making necessary welding work, metal work for fixing base plate etc and connections complete all as specified and as directed by Engineer-in-Charge. Make : Legrand Cat Part No. DPX³ 160 420055 or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F LED Lamp 12 watts suitable for normal holder complete all as specified and as directed by Engineer-in-charge.
S&F sheet metal plug & socket DB, SP, with a two pin and earth plug with socket, 230 Volts with & including one MCB SP ‘C’ Curve 10 kA, 20 Amps complete all as specified and directed by Engineer-in-charge. Make of DB :- Legrand Cat part No 507811 or equivalent in makes mentioned in Appendix 'A' here-in-after. Make of MCB :- Legrand Cat Part No 408593 or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F Energy efficient decorative ultra slim, prewired, lumiline 18 watt LED light fitting (Day cool light), batten type with drive & polycarbonate housing including tube rod and all accessories prewired fixed on wall / hanging complete all as specified and as directed by Engineer-in-charge. Make :- Havells Cat part No LUMILINEBS18WLED865SPCWH / Syska Cat part No SSK-RA1801 Wipro cat part No LL20-221-XXX-65-NE / Philips cat part No 61009 BL CDL or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F Energy efficient decorative ultra slim, prewired, aluminium body 20 watt LED light fitting (Day cool light), batten type with drive including polycarbonate diffuser with tube rod and all accessories prewired fixed on wall / hanging complete all as specified and as directed by Engineer-in-charge. Make :- Syska Cat part No SSK-ALB-20W or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F Energy efficient decorative ultra slim prewired 9 / 10watt (600mm length) LED light fitting (Mirror light) (Day cool light), surface and wall mounted LED batten, extruded aluminium housing with polycarbonate diffuser & integrated electronic driver and all accessories fixed on wall / hanging complete all as specified and as directed by Engineer-in-charge. Make :- Havells Cat part No LUMILINEBS9WLED865SPCWH / Syska cat part No SSK-T5T-9W / Crompton cat part No LCTLN-10-CDL or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F 14 watt LED mirror light fitting with high output diffuser complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed by Engineer-in-charge Make :- Crompton Cat Part No LCL-14-CDL or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F heavy duty exhaust fan 380 mm sweep, 900 RPM, single phase, 230 volts, 50 Hz with IP 55 protection as per IS-2312 1967 with louvers including suitable size MS angle frame for mounting the 380 mm sweep fan and connecting up and including 3 core,1.5 sqmm PVC insulated & PVC sheathed copper conductor flexible cable drawn in flexible conduit complete all as specified & directed by Engr-in-charge. Make :- Havells Model No Terbo Jet SP or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F exhaust fan 300 mm sweep,900 RPM trans air, with louver shutter suitable for operation on 230 volts, single phase , AC and connecting up including 2 core,1.0 sqmm PVC insulated & PVC sheathed copper conductor flexible cable drawn in flexible conduit complete all as specified & directed by Engr-in-charge. Make :- Havells Model No Terbo Jet SP or equivalent in makes mentioned in Appendix 'A' here-in-after.
S&F ceilling fan 1200mm sweep and making electric connections with 0.60RM long flexible cable of size 23/0.0076 mm complete all as specified and directed by the engr-in-charge complete all as specified and directed by Engineer-in-charge. Make : Havells Model No ES-50 Premium 5 or equivalent in makes mentioned in Appendix 'A' here-in-after. Note :- (i) MES No with stencil shall be marked on ceiling fan body using synthetic enamal paint. Cost of the same is included in the unit rate of this item.
S&F ceilling fan 1400mm sweep and making electric connections with 0.60RM long flexible cable of size 23/0.0076 mm complete all as specified and directed by the engr-in-charge complete all as specified and directed by Engineer-in-charge. Make : Havells Model No ES-50 Premium 5 or equivalent in makes mentioned in Appendix 'A' here-in-after. Note :- (i) MES No with stencil shall be marked on ceiling fan body using synthetic enamal paint. Cost of the same is included in the unit rate of this item.
S&F water storage heater (geyser) of 25 ltr capacity, energy saving 5 star rating complete with fire retardant cable and 3 pin plug 15/16 Amp, including grouting 4 Nos bolts in PCC (1:2:4) block in wall and making good the disturbed surfaces matching with existing including making connection to elerctric supply complete all as specified and directed by the engr-in-charge.
Supply, installation, testing and commissioning Split Type Air conditioner Electric driven (Single phase) 2 Ton, five Star rating capacity with remote control including MS stand and complete assecories all as per manufacturer's instructions in all respect as directed by Engineer-in-charge. Note :- Voltage stabilizer of required capacity shall be measured and paid for separeltly in respective item of BOQ.
Supply, installing & testing Voltage Stabilizer of capacity 5 KVA copper wound for automatic operation , single phase naturally air cooled indoor type & designed for input variation between 170V to 280V output voltage 230 V with accuracy of + 5% complete all as specified and directed by Engineer in charge.
S&F Sub main wiring complete with 2 single core 4 Sqmm (Nominal area) multi stranded copper conductor PVC insulated unsheathed cable FRLSH drawn in and including heavy duty PVC conduit ISI marked not less than 25mm dia concealed including single core multistranded copper conductor 2.5Sqmm size cable as earth continuous wire drawn in same conduit complete all as specified and directed by Engineer-in- charge Note : Two runs of 4 Sqmm single core cable and one run of 2.5 sqmm copper wire earth continuty conductor and conduit with fittings shall be measured as one RM.
S&F Sub main wiring complete with 2 single core 6 Sqmm (Nominal area) multi stranded copper conductor PVC insulated unsheathed cable FRLSH drawn in and including heavy duty PVC conduit ISI marked not less than 25mm dia concealed including single core multistranded copper conductor 6 Sqmm size cable as earth continuity wire drawn in same conduit complete all as specified and directed by Engineer-in- charge Note : Two runs of 6 Sqmm single core cable and one run of 6 sqmm copper wire earth continuty conductor and conduit with fittings shall be measured as one length.
S&F Recess mounting LED 2x2 luminaire, 36 watt, CCT 6000 k with drive, connector block etc. complete with all accessories internally pre-wired and including connecting up 3 core sheathed copper flexible cable 1.5 sqmm up to light fitting & connecting and testing complete all as specified and as directed by Engineer-in-charge. Make :- Crompton Cat Part No LCTLSNE-36-FO-CD / Philips Cat part No RC383B LED 36S-6500 PSU OD WH PIR / Syska Cat part No SSK-TVP-6060-36W / Havells Cat part No VENUSNEOHE2X2R36WLED840 PIRSENSOR or equivalent in makes mentioned in Appendix 'A' here-in-after. Note :- Warranty of 5 years or 50000 burning hours shall be given by the contractor.
S&F street light bracket made out of 40mm dia GI pipe light grade 1.5m long , bent to shape at 120 degree angle from vertical fixed along pole with and including required number of clamp made out of Flat iron 25mm x 6mm with nuts, bolts ,washers etc. duly painted with two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed by Engineer-in-charge.
S&F street light bracket made out of 40mm dia GI pipe light grade 1.20m long , bent to shape at 120 degree angle from vertical fixed along pole with and dirlling holes including required number of clamp made out of Flat iron 25mm x 6mm with nuts, bolts ,washers etc. duly painted with two coats of aluminium paint including any addition / alteration (if required) for fixing street light complete all as specified and as directed by Engineer-in-charge.
Supply, fixing and testing of LED Street / Security light fitting of 45 Watt, 5700K - 6500 K (including LED drive and internally prewired) complete with body robust, corrosion resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die cast aluminum alloy. The luminaries shall be monolithic construction totally enclosed dust and water proof with IP -65 / 66 protection as per IS - 10322-1982(Part -I) with latest amendments and input voltage range 140 - 300 V, AC, frequency 50 - 60 Hz ,P.F should be more than 0.9 with Total Harmonic Distortion THD(I) less than 15% ,cool white colour and lamp starting time should not be more than 10 second including 10 KV surge protection in built or external. Driver should be constant current constant voltage driver. Driver should have high voltage withstanding capacity upto 300 V, AC. Driver should also have double phase protection, no load , open circuit and short circuit protection .LED light fitting should be suitable for ambient temperature from -10 degree Centigrade to 50 degree Centigrade and humidity level 10% to 90 % RH. Covers should be polycarbonate/toughened glass to ensure minimum IP 65 degree protection. Cover should not degrade due to heating and ageing. The efficiency of LED luminaries system shall be more than 100 lumens per watt and must be certified by the LM-79 test report and including connection for street light from pole box with 1.5 Sqmm, 3 core PVC insulated stranded copper conductor FRLSH cable, 1100 Volts grade ISI marked including addition / alteration in bracket (if required) for fixing light fitting complete all as specified and directed by Engineer-in- charge. Make :- Syska Cat part No. SSK-SLF-F-45W-WL / Crompton Cat Part No LSTV-45-CDL / Havells Cat part No ENDURAPEARL NEOSL45WLED757SASYTOPC / Wipro Cat Part No LR02-501-XXX-57-XX or equivalent in makes mentioned in Appendix 'A' here-in-after.
Notes for srl Item No 204 :- (a) Tenderer shall submit test report of LED street light fitting from Government accredited test laboratory for LM - 79 and LM - 80 . (b) Contractor has to furnish a replacement warranty of 05 years for LED light fittings complete including lamps from the date of completion of CA. Contractor shall obtain warranty from the manufacturer of product on their letter head and submit the same to deparment alonwith his letter head. The product will be replaced free of cost in the following case :- (i) Manfacturing defects (ii) Failure due to mechanical and electrical impact. (iii) Drop in lumen (or lux at 1 m) below 90% of clamied values of lumen(or lux at 1 m) of the LED /Luminaries. (c) All LED light/luminare must meet the provision laid down in IS - 16101 , 16102 Part -I/II ,16103 Part -I , 16104 ,16105 ,16106 , 16108/2012 and 15885 Part -II / Section 13. (d) Scope of work shall include supply and fixing street light fittings on street light bracket fixed on poles, If street light fitting requires to fixed on existing street light bracket and any addition alterration required in bracket for fixing street light, In that case cost of additional / alteration is included in the unit rate of this item, which also includes needful T & P and required accessories such as 1.5 sqmm, 3 core PVC insulated stranded copper conductor cable for connection from pole box to light fitting etc complete including making connection, testing etc complete .No extra payment is admissible on this account. (e) Light fittings shall be provided with 10 KV surge protection as mentioned in description of item. If 10 KV surge protection is not provided in light fitting for which cat part is mentioned in BOQ. Contractor has to provide light fitting with 10 KV surge protection without any extra cost to department. (f) Contractor shall write CA No on street light fitting with synthetic enamel paint which should be visible from ground level. Cost of the same is included in the unit rate of this item nothing shall be extra paid on this account.
M&L for Construction of brick masonry valve pit of internal size 90cm x 90cm x 90cm including necessary excavation and earth work in soft/loose soil, brick work, plastering, white wash, PCC coping, MS frame made out of angle iron of size 40mmx40mmx6 mm, MS sheet cover of 3 mm thick fixed to angle iron frame by means of hinges welded to frame and painting with 2 coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces and grouting the frame in PCC 1:2:4 type B-1 including handle and locking arrangement with one number 50 mm dia brass pad lock complete all as specified and directed by Engineer - in - Charge Note :- (i) Brick wall shall be 23 cm thick built in cement mortar (1:4) (ii) Internal plaster shall be 15 mm thick in cement mortar (1:4) and external plaster upto 450mm from top shall be 20mm thick in CM (1:6) and remaining external surface shall be flush pointing in CM (1:6) as the work proceeds. (iii) PCC in foundation shall be 15 cm thick in cement concrete (1:4:8) type D2 using 40 mm graded stone aggregate extended 15 cm all around from the external face of the walls. (iv) PCC coping shall be 15 cm thick in cement concrete ( 1:2:4) type B1 using 20 mm graded stone aggregate including grouting of angle iron frame in PCC. (v) Three coats of white wash to internal surfaces of valve pit. (vi) Depth of valve pit shall be reckoned from the top of PCC in foundation.
M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to earth lead of GI wire 4 mm dia (8 SWG) by means of bolts, nuts and washers of the earth wire galvanised iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 15mm dia and water pipe 20mm dia GI light grade top of pipe with funnel & wiremesh, and bottom connected to earth plate by slit and two bolts/nuts/washers, PCC chamber in cement concrete (1:2:4) type B-1 and 40mm thick RCC cover, excavation & earth work complete all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009 complete all as specified and directed by Engr-in-charge. Notes :- (i) GI wire upto DBs or upto earth test point is included in this item. (ii) Outer edge of earth pit chamber shall be 1.5 metre away from the outer edge of PCC chamber. (iii) Minimum weight of reinforcement for RCC cover shall be 1 KG.
Supplying, laying, jointing, commissioning and testing XLPE insulated screened PVC bedded, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade of cross sectional area 10 sq mm 2 core confirming to IS-7098 (Part-I-1988) laid in trenches, along poles through pipes etc complete all as specified and directed by Engineer-in-charge. Notes :- (i) Excavation, earth work, sand cushioning, cable protection and GI pipe shall be measured & paid for separately under respective items of BOQ (ii) Road cutting / floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall deemed to be inclusive of the above provisions.
All as per item No 207 above but cable of cross sectional area 16 sq mm 2 core
All as per item No 207 above but cable of cross sectional area 50 sq mm 3.5 core
All as per item No 207 above but cable of cross sectional area 95 sq mm 3.5 core
M&L for dry sand (Tibba sand) and punning for cushioning to underground cable complete all as specified and directed by Engineer-in-charge Note: - For payment purpose thickness after punning shall be measured.
M & L for brick protection with old size sub class 'B' bricks laid flat, length of bricks across the route of underground cable all as specified and directed by Engineer-in-Charge.
S&F Galvanized iron tubing, 40mm bore light grade, ISI marked, including all fittings and laid in trenches / under road / drains, fixed to poles / walls with required numbers of clamps made out of 25x3mm flat iron, bolts, nuts and washers for protection of LT electric cable complete all as specified and as directed by Engineer-in-charge. Notes :- (i) Excavation & earthwork shall be measured & paid for separately under respective items of BOQ (ii) Cost of flat iron clamp if required is included in the unit rate of this item. Nothing extra shall be paid on this account..
Suppyling, installing, testing and commissioning of factory made outdoor type LT cubical panel board suitable for operation on 415 volts, 3 phase, 4 wire 50Hz supply system inlcluding bus bar chamber in centre ( vertically) and cable alley either side, outer shell shall be made out of 3.15mm thick CRCA sheet duly powder coated coated siemens gray shade and completely weather, vermin & dust proof, adequate air ventilation at sides & back, outer door shall be provided with double door fix with hinges and locking arrangements etc suitables to accomodate the following mentioned fittings and inner shell shall be made out of 2mm thick CRCA sheet duly powder coated & compartmentalized for each control gear including front openable single door with half nob type locking, inlcuding provision for taking out incoming and outgoing cables duly marked with reveted letter plated of appropriate size for each feeder / block cable, danger board, detachable plate at bottom for cable entry etc including double compression type cable gland with bottom frame made out of angle iron 40mm x 40mm x 5mm and 600mm long 4 legs duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer on exposed surfaces grouted in PCC 1:2:4 type B1 using 20mm graded stone aggregate blocks of size 30cm x 30cm x 60cm and 100mm thick PCC (1:2:4) type B1 floor over and including 100mm thick sub base of brick hardcore extended 100mm on all sides below panel body with and including following accesories :-
Contd/-… item No 214 Incoming (a) 200 Amps aluminium bus bar for phases and 100 Amps for Neutral duly insulated with heat shrinkable PVC sleeves and colour coded mounted on heavy duty epoxy insulators in seprate compartment and internally prewired - 01 Set (b) MCCB 250 Amps, 36 KA, 4 Pole, thermal Magnetic release type - 01 No Make - Legrand Cat Part No DPX³ 250 420249 or equivalent in makes mentioned in Appendix 'A' here-in-after. Outgoing (a) MCCB 100 Amps, 25 KA, 4 Pole, thermal Magnetic release type - 03 Nos Make - Legrand Cat Part No DPX³ 250 420055 or equivalent in makes mentioned in Appendix 'A' here-in-after. (b) Digital multi function meter (voltmeter 0-500V, Ammeter 0-400A, Frequency meter) (c) Indicator lamp 240 volts LED type complete - 01 Set (set of three) (d) CTs 200/5 Amps - 01 Set (set of three) (f) Internal all links & control cable and indicators - set of three Note :- Cost of PCC, excavation and earth work is included in the unit rate of this item nothing extra shall be paid on this account.
S&F copper suction pipe line of suitable size and gauge as per manufacturers recommendation complete with cutting, brazing and insulation work including fittings required at site complete all as specified and directed by Engineer-in-Charge.
S&F copper discharge pipe line of suitable size and gauge as per manufacturers recommendation complete with cutting, brazing and insulation work including fittings required at site complete all as specified and directed by Engineer-in-Charge. Note : - Pipe to be measured other than the standard qty received with units.
M/s JUGAL KISHORE MISHRA AND SONS
GARG ENTERPRISES
S.K BUILDERS AND ENGINEERS
M/S GODARA CONSTRUCTION CO.
PACHR BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .