Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.5 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹23.8 L+₹28,111 (1.20%)Rejected-AOC C 101 ADG P CHENNAI | L2 | Rejected-AOC Rejected | |
| 3 | L3₹23.9 L+₹33,801 (1.44%)Rejected-AOC C O BHAGYODAY STORES BAZAR CHOWK NALIYA KUTCH 370 655 | KACHCHH | GUJARAT | 370655 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹24.2 L+₹69,230 (2.94%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹27.0 L+₹3.5 L (14.7%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹46,000
Closing Date
18 Nov 2020, 6:00 pmClosed
BANGALORE
GARRISON ENGINEER NORTH BANGALORE T 64 MEANEE LINES MEG AND CENTRE BANGALORE 560042
PROVN OF AUTOMATIC METER READING SYSTEM WITH SMART ENERGY METER WITH CONNECTED WORKS AND PROVN OF SMART STREET LIGHTING SYSTEM WITH LED LIGHTS AT FMME UNDER GE NORTH BANGALORE
2019_MES_246551_3
8375
Open Tender
Electrical and Maintenance Works
Item Rate
885 days
BANGALORE
Class E category b(i) d (iv)
7 documents required · 7 mandatory
₹500
Yes
GARRISON ENGINEER NORTH BANGALORE
₹46,000
Yes
22 Dec 2020
9 Oct 2020
20 Nov 2020
9 Oct 2020
18 Nov 2020
2 Nov 2020
10 Oct 2020 - 16 Oct 2020
Amount
Supply, install, testing and commissioning of Microprocessor based Single phase tamper proof electronic static energy meter,surface mount type and of rating 415 Volts, 50 Hz of range 5-30 Amps, conforming to IS 13779 & IS15884 with LED display and parameters like Voltage, Current, Frequency, Power, Powerfactor,KWh/KVA, default /in built dual source, in built long range RF Communication suitable for outdoor Long Range data accumulator(LORAWAN) and also compatible for Prepaid come Postpaid online energy monitoring / billing system, with Auto SMS /e-mail alerts ,Mobile App to the user and disconnection / reconnection through remote software / data export to ERP complete all as specified and as directed by Engr-in-Charge. Make : Elmeasure, Cat No : PE5121 or techno-commercially equivalent in L&T /Secure meters.
Supply, install, commissioning and testing of outdoor long range accumulate DCU/RTU with 1.5KM data collection capacity and the data transfer to the Software complete all as specified and as directed by Engr-in-Charge. Make : EL Measure or techno-commercially equivalent in SILCORE / L&T/Secure meters. (a)The cost of pole including fixing and mounting arrangement on which the accumulator to be installed and SMPS power supply is deemed to be included in the unit quoted rates. (b)The complete work of installation, testing, commissioning and software linking should be as per the requirement of GE/Engr-in-Charge to be got executed by the OEM only. No channel partners/system integrator will be entertained (c) Any item missed in the specification but technically required for satisfactory working of the device is deemed to be included in the unit quoted rates.
Supply and Installation of Network Server, MQTT based intelligent network server for bridging between gateway and end application,eliminate duplicate packets, schedule acknowledgement and adapts data rates complete all as specified and as directed.
Annual comprehensive maintenance (for a period of two years) of energy meters and street light fittings including repair / replacement of energy meters, gateways, antennas, RTU, contactors with all connected accessories and components as well as solving any software related issues including GPRS charges of SIM cards for 67 Nos of energy meters and 32 Nos of street light network, network software, all hard ware etc., complete all as specified and as directed.The AMC Will start from 2 Years Default Products warranty period . NOTE:- All The supplied Products must be with 2 Years Warranty Period. During Warranty Period bidder is reponsible for the following i)Meter data collection. ii)) Both Hardware and software installation including commissioning and maintenance complete all as specified and as directed.
Supplying, fixing, commissioning and testing of configuration of server hosted multi user web based software with following modules: (i) Meter Data Management Module: The meter data management module would be responsible for collecting the data from the data concentrator and make the data available to the billing system. The system would support offline meter data entry. The meter data management system would capture and provide the follwing data: (a) 15min instantaneous data from all the meters for seven parameters- Cumulative Energy,Power, Current, Voltage, Power factor and Frequency. (b) Monthly and quarterly billing survey data for cumulative energy and max demand (ii) Billing Module: The billing module would collectg the data from the meter data management module, calculate billing determinant and make energy data/ billing data available to admin and end users. (iii) Occupation and vacation Module: The System would support occupation/ vacation based on the unit categories. The system would support automatic data capture on occupation and vacation events. (iv) Customer portal: The system would include a customer portal for the resident/ occupant to log in and view their own energy / billing data. (v) Energy Accounting Module: The system would include features of energy accounting. the system would be able to account for total energy bloack wise, facility wise and would also allow calcyulations of unaccounted energy in case total energy meter is also available. (vi) Communication module: The system would provide communication of energy data and bills via print, email and sms methods. contd... 1.06
1.05 Contd.. (vii) Meter Master Data : The system would support meter data repository. The system would support meter replacement process. (viii) Excel Export : The system would support export of metering and billing data in excel format Make : Elmeasure / L&T / Secure/ Silcore (ix) The controlling for smart street light system shall be connected to the Lo Ra Wan network and the parameters of the same shall be accessible to the Pc/Mobile of JE/AGE at their office. The cost of the same shall be included in the quoted rate. NOTE:- (i) The contractor shall provide proper training from the OEM to the MES employees for operation / regular maintenance required for the smooth operation of smart metering and street light system after completion of the work with out any extra cost ot Govt. (ii) During the defect liability period and currancy of the contract, the contractor shall attend and rectify the complaints of smart metering system / smart street light system within 24 hours after the complaint reported and completion report shall be submitted to the AGE (E/M) failing which penal recovery of Rs. 1000/ per complaint per day will be levied on the frim for delay in rectification of defects.
Supply, install, testing and commissioning of personal computer desk top all in one type with 8 GB RAM, ITB HDD , 9 th generation intel core i5 processor, 21.5 full HD LED display etc., with inbuilt original version of Windows 10 OS and inbuilt original version of MS office, antivirus etc all as specified and directed. MAKE:- HP Model No: 22-c063il or techno commercial equivalent make in DEL / LENOVO.
Supply, insallation, testing and commissioning of Laser shot printer with black & white printing catridge with USB connectivity , 220-240 V , 50 Hz and High speed interface etc., complete all as specified and as directed. MAKE:- HP:-1020 Plus or equivalent
UPS 600 VA suitable for PC use all as specified and as directed. MAKE:- Luminous Model No: Pro 600 or equivalent .
Dismantling MS electric meter box of any type, any size including dismantling switch gear etc., complete, fabricate, supply and fix electric meter box, made out of 2 mm thick MS Sheet, double door and locking arrangements (concealed in wall) as per existing size /dimensions of not less than 1000 x750x300 mm with suitable thickness of hylem sheet suitable for fixing electric meter -08 Nos, MCCBs, DBs etc., and including provision of look out glass-02 Nos, connecting wire with copper cable of required size, applied with powder coated paint of approved colour with locking arrangements with keys and making good to the disturbed wall surfaces complete all a sspecfied and as directed. NOTE:- 1. The old un serviceable energy meter shall be deposited to MES store . 2.The rate quoted by the contractor shall be deemed to be included the cutting of existing wall , finishing of wall to match with the exisiting surface by applying required cement plaster and painting etc., complete all as specified and as directed.
Vertical DB VTPN, MCCB DB, TPN, 8 ways, IP-43 protection, door earthing, isolated neutral busbar, isolated busbar assembly including MCCB 125 Amps,25 KA TP as incomer concealed in walls all as per Indo Asian Cat No. 811890 or techno commercial equivalent makes specified in PS complete all as specified and as directed.
MCB SP 6-40 Amps 'C' curve complete all as specified and as directed.
Sub main wiring with two runs of single core 6 sq.mm, 1100 volts grade multi stranded copper conductor cable along with one run of 6 sq.mm PVC insulated single core multistranded copper conductor cable as earth continuity conductor drawn through and including non rigid PVC conduit medium grade of suitable size including taking down the existing complete all as specified and as directed. NOTE: 1.Two runs of 6 sq.mm cable, one run of 6 sq.mm earth continuity conductor and one run of PVC conduit shall be measured as one unit for payment purpose. 2.The rate quoted shall be included the cutting of exisitng wall and finishing the surface to match with the exisiting wall including plastering and painting any, if required.
XLPE insulated, galvanised steel strip or wire armoured and PVC bedded, heavy duty, LT cable 16 sq.mm, 4 core, 1100 volts grade with multi stranded aluminium conductor, including cable glands, cable lugs etc., to suit the cable size, laid in trenches, or fixed along with the poles, bare or through GI pipe, laid under floors / road etc., fixed / concealed in walls / encased in GI pipe etc., jointing and testing including the fixing arrangement like clamps ,saddlles etc all as specified and directed.
XLPE insulated, galvanised steel strip or wire armoured and PVC bedded, heavy duty, LT cable 25 sq.mm, 3.5 core, 1100 volts grade with multi stranded aluminium conductor, including cable glands, cable lugs etc., to suit the cable size, laid in trenches, or fixed along with the poles, bare or through GI pipe, laid under floors / road etc., fixed / concealed in walls / encased in GI pipe etc., jointing and testing including the fixing arrangement like clamps ,saddlles etc all as specified and directed.
XLPE insulated, galvanised steel strip or wire armoured and PVC bedded, heavy duty, LT cable 6 sq.mm, 4 core, 1100 volts grade with multi stranded aluminium conductor, including cable glands, cable lugs etc., to suit the cable size, laid in trenches, or fixed along with the poles, bare or through GI pipe, laid under floors / road etc., fixed / concealed in walls / encased in GI pipe etc., jointing and testing including the fixing arrangement like clamps ,saddlles etc all as specified and directed.
Galvanised iron tubing, light grade, 40mm bore with all accessories for cable protection fixed on poles/buildings or laid in trenches including necessary MS clamps, bolts and nuts etc., complete all as specified and as directed.
Galvanised iron tubing, light grade, 50mm bore with all accessories for cable protection fixed on poles/buildings or laid in trenches including necessary MS clamps, bolts and nuts etc., complete all as specified and as directed.
RTC based energy efficient 90 Watt INVERTER LED Street Light fittings of housing material: Aluminum PDC, top maintainable front cover: clear toughened glass lens: suitable high efficient secondary lens LED: LM80 certified LED, lumen maintenance: 50,000 hours @ L70 Control Gear: Isolated, Electronic, CC driver RTC enabled Auto ON/OFF Inverter Mode: upto 30% ±10% of Rated power Battery Back-up Li-ion (10400 mAH) Control Gear Back Cover: Polycarbonate Cover Internal Wiring: Insulated Cu wire Hardware: SS & MS Zinc plated and passivated Ingress Protection: IP66 Impact Resistance: IK05 Operating , single phase Voltage: 140V~270V Operating Temperature: -10ᵒC~ 50ᵒC Dimming: Factory set auto 2 step pre programmable dimming , Luminous efficacy 120 lm /watt, CCT:-6000K. CRI ≥ 70, THD ≤10 %,driver sufficiency ≥85 % confirming to IS – 10322 (aprt 5) all as specified and directed. Make & Model No: HLSLD-ML21-90-CWL-INV-RTC-DIMM of Halonix or techno commercial equivalent makes in Havells/ Bajaj.
Steel tubular swaged poles complete with cast iron base plate, finial tapper plug, bolts, nuts & screws as specifiedfor type 410 SP-31, 9 Mtr long complete all as specified and as directed. NOTE:- Earth work and PCC will be measured and paid separately under relevant item of schedule 'A'.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in deep for cable and getting in hard/dense soil complete all as specified and as directed by Engineer-in-charge
Returning, filling in excavated soil, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in hard / dense soil etc complete as specified as directed.
Removing the excavated material to a distance exc. 50m but n. exc. 100m and depositing where directed at a level n. exc. 1.5m above the starting point complete all as specified and as directed.
Sand cushioning in layers for cables in trenches / ducts for cable including consolidation complete all as specified and directed. NOTE:- Punned thickness will be measured for payment purpose.
Bricks, sub class 'B' of old size 230 mm x 115 mm x 75 mm laid in trenches for cable protection all as specified and directed.
Horizontal trenchless bore drilling using mechanical pneuumatic drilling equipment for passing and including cost of HDPE pipe of 80 mm dia suitable for 0.4 Mpa working pressure as in hard standing, depth range not less than 0.75m and up to 1.0 m and making good to disturbed surface of road all as specified and as directed: NOTE:- Quoted rate is deemed to be incllude the cost of deposit and taking permission from civil authorities.
Wiring with two runs of single core 1.5 sq.mm PVC insulated FR Cable with multistranded copper conductor, 1100 volts grade, drawn through HDPE/GI pipes / on steel tubular poles including provision of one run 1.5 sq.mm PVC insulated FR Cable with multistranded copper conductor as in earth continuity conductor connected to main earth dolly all as specified and as directed. NOTE: Two runs of 1.5 sq.mm cable, one run of 1.5 sq.mm earth continuity conductor shall be measured as one unit for payment purpose.
PVC cable loop box of size 200 x 140 x 95 mm outside dimension out door type duly fitted on bottom of Steel poles with suitable clamps, nut, bolt and washers complete with porcelain insulated connectors for in and out going connections complete all as per Sintex model No: GSJB 2014 or techno commercially equivalant makes specified in PS all as specified and directed.
Plain Cement Concrete, (1:4:8), type D2 using 40 mm graded stone aggregate for filling and mass concrete of pole / cutting of road, all as specified and as directed.
Plain Cement Concrete, (1:3:6) type C-1 using 20mm graded stone aggregate as in copings of pole including necessary form work, weathering slightly rounded or chamfered angles and throating etc complete all as specified.
Brackets made out of GI tubing medium grade 40mm bore of 0.90 mtr length bent to required shape and pattern to mount the street light, including MS clamps made out of MS flat iron 25 x 10mm, nuts, bolts, washers etc and applying two coats of alumium paint over a coat of red oxide primer to fixing accessories complete all as specified and as directed.
Earthing complete with galavnized steel earth plate electrode 600mm x 600mm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 meter below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to and including galavanised iron wire of 4 mm dia as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles, check nuts and washer etc made of galavnised iron connected to earthing test point through protection pipe light grade of 20 mm dia all as shown in electrical plate No 3 of SSR Part - I 2009 and as specified or indicated and testing on completion including earth work and excavation in any type of soil PCC (1:3:6) type C 1 chamber, pre cast slab 40mm thick in cement concrete (1:2:4) type B-1, with 10 mm dia TMT steel bars reinforced at 100 mm centre to centre both ways including funnel with watering pipe of 20 mm dia medium grade ,wire mesh and lugs, test point including cable connected with suitable size with copper lugs complete all as specified and as directed.
All as per Sl Item No. 1.32 here in befroe but in repairs including removal of existing earthing.
Taking down ACSR conductor of any size any type all as specified and as directed.
Taking down energy meter fixed in panels of any capacity / any type after carefully disconnecting electrical connections all as specified and as directed by Engr-in-Charge. Note:- Quoted rate shall deemed to be inclusive of following parameters:- (a) Meter reading record shall be submitted before and after replacement duly signed by the contractor rep and MES rep. (b) Old meters should be handed over to MES store. (c) Any rejoining of wires /cables shall be done using suitable ferrule /cable connectors after removal of meter. (d) The cost of making good disturbed surfaces & matching to the existing surface is deemed to be included in the unit quoted rates. (e) The sintex box removed shall be reused for fixing of new meter and the cost for the same shall be included in the quoted rate.
Supply, install, testing & commissioning of Microprocessor based three phase tamper proof electronic static energy meter, surface mount type and of rating 415 Volts, 50 HZ, of range 10-60 Amps, confirming to IS 13779 & IS15884 with LED display and parameters like Voltage, Current, Frequency, Power, Powerfactor,KWh/KVA, default /in built dual source, inbuilt long range RF Communication suitable for outdoor Long Range data accumulator(LORAWAN) and also compatible for Preaid come Postpaid online energy monitoring / billing system, with Auto SMS /Email Alerts ,Mobile App to the user and disconnection /reconnection through remote software / data export to ERP complete all as specified and as directed by Engr-in-Charge. Make : Elmeasure, Cat No : PE5120 or techno-commercially equivalent in L&T /Secure meters.
ACE PROMOTERS
Krishna Engineering
SAI HARSHMY ENTERPRISES
SREE VARU ELECTRICALS
UNIVERSAL ENGINEERING
RAHUL ENTERPRISES
H S S ENGINEERS AND CONTRACTORS
ANAND REFRIGERATION
S S BUILDERS
PATEL CONSTRUCTION
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .