| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 LAccepted-Finance GRAM POST MAWANA KHURD MAWANA MEERUT | MEERUT | UTTAR PRADESH | 245206 | L1 | Accepted-Finance AS PER BOQ | |
| 2 | L2₹2.2 L+₹19,010 (9.52%)Accepted-Finance | L2 | Accepted-Finance AS PER BOQ | |
| 3 | L3₹2.2 L+₹24,030 (12.0%)Accepted-Finance | L3 | Accepted-Finance AS PER BOQ |
Tender Value
₹2 L
EMD Value
₹2,000
Closing Date
22 Jun 2023, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer
Electricity Distribution Circle II Saharanpur
Carrying out the various work in busniss plan scheme town of EDSD Kailashpur
2023_PVVNL_810685_1
41/W/EDC II/SRE/2023-24
Open Tender
Electrical Works
Lump-sum
365 days
SAHARANPUR
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
SE EDC II SRE
₹2,000
Yes
23 Jun 2023
9 Jun 2023
22 Jun 2023
9 Jun 2023
22 Jun 2023
9 Jun 2023
Amount
Detail of Work
Safely cartage of PCC/ST poles (8.5/9/13 Mtr. Long) from ESC, SRE/JE store to site of work including loading & unloading at both ends.
Safely cartage of other complete line material (Except PCC /ST Poles) from ESC, SRE JE store to site of work including loading, unloading at both ends.
Safe cartage of 25/63/100 KVA T/F from ESC,SRE, to the site of work including loading & unloading by private crain at both ends
Safe cartage of 250 KVA T/F from ESC,SRE, to the site of work including loading & unloading at both ends.
Erection of single support on PCC/ST poles (8.5/9/13 Mtr. Long) with complete fitting of all accessories of 11 KV/LT line.as per RESPO specification.
Erection of double on PCC/ST poles (8.5/9/13 Mtr. Long) with complete fitting with all accessories as per RESPO specification.
Fixing of 11 KV stay rods by digging of pits in block of 600X600X300 mm. & with new brick and nozzling of stay wire 7/10 SWG and fitting the same on the pole
Providing & fixing of LT clamp with nuts bolts made of new MS flat iron 50x6 mm on PCC poles as per RESPO specification.
Providing of LT shekel insulator of size 100x115mm
Providing & fixing of X-arm holding clamps PCC poles with nuts bolts made of new MS flat iron 50x6 mm as per RESPO specification.
Providing & fixing of F-brackets PCC poles with nuts bolts made of new MS flat iron 50x6 mm as per RESPO specification.
Providing & fixing of double Pole clamp on PCC poles with nuts bolts made of new MS flat iron 50x6 mm as per RESPO specification.
Opening of consumer cable connections for LT line then sagging, binding, jumpering and reconnection of cable of consumer.
Removal of old damaged weasel conductor from the Existing 11KV, LT lines with making roll of conductor and shifting the same to ESC, SRE/J.E (store) including loading and unloading at both ends.
Laying, lifting, Stringing, sagging jumpring & binding of ACSR Weasel Conductor for 11KV/LT Line as per RESPO specification including complete.
Laying, lifting, Stringing, sagging jumpring & binding of ACSR Dog Conductor for 11KV/LT Line as per RESPO specification including complete.
Earthing of poles by earthing rod as per RESPO specification.
Removal of 25/63/100 KVA T/F from the existing D/P after opening HT & LT connection and with shifting the T/F from the site to ESC, SRE/JE store with loading & unloading at both ends.
Earthing of 250 KVA T/F by boring 60 ft. deep and providing & fixing 60 ft. G.I. pipe 11/2 dia (Zindal class B) and connecting with G.I. strip of size 40x5 mm and G.I wire at bottom of G.I. pipe to the T/F with providing of requireed charcoal and salt in the pipe properly.
Safe installation of 25/63/100 KVA T/F on the double pole with complete fittings including making connections and commissioning.
Construction of plinth for installation of 250 KVA T/F of size 1.5x1.5x1.5 Mtr. made of 9" thick wall in all the four sides with 6" thick RCC top duly filled with sand & plastered 12 mm. thick in ratio 1:4 with cement & sand on outer surface of brick wall .
Safe installation of 250 KVA T/F on the Plinth with complete fittings including making connections and commissioning.
Laying and making connections of LT PVC/XLPE cable 3.5x70sq.mm./3.5x150/1x240 sq.mm. from T/F to double pole (approx to 20 Mtr).
Tightening of loose stay including opening, binding and nozzling of stay wire.
Straightening of tilted PCC pole/ST pole up to 13 Mtr.of 11 KV & LT lines with opening, binding and jumpering of conductor.
Re-strengthening of tilted D/P (PCC poles) with removing of T/F along with complete fitting and refitting of complete fitting after re-strengthening of tilted Double Pole.
Replacement of broken/damaged Disc insulators
Replacement of broken/damaged pin insulators
Re-sagging of loose conductor of 11 KV / LT line with opening binding & Re-binding with jumpring.
Off shooting of tree branches touching the 11 KV/LT line.
M/s Abinav Enterprises
M/s Manoj Enterprises
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .