Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.2 LAccepted-AOC 5 6 MINTO ROAD ALLAHABAD 211001 | PRAYAGRAJ | UTTAR PRADESH | 211001 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹40.7 L+₹46,411 (1.15%)Rejected-Finance SIDDHARTH CO 24 PADMAVATI SOCIETY VALLABH NAGAR BHURAVAV GODHRA GUJARAT 389001 | PANCH MAHALS | GUJARAT | 389001 | L2 | Rejected-Finance Other than being Lowest | |
| 3 | L3₹45.9 L+₹5.7 L (14.1%)Rejected-Finance B BLOCK 2 3 RAM BACHAN V B NAGAR PIPE ROAD KURLA W MUMBAI 400070 | MUMBAI SUBURBAN | MAHARASHTRA | 400070 | L3 | Rejected-Finance Other than being Lowest | |
| 4 | L4₹51.5 L+₹11.3 L (28.1%)Rejected-Finance | L4 | Rejected-Finance Other than being Lowest | |
| 5 | L5₹52.4 L+₹12.2 L (30.4%)Rejected-Finance GARDEN AVENUE PLOT NO 242 243 244 RH 4 SECTOR 21 NERUL NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L5 | Rejected-Finance Other than being Lowest |
Tender Value
Refer Docs
EMD Value
₹1.2 L
Closing Date
4 Jan 2023, 6:00 pmClosed
CWE (NW) Mumbai
Commander Works Engineer NW Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 05
CLEANING OF UG RESERVOIRS AND SERVICE TANK INCLUDING RENEWAL REPLACEMENT OF GATE VALVE SLUICE VALVE AND ITS ASSOCIATED ITEMS AT VARIOUS JETTIES AND WHARFS AT NAVAL DOCKYARD UNDER GE NW KUNJALI COLABA MUMBAI
2022_MES_566284_1
8524/CWE (NW) Mumbai/ E8
Open Tender
Civil Works
Item Rate
180 days
GE (NW) KUNJALI
Class C
7 documents required · 7 mandatory
₹1,000
Yes
GE (NW) Kunjali
₹1.2 L
Yes
4 Mar 2023
30 Nov 2022
6 Jan 2023
30 Nov 2022
4 Jan 2023
21 Dec 2022
30 Nov 2022 - 19 Dec 2022
Amount
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation/laying of pipe etc and getting out in hard dense soil complete all as specified and directed by Engineer-in-Charge.
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm deep as in soil complete all as specified and directed by Engineer-in-Charge.
Removing surplus excavated soil to a distance not exceeding 50 m and deposited where directed complete all as specified and directed by Engineer-in-Charge.
Material and labour brick masonary valve chamber of size 0.90 m x 0.90 m x 0.90 m (internal size) and MS cover including earth work complete all as specified and directed by Engineer-in-Charge comprising of the following.
150 mm thick PCC 1:4:8 type D2 using 40 mm graded stone aggregate for foundation complete all as specified and directed by Engineer-in-Charge.
Brick work 230 mm thick built in CM 1:4 complete all as specified and directed by Engineer-in-Charge.
15 mm thick rendering in CM(1:4) internally and externally to exposed surface of brick work including 150 mm below ground level complete all as specified and directed by Engineer-in-Charge.
100 mm thick coping in PCC 1:2:4 type B1 using 20 mm graded stone aggregate complete all as specified and directed by Engineer-in-Charge.
MS covers made out of 5 mm thick MS plate with double hinges, fixed MS angle iron frame made out of MS angle iron 40 x 40 x5 mm thick including 150 mm long hold fast made out of MS flat iron of size 25 x 4 mm embedded in PCC coping MS covers shall be provided with suitable hand grip and suitable locking arrangement complete all as specified and directed by Engineer-in-Charge.
All MS surfaces shall ,be painted with two coats of synthetic enamel paint over a coat of red oxide primercomplete all as specified and directed by Engineer-in-Charge.
All as per item No 4 above herein before but of size 0. 60 m x 0 .60m x 0.60 m Internal size complete all as specified and directed by Engineer-in-Charge.
Taking down old GI tubing 100/80 mm bore medium grade from trenches/wall/floor etc including making good the disturbed surfaces complete all as specified and directed by Engineer-in-Charge.
All as per item No. 6 above 50/40 mm bore GI tubing
All as per item No. 6 above 25 mm bore GI tubing
Supply and fix GI tubes medium grade of 100 mm dia complete with all fittings (like; union, tee, bend, elbow, reducer, socket) to be fixed on wall and ceilings or laid in floors/trenches complete all as specified and directed by Engineer-in-Charge
All as per item No. 9 above but of size 80 mm dia
All as per item No. 9 above but of size 50 mm dia
All as per item No. 9 above but of size 40 mm dia
All as per item No. 9 above but of size 25 mm dia
Taking down unserviceable gun metal globe or gate valve of any size from existing location complete all as specified and directed by Engineer-in-Charge.
Supply and fixing gun metal gate valve, with iron wheel head screwed both ends for iron pipe of 80 mm bore incl provn of union nipples sockets etc complete all as specified and directed by Engineer-in-Charge.
All as per item No.11 above but of 50 mm bore
All as per item No.11 above but of 40 mm bore
All as per item No 11 above but of 25 mm bore
All as per item No 11 above but of 20 mm bore
All as per item No 11 above but of 15 mm bore
Taking down old unserviceable float valve of any specification or any size complete all as specified and directed by Engineer-in-Charge.
Supply and fix ball brass high pressure with polythene float and fly nut of 50 mm dia complete screwed to iron or brass ferrule complete all as specified and directed by Engineer-in-Charge.
All as per item No. 18 above but of size 40 mm dia
All as per item No. 18 above but of size 25 mm dia
All as per item No. 18 above but of size 20 mm dia
All as per item No. 18 above but of size 15 mm dia
Taking down old unserviceable PVC tank and Supply and fix PVC moulded water storage tank of 2000 Ltrs capacity multilayered (ISI marked) cylindrical vertical type complete with inlet, outlet, overflow, and wash out connection, closed top cover complete including hoisting in position etc all as specified and directed by Engineer-in-Charge.
All as per item No. 23.00 above but capacity 5000 Ltrs
All as per item No. 23.00 above but capacity 3000 Ltrs
All as per item No. 23.00 above but capacity 10000 Ltrs
Supply and fix in repair cast iron cover 450mm dia BMC approved including locking arrangements/net fixed on PVC water tank/RCC water tank as in repair suitable for up to 15000 gallons capacity complete all as directed by the Engineer-in-Charge .
Supply and fix Brass foot valve heavy duty 50 mm/65 mm dia brass with all accessories complete all as directed by the Engineer-in-Charge .
All as per item No 28.00 above but 80 mm dia.
All as per item No. 28.00 above but 150 mm dia.
Material and labour for cleaning of underground sump by bailing out the remaining water after pumping by arranging re-watering pumps or manually and washing the walls & bottom surface by high pressure spray of approximately 195 PSI with rotary water jet pumps and removing the sludge and foreign matters complete and socking out the fixing with high pressure wet vacuum pumps scrubbing the wall and cleaning the entire sump including disinfectioning the tanks with spray of chemical approach by concerned authorities complete all as directed by the Engineer-in-Charge of following capacity :-
Upto 800000 ltr capacity
Upto 600000 ltr capacity
Upto 400000 ltr capacity
Upto 225000 ltr capacity
Upto 100000 ltr capacity
Upto 45000 ltr capacity of open well upto 70 ft depth with 18ft dia
All as per item No.31 above but RCC over head tanks on staging/terrace in any position of following capacity complete all as specified and directed by Engineer-in-Charge.
Capacity upto 10000 ltr
Capacity upto 5000 ltr
Capacity upto 2500 ltr
Cleaning of PVC tank in any position by rubbing, washing removing the scales dust etc including plugging the inlets dusting washing complete all as specified and directed by Engineer-in-Charge for tanks
Capacity from 500 TO 999 Ltrs
Capacity from 1000 TO 1999 Ltrs
Capacity from 2000 TO 4999 Ltrs
Capacity from 5000 TO 9999 Ltrs
Capacity from 10000 Ltrs and above
Supply & fix in repair hose Reel drum suitable for 30 mtrs X 20 mm dia rubber hose pipe complete all as specified and directed by Engineer-in-Charge.
Supply & fix in repairs Branch pipe gun metal 63mm instantaneous inlet, made of threaded outlet, 15mm bore nozzle complete all as specified and directed by Engineer-in-Charge.
Supply & fix in repair twin outlet hydrant valve 100mm having 65mm outlet with lock pin wheel complete all as specified and directed by Engineer-in-charge
Supply & fix in repair single outlet hydrant valve 100mm having 65mm outlet with lock pin wheel complete all as specified and directed by Engineer-in-charge
Supply & fix in repair gun metal Two way fire brigade inlet conection with adapter of size 80 mm dia X 63 mm dia complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of MS cover made out of 5 mm thick MS sheet with double hinges and suitable handle locking arrangement etc complete including two coats of synthetic enamel paint and one coat of primer all as complete and directed by Engr-in-Charge.
Material and labour for painting to WATER SUPPLY/ FIRE SUPPLY LINE tubing any dia after prepawation of old painted surface by proper cleaning and then applying ONE COAT OF RED OXIDE PRIMER AND two coat of synthetic enamelled paint as per existing colour code or as directed by Engineer-in-Charge
Material and labour for painting of MS ladder of different height and size in various locations removing old painted surface by proper cleaning and scraping then applying ONE COAT OF RED OXIDE PRIMER AND two coats of synthetic enamelled paint as per existing colour code or as directed by Engineer-in-Charge
Material and labour for painting to WATER SUPPLY/ FIRE SUPPLY LINE core points/ box/ pit chamber any dia after preparation of old painted surface by proper cleaning and then applying ONE COAT OF RED OXIDE PRIMER AND two coat of synthetic enamelled paint as per existing colour code or as directed by Engineer-in-Charge
Dismantling the damaged / unserviceable step ladder and design, fabricate supply fix / install step ladder made out of MS angle iron, solid iron/hollow rod/MS flats of suitable size with length as required as per site requirement and with the step gap of minimum 10 inch including welding , cutting, drilling etc matching grouting arrangement including making good to the disturbed surfaces and painting the step ladder with the two coats of synthetic enamelled paint over a coat of metal primer complete all as specified and directed by Engineer-in-Charge.
Demolition of PCC/ inter locking tiles/ Road cutting for laying of Pipe and making good after laying the Pipe with PCC 1:2:4 to match the existing surface up to and including 15cm in depth and n.exc 0.6m width complete all as specified and directed by Engineer-in-Charge.
Taking out old u/s Sluice valve with iron wheel head including all connected accessories of following sizes complete all as specified and directed by Engineer-in-Charge.
Supply and fix NRV valve (ISI Marked ) with iron wheel head, screwed both ends for iron pipe for following sizes complete all as specified and directed by Engr-in-Charge
Supply and fix in repair Direct-on-Line Starters 7.5 HP, 3-Ph motor complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair Direct-on-Line Starters 10 HP, 3-Ph motor complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair Fully automatic SD starter 15 HP, 3-Ph motor complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair Fully automatic SD Starters 30 HP, 3-Ph motor complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair Soft Starters 200 HP, 3-Ph motor complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing in repair sluice valves flanged end, cast iron body, flanged and drilled and non rising type brass spindle with nut, long body, class P N 16, conforming to IS 14846 of 2000 for following sizes including all flange joint with rubber or fiber board, bolts, nuts and washers complete including pumping out accumulated water all as specified and directed of and of following size complete all as specified and directed Engineer-in-Charge.
300 mm bore
250mm bore
200 mm bore
150 mm bore
100 mm bore
80 mm bore
50 mm bore
Supply, lay/fix, connect and testing MS ERW pipe, in any length, including supply and fixing all fittings, ISI marked conforming to IS-1239 and fixed to wall/ceiling or laid in trenches/floors complete all as specified and directed by Engineer-in-Charge.
300 mm bore
200 mm bore
250 mm bore
150 mm bore
siddharth and company
Genius Construction Co.
shubham construction
M/s S.D Construction Co
SHRI SAI ENTERPRISES
Shree Ayyappa Engineering
Vandan Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .