Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance 0000 UNNAMED ROAD GAJIYA KANTIT VINDHYACHAL MIRZAPUR UTTAR PRADESH 231307 | MIRZAPUR | UTTAR PRADESH | 231307 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance H NO 21666 POWER HOUSE ROAD STREET NO 9 BATHINDA PB 151001 | BATHINDA | PUNJAB | 151001 | Admitted-Finance |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
24 Jun 2020, 6:00 pmClosed
GE KAPURTHALA
GE KAPURTHALA
Repair/Replacement of Water Supply line, all type of pump set, DG Set, fire fighting system and other allied works at Mil Station Suranussi under GE Kapurthala
2020_MES_346857_1
GE KPT-07/2020-21
Open Tender
Civil Works
Item Rate
270 days
KAPURTHALA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE KAPURTHALA
₹80,000
Yes
26 Jun 2020
25 May 2020
26 Jun 2020
25 May 2020
24 Jun 2020
8 Jun 2020
Amount
Excavation in trenches in soft/loose soil not exceeding 1.50 mtr wide and not exceeding 1.50 mtr in depth for laying CI/GI pipe lines and under ground cables including segragation of sand, bricks and stacking compete all as specified and directed by Engineer-in-Charge.
Returing, filling in, including spreading, leveling watering and well ramming inlayers not exceeding 25 cms thick each layer compete all as specified and directed by Engineer-in-Charge.
Removal of surplus spoil to a distance not exceeding 50 mtr away and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-charge.
Taking up or down CI /GI tubing along with connections and fittings and keeping in safe coustody the serviceable items for reuse and removal of unserviceable items from site of work for following size :-
(a) 150mm bore
(b) 100 mm bore
(c) 80 mm bore
(d) 50 mm bore
(e) 40 mm bore
(f) 25 mm bore
Relaying only CI/GI pipes any grade in trenches removed from Sl item No.4
(a) 150mm bore
(b) 100 mm bore
(c) 80 mm bore
(d) 50 mm bore
(e) 40 mm bore
(f) 25 mm bore
Supply and lay in trenches DI pipe with all fittings (fittings shall be measured & paid seperately) complete for following size :-
(a) 150mm mm bore
(b) 100mm mm bore
(c) 80mm mm bore
Supply and lay in trenches medium grade steel water tubing galvanised with all fittings complete for following size :-
(a) 50 mm bore
(b) 40 mm bore
(c) 25 mm bore
(d) 20 mm bore
Supply and fixing in cast iron sluice valve PN 1.6, 150 mm bore with flanged ends ISI mark with Gun metal spindle CI gate with brass ring and iron wheel handle with jointing material such as nuts /bolts washers and rubber insertion sheet etc including taking out old U/S sluice valve complete all as specified.
All as per item ser No 8 above here in before but 100 mm bore
All as per item ser No 8 above here in before but 80 mm bore
M&L for lead joint suitable for CI pipe 150 mm bore complete all as specified.
All as per item ser No 11 above here in before but 100 mm bore
All as per item ser No 11 above here in before but 80 mm bore
M &L required for earth work in trenches / pit and bailing out water to rectifying leaking joint of CI pipe spigot and socket type 150 mm bore as required including refilling and levelling the excavated material after rectifying the leakage complete all as specified.
All as per item ser No 14 above here in before but 100 mm bore
All as per item ser No 14 above here in before but 80 mm bore
M & L cutting of existing CI pipe lines and connecting with new laid CI pipe line 150 mm bore complete including dewatering & excavation all as specified. ( Note - CI fitting and lead joint shall be measured and paid for separtely)
All as per item No 17 here in before but 100 mm bore
Repair to existing valve pits of any size & location all as specified and as directed by Engineer-in-Charge.
(a) M&L for brick work using sub class 'B' (old size bricks) in CM 1:4
(b) M&L for rendering 15mm thick in CM 1:4 finishing even and fair
(c) M&L for PCC 1:2:4 type B-O (using 12.5mm graded stone aggregates) as in coping
(d) M&L for any type of mild steel work such as frame,, sheet 3mm thick including welding, cutting & fixing in position
Supply and fixing glass sheet size 60 cms x 60 cm x 4 mm thick in MS box including fixing with beading for putting complete all as speicified and directed by Engr in - charge (Beading if required shall be measured and paid separterly )
Supply and fixing sheet metal fire box 16 gauge of size cover all size 75 x 75 x 20 cms thick welded to MS angle iron frame of size 40 x 40 x 6 mm and legs (02 Nos ) welded to angle iron frame at one end of other embaded in cement concrete (1:2:4 ) type B-1 block size 45 x 45 x 45 cms including mounting 'L' type hook for supporting hose pipe including Plastic sheet 60 x60 cm x 4 mm thick fixed to steel frame as indoor covering fixed with 100 mm long medium weight butt hindges (02 Nos ) and painting with two coats of synthetic enameled paint over a coat of red oxide primer writing letter "Box for hose Pipe " with white paint including taking out old unserviceable box complete all as specified and as directed by Engr-in-charge.
Supply and fixing in replacement gun metal brass coupling out let for fire hydrant suitable for coupling to hose pipe 70 mm dia including taking out unserviceable coupling complete all as specified and as directed by Engr-in-charge.
Supply and fixing hose pipe rubberised fiber 70 mm dia ISI marked each length 30 Mtr with gun metal male and female coupling duly winding with wire suitable for fire hydrant 65 mm bore including taking out old unserviceable hose pipe complete all as specified and as directed by Engr -in-charge (Make Padmini ISI Marked )
Supply & fixing fire hydrant stand post 100 mm bore made out of cast iron complete suitable for fixing cast iron bush both end threaded 65 mm bore.
Material and Labour for dismantling the suction and delivery line from the defective centrifugal pumping set of any make i.e pump and motor. Transporting pumping set to work shop, dismantling pumping set and taking out defective wornout parts i.e MS Gland, shaft key, Gun metal shaft, sleeve, ball bearing, locking nuts, Impeller, MS shaft, CI coupling etc, cleaning the casing with wire brush and washing with water, repairing the pump set, replacing defective wornout parts assembling to its original form and bringing back to site of work complete, reconnecting suction, delivery pipe line and couple with electric motor testing for satisfactory running and continuous flow of water complete all as directed by Engineer-in-charge for the following capacities:-
(a) 100HP Capacity
(b) 75 HP Capacity
(c) 20/25 HP Capacity (Jockey Pump)
Supply only orthotolidine reagenet for chlorine test in 500 ml bottle of make - glaxo / SDS / Ran baxy
Disconnecting the electric connection of the defective electric motor of any make from panel board, starter, dismentling from centrifugal pumping set, Transporting to work shop and dismantling motor, taking out burnt copper winding of stator, cleaning the casing of stator with wire brush, repair to rotor by turning, polishing and truing, rewinding the motor using super enameled insulated copper wire of existing gauge varnishing, drying complete, re-assembling the motor to its original form after replacement of defective ball bearing of existing size - 02 Nos, bringing back to site of work, recoupling with centrifugal pump set, reconnecting the electrical connection one testing on load for satisfactory running all as directed by Engineer-in-charge for following capacity of motors :-
(a) 100 HP Capacity
(b) 75 HP Capacity
(c) 20/25 HP Capacity (Jockey Pump)
Taking down old unserviceable panel and Supply, install, testing and commissioning of Star Delta starter panel capacity 35 HP panel size 80 cm x 60 cm x 40 cm enclosures cubical weather and vermin proof totally enclosed made out of 2mm thick CRCA sheet machine pressed of suitable size to operate on 3 phase 4 wire system 415 Volts, 50HZ double door with front openable with locking arrangement including inner shutters for mounting switch gear etc, bottom gland plate with sufficient numbers of circular cable entry holes, including PCC 1:3:6 if foundation & coping at site work, prewired complete duly powder coated with comprising of the following :-
INCOMING (i) MCCB 100 Amps FP, 415 Volt 25 KA adjustable thermal & adjustable magnetic setting Ics = 100%Icu = 01 No of Make : Schneider-CVS /Legrand Dpx3/Siemens-3VA.
(ii) On load Change over switch 63 Amp in open execution Cat part No INAE0063 of make Indoasian or equivalent in HPL/L&T
(iii) Power contractor 3 pole 50 Amp (AC 3 duty) AC control different level of power and control contacts, inbuilt 1 No + 1 NC auxillary contacts Cat part No LC 1D50A* of make : Schenieder or equivalent in Legrand
(iv) Thermal overload relay D model cap 30 - 40 Amp with thermal protection Adjustable range cat part No LRD3355 of Schenieder or equivalent in Legrand
(v) CT coil capacity 100/5 ratio sutaible for 3 phase supply make : AE or equivalent
(vi) Single phase preventor system supply 415 volts, 50 Hz VSP3 of Make : minilec or equivalent
(vii) Capacitor box type standard duty box 3 Ph 10 KVAr 440 V 50 Hz - 01 No Make : Scheneider/Legrand
(viii) Control MCB SP 2 Amp for control - 02 Nos Make : Scheneider/Legrand
(ix) Start- stop illuminated push button red and green colour cat part No for Red XB5AW31M1N and Green Cat part No XB5AW13M1N of Make Schenieder or equivalent
(xii) Phase indicating lamp LED (R,Y,B) type with MCB SP 6 Amp – 1 Set of three.
(xiii) ON/OFF indicating lamp on incomer feeder for status of feeder = 02 Nos
(xiv) Copper bus bar 200 Amps capacitor of suitable length insulated heavy heat shrinkable sleeves etc -04 Nos.
(xv) Single phase starter suitable for bleaching/sodium hypochloride dozing pump. Make : Scheinder/BCH
Attending complaints by deploying sufficient labour (Skilled and helpers) for repair to leakage/blockage of underground water carrying pipes, size 40 to 225 mm bore of any description such as AC/GI/CI/DI, at any location including necessary excavation & earth work, cutting existing pipe lines, dewatering etc complete all as specified.
NOTE:- (i) Complaint shall be notified to contractor on telephone, therefore it is mandatory for the contractor to mention his ‘Mobile Number’ while quoting the tender and also give mobile number to Engineer-in-Charge before commencement of work.
(ii) Complaint shall be notified to contractor at any time between 0600 hrs to 2000 hrs and the same shall be immediately attended and defects rectified within six hrs from notification of complaint to the contractor.
(iii) Confirmation of attendance & rectification of complaint shall be given in writing by the contractor and same shall be recorded in the ‘Register’ maintained for the purpose. The ‘Register’ shall be produced to GE on demand.
(iv) In case the contractor fails to attend complaints within stipulated time (i.e. 6 hrs), a penalty shall be imposed @ Rs 300/- per complaint.
(v) Rates quoted by the contractor shall be deemed included the cost of necessary T& P required.
(vi) Pipes and cost of jointing shall be measured and paid separately under respective items.
Supply and fixing On load change over switch front handle operated 400 Amp open execution Four pole 415 volt. equivelent make Standard/L&T/Indo Asian
M&L for replacement on load change over rotery type 4 pole 415 volt 200 Amp
All as per ser item No 31 here in - before but 100 Amp
S&F in replacement MCCB 350 Amp 4 pole 36 KA 415 Volt complete all as specified and directed.
S&F in replacement MCCB 200 Amp 4 pole 36 KA 415 Volt complete all as specified and directed.
S&F in replacement MCCB 160 Amp 4 pole 36 KA 415 Volt complete all as specified and directed.
Supply & Fixing in repair cast iron fitting such as bend ,any type radius and angle taper any type straight, bends, increasing decreasing tee pieces, single branch,Y junction, coller ,cap and plug with spigot/socket end flange upto 150 mm bore including taking out old material all as directed
M&L for disconnecting electric connection and pipe connection and taking out subermisible pump & motor of capacity 25 to 35 HP from bore well and taking to workshop for repair and removal of burnt winding wire from motor and rewinding with new PVC insulated copper winding wire for submersible motor of same gauge and weight to existing including replacement of motor bush, thrust plate coupling complete with key and reassembling the motor with pump and taking back to site, lowering it into bore well making it functional and testing complete all as specified.
All as per ser item No 37 here in-before but 15 to 20 HP
Repair/replacement of unserviceable part of submersible pump capacity 25 to 30 HP such as gun metal bush impellor assembly shaft locking key and MS nuts & bolts of existing size and reassembling the pump with motor and making it functional all as specified.
All as per ser item No. 39 here n before but 15 to 20 HP
M&L for cleaning and flushing of RCC over head reservoir of capacity 50000 gallons at 70 feet staging removing of silt and suldge to a distance not exceeding 50 mtr from GP etc deposited inside the tank cleaning entire internal surface of tank with bleaching powder and flushing with water complete all as specified including on RCC suface " Tank cleaned on __________" with synthetic enamelled paint.
All as per ser item No 41 here in-before but semi under ground tank of capacity 100000 gallon
All as per ser item No 41 here in-before but semi under ground tank of capacity 50000 gallon
M&L for replacement of existing cast iron double aire release valve of size 80mm bore replacement of worn out bolts, nuts, gaskets if any complete all as specified and directed
Supply and fixing rubber beeding of suprior quality suitable for fixing sheet glass 60x60x4mm thick in MS box for hose pipe including taking out old & unserviceable beeding all as specified
Supply and fix contractor ML-2 with 220 Volt coil. AC-03 rating 32 Amp 440 Volt parts No SS90701 complete all as specified and directed. Make :- L &T co
All as per item No.46 herein before but with 415 Volt coil
Supply only battery 12 volts 180AH Make Excide ,Lumminus.
Supply & Fix in replacement Water Pressure gauge 4'' dial 1-14 KGS RATING Make Uday
Supply and fix in replacment of gun metal globe or gate valve with iron wheel head screwed both ends suitable for galvanised pipe 20 mm bore complete all as specified.
All as per item ser No 50 above here in before but 25 mm bore
All as per item ser No 50 above here in before but 40 mm bore
All as per item ser No 50 above here in before but 50 mm bore
Supply and Fix in replacement Pressure switch Universal type
Supply and Fix in replacement Flanged stand post CI 80 mm dia 1.5 mtr height
Supply and Fix in replacement Non return sluice valves 50 mm
Supply and Fix in replacement Non return butterfly valves 150 mm
Supply and Fix in replacement Non return butterfly valves 100 mm
Supply and Fix in replacement Non return butterfly valves 80 mm
Supply & Fixing PVC insulated submersible cable 03 core 1100 Volt AC Supply stranded copper conductor of size 10 sqmm in replacement of old unserviceable cable Make : Rallison / Plaza/Fenolax.
S&F GI coloumn pipe 100mm dia heavy duty 'C' class with flanged ends drill 3 meter including joining to existing main pipe line complete all as specified and directed (the cost of nuts bolts washers packing materials and pressure gauge shall be deemed to include in unit rate quoted by the contracror.
Supply only Calcium based granuler disinfect suitable for treatment drinking water in 45 kg plastic drum complete all sa specified and directed Make: Aquafit
DUGGAL CONSTRUCTION CO
SUNRISE ENGINEERS AND CONTRACTOR
R K ENTERPRISES
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .