SUPERINTENDING ENGINEER
SE, EDC-II, MOHADDIPUR, GORAKHPUR
WORK FOR SYSTEM AUGMENTATION / STRENGTHENING (ON SEMI TURNKEY BASIS) IN THE AREA OF ELECTRICITY DISTRIBUTION DIVISION-II, GORAKHPUR AGAINST BUSINESS PLAN SCHEME 2023-24.
2023_PVVNV_838792_1
34/EDC-II(G)/2023-24
Open Tender
Electrical Works
Lump-sum
90 days
SE, EDC-II, MOHADDIPUR
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
SE, EDC-II, MOHADDIPUR, GORAKHPUR
₹46,000
27 Jan 2024
16 Sept 2023
21 Sept 2023
16 Sept 2023
21 Sept 2023
16 Sept 2023
Amount
Hkkx&1 ifjorZd {kerko`f) dk dk;ZA 25 ds0oh0,0 ifjorZd ,oa mlls lEcfU/kr lkexzh ¼03 vnn ih0lh0lh0 iksy lfgr½ dh Hk.Mkj [k.M] xksj[kiqj ls dk;Z LFky rd lqjf{kr <qykbZ ¼p<+kbZ ,oa mrjkbZ lfgr½ dk dk;Z ¼nwjh 0 ls 80 fdeh0½A
10@16 ds0oh0,0 ifjorZd dh fMLesfUVfyax djds dk;Z LFky ls fo|qr Hk.Mkj dsUnz] xksj[kiqj rd lqjf{kr <qykbZ ¼p<+kbZ ,oa mrjkbZ lfgr½ dk dk;Z ¼nwjh 0 ls 80 fdeh0½A
25 ds0oh0,0 ifjorZd gsrq flaxy iksy ds LFkku ij Mcy iksy dk bjsD'ku djds 25 ds0oh0,0 ifjorZd dh leLr fQfVax ds lkFk ekmfVax djds ÅthZd`r djus dk dk;ZA
63 ds0oh0,0 ifjorZd ,oa mlls lEcfU/kr lkexzh dh Hk.Mkj [k.M] xksj[kiqj ls dk;Z LFky rd lqjf{kr <qykbZ ¼p<+kbZ ,oa mrjkbZ lfgr½ dk dk;Z ¼nwjh 0 ls 80 fdeh0½A
25 ds0oh0,0 ifjorZd dh Mcy iksy ls fMLesfUVfyax djds dk;Z LFky ls fo|qr Hk.Mkj dsUnz] xksj[kiqj rd lqjf{kr <qykbZ ¼p<+kbZ ,oa mrjkbZ lfgr½ dk dk;Z ¼nwjh 0 ls 80 fdeh0½A
63 ds0oh0,0 ifjorZd dh Mcy iksy ij leLr fQfVax ds lkFk ekmfVax djds ÅthZd`r djus dk dk;ZA
100 ds0oh0,0 ifjorZd ,oa mlls lEcfU/kr lkexzh dh Hk.Mkj [k.M] xksj[kiqj ls dk;Z LFky rd lqjf{kr <qykbZ ¼p<+kbZ ,oa mrjkbZ lfgr½ dk dk;Z ¼nwjh 0 ls 80 fdeh0½A
63 ds0oh0,0 ifjorZd dh Mcy iksy ls fMLesfUVfyax djds dk;Z LFky ls fo|qr Hk.Mkj dsUnz] xksj[kiqj rd lqjf{kr <qykbZ ¼p<+kbZ ,oa mrjkbZ lfgr½ dk dk;Z ¼nwjh 0 ls 80 fdeh0½A
100 ds0oh0,0 ifjorZd dh Mcy iksy ij ekmfVax djds izR;sd ifjorZd gsrq 4 vnn 240,e0,e0 dh ,Y;qfefu;e yXl lfgr ÅthZd`r djus dk dk;ZA
250 ds0oh0,0 ifjorZd ,oa mlls lEcfU/kr lkexzh dh Hk.Mkj [k.M] xksj[kiqj ls dk;Z LFky rd lqjf{kr <qykbZ ¼p<+kbZ ,oa mrjkbZ lfgr½ dk dk;Z ¼nwjh 0 ls 80 fdeh0½A
100 ds0oh0,0 ifjorZd dh Mcy iksy ls fMLesfUVfyax djds dk;Z LFky ls fo|qr Hk.Mkj dsUnz] xksj[kiqj rd lqjf{kr <qykbZ ¼p<+kbZ ,oa mrjkbZ lfgr½ dk dk;Z ¼nwjh 0 ls 80 fdeh0½A
250 ds0oh0,0 ifjorZd dh fIyaFk fuekZ.k dk dk;Z foHkkxh; fu;ekuqlkj lkexzh lfgrA
250 ds0oh0,0 ifjorZd dh fIyaFk ij ekmfVax djds izR;sd ifjorZd gsrq 4&4 vnn dkWij tsM DySEi ,oa ,Y;qfefu;e yXl lfgr leLr fQfVax ds lkFk ÅthZd`r djus dk dk;ZA
250 ds0oh0,0 ifjorZd dh Mcy dSfedy vfFkZax dk dk;Z leLr lkexzh lfgrA
250 ds0oh0,0 ifjorZd dh ukeZl ds vuqlkj QsfUlax dk dk;Z leLr lkexzh lfgrA
400 ds0oh0,0 ifjorZd ,oa mlls lEcfU/kr lkexzh dh Hk.Mkj [k.M] xksj[kiqj ls dk;Z LFky rd lqjf{kr <qykbZ ¼p<+kbZ ,oa mrjkbZ lfgr½ dk dk;Z ¼nwjh 0 ls 80 fdeh0½A
250 ds0oh0,0 ifjorZd dh fIyaFk ls leLr dusD'ku [kksydj fMLesfUVfyax djds dk;Z LFky ls fo|qr Hk.Mkj dsUnz] xksj[kiqj rd lqjf{kr <qykbZ ¼p<+kbZ ,oa mrjkbZ lfgr½ dk dk;Z ¼nwjh 0 ls 80 fdeh0½A
400 ds0oh0,0 ifjorZd dh fIyaFk fuekZ.k dk dk;Z foHkkxh; fu;ekuqlkj lkexzh lfgrA
Hkkx&2 vkj0,e0;w0 ;wfuV LFkkfir djus dk dk;ZA (A) Cartage of following materials from Store Center, Gorakhpur to work site with loading-unloading & proper stocking (distance about 0-80 Kms) (a) Cable Al. 3x185 sq.mm. XLPE 11 KV
(b) 11KV Indoor Cable Box for 3X185mm sq Cable
(B) Decentralised materials provided by Contractor at site. SF 6 SCADA compatible RMU 2 W ABB Make/Scinder Make/ C.G. Make or any reputed manufacturer.
SF 6 SCADA compatible RMU 3 WABB Make/Scinder Make/ C.G. Make or any reputed manufacturer.
GI Strip (40X6 mm)
16 Gauage GI Net between front & back (H-500 W-600 with Hole Dia 10mm and thickness of 1.5mm) in 25X25X3 mm angle frame with fasteners of required size for protection from Garbage
(C) Erection & Labour Charges. Erection of new plinth (2700 X 2000 X 1200mm) as per specifications
Fixing of RMU on plinth with complete fittings with Cable box.
Pipe in cage type earthing of RMU with material as per Specifications 3000 mm
Fixing of GI Strip with Electrode at One end & RMU on other end
Internal wiring of RMU with CT & Auxiliary
Erection of fencing with materials
Jointing of 11 KV Indoor cable Box with 3x185mm Sq. Cable
Fixing of Net with Fasteners in Angle Frame
Hkkx&3 f}rh; fcUnq vkiwfrZ ls lEcfU/kr dk;ZA izLrkfor ykbuksa ls lEcfU/kr lkekuksa dh fo|qr Hk.Mkj dsUnz ls dk;Z LFky rd lqjf{kr <qykbZ] yksfMax o vuyksfMax ds lkFk ¼nwjh 0&80 fd0eh0½ %& ¼v½ ih0lh0lh0 iksy
¼c½ ,l0Vh0 iksy
¼l½ vo'ks"k ykbZu lkexzh
fuEu {kerk ds ifjorZdksa dks LVksj lsUVj] xksj[kiqj ls dk;Z LFky rd lqjf{kr <qykbZ dk dk;Z %& ¼v½ 10 ds0oh0,0
¼c½ 63 ds0oh0,0
¼l½ 100 ds0oh0,0
lLisU'ku DySEi vkbZ gqd ds lkFk
MsM b.M DySEi
fMLVªhC;w'ku ckSDl gksfYMax DySEi uV cksYV ds lkFk
fofHkUu lkbt ds uV ,.M cksYV
dkWij ,y0 ihl 50x225
dkWij ,y0 ihl 67x225
,y0 ysx ihl
4 dksj ,y0Vh0 ,e0lh0ch0 ckWDl
MsUtj cksMZ ckCMZ ok;j
LVksu iSM
,Y;wfefu;e yXl 12,e0,e0
10 ds0oh0,0 Vh0,Q0 gksfYMax DySEi
leLr fQfVaax ds lkFk flfxay ih0lh0lh0 iksy dk bjsD'ku
leLr fQfVaax ds lkFk flfxay ,l0Vh0 iksy dk bjsD'ku
leLr fQfVax ds lkFk Mcy ih0lh0lh0 iksy dk bjsD'ku
,y0 Vh0 fo|qr midsUnz ls lEcfU/kr leLr fQfVax ds lkFk 11@0-04ds0oh0 ifjorZd dh ekmfVax%& ¼v½ 10 ds0oh0,0 flafxy iksy ij
¼c½ 63 ds0oh0,0 Mcy iksy ij
¼l½ 100 ds0oh0,0 Mcy iksy ij
VªkUlQkjej dh Mcy vfFkZx dk dk;Z
fMLVªhC;q'ku ckDl dh ekmafVx dk dk;Z
,l0Vh0 iksy dh fIyaFk fuekZ.k dk dk;ZA ¼lkexzh lfgr½
,l0Vh0 iksy dh isafVax dk dk;ZA ¼lkexzh lfgr½
Hkkx&4 {kfrxzLr oh0lh0ch0 cnyus dk dk;ZA 11 ds0oh0 vkmV budfeax@xksbax oh0lh0ch0 dh Hk.Mkj [k.M xksj[kiqj ls fo|qr forj.k [k.M&f}rh;] xksj[kiqj ds {ks=kUrxZr fofHkUu midsUnzksa ij <qykbZ dk dk;Z ¼p<+kbZ] mrjkbZ ,oa lqjf{kr j[kus lfgr½ nwjh 0 ls 80 fdeh0A
fofHkUu midsUnzksa ij LFkkfir 11 ds0oh0 budfeax@vkmV xksbax oh0lh0ch0 dh fMLesUVfyax djds midsUnz ifjlj esa lqjf{kr j[kus dk dk;ZA
fo|qr forj.k [k.M&f}rh;] xksj[kiqj ds {ks=kUrxZr fofHkUu midsUnzksa ij 11 ds0oh0 budfeax@vkmV xksbax oh0lh0ch0 dks iqjkuh oh0lh0ch0 clckj ds lkFk dkWij clckj LFkkfir djrs gq, ,ykbUes.V djds izkWij fQfVax djrs gq, iqjkuh vfFkZax ls tksM+us dk dk;ZA
fo|qr forj.k [k.M&f}rh;] xksj[kiqj ds {ks=kUrxZr fofHkUu midsUnzksa ij LFkkfir 11 ds0oh0 fMLesUVy budfeax@vkmV xksbax oh0lh0ch0 dks fo|qr midsUnz ls Hk.Mkj dsUnz xksj[kiqj rd lqjf{kr <qykbZ dk dk;Z ¼p<+kbZ] mrjkbZ ,oa lqjf{kr j[kus lfgr½ nwjh 0 ls 80 fdeh0A
Hkkx&5 ,fj;y cUp d.MDVj yxkus dk dk;ZA Loading, unloading and safe carriage of following materials from store center, Gorakhpur to work site with proper stacking (Distance about 0 to 80 Km) :- LT AB cable difference size as per Estimate
Laying, stringing, sagging, binding and jumpering of LT AB Cable difference size as per Estimate for LT Line with fixing of Suspension Clamp with I Hook (Insulated), dead end Clamp with I Hook (Insulated), Piercing Connector (Insulated) along with installation LT Three phas Distribution box with clamp and nuts & bolts off siz as per required
M/s Anil kumar singh
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .