Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.5 LAccepted-AOC H NO 597 SEONA ROAD RANJIT NAGAR PATIALA PB 147001 | PATIALA | PATIALA | PUNJAB | 147001 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹49.4 L+₹1.0 L (2.17%)Rejected-Finance 300 PREM BASTI 10 SANGRUR SANGRUR PUNJAB 148001 | SANGRUR | PUNJAB | 148001 | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | L3₹51.7 L+₹3.3 L (6.76%)Rejected-Finance 852 EKTA VIHAR 1 C NEAR ANAND NAGAR 9 B PATIALA 147001 | PATIALA | PATIALA | PUNJAB | 147001 | L3 | Rejected-Finance NOT BEING LOWEST | |
| 4 | L4₹54.9 L+₹6.5 L (13.5%)Rejected-Finance 32 FATEH ENCLAVE OFFICERS ENCLAVE PHASE II PATIALA 147001 PB | PATIALA | PATIALA | PUNJAB | 147001 | L4 | Rejected-Finance NOT BEING LOWEST |
Tender Value
Refer Docs
EMD Value
₹88,260
Closing Date
1 Jan 2025, 6:00 pmClosed
LT COL SANDEEP KUMAR
GE NORTH PATIALA MILITARY ENGINEER SERVICES SANGRUR ROAD PATIALA CANTT
SPECIAL REPAIR FOR REPLACEMENT OF BER SUMMER APPLIANCES AND BER VERTICAL TURBINE PUMP AND CERTAIN SANCTION WORKS UNDER GE (N) PATIALA
2024_MES_686450_1
GE (N)/TOKEN-63/2024-2025
Open Tender
Civil Works
Item Rate
180 days
PATIALA
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE NORTH PATIALA
₹88,260
Yes
19 Feb 2025
30 Nov 2024
3 Jan 2025
30 Nov 2024
1 Jan 2025
18 Dec 2024
Amount
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan getting out soft /loose soil complete all as specified and as directed
M & L for Reinforced concrete pipes of 300 mm bore, class NP3, laid and jointed complete with collars and jointed complete in cement mortar (1:1) complete all as specified and directed by Engr-in-charge.
M & L for Plain Cement Concrete Type D2 1:4:8 (using 40 mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and directed by Engr-in-charge.
M&L for bricks sub class B, in cement mortar 1:4 including flush pointing as the work proceeds .complete all as specified and directed.
M&L for cement plastering 15mm thick in cemet mortar 1:6 on brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge.
M & L for Plain Cement Concrete Type B2 1:2:4 (using 40 mm graded stone aggregate) in surface channels and drain, complete all as specified and directed by Engr-in-charge.
M & L for Plain Cement Concrete Type B0 1:2:4 (using 12.5 mm graded stone aggregate) in roof kerbs or mud stops, rounded or chamfered on edges , lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, water troughs and the like including weathering, slightly rounded or chamfered angles and in coping all as directed and specified.
M&L for bricks sub class B, in cement mortar 1:6 complete all as specified and directed by Engr-in-charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick for soft loose soil complete all as specified and directed by Engr-in-charge.
Removing excavated soils not exc 50 M and depositing where directed at a level not exc1.5 M above the starting point complete all as specified and directed by Engr-in-charge.
M&L for Concrete bed to drain pipes including packing under and completely surrounding pipes with concrete after they are laid and tested; in cement concrete 1:4:8 type D2 complete all as specified and as directed
Supply and fix Deep Freezer Hard top upto 320 L Capacity having single door ,Aesthetic Soft Look Design,Stucco Aluminium inner liner, UV grade plastic material, Spring loaded hinges for effortless usage,Corrosion Resistant and Stabilizer Free Operation Low Maintenance. Optimum Cooling complete all as specified and directed.
Supply and fix water cooler electric driven (single phase), having approx storage capacity of 80 litre and nominal cooling capacity of 40 Litres per hour complete body including tanks inside are made of food grade stainless steel, Eco-friendly, Faster cooling, Sturdy compressor and trouble-free operation complete all as specified and directed.
Supply and fix air cooled split unit air conditioner electric driven, hot and cold type all weather single phase of capacity of 2 TR, BEE 3 star rated complete all as specified and directed.
Supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 170 V with output voltage stabilized at 230 V and of capacity 5 kva complete all as specified and directed.
Supply and fix room window type air conditioner electric driven (single phase), cooling capacity 4500 K Cal per hour ( 1.5 Ton).BEE 5 star rated complete all as specified and directed by Engr-in-charge.
Supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 170 V with output voltage stabilized at 230 V and of capacity 3 kva complete all as specified and directed.
Supply and fix Referigerator, electric driven( single phase), single door,capacity 195 L BEE 5 star rated, Stabilizer Free Operation, Anti-Fungal Gasket, Energy Efficient, Floor Standing complete all as specified and directed .
Supply and fix refrigerator, electric driven (single phase), capacity 308 Litre .BEE 3 star rated, Stabilizer Free Operation, Anti-Fungal Gasket, Energy Efficient, Floor Standing complete all as specified and directed .
Taking down existing BER VT pump set installed at VT pump room in BML including depositing the same in MES store yard including Supplying, lowering, installing, testing and commissioning of VT pump set of flow 705 cum/hr, 1475 RPM,415V, bell mouth and casing neck ring made out of CI, CF 8M impeller, Pump/sleeve made out of SS 410 all as specified and as directed by Engr-in-charge and as per Manufacturers instructions. :- (i) The capacity of motor pump shall be suitable to give a required discharge at the required head. (ii) Old unservicable pump shall be deposited in the store yard. (iii) The required T&P items shall be arranged by the contractor and cost thereof shall be included in the unit rate quoted. (iv) Contractors are advised to visit the sites before quoting the rates.
Technical Details/Specification For pump 1. Pump Type Vertical Turbine 2. No of Stages - 1 3 Liquid Handled - raw water 4 Specific gravity - 1 5. Ambient Temperature- 45 Deg Cel 7. Minimum Submergence Required (MM) - 1485 8 Bottom Clearance Required (MM) - 622 9. Rated of flow (M3 /HR) - 705 10 Bowl Head (M) -15 11 Specific gravity of liquid - 1 12. RPM- 1475 13 Bowl Efficiency (%) - 83.06 14. Bowl Input @ Duty Point (KW) - 34.67 15. Internal Head Loss (M) -0.456 16 Transmission and Thurst Bearing Losses (KW) - 0.25 17. Pump Input (KW) - 35.38 18. Discharge Outlet Size (MM) - 300 19. Suction Size (MM) - 598 20. Bearing Span(M) 1.5 21. Rated Impeller Diameter in MM(Approx.) - 399 22. Type Of Stuffing box Sealing -Gland Packing 23. Thurst Bearing Lubrication -Grease 24.Line Shaft Bearing Lubrication -Self 25.. Direction of Rotation from TOP(DE) -CW 26.Type of Installation of delivery bend -Above floor
Prime Mover Details 1. Motor Make CGL 2. Motor Rating(KW/Pole) 45KW/4P/415V/IE2 3. Voltage 415+/-10% 4. RPM 1475 35 Enclosure IP 55 5. Type Flange Mounted vertical 6. Frequency 50Hz ± 3% 7. Insulation F- Class, Temp. rise limited to Class-B 8. Direction of rotation From NDE- CW Material of Construction 9. Casing/bell mouth - CI 10. Casing Neck Ring - CI 11. Impeller CF8M 44 Pump / Intermediate/Top Shaft -SS410 12. Sleeve -SS410 13. Pump / Intermediate Bearing Bush -CIP MARINE 14. Thrust Bearing STD 48 Rising Main Pipe- MS 15. Motor stool Cum Delivery Bend- MS 16. Straine - MS 17. Fasteners - STD 18. Sealing- Gland Packing 19. Lubrication for Thrust Bearing- Grease Testing 1. Performance Testing- ISO 9906 Gr 2 2. Hydro Test Pressure Testing- 1.5 Times of Shut Off or 2 times of Duty point head which every is higher for 10 Mins. 3.Dynamic Impeller Balacing - ISO 1940 Gr. 6.3.
M&L for oscillating and tilting wall mounted fan with easy neck tilting 230V, 400mm Sweep, speed 1350 rpm as directed and specified by EIC
Supply and fix Exhaust fan AC single phase 230/240 v of size 300 mm sweep 900 rpm metal body, high efficiency motor, dynamically balanced blade for better performance and corrosion-resistant powder coated metallic finish including Louver,electrically connecting with twisted three core PVC insulted unsheathed flexible cord of 0.75 Sqmm copper conductor from ceiling rose to metallic Exhaust fan complete all as specified and directed by Engineer-in-Charge.
Supply and fixing for sub main wiring two single core PVC insulated and unsheathed FRLSH cable with 1.5 Sqmm multi -strand copper conductor drawing in new PVC concealed conduit of suitable dia with 1.5 Sqmm PVC FRLSH copper conductor cable as in earth wire system complete all as specified and directed. Note1: Neccessary cutting chasing wherever required and making good the disturbed surface shall be part of job at no extra cost. Note 2: Two runs of 1.5 sqmm cable alongwith one run of 1.5 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one length
M&L modular switch 1 way 6 A, 1 module complete all as specified and directed.
M&L ceiling rose surface 65mm X 17 mm polycarboneted type three terminal complete all as directed by Engineer-in-charge.
M & L for making holes for exhaust fan of suitable size and finishing the surface with CM (1:4) and PCC including two coat of required finish to match the existing surface complete all as specified and as directed by Engr-in-Charge.
S & F Modular white cover plate with frame, 1 module complete all as specified and directed.
S & F Metal Flush Boxes 1 module complete all as specified and directed
Fixing only Deep freezer with hard top of 320 litre capacity having single door with all accessories required at site complete all as specified and directed by Engr-in-charge. Note : Deep Freezer, will be supplied by the Department free for Fixing only.
Fixing only air cooled split unit air conditioner electric driven single phase of capacity of 2 TR, BEE 3 star rated with all accessories required at site complete all as specified and directed by Engr-in-charge. Note :Split Air Conditioner will be supplied by the Department free for Fixing only.
Fixing only water cooler electric driven (single phase), having approx storage capacity of 80 litre and nominal cooling capacity of 40 Litres per hour with all accessories required at site complete all as specified and directed by Engr-in-charge. Note : Water Cooler will be supplied by the Department free for Fixing only.
Supply and Fix only of copper pipe heavy duty of size 5/8" with all accessories required at site complete all as specified and directed by Engr-in-charge.
Supply and Fix copper pipe heavy duty of size 3/8" with all accessories required at site complete all as specified and directed by Engr-in-charge.
Supply and Fix pipe insulation for copper pipe of size 5/8" and 3/8" with all accessories required at site complete all as specified and directed by Engr-in-charge.
Supply and Fix for sub main wiring with two single core 4.0 Sqmm PVC insulated and unsheathed FRLS ,multi-stranded copper conductor cable drawn through metallic concealed conduit 25 mm dia incl 2.5 Sqmm PVC insulated unsheathed FRLS multi-stranded copper conductor cable as earth wire with all accessories required at site complete all as specified and directed by Engr-in-charge.
Supply and Fix earth metal plug and socket with MCB SPN 32 amp complete all as specified and directed by EIC.
AGGARWAL & CO (BID ID -3197009)
Arneja Builders (BID ID -3196215)
SWAMI ENGINEERS (BID ID -3203935)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .