Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.2 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹23.6 L+₹34,566 (1.49%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹24.0 L+₹74,714 (3.22%)Admitted-Finance | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/S Shukla Traders L3 | M/S SUBHASH TRADERS L2 | Shre Bala Jee Enterprises L1 |
|---|---|---|---|---|---|---|
| 1.00CARTAGE OF STORE ITEMS FORM ESC, RAEBARELI TO DUMP SITE AND WORK SITES ALONG WITH LOADING, UN-LOADING AND PROPER STACKING | ||||||
| 1.01 | loose line material ABC 3X95 AND ACSR CONDUCTOR INCLUDING 11KV PIN INSULATOR WITH PIN,11KV DISC FITTING 45KN, 11KV INSULATOR 45KN, TOP CHHANEL, M.S. T-OFF CHANEL, STAY COMPLETE, S/S BASE ANGAL, EARTHING COMPLETE, G.I. WIRE 6SWG, M.S. DROPER ANGAL, M.S. GUARDING ANGAL etc. | 12 | Job | 3,605 ₹43,260 | 3,630 ₹43,560 | 3,550 ₹42,600 Lowest |
| 1.02 | 8.5 Mtr long PCC Poles | 38 | Nos | 900 ₹34,200 Lowest | 980 ₹37,240 | 905 ₹34,390 |
| 1.03 | Cortage of New 63KVA T/F | 1 | Nos | 2,550 ₹2,550 | 2,700 ₹2,700 | 2,500 ₹2,500 Lowest |
| 1.04 | Cortage of New 100KVA T/F | 3 | Nos | 3,550 ₹10,650 | 3,200 ₹9,600 Lowest | 3,500 ₹10,500 |
| 1.05 | Cortage of New 250KVA T/F | 8 | Nos | 4,550 ₹36,400 | 4,870 ₹38,960 | 4,500 ₹36,000 Lowest |
| 2.00ERRECTION | ||||||
| 2.01 | Errection of D/P by PCC Pole 8.5 Mtr. including digging of Pits & fitting of All accessories. | 12 | Nos | 4,530 ₹54,360 | 3,000 ₹36,000 Lowest | 4,500 ₹54,000 |
| 2.02 | Errection of PCC Pole 8.5 Mtr. including digging of Pits & fitting of All accessories. | 14 | Nos | 995 ₹13,930 Lowest | 1,150 ₹16,100 | 1,050 ₹14,700 |
| 2.03 | Digging of pits, fixing nozzling & grouting of stay rods as per RESSPO norms including grouting materials. | 24 | Nos | 840 ₹20,160 | 790 ₹18,960 Lowest | 815 ₹19,560 |
Tender Value
₹23.5 L
EMD Value
₹24,000
Closing Date
12 Sept 2025, 4:00 pmClosed
SE EDC-I RAEBARELI
SE EDC-I RAEBARELI
WORK MENSION IN BOQ (BP 2025-26)
2025_MVVNL_1068855_1
43/EDC-I,R/2025-26
Open Tender
Electrical Works
Item Wise
30 days
UNDER EDD RAEBARELI
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
EXECUTIVE ENGINEER C AND MC
₹24,000
22 Sept 2025
29 Aug 2025
13 Sept 2025
29 Aug 2025
12 Sept 2025
29 Aug 2025
Amount
CARTAGE OF STORE ITEMS FORM ESC, RAEBARELI TO DUMP SITE AND WORK SITES ALONG WITH LOADING, UN-LOADING AND PROPER STACKING
loose line material ABC 3X95 AND ACSR CONDUCTOR INCLUDING 11KV PIN INSULATOR WITH PIN,11KV DISC FITTING 45KN, 11KV INSULATOR 45KN, TOP CHHANEL, M.S. T-OFF CHANEL, STAY COMPLETE, S/S BASE ANGAL, EARTHING COMPLETE, G.I. WIRE 6SWG, M.S. DROPER ANGAL, M.S. GUARDING ANGAL etc.
8.5 Mtr long PCC Poles
Cortage of New 63KVA T/F
Cortage of New 100KVA T/F
Cortage of New 250KVA T/F
ERRECTION
Errection of D/P by PCC Pole 8.5 Mtr. including digging of Pits & fitting of All accessories.
Errection of PCC Pole 8.5 Mtr. including digging of Pits & fitting of All accessories.
Digging of pits, fixing nozzling & grouting of stay rods as per RESSPO norms including grouting materials.
Grouting of Poles as per RESSPO norms with grouting materials.
Mounting of New 250 KVA T/F on Plinth
Mounting of New 100 KVA T/F on DP
Mounting of New 63 KVA T/F on DP
EARTHING OF POLES/DT AS PER RESPO NORMS
INSTALLATION OF TPMO AND 11 KV FUSE SET AS PER NORMS
Construction of Plinth size 1.5X1.5x1.5 Mtr. alongwith 0.5Mtr. foundation of first class brick and brick blast also proper ratio of cement and red sand. Complete in all respect as per RESSPO norms.
Fabrication of wiremesh fencing of Distribution T/F of size 2.5x2.5x2Mtr. By M.S angle of size 35x35x5mm and MS flat of size 25x5 mm with wiremesh and grouting of the grouted with grouting material. Complete in all respect as per RESSPO Norms.
Digging of 1X60 feet deep boring type neutral and body of distribution 63/100 KVA T/F at different places and welding of G.I strip including the cost of M.S. pipe 1.25 Inch dia, 1*40 feet long and MS strip 25*3 mm of suitable length for connecting M.S pipe to neutral through proper welding or bolt and nut. All material, consumables and T&P will be privided by contractor.
Laying of ABC cable of size (3X95)mm2.complete in all respect as per norms
Stringing of ACSR conductor ,complete in all respect as per norms
INSTALLATION OF LT incoming panel with metering equipment & fixing arrangement (LS)
INSTALLATION OF 4 core LT MCB with box (LS)
INSTALLATION OF LT Distribution box
Fixing of Copper L-piece suitable for 63/100/250 KVA Transformer of size 125X75X50X6 mm made of electrolite Copper strip (99.9% Purity) with required size (240/400 Sq. mm) Alluminium Crimping Lugs (99.9% Pure A-grade Alluminium). (All the material will be arranged by the contractor).
Material Provided by the contractor
STAY ISULATOR
NUT AND BOLT OFF SIZE
X-ARM HOLDING CLAMP
F BRACKET
Stone pad 300x300x75mm
Clamps for LT T-off with bolts & Nuts
Holding clamps for top channel TPMO & fuse set etc. with bolts & nuts
11 KV TPMO
11 KV fuse Set
LT incoming panel with metering equipment & fixing arrangement (LS)
Copper L-piece 62x225x12 mm (LS)
LT PVC Cable Al 3.5x400 sq mm
LT PVC Cable Al 1x400 sq mm
LT PVC Cable 3.5X150/70 sq mm
LT PVC Cable 3.5X70/35 sq mm
Al Leg long barrel off size (LS)
4 core LT MCB with box (LS)
LT Distribution box
LT Piercing connector 95 Sq.mm
Connecting lead 1x16 Sq mm
Danger baord Barbed wire including jumper
Concreting of poles
Red oxide paint
Aluminium paint
Plinth for size 2x2x1.5M
Suspension clamp with I hook
Dead end clamp with I hook
Fencing Of DT
M/S SUBHASH TRADERS (BID ID -5529050)
M/S Shukla Traders (BID ID -5527961)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .