Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.7 LAccepted-AOC NO 12 5TH B CROSS SHARADAMBA NAGAR M E S ROAD BANGALORE 560013 | BANGALORE | BANGALORE | KARNATAKA | 560013 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹11.4 L+₹1.4 L (14.0%)Rejected-Finance NO 83 THAMMAIAH GARDEN ABBIGERE CHIKKABANAVARA PO BANGALORE 560 090 | BENGALURU URBAN | KARNATAKA | 560090 | L2 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
Tender Value
Refer Docs
EMD Value
₹29,000
Closing Date
31 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer M AF Jalahalli
Garrison Engineer M AF Jalahalli BANGALORE 560013
8538E8REPAIRS AND MAINTENCE OF LT DISTRIBUTION SYSTEM IN TECHNICAL AREA AND OTM OF AFTC JALAHALLI UNDER AGE E/M WEST OF GE M AF JALAHALLI BANGALORE
2020_MES_400708_1
8538E8
Open Tender
Electrical and Maintenance Works
Item Rate
303 days
JAJAHALLI
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Garrison Engineer M AF Jalahalli
₹29,000
4 Mar 2021
4 Dec 2020
2 Jan 2021
4 Dec 2020
31 Dec 2020
19 Dec 2020
4 Dec 2020 - 10 Dec 2020
60 days
Amount
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable, foundation etc, and getting out in hard /dense soil all as directed.
Excavating in trenches not exceeding 1.5m wide and exceeding 1.5m in but not exceeding 3.0m depth for laying of cable, pole,foundation etc, and getting out in hard /dense soil all as directed.
Returning filling in including spreading, leveling Watering and well ramming in layers not exceeding 25cm all as directed.
Removing excavated surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as directed.
Supply and spread fine river sand in trenches, as in cable cushioning all as directed. Note :- Punned thickness will be considered for payment.
Material and labour for plain cement concrete 1:4:8 type D2 using 40 mm graded stone aggregate for foundations / filling around the post all as specified and as directed.
Material and labour for plain cement concrete 1:3:6 type C1 using 20 mm graded stone aggregate for path ways, hard standing & pole coping including necessary form work and applying two coats of white wash on exposed surfaces etc complete all as specified and as directed.
Material and labour for Cutting PCC / road 100 mm thick for laying of LT UG cable and making good the disturbed surfaces with cement concrete 1:2:4, type B-1, using 20mm graded stone aggregate complete all as specified and directed.
Boring of holes under road, pavement and hard standing by trenchless method by adopting horizontal boring using ultra sound technique and necessary machine including supply and insection of HDPE pipe 150 mm dia suitable for 0.4 Mpa working pressure confirming to IS specified and as directed. Note:- Depth will not be less than 2m below the road, pavement and hard standing without damaging the road, pavement and hard standing.
Material and labour for pin type, porcelain vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut 100mm height, 65mm dia for 1100 volts grade all as specified and as directed.
Material and labour for shackle type, porcelain vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts,nuts,100mm height, 115mm dia for 1100 volts grade all as specified and as directed.
Dismantling insulators of any type and size all as directed.
Supply & Erecting in replacement of Mild steel tubular swaged poles of 9.0 meter long 410, SP-31 complete with cast iron base plate, bracket, finial taper plug, bolt, nuts & screws and painted on both side (internally & externally), external surface painted with two coat of aluminum paint over coat of red oxide primer and painting with black upto 1.5 meter from top of PCC coping white colour paint as in strips of equal width including marking pole numbers with one coat of synthetic enamel paint complete all as specified and as directed.
Material and labour in replacement of cross arms,bracings,supports,clamps and back plates fabricated from structural steel sections including nuts,bolts,washers,welding,bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed by Engr-in-Charge..
Cutting and cleaning of fallen down trees and branches of any size from the LT over head lines by using required machinery/cutting equipments and disposing to a distance not less than 50 metres and restoring electric supply including jointing the ACSR conductors if required complete all as specified and directed by Engr-in-Charge.
Supply, laying, jointing & testing, XLPE insulated, armoured, heavy duty electric LT UG cable with multi stranded aluminium conductor, 1100 volts grade laid in trenches or in duct/passed through pipes or fixed to wall/poles etc cross sectional area of sizes 240 sqmm 3.5core including taking down of unserviceable cable complete all as specified and directed.
Supply, laying, jointing & testing, XLPE insulated, armoured, heavy duty electric LT UG cable with multi stranded aluminium conductor, 1100 volts grade laid in trenches or in duct/passed through pipes or fixed to wall/poles etc cross sectional area of sizes 185 sqmm 3.5core including taking down of unserviceable cable complete all as specified and directed.
Supply, laying, jointing & testing, XLPE insulated, armoured, heavy duty electric LT UG cable with multi stranded aluminium conductor, 1100 volts grade laid in trenches or in duct/passed through pipes or fixed to wall/poles etc cross sectional area of sizes 120 sqmm 3.5core including taking down of unserviceable cable complete all as specified and directed.
Supply, laying, jointing & testing, XLPE insulated, armoured, heavy duty electric LT UG cable with multi stranded aluminium conductor, 1100 volts grade laid in trenches or in duct/passed through pipes or fixed to wall/poles etc cross sectional area of sizes 95 sqmm 3.5core including taking down of unserviceable cable complete all as specified and directed.
Supply, laying, jointing & testing, XLPE insulated, armoured, heavy duty electric LT UG cable with multi stranded aluminium conductor, 1100 volts grade laid in trenches or in duct/passed through pipes or fixed to wall/poles etc cross sectional area of sizes 70 sqmm 3.5core including taking down of unserviceable cable complete all as specified and directed.
Supply, laying, jointing & testing, XLPE insulated, armoured, heavy duty electric LT UG cable with multi stranded aluminium conductor, 1100 volts grade laid in trenches or in duct/passed through pipes or fixed to wall/poles etc cross sectional area of sizes 50 sqmm 3.5core including taking down of unserviceable cable complete all as specified and directed.
Supply, laying, jointing & testing, XLPE insulated, armoured, heavy duty electric LT UG cable with multi stranded aluminium conductor, 1100 volts grade laid in trenches or in duct/passed through pipes or fixed to wall/poles etc cross sectional area of sizes 10 sqmm 2core including taking down of unserviceable cable complete all as specified and directed.
Material & labour for straight through joint kit suitable for LT UG cable of size 16 to 35 sq mm all as specified and as directed.
Material & labour for straight through joint kit suitable for LT UG cable of size 50 to 95 sq mm all as specified and as directed.
Material & labour for straight through joint kit suitable for LT UG cable of size 120 to 185 sq mm all as specified and as directed.
Material & labour for straight through joint kit suitable for LT UG cable of size 240 to 300 sq mm all as specified and as directed.
Brick protection cover on cable with sub class 'B' brick, laid dry and flat adjacent to each other complete all as specified.
Material & labour for G.I. tubing light grade of size 100mm bore for protection of cables to be laid under roads, crossings/culverts complete all as specified and directed.
Material & labour for G.I. tubing light grade of size 50mm bore for protection of cables to be laid under roads, crossings/culverts complete all as specified and directed.
Supply and fix terminal boxes factory made out of 1.6mm thick PVC with hinges and locking arrangement of size 400x300x190mm housing in and including 25x4mm bus bar of suitable length - 04 Nos fixed on insulator with proper size of screw, in/out cable gland of suitable size of cables complete fixed on LT pole with nut, bolt and washers etc, complete all as specified and directed. Make:Sintex.
Material and labour for Busbar box outdoor type of size not less than 90 x 60 x 30 cm totally enclosed dust and vermin proof floor mounting with hinged doors and locking arrangement fabricated with 3.15 mm thick including cable glands, cable connection with lugs, grouting the cable angle-04 Nos in below ground level PCC 1:3:6 of size 300 x 300 x 300 mm,over the PCC 1:4:8 of size not less than 400 x 400 x 150 mm,bolts,nuts,washers etc., all as specified and directed by Engr-in-Charge. Note: Busbar bar box comprises the following items: (a) Incomer - MCCB 4 pole,415 Volts,200 Amps,Fixed thermal and magnetic type with breaking capacity of 25 KA - 01 No (b) High grade aluminium busbar of capacity 300 Amps-04 Nos (c) LED lamps for RYB indication - 01 set.
Supply and fix in repairs CTs suitable for air circuit breakers of rating 630 Amps to 800 Amps as all per existing.
Supply and fix in repairs Lockable Trip Push Button (LTPB) suitable for air circuit breakers of rating rating 630 Amps to 800 Amps as all per existing.
Supply and fix in repairs Locking of ACB in Isolated position (LIP) suitable for air circuit breakers of rating 630 Amps to 800 Amps as all per existing.
Supply and fix in repairs Racking Interlock suitable for air circuit breakers of rating 630 Amps to 800 Amps as all per existing.
Supply and fix in repairs Door Interlock suitable for air circuit breakers of rating 630 Amps to 800 Amps as all per existing.
Supply and fix in repairs Vertical Terminal Adaptors suitable for air circuit breakers of rating 630 to 800 Amps rated all as per existing
Supply and fix in repairs Under Voltage Release suitable for air circuit breakers of rating 630 Amps to 800 Amps as all per existing.
Supply and fix in repairs Earth Fault Release suitable for air circuit breakers of rating 630 Amps to 800 Amps as all per existing.
Supply and fix in repairs Microprocessor based release suitable for air circuit breakers of rating 630 Amps to 800 Amps as all per existing.
Supply and replace in repair - MCCB 4 pole, 415 volts, adjustable type, 100 Amps, 25 KA including disconnecting and removing existing with necessary connected fasteners, burnt cables, accessories etc,. all as per site requirement/existing make/model, all as specified and as directed.
All as item No .41 here-in-before but capacity MCCB 4pole, 415 Volts, Adjustable type , 160 Amps, Breaking capacity 36 KA
All as item No .41 here-in-before but capacity MCCB 4pole, 415 Volts, Adjustable type , 200 Amps, Breaking capacity 36 KA
All as item No .41 here-in-before but capacity MCCB 4pole, 415 Volts, Adjustable type , 250 Amps, Breaking capacity 36 KA
All as item No 41 here-in-before but capacity MCCB 4pole, 415 Volts, Adjustable type , 350 Amps, Breaking capacity 36 KA
All as item No 41 here-in-before but capacity MCCB 4pole, 415 Volts, Adjustable type , 400 Amps, Breaking capacity 36 KA
Supply and replace in repair - MCCB 3 pole, 415 volts, adjustable type, 100 Amps, 25 KA including disconnecting and removing existing with necessary connected fasteners, burnt cables, accessories etc,. all as per site requirement/existing make/model, all as specified and as directed.
All as item No .47 here-in-before but capacity MCCB 3pole, 415 Volts, Adjustable type , 160 Amps, Breaking capacity 36 KA
All as item No .47 here-in-before but capacity MCCB 3pole, 415 Volts, Adjustable type , 200 Amps, Breaking capacity 36 KA
Taking down old MCB TPN and Supply and fixing MCB TPN 63 Amps rating, 'C' series , 10 KA breaking capacity, 415 V, 50 Hz AC supply including making all connections complete all as specified . Note :- Make : Indo Asian or its equivalent in Havells / Standard / Legrand / Crompton Greaves.
Taking down old MCB TP and Supply and fixing MCB TP 63 Amps rating, 'C' series , 10 KA breaking capacity, 415 V, 50 Hz AC supply including making all connections complete all as specified . Note :- Make : Indo Asian or its equivalent in Havells / Standard / Legrand / Crompton Greaves.
Supply and fixing of on load change over switch 415 volts in sheet metal enclosure four pole of capacity 63 Amps including taking down of unservercible change over switch all as specified and directed.
All as item No.52 here-in-before but capacity four pole,415 volts,125 Amps.
All as item No.52 here-in-before but capacity four pole,415 volts,160 Amps.
All as item No.52 here-in-before but capacity four pole,415 volts,200 Amps.
Supply and replace in repair Sheet metal enclosure MCCB distribution board TPN 415 Volts 6 ways Double door with IP:54 protection, suitable bus bar for provn of MCCBs/ Isolators, fixed to wall and making all connections all as directed.
Supply and replace in repair Sheet metal enclosure MCB distribution board TPN 415 Volts 8 ways Double door with suitable bus bar for provn of MCBs/ Isolators, fixed to wall and making all connections all as directed.
Repair and maintenance of servo voltage stabilizer oil cooled/air cooled 300 KVA any make with complete calibration of systems, including all parameter as per manufacturer design servicing rectification of defects by replacing minor parts etc., and the major parts shall be measured as supply only under item No 59 to 62 relevant schedule while servicing once in three months all as directed by Engr-in-Charge. Note : (i) The quarterly service report shall be submit to Engr-in-Charge duly signed.
Supply only for item No 58 Carbon Brush up to 200k
Supply only for item No 58 Servo motor
Supply only for item No 58 Contactor/Relay
Supply only for item No 58 PCB suitable for 300 KVA AVR
Filtration of Servo voltage stabilizer oil from bottom to achieve di-electric strength not less than 40 KV for one minute as per relevant IS with portable filteration plant for checking di electric strength & acidity test of oil and carrying out dehydration (Filtration) of cooling/ insulating oil of LT switch gears through straight line oil filtration plant for removing carbon deposit, extracting moisture content etc.Di electric strength & acidity to be tested before and after filtration and submit the test results all as specified and directed by Engr-in-Charge. Note :- a) The rate quoted shall be deemed to include for taking necessary connections to filteration plant from stabiliser and switch gear oil duly removing the inlet and out let connections. (b) Electric supply for the filteration plant will be made available free of cost.
Supply only insulating /cooling oil suitable for LT switch gears having di electric strength of more than 40 KV for filling / topping up.
Earthing complete with galvanised iron earth plate electrode of size 600mm x 600mm x 6 mm thick buried directly under ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 metre below ground level connected to and including galvanised iron earth lead 4mm by means of bolts, nuts, check nuts, washer including test point by means of bolts, nuts, check nuts, and washers of galvanized iron and connected to main switch / control board up to 7.5 metre away from earth electrode and including GI pipe light grade 20 mm bore protection pipe & necessary excavation and earth work in any strata, PCC chambers in PCC 1:3:6 type B1, RCC 1:2:4 type B1 cover slab 50mm thick with 8mm dia TMT bars at 140mm C/C both ways, with lifting handle, watering pipe of GI medium grade 20mm dia, wire mesh, funnel, lugs and charcoal, salt etc all as applicable and as per plate No 3 of SSR Part-I and all as specified.
Earthing complete with galvanised iron earth plate electrode of size 600mm x 600mm x 6 mm thick buried directly under ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 metre below ground level connected to and including galvanised iron earth strip 32 x 6mm by means of bolts, nuts, check nuts, washer including test point by means of bolts, nuts, check nuts, and washers of galvanized iron and connected to main switch / control board up to 7.5 metre away from earth electrode and including GI pipe light grade 40 mm bore protection pipe & necessary excavation and earth work in any strata, PCC chambers in PCC 1:3:6 type B1, RCC 1:2:4 type B1 cover slab 50mm thick with 8mm dia TMT bars at 140mm C/C both ways, with lifting handle, watering pipe of GI medium grade 20mm dia, wire mesh, funnel, lugs and charcoal, salt etc all as applicable and as per plate No 3 of SSR Part-I and all as specified.
Material & Labour for Aluminium earth strip of size 25 x 3 mm in ground not exceeding 40 cm deep/fixing to wall/structure including taking down old strip complete all as specified and as directed.
Material & Labour for GI earth strip of size 25 x 4 mm in ground not exceeding 40 cm deep/fixing to wall/structure including taking down old strip complete all as specified and as directed.
Material & Labour for copper earth strip of size 32 x 6 mm in ground not exceeding 40 cm deep/fixing to wall/structure including taking down old strip complete all as specified and as directed.
Supply and laying Chequerred Rubber Mat 2mtrx1mtr length 10mm thick complete all as specified and directed. Make:Jyothi ISI mark or its equivalent
Supply/replacement of steel chequered plate of thickness 6mm for cable duct cover in power house duly painted on all sides with two coats of black synthetic enamel paint over a coat red oxide primer all as specified & as directed.
Supply only MCB Single pole, 240 volts 6 to 32 Amps 10 KA rupturing capacity, C series complete all as specified and directed.
Supply only MCB Single pole & neutral 240 volts 32 to 40 Amps, 10KA rupturing capacity, C series complete all as specified and directed.
Supply and fix in repairs Sheet metal enclosure with distribution board SPN 230V Volts 8 ways Double door with suitable bus bar for provn for MCBs/ Isolators, fixed to wall and making all connections all as directed. Make Havells / standard / Indo Asian
Material & labour for sub main wiring with Two runs of single core pvc insulated cable FRLS with copper conductor multistranded 1100 volts grade 4.0 sqmm through and including with suitable size of PVC conduit and its accessories , surface/ ceiling along with fixing arrangement etc including one run of 4.0 sqmm pvc insulated multistranded copper earth continuity conductor and connected to common earth dolly and taking down complete all as specified.
All as per item No 75 here-in-before but 2x 6sqmm with 1x6 sqmm as earth continuity conductor.
Supply and fix 1100 Volts grade heavy duty flat weather proof twin core cable of size 6 Sqmm with multistrand aluminium conductor for over head service connection suspended by insulating hangers not more than one meter apart including 4 mm dia GI suspension wire complete all as specified .
Servicing to LT panels/Feeder pillar boxes comprising MCCBs/switch disconnector fuses/change over switches/metering equipment etc.as incoming/outgoing controls including cleaning, checking the serviceability of individual items, identification of the defective parts and replacing the worn out fasteners,insulators,rubber door beadings,gaskets etc.complete all as specified and directed.Note:Unserviceable major parts replaced shall be measured & paid under relevant item.
Material and labour for plain cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate for path ways, hard standing & pole coping including necessary form work and applying two coats of white wash on exposed surfaces etc complete all as specified and as directed.
M/S SRI BALAJI ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .