Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹5.0 L
EMD Value
₹6,250
Closing Date
19 Oct 2025, 9:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Directorate of Municipal Administration
jyoti
Erection of Poles with LED Lights at Gokul main road near Neharu Nagar , Gandhi Nagar & other areas of Ward No.30 Hubli Division
DMA/2025-26/EL/WORK_INDENT43458/CALL-2
DMA/2025-26/EL/WORK_INDENT43458/CALL-2
Reserved
Electrical
Electronic Documents, First(One Cover)
DMA City Corporation Hubballi-Dharawada
8 documents required · 8 mandatory
₹500
₹6,250
9 Oct 2025
9 Oct 2025
14 Oct 2025
Erection of Poles with LED Lights at Gokul main road near Neharu Nagar , Gandhi Nagar & other areas of Ward No.30 Hubli Division
42.03) 3x95 + 1x70 + 1x16 Sqmm Street light (Insulated Messenger cum Neutral) 1.1 kV, LT Aerial Bunched Cable, XLPE insulation confirming to IS-14255: 1995
24.04 Stringing of 1.1 kV grade Aerial Bunched 3 Core cable of XLPE insulation of size (3x95) (Phase Conductor) + (1x70) (Insulated Messenger Neutral) + (1x25) (Street Light Control)
43.07 Single Phase Distribution Box for 20 Connection
66.04 HDPE/PLB Pipe 50/42 mm Optical Fibre Cable (OFC) and its
43.11 Piercing Connector Suitable for 16 Sqmm - 95 Sqmm AB Cable - Service Connection
43.12 Piercing Connector Suitable for 16 Sqmm - 95 Sqmm AB Cable - Street Light Connection
43.19 Suspension Clamp Assembly 16 to 70 Sqmm Bare Messenger (Exclusive of Pole Clamp and Eye Hook
43.35 pole clamp for HT/LT AB cable
43.36 Eye hook (flat type) for fixing clamps
43.16) Dead End Clamp/Anchor Clamp Assembly 25 to 95 Sqmm Bare Messenger(Exclusive of Pole Clamp and Eye Hook)
43.15 Universal Hook,bolt&nuts
24.10 Fixing of Universal Hook
24.29 T-connector KZ3 95
43.22) Pre - Insulated Lug - CPTAU for 95 Sqmm
43.33 End cap for 50/70sqmm
Guy Wire & GI Wire as per IS-2141
8.01 7/10 SWG Guy Wire (7/3.251 mm Dia), Std Wt: 680 Kg/KM
43.08 Single Phase Distribution Box for 10 Connection
1.1 KV Class HR (Heat Resistant) PVC Insulated & UnSheathed Aluminium Wires Multistrand Single Core Lead wires as per IS-694: 2010PVC Wire - 16 SqmmAl Wt: 4.2 Kg, Total Wt: 7.5 Kg/100 Mtr Coil
24.28 Distribution box suitable for 6, 3 Phase Connection
24.27 Distribution Box suitable for 20, Single Phase Connection
24.13) Installation of Insulation piercing connector for Main to Service Line Main : 16-95 Sqmm, Tap: 4-35 Sqmm (P2X95)
24.12 Installation of Insulation piercing connector for Main to Street Light Main : 16- 95 Sqmm, Tap: 1.5-10 Sqmm (EP95)
24.06 Erection of Suspension Clamp - 25 to 95 Sqmm bare messenger
24.11) Pole Clamp-145 mm x 95
25.02 Fixing of Dead End Clamp
24.29 fixing T-Connector KZ3 95
24.21 Installation of Pre-Insulated Lug - CPTAU for 95 Sqmm
Releasing of Conductor 7.04) Rabbit ACSR
5.02 Releasing of 4 Pin cross arm with Insulator and Braces fixing
Releasing of 6.03 1.1 kV Ceramic Pin Insulator (Shell only)
Releasing of 1.1kV6.07 No. 8 Strain Insulator
11.8.2 LED Streetlight 40W
Supply of LED Streetlight lumina ire with pressure die cast aluminum housing body for optimal thermal dissipation.Lamp compartment comprising of anti glare clear diffuser wi...
8.01 7/10 SWG Guy Wire,
(7/3.251 mm Dia), Std Wt: 680 Kg/KM
4.2.3 5 m - Top 70 mm and Bottom 130 mm diaFabricating,supplyinganderectionof.mslonghotdipGalvanizedOctagonalhotdipPolewithBSEN10025gradeS355JOsteelplateforshaft,IS2062forbaseplatewithdooropeningarran...
13.4.1) Single bracket 1.5 m. LengthSupplyingandfixingtelescopicM.S.bracketfabricatedbyusing0.5mlength4"diatelescopicM.S.pipe,with2"dia1.5mlongM.S.Bracketandareweldedwithsuitableangle,using6mmthickM.S...
1.17.1 All kinds of soils. Depth upto 1.50 m. Earth work excavation Dimension for Foundation (LBD) =(0.6mX0.4mX0.4m)*6=0.576Cum Earth work excavation for pipeline trenches in all kinds of soils by mec...
Base Concerete 2.1.1 Mix 1:5:10 Using 40 mm nominal size graded crushed coarse aggregates PCC Dimension =(0.4mX0.4mX0.1m)*6=0.096Cum Providing and laying in position Cement Concrete for levelling cour...
2.11 h. All other type of structures for TMT Steel TMT Bar Dimensions 1) 12mm Bars.8Nos i.e =8NosX0.7MeterX0.89Kg=4.98Kg 2) 8mm Bars.8Nos i.e =6NosX1.6MeterX0.395Kg=3.79Kg Supplying, fitting and placi...
Concerete 2.2.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RCC Dimension=0.35mX0.35mX0.7m=0.112Cum Providing and laying in Cement Concrete for all
Basement & surface leve...
1.4.1 In all kinds of soils Depth upto 1.5 m Earth work excavation for Foundation Dimension(LBD) =0.4mX0.4mX0.5m=0.08Cum Earth work excavation by manual means for drains, canals, waste weir, draft, ap...
32.02 10 Sqmm, 2 Core, (9 GI Strips - 4 x 0.8 mm) UG Cable Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVCextruded Inner sheath armoured UG LTcable as per IS-1554 (Part-1) or...
21.05) 2.5 to 25 Sqmm Labour Charges Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe / on wall / on pole as required.
SupplyinganddrawingFlexibleMulticoreCablemanufacturedwithelectrolyticgradeflexiblecopperwithlowconductorconfirmingtoIS81301984and(Virgin)PVCinsulationsheathedsuitableforworking vol...
5.18.1) 6-32 A SP MCB Switch Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 wit...
9 35.01 Up to 4C x 50 Sqmm Epoxy Terminating Kit (Pothead) suitable for 1.1 kV, LTUG Cable
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
43458.doc
Tender Document • 1.07 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .