Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹23.1 LAccepted-AOC | L-1 | Accepted-AOC Being lowest bidder | |
| 2 | L-2₹40.9 L+₹13.1 L (46.8%)Rejected-Finance | L-2 | Rejected-Finance Other than lowest bidder | |
| 3 | L-3₹41.9 L+₹14.0 L (50.1%)Rejected-Finance | L-3 | Rejected-Finance Other than lowest bidder | |
| 4 | Rejected-Technical | - | Rejected-Technical Docuemnts not uploaded as mentioned in NIT |
Tender Value
Refer Docs
EMD Value
₹76,000
Closing Date
28 Jun 2022, 6:00 pmClosed
GE Jammu
GE Jammu c/o 56 APO Pin-900277
PETTY REPAIR TO INTERNAL WIRING IN ZONE A, REPAIR/MAINT OF VOLTAGE STABILIZER, DG SETS, BATTERY BANKS, SOLAR WATER GEYSERS, EARTHING SYSTEM OF LIGHTENING CONDUCTOR, ARRESTOR, BLDG AND ALLIED ITEMS AT DAMANA UNDER GE JAMMU
2022_MES_525953_1
GEJC-16/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AoR of GE Jammu
Please refer Tender Documents
9 documents required · 9 mandatory
₹500
GE Jammu
₹76,000
Yes
7 Oct 2022
28 May 2022
30 Jun 2022
28 May 2022
28 Jun 2022
14 Jun 2022
Amount
Taking down old unserviceable copper / aluminium point wiring concealed / batten (light, fan, socket or power) complete, including fixture and fittings such as switches, sockets, ceiling roses, bell push, bell electric, lamp holder, bulk head fitting, pendants, regulators, sockets, light fitting and any type switch board wooden / iron, round block etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed.
Material and Labour for point wiring for one light / fan / call bell point controlled by one 5 Amp switch with 1.5 Sqmm single core multistranded copper conductor FRLS, PVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 Sqmm copper conductor multistranded FRLS, PVC insulated (unsheathed) drawn into and including new concealed PVC rigid / 1.8mm wall thickness ISI marked including pressed steel sunken / terminal boxes with existing colour terminated boxes of modular metal flush boxes of any way i.e. (1 to 8 way as per site requirement) for mounting switches, sockets, fan regulators etc complete all as specified and as directed for the following: - Note: - (a) Suitable module white cover sheets with frame as specified to be provided in replacement to mild steel / Galvanised sunken boxes and measured and paid separately as per relevant item. (b) Wiring shall be done by using proper colour coding. (c) Earth wire shall be of green colour. (d) On RCC roof / ceiling PVC conduit shall be provided on surface with proper fixing clamps all as directed by Engineer-in-Charge.
Description same as per Ser Item No 2.00 here-in-before but for 5 Amp socket outlet on same board complete all as specified and as directed.
Description same as per Ser Item No 2.00 here-in-before but for socket outlet 5 Amps independent board complete all as specified and as directed by Engineer-in-Charge.
Description same as per Ser Item No 2.00 here-in-before but for one 6 pin socket outlet 15 Amps on independent board with cables 2.5 Sqmm size complete all as specified and as directed.
Supply and fixing in replacement modular switch 1 way 6A, 1 module, 240 Volts ISI marked complete all as specified and directed.
Supply and fixing in replacement modular switch 1 way 16A, 1 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in replacement socket, 6A - 2/3 pin combined 2 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in replacement socket 6A / 16A - 2/3 pin combined 2 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in replacement fan step regulator, 120W 1 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in replacement modular metal flush box 2 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in replacement modular metal flush box 3 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in replacement modular metal flush box 4 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in replacement modular metal flush box 6 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in replacement modular metal flush box 8 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in replacement modular white cover plate with frame 1 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in replacement modular white cover plate with frame 2 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in replacement modular white cover plate with frame 3 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in replacement modular white cover plate with frame 4 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in replacement modular white cover plate with frame 6 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in replacement modular white cover plate with frame 8 module, 240 volts ISI marked complete all as specified and directed.
Material and Labour for replacement distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 12 way 240 volts, double door complete all as specified and as directed by Engineer-in-Charge. Note: - Distribution board and MCB's should be of same make.
Material and Labour for replacement distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 8 way 240 volts double door complete all as specified and as directed by Engineer-in-Charge. Note: - Distribution board and MCB's should be of same make.
Material and Labour for replacement distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 6 way 240 volts double door complete all as specified and as directed by Engineer-in-Charge. Note: - Distribution board and MCB's should be of same make.
Supply and fixing in replacement 240 V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 Amp, in the MCB DB complete with connection testing and commissioning all as specified and as directed.
Supply and fixing in replacement 240 V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 40 Amp, in the MCB DB complete with connection testing and commissioning all as specified and as directed.
Supply and fixing SPN 32 Amp rating 240 V, 10 KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning all as specified and as directed.
Supply and fixing SPN 40 to 63 Amp rating 240 V, 10 KA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning all as specified and as directed.
Charges for attending day to day / E/M petty complaint in respect of repair / rectification of fault in electric fitting MCB DB's, internal wiring LT Panel and fixture and rectify the faults and replacement of unserviceable any type of fitting / fixture, MCB's, any type, bakelite sheet, restore the electric supply and made the item functionable light point, fan point, socket point 5A / 15A, switches, sockets, fan regulator, light fixtures any type of lamp, MCB DB's and all electrical accessories and day to day / door to door maintenance, making the points / accessories serviceable in all respect with replacement of any minor parts like small length of wires (not more than 1 metre) and other connected minor accessories. Work shall also include to check and removal of leakage in service connection / submains of houses as and when directed. The scope also include cutting of existing bakelite sheet to accommodate new wiring accessories all type of electric fitting / fixture all as specified and as directed.
Note: - Any other replacement of major items shall be measured and paid under respective items as supply only. Fixing charge of fitting / fixture and MCB's of any type is deemed to be included in the above item. (a) Contractor representative / Engineer will report to complaint cell for morning and afternoon to collect routine / urgent nature of complaint related to internal electric supply till completion of contract. The work shall be attended by the contractor immediately. The contractor will ensure availability of manpower (Two Electrician and Two Helper) equipped with all sort of petty items such as insulation tape, galvanised screws, nuts, bolts, washers etc required to accomplish the job. The contractor will also ensure the availability of every type of requisite T&P items to his tradesman. All routine / urgent job received on job slip will be repaired and got signature of users and will be deposited to complaint cell with in 24 hours. In case of any delay in attending the complaint more than 12 hours after handing over of routine / urgent works, the contractor shall be liable to pay the penalty as per the item rate. (b) Contractor shall maintain the maintenance register showing all daily complaints received and shall maintain job card for attending complaints. The signature of the user shall be obtained on the job card showing the materials used in the work after completion of the job. (c) If the Contractor did not attend complaint, a penalty of Rs 300/- per day per complaint recovery shall be made from the work done amount.
(d) The MES Department is not responsible for the payment of staff hired by contractor for attending complaints. The charges for attending the complaints by the Electrician will be deemed to be included in the item rate, as all the items of CA are to be supply and fixed by the contractor. (e) Proper record (date wise) of complaints received and rectified by the contractor shall be produced for verification at the time of payment of each RAR/Bill. (f) All the complaint slip, register and connected document will be provided by the contractor without any extra cost. (g) After any repair the site has to be cleaned and make the surface good.
Supply only switch piano, flush type single pole one way 5 Amp, 240 Volts ISI marked complete all as specified and directed.
Supply only socket outlet 2 in 1, 3 pin, 5 A complete all as specified and directed.
Supply only switch socket outlet combined 5 pin 5 amp flush type, 240 volts ISI marked complete all as specified and directed.
Supply only switch socket outlet combined 2 in 1, 3 pin 5 amp and 15 amp flush type, 240 volts ISI marked complete all as specified and directed.
Supply only socket outlet 3 pin, 15 Amp, flush type, 240 Volts, 6 pin flush type ISI marked complete all as specified and directed.
Supply only switch piano, flush type single pole one way 15 Amps, 240 volts ISI marked complete all as specified and directed.
Supply only ceiling rose 3 terminal surface type complete all as specified and as directed.
Supply only lamp holder, PVC / Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed.
Supply only bell, AC 230 Volts single pole complete all as specified and directed.
Supply only bell push flush type single pole one way 5 amp complete all as specified and directed.
Supply only MCB SP 6 to 32 Amps, 240 Volts 'B' curve miniature circuit breaker (MCB) complete all as specified and directed.
Supply only SPN 32 Amp rating 240 V, 10 KA 'B' curve miniature circuit breaker (MCB) complete all as specified and directed.
Supply only SPN 40 to 63 Amp rating 240 V, 10 KA 'B' curve miniature circuit breaker (MCB) complete all as specified and directed.
Supply only stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as required complete all as specified and directed.
Material and labour in replacement of self ballast LED retrofit lamp with PVC body and PC Diffuser 9 watt 230 Volt 6500K complete all as specified and directed.
Supply and fixing in replacement of LED light fittings 1 x 20W, 220 V, AC decorative box type complete with LED tube rod 20 watts driver, holder and power factor >0.95, 100 Lumen / Watt, 6500 K cool day type conforming to ISI including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete (4' ft long) with LED rod 20 watt, 230 Volts 50 Hz complete all as specified and as directed.
Supply and fixing in replacement LED light fitting mirror type with high output diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
Supply and fixing in replacement wall mounted decorative type luminaries IP-65 with diffuser 10 watt, 230 Volts LED type complete with 10 watt LED Bulb all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders and LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed.
Supply and fixing in replacement stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as required complete all as specified and as directed.
Supply and fixing in replacement calling bell Ding Dong / buzzer AC 230 Volts, single pole complete all as specified and as directed.
Material and labour in replacement for sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 6 Sqmm for phase and neutral and one run of 4.0 Sqmm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the new rigid PVC concealed conduit fixed on wall. Two runs of cable for phase / neutral and one run of cable for earth will be measured and paid as one unit length all as specified and as directed. Note: - Wiring shall be done in proper colour coding.
Material and labour in replacement for sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 4 Sqmm for phase and neutral and one run of 2.5 Sqmm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the new rigid PVC concealed conduit fixed on wall. Two runs of cable for phase / neutral and one run of cable for earth will be measured and paid as one unit length all as specified and as directed. Note: - Wiring shall be done in proper colour coding.
Material and labour in replacement for wiring for circuit with proper existing colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 1 run 2.5 Sqmm for phase, drawn through the existing rigid PVC concealed conduit fixed on wall including taking down existing unserviceable wiring complete all as specified and as directed. Note: - Wiring shall be done in proper colour coding.
Material and labour in replacement for wiring for circuit with proper existing colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 1 run 1.5 Sqrmm for phase, drawn through the existing rigid PVC concealed conduit fixed on wall including taking down existing unserviceable wiring complete all as specified and as directed. Note: - Wiring shall be done in proper colour coding.
Material and labour for Earthing complete with galvanised mild steel earth plate electrode of size 600 x 600 x 6mm thick buried directly in ground earth (in vertical) earth pit not less than 2.25 metre deep below normal ground level with top edge of the earth plate not less than 1.5 metre below ground level connected to galvanised iron or earth lead wire 4mm dia (8 SWG) by means of nut, bolt, check nuts and washer of galvanised iron including PCC pit in PCC (1:2:4) type B-1 precast RCC cover slab using reinforcement with suitable handle made of round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube for watering with one end fixed with cast iron funnel and wire mesh 15mm dia bore light grade galvanised steel tubing upto 5 m length for drawing earth lead wire protection, common salt, charcoal, etc complete all as shown in electrical plate No 3 of SSR Part-I and testing on completion all as specified and as directed.
Description same as per Ser Item No 55.00 here-in-before but using galvanised iron strip of 32 X 6mm as earthing lead complete all as specified and as directed.
Supply and fixing in replacement plug top 15 Amps complete all as specified and as directed.
Material and labour for decorative post top lantern light for 360° indirect light with IP-65 protection, resistant to impact and corrosion, glare-free and better uniformity including fixing of the light on the existing pipe arrangement and necessary wiring to light from nearest junction box complete all as specified and as directed.
Supply and fixing in repair gate / post top lantern fittings, Orbiss type, die cast aluminium housing, frosted polycarbonate diffuser, matt grey finish with inbuilt LED 12 Watt, WW, IP-54, 300 mm Ht, 248mm dia, testing on completion complete all as specified and directed by the Engineer-in-Charge.
Supply and fixing in repair gate / post top lantern fittings, Monaco type, decorative fixture die cast aluminium housing, transparent glass diffuser, black colour with LED bulb 12 Watt, WW, IP-54, testing on completion complete all as specified and as directed by the Engineer-in-Charge.
Dismantling and taking down old unserviceable building security lights and material and labour for new LED street light fittings of 30 watt system wattage and high pressure die cast aluminium housing with sealed toughened glass cover, TIP-66 protection suitable for pole mounting SMD LED array with lense, cool white 6500 K, LED efficacy >120 lm/W and system efficacy 110 lm/W, 240 Volts AC, 50 Hz, CRI>70% operating voltage range 160 V-270 V, Power factor >0.95, working temperature range -20ºC to 60ºC, built in surge protection more than 10 KV with facility of power supply shall be removed without removing light fitting from pole including make proper connection complete including cutting, welding, drilling holes, nut, bolts, washer complete all as specified and as directed by Engineer-in-Charge.
Dismantling and taking down old unserviceable building security lights and material and labour for new LED street light fittings of 45 watt system wattage and high pressure die cast aluminium housing with sealed toughened glass cover, TIP-66 protection suitable for pole mounting SMD LED array with lense, cool white 6500 K, LED efficacy >120 lm/W and system efficacy 110 lm/W, 240 Volts AC, 50 Hz, CRI>70% operating voltage range 160 V-270 V, Power factor> 0.95, working temperature range - 20ºC to 60ºC, built in surge protection more than 10 KV with facility of power supply shall be removed without removing light fitting from pole including make proper connection complete including cutting, welding, drilling holes, nut, bolts, washer complete all as specified and as directed by Engineer-in-charge.
Supply, fixing, commissioning and testing LED flood lights 50 watts, exclusive innovative IP-65 protection flood lights luminaire with 50 W high power COB LED as light source in repair complete all as specified and as directed.
Supply, fixing, commissioning and testing LED flood lights 30 Watts, exclusive innovative IP-65 protection flood lights luminaire with 30 W high power COB LED as light source in repair complete all as specified and as directed.
Supply and fixing black epoxy powder coated cone bollard light with die cast aluminium housing, opal diffuser with in built LED 10 Watt CW, IP-65, height 600mm, 125mm dia on top in repair complete all as specified and directed by Engineer-in-Charge.
Supply and fixing black epoxy powder coated cylindrical bollard light with die cast aluminium housing, opal diffuser with in built LED 10 Watt CW, IP-65, height 600mm, 125mm dia on top in repair complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement roof mounted hanging decorative type luminaries IP-54 with glass diffuser suitable for 10 Watt LED, WW, 230 Volts complete including 10 watt LED Bulb all as specified and as directed by Engineer-in-Charge.
Material and Labour in replacement for 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm GI suspension wire, one twin core cable flat or circular of size 10 Sqmm 2 core complete all as specified and as directed by Engineer-in-Charge.
Material and Labour in replacement for 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm GI suspension wire, one twin core cable flat or circular of size 6 Sqmm 2 core complete all as specified and as directed by Engineer-in-Charge.
Material and Labour in replacement for 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm GI suspension wire, one twin core cable flat or circular of size 4 Sqmm 2 core complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for repair / maintenance / servicing / overhauling to DG set having capacity 10 KVA to 100 KVA installed at pump house / site complete with entire cleaning checking of fuel pipe, lubricant oil pipe, rubber hose, panel wiring, fan belt, earthing strip, nut, bolts, exhaust pipe, battery pads, radiator hose, measuring instruments and tightening all nuts, bolts, MS rubber hose clamps and to make the system leak proof and serviceable complete with including painting to entire DG set with heat resistant smoke grey synthetic enamelled paint and base frame channel with black paints including replacement of fuel filter elements all types as under and minor spare parts, nuts, washer, radiator top capacity, battery terminal brass bolts type and changing engine oil including cleaning to oil sump and testing on full load after servicing complete all as specified and as directed. Note: - Spare parts shall be measured and paid separately.
Supply only fuel filter primery with 'O' ring.
Supply only fuel filter secondary with 'O' ring.
Supply only lubricant oil filter with 'O' ring.
Supply only lubricant oil by pass filter with 'O' ring.
Supply only air cleaner element.
Supply only fan belt set for radiator, alternator and water pump etc.
Supply only battery lead copper heavy duty having length 1.5 metre each complete with one side banjo bolt and other side brass battery terminal bolt type set of 2 pieces.
Supply only rubber hose pipe for radiator, water pump, set of 5 pair complete with MS clamp of suitable size.
Repair / servicing of self starter 12 volts DC complete with and including replacement burnt / unserviceable spare parts, clutch assembly, carbon brush, solenoid switch, plunger, armature and refixing for DG set 10 KVA to 100 KVA complete all as specified and as directed.
Dismantling / repair / overhauling of water pump assembly of DG set upto 100 KVA by replacing defective part like pump, shaft, impeller CI, mechanical seal, water set gasket, hub for pulley, set screws, bearing grooves nuts, spacers and spring washer and metling / machine work if any and refixing after repair complete all as specified and as directed.
Dismantling / repair / overhauling of charging alternator (dynamo) of DG set having capacity of 10 KVA to 100 KVA and replacement of unserviceable / defective parts like carbon brushes, bearing, pulley, spacer, commutator assembly, armature, washer etc. and refitting after repair complete all as specified and as directed.
Material and Labour for replacement of engine oil servo super grade 20 / 40W including cleaning of oil sump throughly all as specified and directed.
Dismantling / taking down radiator assembly for repair / servicing of DG set 10 KVA to 100 KVA and carry out complete internal cleaning, brazzing to tubing and rectification of leakage and refitting including replacement of minor spare parts like inlet / outlet rubber hose with MS clamps, pipe for thermostat to radiator washer, nut, bolts all as specified and as directed.
Disconnecting FIP pump of DG set of following capacity and carry out complete servicing / calliberation from authorised service centre and refitting after calliberation including replacement of injector nozzle, delivery valves, gasket, fuel pump gear, flange assembly, plunger, copper washer, adaptor, set both etc. as required to make the FIP serviceable.
DG set capacity 10 KVA to 63 KVA
DG set capacity 70 KVA to 100 KVA
Supply and fixing in repair self starter 12 volts 180 AH heavy duty suitable for DG set 10 KVA to 63 KVA, 70 KVA to 100 KVA complete all as specified and as directed.
Supply and fixing in repair self starter 24 volts 180 AH heavy duty suitable for DG set 10 KVA to 63 KVA, 70 KVA to 100 KVA complete all as specified and as directed.
Supply and fixing in replacement of battery charger heavy duty, 150 / 180 AH, 24 volts with lead, Volt / Amp meter complete all as specified and as directed.
Supply and fixing in replacement set of high pressure of fuel pipe of engine complete nut, set volt, clamp and spring washer etc complete all as specified and as directed.
Supply and fixing in replacement of oil sump gasket complete all as specified and as directed.
Supply and fixing in replacement of water temp switch suitable for DG set 10 KVA to 100 KVA complete all as specified and as directed.
Supply and fixing in replacement of AVR suitable for DG set 10 KVA to 100 KVA all as specified and directed.
Supply and fixing in replacement of diode and rectifier for alternator suitable for DG set 10 KVA to 100 KVA all as specified and directed.
Supply and fixing in replacement of onload open execution change over switch 4 pole 415 volts, 100 Amp in sheet steel enclosure conforming to IS with side operated handle complete with fixing on wall and angle iron bracket of size 40 x 40 x 6mm thick as per size requirement or all as specified and as directed.
Supply and fixing in replacement of onload open execution change over switch 4 pole 415 volts, 160 Amp in sheet steel enclosure conforming to IS with side operated handle complete with fixing on wall and angle iron bracket of size 40 x 40 x 6mm thick as per size requirement or all as specified and as directed.
Supply and fixing in replacement of onload open execution change over switch 4 pole 415 volts, 200 Amp in sheet steel enclosure conforming to IS with side operated handle complete with fixing on wall and angle iron bracket of size 40 x 40 x 6mm thick as per size requirement or all as specified and as directed.
Supply and fixing in replacement of onload open execution change over switch 4 pole 415 volts, 250 Amp in sheet steel enclosure conforming to IS with side operated handle complete with fixing on wall and angle iron bracket of size 40 x 40 x 6mm thick as per size requirement or all as specified and as directed.
Supply and fixing in replacement Alternator flywheel ring for DG set capacity 10 to 63 KVA complete with disconnecting alternator from the engine and for replacement of flywheel complete all as specified and as directed.
Supply and fixing in replacement Alternator flywheel ring for DG set capacity 70 to 100 KVA complete with disconnecting alternator from the engine and for replacement of flywheel complete all as specified and as directed.
Labour for Dismantling to alternator from the engine of capacity 10 KVA to 100 KVA by opening nut and bolt and transport to workshop for repair / maintenance and rewinding with super enamelled heat resistant copper winding wire of existing size and no's of turn complete with insulating material i.e. varnishing, bamboo strips, cotton thread / tape, leather paper etc and drying the winding complete with checking, realignment, welding, grinding, earth work and polishing the alternator rotor shaft and refitting the alternator with engine after repair / rewinding and testing on full load all as specified and directed. Note: - Copper winding wire will be measured and paid separately.
Rewinding coil of alternator 10 KVA to 100 KVA with super enamelled heat resistant copper winding wire of existing size and no of turn conforming to ISI complete all as specified and as directed.
Material and labour for replacement of unserviceable ball bearing of alternator heavy duty conforming to ISI suitable for DG set alternator 63 KVA to 100 KVA complete all as specified and directed.
Repair / maint / servicing to DG set control AMF panel of capacity 63 KVA to 100 KVA including replacement of internal panel wiring, automatic auto cut switch with relay, sensor unit multifunctional digital meter and make the panel serviceable and testing all as specified and directed.
Material and Labour for replacement of unserviceable battery 12 volt 200 AH suitable for DG set 63 KVA to 100 KVA complete all as specified and directed.
Material and Labour for replacement of unserviceable battery 12 volt 180 AH suitable for DG set 63 KVA to 100 KVA complete all as specified and directed.
Material and Labour for replacement of unserviceable battery 12 volt 150 AH suitable for DG set 63 KVA to 100 KVA complete all as specified and directed.
Material and Labour for replacement of unserviceable battery 12 volt 120 AH suitable for DG set 63 KVA to 100 KVA complete all as specified and directed.
Material and Labour for replacement of unserviceable speed controler with auto cut sensor unit for DG set capacity 63 KVA to 100 KVA complete as specified and directed.
Dismantling all incoming / outgoing electric connection carefully of transformer, voltage stabilizer, LT panel, switch, change over etc and repair the cable, fixed properly with proper aluminium thimble / lugs including preparation of cable end for jointing (incoming / outgoing cable connection for each cable will be measured as one job each) complete all as specified and as directed. Note: - Thimble shall be measured separately under respective items.
Labour for disconnecting all incoming / outgoing electric connction carefully of fully automatic servo voltage stabilizer having capacity 20 to 100 KVA and transport to workshop for repair / servicing and including dismantling top cover of stabilizer and taking out the coil, drain out the transformer oil and refilling after dehydration of transformer oil, cleaning internally, including replacement of unserviceable body nut, bolts, washers, top gasket of cork sheet 6mm thick, replacement of internal circuit wiring if any suitable size of copper wire and painting of stabilizer with heat resistant smoke grey synthetic enamelled paint including preparation of old rusted surfaces and writing MES NO, SM MES No, capacity, Ser No, Location etc and reinstallation / connecting electric connection with replacement of proper size Aluminium lugs and testing on full load at site complete all as specified and as directed. Note: - (a) Spare parts shall be measured and paid separately.
Supply and fixing in synchronous motor single phase 230 Volt suitable for servo voltage stabilizer having capacity 20 to 100 KVA complete all as specified and as directed.
Supply and fixing in PCB suitable for servo voltage stabilizer having capacity 20 to 100 KVA complete all as specified and as directed.
Supply and fixing in dimmer motor suitable for servo voltage stabilizer capacity 20 to 100 KVA complete all as specified and as directed.
Supply and fixing in toggle On / Off switches for stabilizer capacity 20 to 100 KVA complete all as specified and as directed.
Supply and fixing in replacement Volt meter 0-500 Amp 96mm Square type 3 phase 230 volt 50 Hz complete all as specified and as directed.
Supply and fixing in replacement Ampere meter 0-400 Amp, 96mm Square type 3 phase 230 volt 50 Hz with CT of suitable ratio complete all as specified and as directed.
Supply and fixing in replacement gun metal gate or glove valve 20 mm for drain out of oil complete all as specified and as directed.
Supply and fixing in unserviceable brass / gun metal stud bush suitable for 20 to 100 KVA complete with connecting rod of suitable length and dia with necessary nut, bolt, washer, bushing packing to prevent the leakage from bushes and necessary connection all as specified and as directed.
Dehydration of Transformer oil and dielectric strength of oil achieved not to be less than 40 KV at 2.5 mm gap complete all as specified and as directed.
Supply and filling of new transformer oil for top up upto automatic servo voltage stabilizer including heating and dielectric strength not to be less than 60 KV complete all as specified and as directed.
Taking out main coil of voltage stabilizer 20 to 100 KVA for repair / rewinding with super enamalled copper winding wire of existing gauge including PVC insulated sheet sleeve, varnishing etc all as required and refixing to the stabilizer after testing all as required at site or all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement MCCB TPN 400 Amps, 415 Volts, 36 KA, 4 Pole, Ics=100% Icu, overload adjustable short circuit adjustable type including complete connection all as per direction of Engineer-in-Charge.
Supply and fixing in replacement MCCB TPN 250 Amps, 415 Volts, 25 KA, 4 Pole, Ics=100% Icu, overload adjustable short circuit adjustable type including complete connection all as per direction of Engineer-in-Charge.
Supply and fixing in replacement MCCB TPN 160 Amps, 415 Volts, 25 KA, 4 Pole, Ics=100% Icu, overload adjustable short circuit fixed type including complete connection all as per direction of Engineer-in-Charge.
Supply and fixing in replacement MCCB TPN 100 Amps, 415 Volts, 16 KA, 4 Pole, Ics=100% Icu, overload adjustable short circuit fixed type including complete connection all as per direction of Engineer-in-Charge.
Supply and fixing in replacement MCCB TPN 63 Amps, 415 Volts, 10 KA, 4 Pole, Ics=100% Icu, overload adjustable short circuit fixed type including complete connection all as per direction of Engineer-in-Charge.
Disconnecting and taking out defective underground cable any size and any type from trenches, pole, pipe, floor, wall etc complete all as specified and as directed.
Supply, laying and testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 150 Sqmm 3½ core including Al thimbles and nut / bolts / washers for connection with LT panel, DG set and voltage stabilizers complete all as specified and as directed.
Supply, laying and testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 Sqmm 3½ core complete all as specified and as directed.
Supply, laying and testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 Sqmm 3½ core complete all as specified and as directed.
Supply, laying and testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 Sqmm 3½ core complete all as specified and as directed.
Supply, laying and testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 Sqmm 3½ core complete all as specified and as directed.
Supply, laying and testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 Sqmm 3½ core complete all as specified and as directed.
Taking down and strip opening to geyser of any make and capacity 25 / 35 / 50 litres including disconnection of all water pipe connection and taking out water inlet / outlet assembly, removing glass wool, the inner tank, descaling the assembly and tank, detecting the leakage, welding / brazing the defective parts, repacking the glass wool and refixing the same after making it functional including replacement of worn out nuts, bolts, washers etc complete all as specified and as directed. Note: - Cost of material and labour for providing new items shall be measured under relevant items of Schedule 'A'.
Material and labour for replacement of water inlet and outlet geyser assembly of existing make as required at site with rubber gasket suitable for geyser of 25 / 35 litres capacity electric driven water storage heater with provision of housing for thermostat assembly, heating element fixing arrangement nuts, bolts and washers etc complete all as specified and as directed.
Material and labour for replacement of water inlet and outlet assembly of existing make as required at site with rubber gasket suitable for geyser of 50 litres capacity electric driven water storage heater with provision of housing for thermostat assembly, heating element fixing arrangement nuts, bolts and washers etc complete all as specified and as directed.
Material and labour for replacement thermostat, switch for electric water heater storage type of capacity 25 / 50 litre, 230 Volts of existing make of geyser complete all as specified and as directed.
Material and labour for replacement heating element with triangular base / round base, single phase, 230 Volt, capacity 2 KW of existing make complete all as specified and as directed.
Material and labour for replacement heating element with triangular / round base, single phase, 230 Volt, capacity 1.5 KW of existing make complete all as specified and as directed.
Material and labour for replacement pressure release valve conforming to relevant IS 15mm bore suitable for fixing with GI pipe / tubing 15mm bore complete all as specified and as directed.
Material and labour for replacement of heavy duty PVC connection (For Hot water) nylon threaded 450mm large (18") 15mm bore including brass nuts, rubber washers complete on both ends complete all as specified and as directed.
Material and labour for replacement of heavy duty PVC connection (For Cold water) nylon threaded 450mm large (18") 15mm bore including brass nuts, rubber washers complete on both ends complete all as specified and as directed.
Material and labour for replacement of indicator lamps round / rectangular type 230 Volt AC suitable for geyser of any capacity including providing electric connections complete all as specified and as directed.
Material and labour for replacement water storage inner tank of stainless steel heavy duty confirming to ISI 25 / 35 litres capacity geyser, with provision for fixing 15mm dia galvanized air release valve complete all as specified and as directed.
Material and labour for replacement water storage inner tank of stainless steel heavy duty confirming to ISI 50 litres capacity geyser, with provision for fixing 15mm dia galvanized air release valve complete all as specified and as directed.
Supply and fixing in replacement MCB SPN 32 Amps, 240 Volts, rupturing capacity 10 KA, 'C' series complete all as specified and as directed.
Supply and fixing in replacement plug top 15 Amps, 3 pins complete all as specified and as directed.
Material and labour for painting of geyser of capacity 25 / 35 / 50 litre complete with superior quality synthetic enamel white paint by spray painting after scrapping old paint and making surface clean complete all as specified and as directed.
Material and labour for replacement Non return Valve 15mm dia complete all as specified and as directed.
Material and labour for replacement split bottom cover (two pieces) suitable for 25 to 50 litres geysers complete with fixing arrangements etc as required at site complete all as specified and as directed.
Material and labour for replacement rubber gasket heavy duty of water inlet outlet assembly suitable for 25 litres capacity geyser complete all as specified and as directed.
Material and labour for replacement outer shell suitable for 25 / 35 litres geyser made out of GI sheet heavy duty confirming to ISI suitable for existing make of geyser complete factory manufactured paint complete all as specified and as directed.
Material and labour for replacement outer shell suitable for 50 litres geyser made out of GI sheet heavy duty confirming to ISI suitable for existing make of geyser complete factory manufactured paint complete all as specified and as directed.
Supply and fixing in replacement glass wool suitable for geysers complete all as specified and as directed.
Repair / maintenance / servicing to solar water heater system having a capacity 100 to 200 LPD complete with descaling / cleaning to flat plate, collector plate, solar heater water tanks, toughened solar glass panels, welding / breazing to solar tanks, Repair / rectification of leakage in inlet / outlet water tubing GI, checking and repair to electric system, Repair of water make up tank and make the system function cable after repair / servicing and rectification of the fault complete with and including replacement of minor spare parts complete all as specified and as directed. Note: - Spare shall be measured and paid separately.
Supply only union medium grade 25mm dia complete all as specified and as directed.
Supply only union medium grade 20mm dia complete all as specified and as directed.
Supply only rubber hose pipe with MS clamp of suitable size complete all as specified and as directed.
Supply only gun metal gate / globe valve 20mm dia complete all as specified and as directed.
Supply only rubber gasket of toughened glass complete all as specified and as directed.
Supply only painting to steel structure base frame complete all as specified and as directed.
Supply only float valve PVC 20 mm dia complete all as specified and as directed.
Supply only toughened glass panel suitable for 200 LPD solar water heater complete all as specified and as directed.
Material and labour for replacement of electrical heating element threaded type 3 KW, single phase suitable for solar water heater complete all as specified and as directed.
Material and labour for replacement of toughened collector glass of size 1.5 M X 1.0 Mtr complete all as specified and as directed confirming to ISI.
Material and labour for fasteners 80-100mm long for fixing of geyser of capacity upto 50 litres including grouting completed works in wall as per site requirement with the floor complete all as specified and as directed.
Supply and fixing in replacement chromium plated CP Bib cock 15mm dia conforming to ISI complete all as specified and as directed.
Supply and fixing in replacement gun metal glove / gate valve 15mm dia internal threaded with iron wheel head conforming to ISI complete all as specified and as directed.
Supply and fixing in replacement of unserviceable bolt 16mm dia X 6" long fully threaded with counted head nuts and washer heavy duty conforming to ISI for MS column pipe / CI flanged pipe complete all as specified and as directed.
Material and labour for replacement of tubing galvanised iron "medium grade" with all fittings laid in floor or trenches including taking out old unserviceable pipe of size 15mm dia complete all as specified and as directed.
Material and labour for fixing in replacement single pole and neutral enclosure with a two pin and earth plug and socket complete with one double pole MCB, fixing on wall suitable for geyser connection complete all as specified and as directed.
Material and labour for replacement water storage inner tank of stainless steel heavy duty confirming to ISI 25 litres capacity geyser with heating element assembly 1.5 KW triangular type, thermostat, indicators, 15mm dia galvanized air release valve, suitable to fix any type of water heating geyser of capacity 25 litres complete all as specified and as directed.
Material and labour for replacement outer shell suitable for 25 litres geyser made out of GI sheet heavy duty confirming to ISI , including new filling of glass wool and heat loss resist packing before inserting inner tank into outer tank, as suitable for existing make of geyser inner tank complete factory manufactured paint complete all as specified and as directed.
Material and labour for replacement of rotational moulded polyethylene water storage tanks of 1000 litre (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I.
Supply and fixing in replacement earthing test point terminal block made of gun metal or phosphorus bronze size 75 x 75 x 25mm drilled and screwed including 3 no's 8mm dia 25mm long hexagonal head screws complete all as specified and as directed.
Material and labour for replacement of unserviceable aluminium earth strip size 25 X 3 mm thick complete with replacement of mild steel saddle / clamp, fixing screws etc for roof conductor and down conductor above ground and on wall all as specified and directed.
Description same as per Ser Item No 161.00 here-in-before but 25 X 4 mm galvanized iron strip buried in ground and fixed on wall complete all as specified and as directed.
Supply and fixing in replacement of galvanized iron tubing light grade complete with fitting and fixed to wall / ceiling floor 40 mm dia complete all as specified and as directed.
Material and labour for replacement of Air termination single pointed aluminium rod 12 mm dia and 300 mm long complete all as specified and as directed.
Labour for repair to existing unserviceable / loose / hanging galvanized iron or aluminium earth strip fix on and around the RCC reservoir complete with and including mild steel saddle / clamps, nut bolt, screw as per site requirement and fix the strip properly with RCC reservoir wall complete all as specified and as directed. Note: - Rates are deemed to be including charges for hiring T&P and Life insurence of person deputed at site.
Material and labour for replacement of tubing galvanised iron "medium grade" with all fittings laid in floor or trenches including taking out old unserviceable pipe of size 20 mm dia complete all as specified and directed.
Material and labour for PCC (1:3:6) type C-2 (using 40 mm graded crushed stone aggregate) as in pole foundation, stay pits etc including provision of necessary form work to achieve fair finishes surfaces complete all as specified and directed.
Material and labour for replacement of lightening arrestors expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amps, 11000 Volts complete all as specified and as directed.
NOTE NO 1: - Samples of materials as approved will be kept in GE's sample room. NOTE NO 2: - All fittings and fixtures mentioned above will be fixed to the satisfaction of Engr-in-Charge and GE. NOTE NO 3: - Warranty certificate to the Engineer-in-Charge where ever applicable shall be submitted by the Contractor at the time of fittings.
M/S GAGAN ENGINEERS AND CONTRACTORS
vivek and co
Bidder Name
vivek and co
Sarbat Construction Co
M/S GAGAN ENGINEERS AND CONTRACTORS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .