Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance FATEHPUR | Admitted-Finance |
| 3 | Rejected-Technical | Rejected-Technical Rejected due to Technical Not qualified |
| 4 | Rejected-Technical VILLAGE NEVADA POST SAKALPUR DISTRICT VARANASI 221403 | VARANASI | VARANASI | UTTAR PRADESH | 221403 | Rejected-Technical Rejected due to Technical Not qualified |
| 5 | Rejected-Technical HOUSE NO 5 1 JALALIPATTI VARANASI BHULLANPUR VARANASI VARANASI UTTAR PRADESH 221108 | VARANASI | UTTAR PRADESH | 221108 | Rejected-Technical Rejected due to Technical Not qualified |
Tender Value
Refer Docs
EMD Value
₹26,000
Closing Date
13 Nov 2024, 1:00 pmClosed
SE,EDC,VARANASI
Superintending Engineer ELECTRICITY DISTRIBUTION CIRCLE, Purvanchal Vidyut Vitran Nigam Limited, Bhikharipur,Post- B.L.W Varanasi-221004
Work of protection of RMU, TPMO etc. on the industrial feeders of Rajatalab sub-station under the Add.Business Plan 2024-25.
2024_PVVNV_970372_1
36/EDC(V)/2024-25
Open Tender
Electrical Works
Lump-sum
365 days
VARANASI
Please refer Tender documents.
3 documents required · 3 mandatory
₹3,540
EE, EDD-II, VARANASI
₹26,000
Yes
21 Nov 2024
30 Oct 2024
13 Nov 2024
30 Oct 2024
13 Nov 2024
30 Oct 2024
11 ehVj yEcs ,l-Vh-ih- iksy dks [k.M ls lacf/kr foHkxh; LVksj lsUVj ls MEi LFky rd <qykbZ dk dk;Z ftles LVksj lsUVj ij ynkbZ] lkbZV rd <qykbZ ,oa mDr lkbZV ij mrjkbZ dk dk;Z “kkfey gSA ¼nwjh 0 ls 40 fd0eh0½
8-5 ehVj ih0lh0lh0 iksy dks [k.M ls lacf/kr foHkxh; LVksj lsUVj ls MEi LFky rd <qykbZ dk dk;Z ftles LVksj lsUVj ij ynkbZ] lkbZV rd <qykbZ ,oa mDr lkbZV ij mrjkbZ dk dk;Z “kkfey gSA ¼nwjh 0 ls 40 fd0eh0½
ykbZu ds fuekZ.k ls lacaf/kr leLr lkexzh ¼ih-lh-lh- ,oa ,l0Vh0ih iksy½ ,oa ifjorZd dks NksMdj½ foHkkxh; LVksj lsUVj ls MEi LFky <qykbZ dk dk;Z ftles LVksj lsUVj ij ynkbZ] lkbZV rd <qykbZ ,oa mDr lkbZV ij mrjkbZ dk dk;Z “kkfey gSA ¼nwjh 0 ls 40 fd0eh0½
jsLiks ekud ds vuqlkj 3x118 SQ mm dk dsfcy foHkkxh; LVksj lsUVj ls MEi LFky <qykbZ dk dk;Z ftles LVksj lsUVj ij ynkbZ] lkbZV rd <qykbZ ,oa mDr lkbZV ij mrjkbZ dk dk;Z “kkfey gSA¼nwjh 0 ls 40 fd0eh0½
jsLiks ekud ds vuqlkj 3x185 SQ mm dk dsfcy ckDl foHkkxh; LVksj lsUVj ls MEi LFky <qykbZ dk dk;Z ftles LVksj lsUVj ij ynkbZ] lkbZV rd <qykbZ ,oa mDr lkbZV ij mrjkbZ dk dk;Z “kkfey gSA¼nwjh 0 ls 40 fd0eh0½
jsLiks ekud ds vuqlkj TPMO lacaf/kr foHkxkh; LVksj lsUVj ls MEi LFky rd <qykbZ dk dk;Z ftles LVksj lsUVj ij ynkbZ] lkbZV rd <qykbZ ,oa mDr lkbZV ij mrjkbZ dk dk;Z “kkfey gSA ¼nwjh 0 ls 40 fd0eh0½
jsLiks ekud ds vuqlkj Sectonalisor Complete Set lacaf/kr foHkxkh; LVksj lsUVj ls MEi LFky rd <qykbZ dk dk;Z ftles LVksj lsUVj ij ynkbZ] lkbZV rd <qykbZ ,oa mDr lkbZV ij mrjkbZ dk dk;Z “kkfey gSA ¼nwjh 0 ls 40 fd0eh0½
jsLiks ekud ds vuqlkj 11 ehVj yEcs ,l0Vh0 iksy dks x<<k [kksndj rFkk lHkh fQfVax ckW/kdj ykbu feekZ.k djus dk dk;ZA
jsLiks ekud ds vuqlkj 8-5 ehVj yEcs ih0lh0lh iksy dks x<<k [kksndj rFkk lHkh fQfVax ckW/kdj ykbu feekZ.k djus dk dk;ZA
jsLiks ekud ds vuqlkj iwoZ esa yxs flaxy iksy esa 1 ux iksy yxkdj Mcy iksy fuekZ.k djus dk dk;ZA
jsLiks ekud ds vuqlkj Qksj iksy fuekZ.k djus dk dk;ZA
jsLiks ekud ds vuqlkj uofufeZr Mcy iksy ij Sectonalisor Complete Set yxkdj ekud ds vuqlkj LFkkiuk dj ÅthZd`r djus dk dk;Z A
jsLiks ekud ds vuqlkj uofufeZr Mcy iksy ij TPMO yxkdj ekud ds vuqlkj LFkkiuk dj ÅthZd`r djus dk dk;ZA
jsLiks ekud ds vuqlkj uofufeZr Qksj iksy ij RMU yxkdj ekud ds vuqlkj LFkkiuk dj ÅthZd`r djus dk dk;ZA
jsLiks ekud ds vuqlkj 3 Qst 11 ds0oh0 ykbZu ds dUMDVj dks p<kdj VkbV djus dk dk;Z ckbZfMax ds lkFkA
jsLiks ekud ds vuqlkj 3x185 SQ mm 11 KV Cable dks HDPE Pipe ds Through Laying djus dk dk;ZA (Including Cost of Bricks and sand Restoration Charges for Footpath Side )
jsLiks ekud ds vuqlkj 3x185 SQ mm Laying of 11 KV Cable Road Restoration for Footpath side
jsLiks ekud ds vuqlkj 3x185 SQ mm dk dsfcy Jointing djkus ,o dk dk;ZA
jsLiks ekud ds vuqlkj dsfcy dks th-vkbZ ikbZi ds vUnj Mky dj iksy ij p<kdj VkbV djus dk dk;Z ckbZfMax ds lkFkA ¼Hoisting of Cable for Pole With G.I Pipe)
iksy dh xzkmfVax ¼1%4%8 ds vuqikr esa lhesUV ckyw o fxV~Vh feykdj iksy dh xzkmfVax djus dk dk;ZA
leLr iksyksa dh vfFkZx djus dk dk;ZA
LVs fuekZ.k djus dk dk;ZA
iqjkus ttZj ykbu lkexzh dks iksy ls fQfVax o rkj dks fMlesUVy djus dk dk;Z o dk;Z LFky ls foHkxh; LVksj lsUVj rd igqpkus dk dk;ZA
Pipe Holding Clamp
Cable Holding Clamp
G.I Pipe 6” dia
Stone Pad 300x300x75 mm
Holding Clamp for Top Channel Fuse set etc With Bolts & Nuts
Nuts bolt All Size
11 KV Ring Main Unit SF-6Type (2IS0+3Breaker
A.l Crimping Lugs 185 Sq mm
Special Pipe Earthing
Clamp for T-off With Bolts & Nuts
X-Arm Holding Clamp With Bolts & Nuts
F-Bracket for Fitting Top Insulator With Bolts & Nuts
Aluminum binding Wire
Danger Board With Clamps &
Barbed Wire
G.I Pipe 150 mm “ dia (3 mtr Length)
Plinth for RMU Unit
Complete Fancing for Ring Main Unit
Complete Earthing for RMU through GI Strips (25x3)
HDPE Pipe 160 mm dia for Laying Unde Road
SWASTIK ENTERPRISES (BID ID -4717777)
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .