| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹57,458.10Admitted-Finance EL 32 J BLOCK BHOSARI PUNE PUNE MAHARASHTRA 411026 | PUNE | MAHARASHTRA | 411026 | L1 | Admitted-Finance | |
| 2 | L2₹1.7 L+₹1.2 L (200.8%)Admitted-Finance IV 1064 INDUSTRIAL DEVELOPMENT AREA KANJIKODE PALAKKAD PALAKKAD KERALA 678623 | PALAKKAD | KERALA | 678623 | L2 | Admitted-Finance | |
| 3 | L3₹2.9 L+₹2.3 L (405.3%)Admitted-Finance G6 GEE GEE CRESCENT 114 POONAMALLEE HIGH ROAD CHENNAI TAMIL NADU 600084 | CHENNAI | TAMIL NADU | 600084 | L3 | Admitted-Finance | |
| 4 | Rejected-Technical | - | Rejected-Technical Not compalince the MII Order. |
| Sl No | Description | Qty | Unit | S. H. Pitkar Orthotools Pvt Ltd L1 | JAYON IMPLANTS PRIVATE LIMITED L2 | GESCO HEALTHCARE PRIVATE LIMITED L3 |
|---|---|---|---|---|---|---|
| 1.00 | Spine implants (construct unit)- 4 pedicle screws+2 connecting rods+ 1 cage + 1 connector - All the pedicle screws Should be made of medical grade titanium. | 1 | Mentioned in tender document | - | - | 20,047.65 ₹20,047.65 Lowest |
| 2.00 | Pedicle screws/ polyaxial /with set screw with tourque limit. | 1 | Mentioned in tender document | - | - | 2,415 ₹2,415 Lowest |
| 3.00 | Pedicle screws Monolock /polyaxial with set screw with tourque limit | 1 | Mentioned in tender document | - | - | 2,415 ₹2,415 Lowest |
| 4.00 | Pedicle screws Monolock/ polyaxial with set screw with tourque limit | 1 | Mentioned in tender document | - | - | 2,415 ₹2,415 Lowest |
| 5.00 | Connecting rod | 1 | Mentioned in tender document | - | - | 525 ₹525 Lowest |
| 6.00 | Top loading link/cross link connector | 1 | Mentioned in tender document | - | - | 4,987.5 ₹4,987.5 Lowest |
| 7.00 | TLIF/PLIF cage | 1 | Mentioned in tender document | - | - | 7,290.15 ₹7,290.15 Lowest |
| 8.00 | Carpectomy mesh - All sizes should be made of medical grade titanium. Mesh diameter should be 10 mm to 25 mm with increments of 1 mm in diameter. The length of the mesh should be 10 -100mm in increments of 5 mm. | 1 | Mentioned in tender document | 6,942.6 ₹6,942.6 Lowest | 9,450 ₹9,450 | 12,967.5 ₹12,967.5 |
| 9.00 | Carpectomy Expandable Mesh - All sizes | 1 | Mentioned in tender document | 23,415 ₹23,415 | 23,100 ₹23,100 | 10,500 ₹10,500 Lowest |
| 10.00 | MIS system unit- 4 MIS polyaxial screw + 2 connecting rods+ 1 PEEK TILIF cage | 1 | Mentioned in tender document | - | 29,400 ₹29,400 | 26,670 ₹26,670 Lowest |
Tender Value
Refer Docs
EMD Value
₹2 L
Closing Date
29 Nov 2022, 11:00 amClosed
Dean
ESIC Medical College Hospital K K Nagar Chennai
Supply of Orthopaedic Spine Implants under Rate Contract for ESIC Medical College Hospital K.K. Nagar Chennai 78 and ESIC ESIS Hospital Tamilnadu for two Years
2022_ESIC_719662_1
U-16042/2/2022-PURCHASE
Open Tender
Consumables (Hospital / Lab)
Item Rate
21 days
ESIC Medical College Hospital K K Nagar Chennai
As per tender terms and conditions
8 documents required · 8 mandatory
₹0
₹2 L
Yes
SM Chamber
14 Jan 2023
22 Oct 2022
30 Nov 2022
22 Oct 2022
29 Nov 2022
22 Oct 2022
28 Oct 2022
Spine implants (construct unit)- 4 pedicle screws+2 connecting rods+ 1 cage + 1 connector - All the pedicle screws Should be made of medical grade titanium.
Pedicle screws/ polyaxial /with set screw with tourque limit.
Pedicle screws Monolock /polyaxial with set screw with tourque limit
Pedicle screws Monolock/ polyaxial with set screw with tourque limit
Connecting rod
Top loading link/cross link connector
TLIF/PLIF cage
Carpectomy mesh - All sizes should be made of medical grade titanium. Mesh diameter should be 10 mm to 25 mm with increments of 1 mm in diameter. The length of the mesh should be 10 -100mm in increments of 5 mm.
Carpectomy Expandable Mesh - All sizes
MIS system unit- 4 MIS polyaxial screw + 2 connecting rods+ 1 PEEK TILIF cage
MIS Monolock/ Polyaxial screws
MIS connecting rod
PEEK TLIF cage.
Osteopolyaxial screw fenestrated set construct - Should be made of medical grade of titanium. Diameter from 5.5mm to 6.5mm in increments of 0. 5mm.Length of the screw should be from 30mm to 50mm in increments of 5 mm. The screws should be monolock, polyaxial, self-tapping screws. The screws should be supplied with cement plunger and appropriate cement and appropriate instrumentation. The price of each unit construct should include 4 screws, cement and plunger and two connecting rods of 50mm to 100mm ( implant to be purchased as a set)
Osteopolyaxial screw fenestrated
Connecting rods
Vertebroplasty cement with kit
Dual thread pedicle screws – The screws should be made of medical grade titanium. The screws should have variable pitch so as to provide better hold in osteoporotic bones. The diameter of the screw should be from 4.5 mm to 7.5 mm in increments of 1 mm. The length of the screw should be from 35mm to 50 mm in increments of 5 mm. The screws should be Monolock/poly axial self-tapping screws.
Cervical spine anterior plate interlocking system SET - One unit construct include ( 1 single level all sizes plate + 4 locking screws of all sizes +1 anterior cervical cage .The plate and screws should be made of medical grade titanium. The plate should be of low profile. Single level, two level and three level plate should be supplied. The locking screw should be self-tapping and self-drilling. The size of the locking screw should be 3.5mm/4 mm in diameter and length from 12 to 18 mm in increments of 2mm.The system should be supplied with appropriate instrumentation.
Single level/two level/three level plates all sizes
Locking screws all sizes
Anterior cervical cage (titanium)
Cervical standalone cage - Cage should have 2 screws. Cage size must be from 4mm to 12mm in increments of 1 mm. The cage should be 0 to 7 degrees. screw size 3.5mm/4mm diameter and length 12 to 18mm.self-drilling screws
Lateral mass fixation system set. Unit construct - 4 Screws+ 2 rods (94+94a) - The screws should be made of medical grade titanium. The screws should be self-tapping. The size of the locking screw should be 3.5 mm and 4 mm in diameter and length from 12 to 28 mm in increments of 2mm increment. The system should be supplied with appropriate instrumentation.
Rod for lateral mass screws
lateral mass screws
Distractable anterior space with plate - The cage should be made from medical grade titanium. The cage with plate system should be of size 12-18 mm expandable for a range from 20 to 60 mm. The system should be supplied with appropriate instrumentation
JAYON IMPLANTS PRIVATE LIMITED
GESCO HEALTHCARE PRIVATE LIMITED
JAYON IMPLANTS PRIVATE LIMITED
GESCO HEALTHCARE PRIVATE LIMITED
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .